| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 002‐001‐003 |
| Testing Principle | Timken EP Test (ASTM D2509, ASTM D2782, SH/T 0203) |
| Maximum Applied Load | 92,300 psi (on 0.022 in. wide Timken test block) |
| Rotational Speed | 800 rpm ± 5 rpm (adjustable up to 850 rpm) |
| Test Duration | 10 min ± 15 s |
| Temperature Control Range | Ambient to 120 °C (digital PID controller with fluid circulation system) |
| Oil Reservoir Capacity | 3 L (heated, pumped, valve-controlled |
| Grease Auto-Feeder Rate | 45 ± 9 g/min |
| Drive Motor | 2 HP, unidirectional, with RPM display |
| Load Application | Static load via 10:1 lever arm |
| Sample Types | Liquid lubricants and greases |
| Compliance | ASTM D2509, ASTM D2782, SH/T 0203 |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 001-001-331 |
| Test Type | Friction and Wear |
| Load Capacity (Standard) | 805 lbf |
| Load Capacity (Optional) | 1300 lbf |
| Speed Range | Programmable RPM Control |
| Temperature Range (Standard Chamber) | Ambient to 200 °C |
| Temperature Range (Pressurized Chamber, Optional) | Ambient to 250 °C |
| Sub-ambient Testing | Available with External Chiller |
| Friction Force Measurement Range (Standard) | 0–250 lbf |
| Friction Force Measurement Range (Optional Low-Load Sensor) | 0–25 lbf |
| Compliant Standards | ASTM D2714, D2981, D3704, D2509, D2782, G77 |
| Test Geometries | Block-on-Ring, Conforming Block-on-Ring, Timken Canted Cylinder, Chip-on-Ring, Ball-on-Ring |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BLB701 / BLB702 / BLB DIN |
| Product Type | Laboratory Instrument |
| Test Parameter | Low-Temperature Apparent Viscosity (ASTM D2983, IP 295, GB/T 6538) |
| Compliance | ASTM D2983, IP 295, GB/T 6538 |
| Dimensions (W×D×H) | 48 × 53 × 66 cm |
| Weight | ~68 kg |
| Voltage | 220 VAC, 50/60 Hz, Single Phase |
| Fuse Rating | BLB701: 10 A |
| BLB702 | 2 × 10 A |
| BLB-DIN | 12 A max |
| Cooling Capacity | 600 W at 0 °C, 300 W at −40 °C, 100 W at −70 °C |
| Heating Capacity | 600 W |
| Temperature Range | BLB701: 30 °C to −40 °C |
| BLB702 | 30 °C to −70 °C |
| BLB-DIN | 30 °C to −55 °C |
| Viewing Window | ~41 × 23 cm |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Safety Features | High-pressure cutoff, over-temperature limit, low-fluid-level detection and auto-shutdown |
| Certification | CE |
| Shipping Weight | 122–136 kg |
| Shipping Dimensions | 81 × 76 × 104 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TFAB |
| Product Type | Laboratory Instrument |
| Test Parameter | Foam Characteristics |
| Compliance Standards | ASTM D892, IP 146, ISO 6247 |
| Dimensions (W×D×H) | 61 × 61 × 53 cm |
| Weight | 72.5 kg |
| Power Supply | 220 V, Single-phase, 10 A, 50/60 Hz |
| Heating Medium | Forced Air |
| Motor | DC-driven, maintenance-free |
| Aeration Head | Stainless steel cylindrical head with pre-heated air supply |
| Air Flow System | Dual integrated mass flow meters |
| Air Flow Rate | 94–200 mL/min (±5 mL/min) |
| Temperature Range | 20–175 °C (±0.1 °C) |
| Test Programs | Four standardized sequences (I: 24 °C, II: 93.5 °C, III: 24 °C, IV: 150 °C) |
| Sample Volume | 200 mL |
| Test Capacity | Six 1000-mL graduated cylinders |
| Display | Touchscreen controller with real-time digital readouts, programmable alarms, and elapsed time tracking |
| Safety | Dual thermal protection (fuse + current-limiting fuse), CE certified |
| Shipping Weight/Dimensions | ~90 kg / 71 × 71 × 122 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS 3000 |
| Product Type | Laboratory Instrument |
| Test Parameter | HTHS Viscosity |
| Compliance Standards | ASTM D4683, ASTM D6616, SAE J300, GB/T 6538 |
| Dimensions (W × D × H) | 66 × 66 × 48 cm |
| Weight | 38.5 kg |
| Power Supply | 100–240 VAC, ≤6 A, 50/60 Hz |
| Viscosity Range | 1–30 mPa·s (cP) |
| Sample Volume | 40 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Auto-sampler Capacity | 1–40 samples per sequence |
| Temperature Control Setpoints | 80 °C, 100 °C, 150 °C (±0.1 °C) |
| Shear Rate Range | 5×10⁵ s⁻¹ to 3×10⁶ s⁻¹ (dependent on fluid viscosity and temperature) |
| Display | Digital touchscreen interface |
| Safety Features | Automatic torque motor and stator heater shutdown upon power interruption |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TanEV WCT |
| Product Type | Laboratory Instrument |
| Compliance | SAE J3200 (in development), ASTM method under preparation |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 000-001-305 |
| Test Method Compliance | ASTM D2670, D2625, D3233, D5620 |
| Load Range | 200–3000 lbf (±2% FS) |
| Rotational Speed | 290 ± 10 rpm |
| Torque Measurement | 0–100 in-lb (±2% FS) |
| Wear Resolution | 0.001 inch (0.025 mm) per 14.4 ratchet clicks |
| Operating Temperature | Ambient to 100 °C |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ETM |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 100–1650 N |
| Maximum Contact Pressure | 3.5 GPa (standard steel test specimens) |
| Sliding Velocity | up to 3.5 m/s |
| Temperature Range | 10–150 °C |
| Sample Volume | 30 mL (10 mL with optional filler insert) |
| Operating System | Windows 10 |
| Safety Features | Dual PT100 RTD temperature monitoring, emergency stop button, interlocked lubricant reservoir lid |
| Power Supply | 100–240 V, 50/60 Hz, 1600 VA |
| Weight (main unit) | 52 kg |
| Dimensions (H × W × D) | 425 mm × 400 mm × 605 mm |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Laboratory Instrument |
| Model | SB+2 |
| Application Scope | Lubricating Oil & Low-Temperature Fluid Characterization |
| Compliance Standards | ASTM D5133, D7110, D2983, D4684, D445, D97, D2500 |
| Temperature Range | +30 °C to –70 °C |
| Temperature Control Accuracy | ±0.1 °C (programmed), ±0.03 °C (manual) |
| Cooling Rate | 1 °C/h (for Brookfield Scan/Gel Index), Isothermal for Brotz–Feldt Viscosity |
| Bath Medium | Methanol (temperature-dependent) |
| Dimensions (W×D×H) | 48 × 61 × 69 cm |
| Net Weight | ~86 kg |
| Power Supply | 220 VAC, 50/60 Hz |
| Safety Certifications | CE |
| Transport Weight (Bath Unit) | ~123 kg |
| Transport Dimensions (Bath Unit) | 66 × 59 × 122 cm |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TanEV CDT |
| Product Type | Laboratory Instrument |
| Compliance Standards | ASTM D8544, SAE J3200 |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 081-001-005 |
| Test Principle | Oscillating Ball-on-Cylinder Tribometry |
| Applied Load | 2450 N (550 lbf) |
| Test Duration | 22 h |
| Oscillation Frequency | 30.0 Hz (1800 cpm) |
| Compliance Standards | ASTM D4170, SH/T 0716 |
| Optional Feature | Load Uniformity Adjustment System |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | MRV TP-1 |
| Standards Compliance | ASTM D4684 (Method A), SH/T 0562 |
| Temperature Range (BLB702) | 30 °C to −70 °C |
| Cooling Power | 600 W at 0 °C, 100 W at −40 °C, 300 W at −70 °C |
| Heating Power | 600 W |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Dimensions (W×D×H) | 48 cm × 53 cm × 66 cm |
| Net Weight | ~68 kg |
| Transport Weight | 122–136 kg |
| Transport Dimensions | 81 cm × 76 cm × 104 cm |
| Electrical Supply | 220 VAC, 50/60 Hz, Single Phase |
| Safety Certifications | CE, High-Temp Cut-off, Low-Level Fluid Detection, Over-Pressure Breaker |
| Viewing Window | 41 cm × 23 cm |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | MTM2 |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Sample Volume | 10–35 mL |
| Load Range | 0–75 N |
| Contact Pressure Range | 0–1.25 GPa (standard test geometry) |
| Sliding/Rolling Velocity | −4 to +4 m·s⁻¹ |
| Temperature Range | Ambient to 150 °C (sub-ambient operation supported via external refrigerated oil bath) |
| Power Supply | 100–240 V AC, 50/60 Hz, 750 VA |
| Host Weight | 30 kg |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MPR |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 0–2000 N |
| Contact Pressure | 0–3.2 GPa |
| Sliding/Rolling Ratio | 0–200% |
| Temperature Range | Ambient to 150 °C |
| Specimen Volume | 150 mL |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | NOACK S2 |
| Price | Upon Request |
| Category | Laboratory Instrument |
| Test Parameter | Evaporation Loss of Lubricating Oils |
| Compliance Standard | ASTM D5800 |
| Dimensions (W×D×H) | 55 × 40 × 33 cm |
| Weight | 33.85 kg |
| Voltage | 220 V |
| Frequency | 50/60 Hz |
| Heating Method | Solid-State Metal Heater (Wood’s Metal-Free) |
| Vacuum System | Integrated Vacuum Pump with Automatic Control |
| Vacuum Level | 20 mm H₂O |
| Test Temperature | 250 °C (±0.1 °C accuracy) |
| Test Duration | 60 min |
| Safety Features | Over-Temperature Protection, Heat-Shield Enclosure |
| Certification | CE |
| Data Output | RS232 Serial Interface for Printer |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 016-001-002 |
| Test Method Compliance | ASTM D3336, SH/T 0428 |
| Maximum Rotational Speed | 20,000 rpm (light-load condition) |
| Axial Load Capacity | 15 lbs (mechanically applied) |
| Heating Chamber Max Temperature | 371 °C |
| Torque Measurement | Digital display with high/low torque shutdown threshold |
| Drive Motor | Dual 1 HP, single-phase AC motors with thermal protection |
| Timing Control | Digital on/off elapsed-time counter |
| Standard Shaft | CRC-type shaft |
| Application Focus | Grease-lubricated ball bearing life evaluation under accelerated thermal–mechanical stress |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 089-001-001 |
| Testing Mode | Wear, Extreme Pressure (EP), and KRL Rolling Fatigue |
| Speed Range | 1–2500 rpm |
| Load Range | 1–1000 kg (standard) |
| optional low-load system | 0–150 ±0.2 kg |
| Compliance | ASTM D2266, D4172, D5183, D2596, D2783 |
| Safety | Interlocked pneumatic loading enclosure |
| Control | Touchscreen interface with programmable cycle counter and elapsed time timer |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 006‐001‐330 |
| Testing Type | Friction and Wear |
| Compliance | ASTM D3702, D2266, D4172, D5183, G99 |
| Speed Range | 30–3600 rpm (standard), 0.01–10,000 rpm (with optional gear reducer) |
| Load Range | 1–160 lbf (2:1 lever), 20–800 lbf (10:1 lever) |
| Temperature Range | Ambient to 150°C (standard), 30–200°C (with optional heating/cooling modules) |
| Control | Computer-controlled servo motor, pneumatic auto-loading (programmable), real-time torque & displacement monitoring |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | EHD2 |
| Pricing | Upon Request |
| Product Type | Laboratory Instrument |
| Test Parameters | Oil Film Thickness (1–1000 nm), Traction Coefficient (Friction Coefficient) |
| Load Range | 0–50 N |
| Contact Pressure Range | 0–0.7 GPa (Steel Ball–Glass Disk) / 0–3 GPa (WC Ball–Sapphire Disk) |
| Sliding/Rolling Ratio | 0–100% |
| Linear Speed | 0–4 m/s |
| Temperature Range | Ambient to 150 °C |
| Sample Volume | 120 mL |