| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 NC SOIL SPECIAL |
| Detection Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | Total Carbon (TC), Total Nitrogen (TN) |
| Optional Coupling | TIC DISCOVER for Total Inorganic Carbon (TIC) |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Column Temperature Range | 30–110 °C |
| Sample Types | Soils, Fertilizers, Sludges, Sediments, Plant Tissues |
| Automation Level | Fully Automated with Motorized/Pneumatic/Manual Sampler Options |
| Software Control | PC-based with Touchscreen Interface |
| Compliance Ready | Supports GLP/GMP audit trails, ASTM D5373, ISO 10694, USP <281>, EN 15936 |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7 |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Accuracy | < 0.0025% |
| Potential Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (2 × 10⁻¹⁸ A) |
| Small-Signal Rise Time | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Brand | Paeonia Innovations |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Instrument Type | Online |
| Wavenumber Range | 900–1800 cm⁻¹ |
| Dimensions | 50 × 55 × 60 mm |
| Weight | 450 g |
| Response Time | 0.3 s |
| Operating Pressure | 0–5 bar |
| Operating Temperature | −15 °C to +60 °C |
| Flow Path Fitting | 1/8″ NPT or Swagelok |
| Power Supply | 5 V DC via USB-C |
| Software Platform | Windows 10 & 11 Native Application for Real-Time Data Acquisition and Instrument Control |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Software Interface | Dedicated Windows-based acquisition and reporting software with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Isotope Interface | Integrated IDMicro EA port for coupling to isotope ratio mass spectrometers (IRMS) |
| Power & Gas Management | Standby mode reduces carrier gas consumption (He or Ar), energy use, and idle time |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (optional O) |
| Detection | Thermal Conductivity Detector (TCD), self-calibrating, reference-gas-free |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated microprocessor-controlled system with PC integration |
| Sample Introduction | Pneumatic and Zero-Blank electric autosamplers |
| Isotope Ratio Compatibility | Yes (MS-coupling enabled) |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S, O (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Capillary Chromatography (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control & PC Integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Configuration | Dual TCD with Reference-Free Operation |
| Software | Dedicated Windows-Based Acquisition & Quantification Suite with Audit Trail Capability |
| Compliance Framework | Designed for GLP/GMP environments |
| Power Supply | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 700 × 650 × 550 mm |
| Weight | ~75 kg |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Chromatographic Column (30–110 °C) |
| Automation Level | Semi-Automatic |
| Software Interface | PC-Connected Dedicated Data Acquisition & Processing Software |
| Isotope Compatibility | Yes (via external MS coupling) |
| Sample Type | Homogeneous Solid or Liquid Organic Samples (Micro-Weighing Compatible) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA) / ±0.2% of reading + ±0.1% of full scale (100 mA–3 A) / ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±2 aA (±2×10⁻¹⁸ A) |
| ADC Resolution | 32 bit |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic |
| Grounding Mode | Switchable floating/grounded |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Current Resolution | 2 × 10⁻¹⁸ A |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% @ 100 mΩ–10 MΩ |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Floating (for high-isolation applications, e.g., autoclaves, buried pipelines) |
| IR Compensation | Real-time automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| Software | Thales XT (real-time control, multi-channel visualization, offline analysis via Zahner Analysis) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7c |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Scan Range | ±14 V |
| Potentiostatic Range | ±5 V / ±14 V |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | 2 × 10⁻¹⁸ A |
| Input Impedance | >10 TΩ (HIZ option: 1000 TΩ) |
| AC Voltage Perturbation | 0–6 V (24-bit resolution) |
| AC Current Perturbation | 0–2 A (24-bit, 12 ranges) |
| Grounding Modes | Grounded & Floating |
| IR Compensation Range | 0–10 MΩ |
| Bandwidth | DC–6 MHz |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7x |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| EIS Frequency Range | 10 µHz – 12 MHz |
| Potentiostat Bandwidth | DC – 15 MHz |
| ADC Resolution | 32 bit |
| Input Impedance | >10 TΩ |
| Applied Potential Range | ±15 V |
| Cell Voltage Range | ±32 V |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (±2 × 10⁻¹⁸ A) |
| Output Current Accuracy | ±0.025% of reading ± 0.01% of FS (≥3 µA to 300 mA) |
| Rise Time (Small Signal) | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive EIS-based |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Software Platform | Zahner Lab (Windows 11, Linux, macOS compatible) |
| API Support | Python/C++ SDK included |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Squidstat Solo |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±100 mA |
| Current Accuracy | 0.2% of full scale, down to 20 nA |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Model | Squidstat Plus |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±0.2% of reading (typ.) |
| Potential Accuracy | ±300 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Current Resolution | 3 pA (at 1 A range) |
| Potential Resolution | 15 µV |
| Onboard Memory | 16 GB internal storage |
| Data Format | CSV export |
| Supported DC Techniques | CV, LSV, OCP, Tafel, CA, CP, DPV, NPV, SWV, RRDE, Staircase Voltammetry, GITT, PITT |
| Supported AC Techniques | Potentiostatic EIS, Galvanostatic EIS, Mott-Schottky (1/C² vs. E) |
| Battery Testing Modes | CC-CV, CC-CV-EIS, CP/CR, dQ/dV analysis, Coulombic & energy efficiency calculation |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Penta 5A |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±5 A |
| Current Accuracy | 0.1% of range, minimum 1 nA |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Current Resolution | down to 30 pA |
| Voltage Resolution | 15 µV |
| Voltage Accuracy | 0.1% of setpoint, minimum 1 mV |
| Input Impedance | 10 TΩ |
| Supported DC Techniques | CV, LSV, OCP, Tafel, CA, CP, DPV, NPV, SWV, Staircase Voltammetry, GITT, PITT |
| Supported AC Techniques | Potentiostatic EIS, Galvanostatic EIS, Mott-Schottky (1/C² vs. V) |
| Battery Testing Modes | CC-CV, CC-CV-EIS, CP/CR |
| Data Output | SOC, dQ/dV, Coulombic Efficiency, Energy Efficiency, Cycle Statistics, Capacity Statistics |
| Onboard Storage | 16 GB flash memory |
| Data Format | CSV (auto-saved, power-fail resilient) |
| Brand | Admiral Instruments |
|---|---|
| Origin | USA |
| Model | Squidstat Prime |
| Instrument Type | Multi-Channel Potentiostat/Galvanostat |
| Number of Channels | 4 Independent Channels |
| Voltage Range per Channel | ±10 V |
| Current Range per Channel | ±250 mA |
| Current Resolution | 750 fA (0.003% of range) |
| Voltage Resolution | 33 µV |
| Input Impedance | 10 TΩ |
| ADC Resolution | 16-bit |
| Maximum Sampling Rate | 40,000 samples/s |
| Onboard Memory | 16 GB |
| Electrode Configurations Supported | 2-, 3-, 4-, and 5-electrode cells |
| Cable Length | 90 cm |
| Operating Modes | Potentiostatic, Galvanostatic, Zero Resistance Ammeter (ZRA) |
| Grounding Options | Grounded or Floating |
| Electrochemical Techniques Supported | CV, LSV, OCP, Tafel, Potentiodynamic Polarization, CA, CC, CP, CR, DPV, NPV, SWV, Staircase Voltammetry, GITT, PITT, CC-CV Cycling, dQ/dV Analysis, Coulombic Efficiency Calculation, State-of-Charge (SOC) Tracking, Energy Efficiency Metrics, Charge/Discharge Time & Capacity Statistics |
| EIS Frequency Range | 10 µHz to 1 MHz (typical) |
| Current Accuracy | ±0.1% of full scale, down to 10 nA |
| Potential Accuracy | ±0.1% of full scale, within ±1 mV |
| Maximum Impedance Measurement | 5 GΩ (typical) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium Pro |
| Current Range | ±3 A |
| Current Resolution | ±2 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32 bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 0.0025%, 10,000 steps/decade |
| Impedance Measurement Range | 10 µΩ to 100 GΩ (depending on probe configuration) |
| IR Compensation | Real-time, adaptive |