| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Varispenser 2 / Varispenser 2x |
| Instrument Type | Electronic Bottle Top Dispenser |
| Sterilization | Autoclavable (121 °C, 20 min, full unit) |
| Chemical Resistance | Full-body PTFE/ETFE/FEP/PFA/PP construction |
| Valve System | Precision piston-driven with integrated recirculation valve (Varispenser 2x only) |
| Dispensing Accuracy | ≤ ±0.5% CV (per ISO 8655-3) |
| Volume Range | Adjustable from 0.2 mL to 100 mL per dispense (model-dependent) |
| Operating Temperature | 10–40 °C |
| Humidity Limit | ≤ 80% RH (non-condensing) |
| Brand | Eppendorf |
|---|---|
| Country of Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Top Buret |
| Price Range | USD 650 – 1,300 |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Research plus |
| Instrument Type | Single-Channel Manual Pipette |
| Channels | 1 |
| Volume Range | 0.1 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±0.6% |
| Sterilization | Full-unit autoclavable at 121 °C, 20 min, 1 bar |
| Ergonomic Certification | Compliant with Eppendorf PhysioCare Concept |
| Piston System | Eppendorf PerfectPiston™ |
| Tip Attachment | Elastic Tip Cone (excludes 5 mL and 10 mL variants) |
| Volume Display | Four-digit magnified digital window |
| Adjustment Mechanism | Rotational volume setting with tactile feedback |
| Density Adjustment | Optional density correction function for non-aqueous or temperature-sensitive liquids |
| Maintenance | Quick-release lower sleeve for cleaning and service (excludes 5 mL and 10 mL variants) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multipette M4 |
| Instrument Type | Single-Channel Manual Dispenser |
| Automation Level | Manual |
| Channels | 1 |
| Volume Range | 1 µL – 10 mL |
| Maximum Reservoir Capacity | 50 mL |
| Accuracy | ±0.3% |
| Principle | External Piston (Positive Displacement) |
| Brand | New Brunswick |
|---|---|
| Origin | USA |
| Model | Innova 44/44 R |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | Continuous Control |
| Oscillation Speed | 25–400 rpm |
| Orbit Diameter | 2.5 cm (1") and 5.1 cm (2") |
| Temperature Range | Innova 44: +5 °C above ambient to 80 °C |
| Innova 44 R | –20 °C below ambient to 80 °C (minimum 4 °C) |
| Number of Platforms | 1 |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | epMotion 5075v / 5075vt |
| Plate Positions | 12 |
| Liquid Handling Range | 0.2 µL – 1,000 µL |
| Sample Throughput | 12 samples per run |
| Dimensions (W × D × H) | 108 × 62 × 87 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Technologies Corporation (Himac) |
| Type | Floor-standing refrigerated ultracentrifuge |
| Speed Range | 300–30,000 rpm |
| Max RCF | 110,000 × g |
| Max Capacity | 6 × 1,000 mL or 4 × 1,500 mL |
| Noise Level | < 56 dBA |
| Dimensions (W×D×H) | 708 × 892 × 866 mm |
| Weight | 310 kg |
| Temperature Control Accuracy | ±2 °C |
| Refrigerant | R410A |
| Power Supply | AC 220 V, 50/60 Hz, 1500 W max |
| Interface | 1× USB, 1× LAN |
| Program Storage | 1,000 protocols |
| Timer Range | 1 s–9 min 59 s (1-s increment) or 1 min–99 h 59 min (1-min increment), with hold function |
| Acceleration Profiles | 11 modes |
| Deceleration Profiles | 10 modes (incl. 2 variable slope) |
| Safety Features | Interlocked door, overspeed detection, imbalance sensing, rotor lid detection, overtemperature protection |
| Sterilization Compatibility | Autoclavable rotors (121 °C, 20 min) for R30AT, R10A3, R5S4 |
| Drive System | Inverter-controlled induction motor |
| Cooling System | Variable-speed rotary compressor |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | DASGIP |
| Price Range | USD 25,000 – 65,000 (FOB Hamburg) |
| Temperature Control Range | 2–12 °C (external jacket cooling only |
| full bioreactor operating range | 20–55 °C with integrated heating/cooling) |
| Working Volume Range | 0.2–3.8 L per vessel |
| Vessel Configuration | 1, 3, or 4 parallel vessels |
| Gas Flow Control | Individual thermal mass flow controllers (MFCs) per vessel |
| Aeration Options | Ring sparger or microbubble diffuser |
| Agitation | Top-driven magnetic or mechanical stirrer (vessel-dependent) |
| pH Range | 2.0–12.0 (with standard electrodes) |
| Dissolved Oxygen (DO) Range | 0–200% air saturation |
| Sterilization Method | Autoclavable (121 °C, 20 min, 1.1 bar gauge) for glass vessels |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Mastercycler X50 |
| Instrument Type | Gradient PCR Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 10 °C/s |
| Temperature Accuracy | ±0.15 °C |
| Inter-well Temperature Uniformity | <0.2 °C (at 20–72 °C), <0.3 °C (at 90 °C) |
| Network Capability | Up to 10 units daisy-chained locally |
| Thermal Lid | flexlid® automatic height-adjusting heated lid |
| Warranty | 2 years |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Imported Instrument |
| Model | epMotion 5075l |
| Plate Positions | 15 |
| Pipetting Accuracy | ±0.05 µL |
| Pipetting Range | 0.2 µL – 1 mL |
| Throughput Formats | 96-well and 384-well plates |
| Dimensions (W × D × H) | 108 × 62 × 87 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Eppendorf Mastercycler® X40 Gradient PCR Cycler |
| Sample Capacity | 0.1 mL tubes, 0.2 mL tubes, 8-strip tubes, 96-well plates |
| Heating Rate | 3.3 °C/s |
| Temperature Accuracy | ±0.15 °C |
| Well-to-Well Uniformity | ±0.2 °C across 20–72 °C range |
| Gradient Range | 12-column linear gradient (max ΔT = 40 °C) |
| Dimensions (W × D × H) | 24.5 × 38.5 × 23 cm |
| Weight | 7.25 kg |
| Thermal Block Material | Anodized aluminum |
| Lid Temperature Control | SafeLid™ adaptive heated lid (up to 110 °C, pressure-adjustable) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Vacuum Centrifugal Concentrator |
| Model | Concentrator plus |
| Temperature Settings | 30 °C, 45 °C, 60 °C (±1 °C accuracy) |
| Sample Capacity | Up to 144 tubes (0.2–50 mL), microplates, or PCR plates |
| Noise Level | < 50 dB(A) |
| Pump Options | External vacuum source, integrated PTFE-coated diaphragm pump with cold trap, or integrated pump with auxiliary vacuum port |
| Rotor Compatibility | 15 interchangeable rotors |
| Heating Chamber | Chemically resistant stainless steel, induction-driven rotor motor |
| Brand | Eppendorf |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | BioFlo 320 |
| Working Volume | 0.6 – 10.5 L |
| Total Volume | 2.5 – 14.0 L |
| Aeration System | 1, 3, or 4 thermal mass flow controllers |
| pH Control Range | 2.0 – 12.0 |
| Dissolved Oxygen (DO) Control Range | 0 – 200% air saturation |
| Temperature Control Range | 5°C (cooling fluid inlet) to 90°C |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | BioFlo 720 |
| Price Range | USD 135,000 – 270,000 (based on configuration) |
| Reactor Type | Tower-style bioreactor |
| Vessel Volume Range | 50 L – 250 L |
| Construction Material | Electropolished stainless steel (AISI 316L) |
| Operating Pressure | Low-pressure system (max. 1.5 bar(g)) |
| Vacuum Capability | Not applicable |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | epMotion 5070/f |
| Plate Positions | 4 |
| Pipetting Accuracy | ±0.5 µL |
| Pipetting Range | 1–1000 µL |
| Sample Throughput | 4 plates per run |
| Dimensions | 65 × 48 × 63 cm |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Benchtop Refrigerated Centrifuge |
| Model | 5920 R |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 22,132 × g |
| Maximum Capacity | 4 × 1000 mL |
| Temperature Range | −11 °C to 40 °C |
| Dimensions (W × D × H) | 740 × 710 × 400 mm |
| Rotor Type | Horizontal (Swinging-Bucket) |
| Application Class | Biomolecular Separation |
| Compliance | IEC 61010-1, ISO 13485 (for medical device manufacturing), GLP/GMP-ready audit trail support via software |
| Brand | New Brunswick |
|---|---|
| Origin | USA |
| Model | NB Innova 40 R |
| Instrument Type | Refrigerated Temperature-Controlled Orbital Shaker |
| Timer Range | Continuous Operation |
| Oscillation Speed | 25–500 rpm |
| Orbit Diameter | 190 mm (standard), 250 mm (Innova 40 R) |
| Temperature Range | 5°C above ambient to 80°C |
| Platform | Single 46 × 46 cm stainless-steel shaker platform |
| Certifications | cETL, UL, CSA, CE |
| Sample Capacity | Up to three 3-L Erlenmeyer flasks simultaneously |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TransferMan 4r |
| Price Range | USD 13,500 – 40,500 (est. based on EUR/¥ conversion) |
| High-Voltage Range | Not applicable |
| Low-Voltage Range | Not applicable |
| Pulse Duration | Not applicable |
| Capacitance (µF) | Not applicable |
| Resistance | Not applicable |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Research Plus / Xplorer Plus |
| Instrument Type | Multichannel Electronic Pipette |
| Automation Level | Motorized |
| Channel Count | 16 or 24 |
| Volume Range | 1–100 µL |
| Maximum Capacity | 100 µL |
| Accuracy | ±0.1% at full scale |
| Brand | Calibre |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PiezoXpert |
| Pricing | Upon Request |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Type | Air-jacketed CO₂ incubated shaker |
| CO₂ Detection | Thermal Conductivity (TC) sensor |
| Temperature Range & Accuracy | +8 °C above ambient to 60 °C |
| CO₂ Concentration Range & Accuracy | 0.1–20% (±0.1% at 5% CO₂) |
| Humidity Control | Active dual-directional humidification, up to 85% rH, condensation-free operation |
| Chamber Capacity | 220 L |
| External Dimensions (W×D×H) | 77.3 × 131.8 × 80.5 cm |
| Brand | Eppendorf |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellXpert C170 |
| Temperature Range & Accuracy | +4 °C above ambient to 50 °C |
| Temperature Uniformity | ±0.25 °C at 37 °C |
| Humidity Range & Accuracy | 90–95 % RH at 37 °C |
| Chamber Capacity | 170 L |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer | Eppendorf AG |
| Product Type | Multichannel Manual Pipette |
| Channels | 8 or 12 |
| Volume Range | 0.5–300 µL |
| Maximum Volume | 300 µL |
| Accuracy | ±0.6% |
| Sterilization | Full-unit autoclavable (121 °C, 20 min, saturated steam) |
| Operating Principle | Air-displacement positive displacement with adjustable volume via dual-stage rotary dial |
| Ergonomic Certification | Compliant with ISO 8549-1:2021 (Ergonomics of manual pipetting) and PhysioCare Concept validated per DIN EN 614-1 |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DASbox Mini Bioreactor System |
| Temperature Range | 2–12 °C (external jacket control) |
| Working Volume Range | 0.06–0.25 L per vessel |
| Vessel Configuration | 1, 3, or 4 independent vessels |
| Gas Control | Four thermal mass flow controllers (MFCs) per vessel for air, O₂, CO₂, and N₂ |
| Sparging Options | Ring-type or microbubble spargers |
| pH/DO/Liquid Level Monitoring | Integrated electrochemical sensors with real-time feedback control |
| Sterilization Method | Autoclavable (121 °C, 20 min, saturated steam) |
| Agitation | Top-driven motor with interchangeable impellers (flat-blade, pitched-blade, marine propeller) |
| Cooling System | Water-free Peltier-based temperature regulation per vessel |
| Exhaust Condensation | Modular, tool-free, dry cold trap with one-click activation/deactivation |
| Feed Control | Peristaltic pumps with programmable speed and volumetric precision |
| Operational Modes | Batch, fed-batch, continuous, and perfusion culture |
Show next