| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000/VS-3000 |
| Instrument Type | Online Fixed-Mount Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Chemiluminescence (CLA), Magnetic Pressure (MPA), Electrochemical (Galvanic), Zirconia Oxide |
| Measurable Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Range | 0–5 ppm |
| Repeatability | ±0.5% of Full Scale |
| Resolution | 0.1 ppm |
| Response Time (T90) | ≤30 s |
| Zero Drift | ±2.0% of Full Scale per Week |
| Warm-up Time | 20–60 min (varies by sensor type) |
| Analog Output | DC 0–1 V / 4–20 mA (isolated optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | ~0.5 L/min |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Weight | ~20 kg (VA-3000) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | In-Line |
| Detection Principle | NDIR (CO, CO₂, CH₄, N₂O, SO₂), CLA (NOₓ), MPA / Electrochemical / Zirconia (O₂) |
| Minimum Detectable Range | 1–5 ppm (CH₄) |
| Repeatability | ±0.5% of Full Scale |
| Resolution | 0.01 ppm |
| Response Time | T90 ≤ 30 s |
| Zero Drift | ±2.0% of Full Scale per Week |
| Warm-up Time | 20–60 min (varies by sensor type) |
| Analog Output | DC 0–1 V / 4–20 mA (optional) |
| Communication Interface | RS-232C |
| Sample Flow Rate | ~0.5 L/min |
| Operating Environment | 0–40 °C, RH ≤ 90% non-condensing |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Dimensions (VA-3000) | 430 mm (W) × 132 mm (H) × 550 mm (D) |
| Weight (VA-3000) | ~20 kg |
| Compliance | Designed for ISO 14001-aligned monitoring, compatible with EPA Method 6C, EN 15267-certified configurations (per sensor module selection), supports GLP/GMP data integrity via timestamped analog output and serial logging |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Analyzer |
| Detection Targets | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Range | 1–5 ppm |
| Repeatability | ±5.0% of Full Scale |
| Resolution | 0.1 ppm |
| Response Time (T90) | ≤30 s |
| Zero Drift | ±2.0% of Full Scale per week |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) / Chemiluminescence (CLA) / Magnetic Pressure (MPA) / Electrochemical (Galvanic Cell) / Zirconia Oxide (ZrO₂) |
| Target Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Range | 1–5 ppm |
| Repeatability | ±0.5% of Full Scale (F.S.) |
| Resolution | 0.1 ppm |
| Response Time | T90 ≤ 30 s |
| Zero Drift | ±2.0% F.S./week |
| Warm-up Time | 20–60 min (gas-specific) |
| Analog Output | 0–1 V DC / 4–20 mA (non-isolated, optional) |
| Communication Interface | RS-232C |
| Sample Flow Rate | ~0.5 L/min |
| Operating Environment | 0–40 °C, ≤90% RH |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Weight | ~20 kg (VA-3000), ~14–20 kg (VS-3001–VS-3004) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 (Analyzer Unit) / VS-3000 (Sampling System) |
| Detection Principle | Non-Dispersive Infrared (NDIR), Chemiluminescence (CLA), Magnetic Pressure (MPA), Electrochemical (Galvanic Cell), Zirconia Oxide (ZrO₂) |
| Measured Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Accuracy | ±0.5% F.S. (Repeatability), ±1.0% F.S. (Linearity), ±2.0% F.S./week (Zero/Span Drift) |
| Response Time | T90 ≤ 30 s (single-component mode) |
| Analog Outputs | DC 0–1 V / 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Operating Temperature | 0–40 °C |
| Humidity | ≤90% RH |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| VA-3000 Dimensions | 430 × 132 × 550 mm (W×H×D) |
| Weight | ~20 kg |
| VS-3000 Sampling Units | VS-3001 to VS-3004 (modular configurations for NDIR/CLA/MPA/electrochemical/zirconia sensors) |
| Flow Rate | 0.5 L/min (sample inlet), 1.5–5.0 L/min (extraction) |
| Materials | SUS, PTFE, PVDF, FKM, glass |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 (Analyzer Unit) / VS-3000 (Sampling System) |
| Detection Principle | Non-Dispersive Infrared (NDIR), Chemiluminescence (CLA), Magnetic Pressure (MPA), Electrochemical (Galvanic), Zirconia |
| Repeatability | ±0.5% FS |
| Response Time (T90) | ≤30 s |
| Drift | ±2.0% FS/week (NDIR/CLA/MPA/ZrO₂), ±1.0% FS/day (Galvanic O₂) |
| Linearity | ±1.0% FS (≤10× range), ±1.5% FS (>10× range) |
| Warm-up Time | 20–60 min (varies by sensor type) |
| Analog Outputs | DC 0–1 V, 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min (analyzer inlet) |
| Operating Environment | 0–40 °C, RH ≤90% non-condensing |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Dimensions (VA-3000) | 430 × 132 × 550 mm (W×H×D) |
| Weight (VA-3000) | ~20 kg |
| Compliance | Designed for ISO 14001-aligned monitoring, compatible with EPA Method 6C/7E/10, EN 15267-certified system architecture (sensor modules), supports GLP/GMP data integrity via timestamped analog/digital output logging |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 (Analyzer Unit) / VS-3000 (Sampling System) |
| Instrument Type | Online Gas Analyzer |
| Target Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Detection Range | 1–5 ppm |
| Repeatability | ±0.5% F.S. |
| Linearity | ±1.0% F.S. (≤10× span) |
| Zero Drift | ±2.0% F.S./week (NDIR/CLA/MPA/Oxide Zirconia) |
| Span Drift | ±2.0% F.S./week |
| Response Time | T₉₀ ≤ 30 s (single-component mode) |
| Resolution | 0.1 ppm |
| Warm-up Time | 20–60 min (dependent on sensor type) |
| Analog Output | DC 0–1 V or 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min (analyzer inlet) |
| Operating Environment | 0–40 °C, ≤90% RH |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Power Consumption | ~200 VA (VA-3000), ~250–450 VA (VS-3000 variants) |
| Dimensions (VA-3000) | 430 × 132 × 550 mm (W×H×D) |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mountable chassis |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) / Chemiluminescence (CLA) / Magnetic Pressure (MPA) / Electrochemical (Galvanic) / Zirconia Oxide |
| Detectable Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Range | 1–5 ppm |
| Repeatability | ±0.5% FS |
| Linearity | ±1.0% FS (±1.5% FS for >10× span ratio) |
| Zero Drift | ±2.0% FS/week (±1.0% FS/day for galvanic O₂) |
| Span Drift | ±2.0% FS/week |
| Response Time | T₉₀ ≤ 30 s (single-component mode) |
| Resolution | 0.1 ppm |
| Analog Outputs | DC 0–1 V / 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min |
| Warm-up Time | 20–60 min (dependent on sensor type) |
| Operating Environment | 0–40 °C, RH < 90%, non-condensing |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Power Consumption | ~200 VA (VA-3000), ~250–450 VA (VS-3000 variants) |
| Enclosure | 19-inch rack-mount (430 × 132 × 550 mm, ~20 kg) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Fixed Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Chemiluminescence (CLA), Magnetic Pressure (MPA), Electrochemical (Galvanic), Zirconia |
| Measured Gases | CO, CO₂, CH₄, NOₓ, SO₂, N₂O, O₂, C₂H₄ (optional) |
| Minimum Detectable Range | 1–5 ppm (CH₄) |
| Repeatability | ±0.5% of Full Scale |
| Resolution | 0.01 ppm |
| Response Time | T₉₀ ≤ 30 s |
| Zero Drift | ±2.0% of Full Scale per Week |
| Warm-up Time | ~20 min (NDIR/MPA/ZrO₂), ~60 min (CLA/Galvanic) |
| Analog Outputs | DC 0–1 V or 4–20 mA (isolated optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Power Consumption | ~200 VA (VA-3000), ~250–450 VA (VS-3001–VS-3004) |
| Enclosure | 19-inch rack-mount (430 × 132 × 550 mm, ~20 kg) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-3000 / VS-3000 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR), Chemiluminescence (CLA), Magnetic Pressure (MPA), Electrochemical (Galvanic), Zirconia Oxide |
| Detectable Gases | CO, CO₂, NOₓ, SO₂, CH₄, N₂O, C₂H₄, O₂ |
| Minimum Range | 1–5 ppm |
| Repeatability | ±0.5% F.S. |
| Linearity | ±1.0% F.S. (≤10× span) |
| Zero Drift | ±2.0% F.S./week (NDIR/CLA/MPA/ZrO₂) |
| Span Drift | ±2.0% F.S./week (NDIR/CLA/MPA/ZrO₂) |
| Response Time | T₉₀ ≤ 30 s (single component, inlet to output) |
| Resolution | 0.1 ppm (for trace-level ranges) |
| Analog Output | DC 0–1 V (non-isolated), DC 4–20 mA (optional) |
| Digital Interface | RS-232C |
| Sample Flow Rate | ~0.5 L/min |
| Warm-up Time | ~20 min (NDIR/ZrO₂), ~40 min (MPA), ~60 min (CLA/Galvanic) |
| Operating Environment | 0–40 °C, ≤90% RH |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Power Consumption | ~200 VA (VA-3000), ~250–450 VA (VS-3001–VS-3004) |
| Dimensions (VA-3000) | 430 mm W × 132 mm H × 550 mm D |
| Weight (VA-3000) | ~20 kg |
| Enclosure | 19-inch rack-mountable chassis |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | VA-5000 |
| Detection Range | CO, CO₂, NOₓ, SO₂, CH₄, C₂H₄, N₂O, O₂ |
| Repeatability | ±1.0% F.S. |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA-5000/VS-5000 |
| Detection Principle | Non-Dispersive Infrared (NDIR) / Chemiluminescence (CLA) / Magnetic Pressure (MPA) / Electrochemical (Galvanic Cell) / Zirconia / Paramagnetic |
| Configuration | Rack-Mountable Online Analyzer |
| Response Time (T90) | ≤30 s |
| Repeatability | ±0.5% FS |
| Linearity | ±1.0% FS (≤10× range), ±1.5% FS (>10× range) |
| Zero/Span Drift | ±2.0% FS/week (NDIR, CLA, MPA, Zirconia, Paramagnetic) |
| Dynamic Range Ratio | Up to 20:1 (NDIR, optional), 100:1 (CLA) |
| Analog Outputs | Dual 0–1 V DC or 4–20 mA per module |
| Communication Interface | RS-232C |
| Sample Flow Rate | 0.5 L/min (analysis unit) |
| Operating Temperature | 0–40 °C |
| Power Supply | AC 100–120 V or 200–240 V, 50/60 Hz |
| Weight | ~20 kg (VA-5000), ~14–20 kg (VS-5001–VS-5004) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA/VS-3000 |
| Detection Principles | NDIR, Chemiluminescence (CLA), Magnetic Paramagnetic (MPA), Electrochemical (Galvanic), Zirconia |
| Zero/Span Drift | ±2.0% F.S./week (except Galvanic) |
| Repeatability | ±0.5% F.S. |
| Linearity | ±1.0% F.S. |
| Response Time (T90) | ≤30 s |
| Sample Flow Rate | 0.5 L/min (analyzer) / 1.5–5.0 L/min (preconditioning unit) |
| Measurement Ranges | CO (0–200 ppm to 0–100 vol%), CO₂ (0–100 ppm to 0–100 vol%), N₂O (0–100 ppm to 0–5000 ppm), CH₄ (0–200 ppm to 0–100 vol%), SO₂ (0–200 ppm to 0–10 vol%), NOₓ (0–20 ppm to 0–5000 ppm, CLA), O₂ (0–5 vol% to 0–25 vol%, MPA/Galvanic/Zirconia) |
| Range Switching | Up to 4 ranges (CLA: up to 8) |
| Analog Outputs | 0–1 V DC, 4–20 mA |
| Digital Interface | RS-232C |
| Warm-up Time | ~20 min (NDIR/Galvanic), ~40 min (Zirconia), ~60 min (CLA/MPA) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 100–350 VA (analyzer), 250–450 VA (VS unit) |
| Display | 320 × 240 pixel LCD |
| Enclosure | 19-inch rack-mount |
| Dimensions (VA) | 430 × 132 × 500 mm (W×H×D) |
| Dimensions (VS) | 430 × 221 × 550 mm |
| Operating Environment | 0–40 °C, ≤90% RH |
| Weight | ~14–20 kg (VS unit), ~20 kg (3-component VA unit) |
| Sample Conditioning | Integrated refrigerated cooler (5 °C dew point) |
| Sample Gas Requirements | Particulates ≤0.1 mg/m³, H₂O dew point ≤60 °C, Pressure fluctuation ±980 Pa |
| Wetted Materials | SUS, PP, PVC, PVDF, PTFE, FKM, CR, Glass |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | VA/VS-5000 |
| Instrument Type | Portable / Rack-Mountable |
| Detection Target | Multi-component gases |
| Minimum Range | 1–20 ppm |
| Repeatability | ±0.5% F.S. |
| Resolution | 0.1 ppm |
| Response Time | T90 ≤ 30 sec |
| Zero Drift | ±2.0% F.S./week (except galvanic cell) |
| Span Drift | ±2.0% F.S./week (except galvanic cell) |
| Linearity Error | ±1.0% F.S. |
| Sampling Flow Rate | ~0.5 L/min (analyzer) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% RH |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Power Consumption | 100–450 VA |
| Dimensions (VA unit) | 430 × 132 × 500 mm (W×H×D) |
| (VS unit) | 430 × 221 × 550 mm |
| Weight | ~14–20 kg |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XP-3110 |
| Price Range | USD 700–1,400 |
| Instrument Type | Portable |
| Detectable Gases | Combustible Gases (e.g., Methane, Propane, Butane, LPG, Town Gas) |
| Response Time | ≤45 s (T90) |
| Measurement Accuracy | ±5% of Full Scale |
| Measurement Ranges | 0–10% LEL and 0–100% LEL (auto-ranging) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hound-FR |
| Pricing | Available Upon Request |
| Brand | HPC |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Origin | Domestic (China) |
| Model | HPC-K9-1000-NX |
| Applicable Gases | N₂, Ar, He, Kr, Ne, CH₄ |
| Removed Impurities | H₂O, O₂, CO₂, CO, H₂, Organic Compounds |
| Purification Depth | < 1 ppb |
| Flow Rate Range | 200–20,000 Nm³/h |
| Operating Temperature | Ambient (15–35 °C) |
| Construction Material | Electropolished 316L Stainless Steel |
| Inlet/Outlet Filtration | 3 µm (0.003 mm) 316L Sintered Metal Filter |
| Adsorption Mechanism | Dual-mode (Chemical + Physical Adsorption) |
| Brand | HPC |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HPC-Q9-10-WY |
| Applicable Gases | C₂H₇N, C₂H₈N₂, CH₃SiH₃, GeH₄, SiH₄, SF₆, CSiH₆ |
| Impurities Removed | H₂O, O₂, CO₂, NMHCs |
| Purification Depth | <1 ppbV |
| Flow Rate Range | 2–2000 slpm |
| Operating Temperature | Ambient |
| Brand | HPC |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | HPC-Q9-1000-X |
| Applicable Gases | N₂, Ar, He, Kr, Ne, CH₄ |
| Impurities Removed | H₂O, O₂, CO₂, CO, H₂, Organic Compounds |
| Purification Depth | < 1 ppb |
| Flow Rate Range | 2–2000 slpm |
| Operating Temperature | Ambient |
| Brand | HPC |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HPC-Q9-120-X-V |
| Applicable Gases | N₂, Ar, He, Kr, Ne, CH₄ |
| Removed Impurities | H₂O, O₂, CO₂, CO, H₂, organic compounds |
| Purification Depth | < 1 ppb |
| Flow Rate Range | 2–2000 slpm |
| Operating Temperature | Ambient (15–35 °C) |
| Construction Material | 316L EP-grade stainless steel adsorption tube |
| Particulate Filtration | 0.003 µm 316L stainless steel sintered filter |
| Brand | Huironghe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Distributor |
| Country of Origin | China |
| Model | HRH-DRY2 |
| Price | Upon Request |
| Dimensions (D × L) | φ76 mm × 484 mm |
| Inlet/Outlet Tubing | One end 8×12 mm silicone tubing, other end 6.5×10 mm PU tubing |
| Chamber Material | High-transparency acrylic |
| Desiccant Type | Molecular sieve |
| Maximum Flow Rate | 4 L/min |
| Construction | Stainless steel semi-permeable tube core, acrylic housing |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Model | HK-7100A / HK-7101 |
| Instrument Type | Fixed Online Gas Detector |
| Detectable Gases | CH₄, CO₂, HC (hydrocarbons), and other combustible/toxic gases |
| Measurement Principle | Infrared (IR) and Catalytic Bead (Pellistor) |
| Response Time (T90) | ≤10 s (catalytic), ≤15 s (IR) |
| Accuracy | ±3% FS (full scale) |
| Measurement Range | CH₄: 0–100% LEL |
| CO₂ | 0–5000 ppm, 0–2%, 0–5%, or 0–100% vol (configurable) |
| Display | Dual-language OLED (Chinese/English) |
| Output Signal | 4–20 mA analog + optional RS485 Modbus RTU |
| Power Supply | DC 18–30 V (bus- or zone-powered) |
| Enclosure Rating | IP66 |
| Operating Temperature | −40 °C to +70 °C |
| Explosion Protection | Ex d II C T6 Gb |
| Compliance | GB 15322.1–2003 |
| Wiring | 3-wire or 4-wire |
| Power Consumption | ≤5 W |
| Atmospheric Pressure Range | 86–106 kPa |
| Transmission Distance | 4–20 mA ≤1000 m (2.5 mm² cable) |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Model | HK-7200A/7201 |
| Instrument Type | Fixed-mount (online) gas detector |
| Detectable Gases | HCN, CO, and other toxic gases |
| Response Time (T90) | ≤15 s |
| Measurement Accuracy | ±1% FS |
| Measurement Range | (0–100)% LEL |
| Detection Principles | Infrared (IR), Electrochemical (EC), Metal Oxide Semiconductor (MOS), Photoionization Detection (PID) |
| Display | Dual-language OLED (Chinese/English) |
| Output Signals | 4–20 mA analog + optional RS485 Modbus RTU |
| Power Supply | DC 18–30 V |
| Enclosure Rating | IP66 |
| Explosion Protection | Exd II CT6Gb |
| Compliance Standards | GB 15322.1–2003, GB 12358–2006 |
| Brand | Guangdong Huan Kai (BHK) |
|---|---|
| Origin | Guangdong, China |
| Model | ACS-150 |
| Total Sampling Volume | 0–9999 L |
| Main Flow Rate | 50–130 L/min (±5%) |
| Concentration Flow Rate | 5–15 L/min (±5%) |
| Flow Repeatability Error | ±2% |
| Inlet Load Capacity (with separator) | ≥2 kPa |
| Concentration Circuit Load Capacity | ≥50 kPa |
| Collection Efficiency (≥3 µm bioaerosols) | ≥80% |
| Collection Efficiency (≥0.5 µm bioaerosols) | ≥90% |
| Theoretical Concentration Ratio | 1:10 |
| Delay Setting Range | 0–9999 s |
| Auto-Sampling Duration | 0–9999 s |
| Programmed Sampling Duration per Cycle | 0–9999 s |
| Inter-Sampling Interval | 0–9999 s |
| Max Programmable Cycles | 255 |
| Collection Liquid Volume | 20 mL |
| Telescopic Tripod Height | 1.5 m (4 m optional) |
| Brand | Huan Kai (BHK) |
|---|---|
| Origin | Guangdong, China |
| Model | HKM-III A-100 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Duration | Up to 8 h |
| Operating Temperature | 0–65 °C |
| Relative Humidity | Ambient (non-condensing) |
| Culture Dish Diameter | 90 mm |
| Dimensions | 110 × 115 × 330 mm |
| Weight | 2.6 kg |
| Display | 3.5-inch HD capacitive touchscreen |
| Battery | Rechargeable polymer lithium-ion (up to 15 h continuous operation) |
| Data Storage | Up to 8,000 sampling records with timestamp, location code, volume, and operator ID |
| Connectivity | USB for PC data export via HKM Sampler Software |
| Compliance | ISO 14698-1 & -2, GB/T 16293-2010, GMP Annexes (EU & US), FDA 21 CFR Part 11-ready audit trail capability |
| Brand | Huan Kai (BHK) |
|---|---|
| Origin | Guangdong, China |
| Model | HKM-III |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2% |
| Sampling Duration | Up to 8 h |
| Operating Temperature | Ambient |
| Operating Humidity | Standard Range |
| Sample Collection Efficiency | ≥95% for particles 0.8–19.0 µm (per ISO 14698-1 Annex B & C) |
| Power Source | Rechargeable polymer lithium battery (≥8 h continuous operation) |
| Display | 3.5-inch HD capacitive touchscreen |
| Data Storage | 8,000 records with timestamp, location code, volume, and operator ID |
| Weight | 2.6 kg |
| Dimensions | 110 × 115 × 330 mm |
| Culture Dish Compatibility | 90 mm standard Petri dishes |
| Compliance | ISO 14698-1, ISO 14698-2 |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | APK-6100 |
| Dilution Ratio Range | 1:5 to 1:1500 |
| Flow Control | Triple High-Accuracy Mass Flow Controllers (MFCs) |
| Output Concentration Range | ppb–ppm level |
| Gas Path Material | Passivated Inert Surface (e.g., SilcoNert® or Sulfinert®-equivalent treatment) |
| Software Functionality | Automated Flow Calculation, Time-Based Volume Delivery, Method-Specific Protocol Storage |
| Compliance Readiness | ASTM D6196, ISO 6145-7, USP <621>, EPA TO-17 / TO-15 Support Framework |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | APK-6100C |
| Mixing Method | Dynamic Flow-Based Dilution |
| Instrument Type | Multi-Channel Dynamic Gas Dilutor |
| Dilution Ratio Range | Customizable (Standard Default: 1:500) |
| Dilution Accuracy | ±1% of set ratio |
| Flow Control | Four Independent High-Accuracy Mass Flow Controllers (MFCs) |
| Output Flow Capacity | Adjustable, Up to 10 L/min Total |
| Surface Treatment Option | Full-Scale Silanized Flow Path (Optional) |
| Gas Compatibility | Inorganic (SO₂, NOₓ, CO, O₃, NH₃) and Organic VOCs (e.g., benzene, formaldehyde, H₂S, mercaptans) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | APK 6100 |
| Pricing | Upon Request |
| Dilution Ratio | Up to 1500:1 (customizable) |
| Flow Control | Triple-channel Mass Flow Controllers (MFCs) |
| Display | Touchscreen Interface |
| Output Flow Range | 20–50 mL/min |
| Operating Pressure | Ambient (atmospheric) |
| Gas Compatibility | SO₂, NOₓ, CO, and other reactive/non-reactive calibration gases |
| Compliance | HJ 57–2017 (China) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | APK6100C |
| Flow Control Accuracy | ±0.8% FS (typical for integrated thermal mass flow controllers) |
| Dilution Ratio Range | 1:500 (customizable) |
| Minimum Output Concentration | Sub-ppb to ppm level (dependent on source gas purity and flow stability) |
| Gas Channels | 4 independent MFC-controlled inlets |
| Display | 7-inch capacitive touchscreen interface |
| Materials of Construction | Fully silanized stainless steel flow path (optional) |
| Compliance | Designed to support ISO 6145-7, ASTM D6348, EPA Method 205, and GLP/GMP-aligned calibration workflows |