Empowering Scientific Discovery

Global Analytical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
ModelCP610
Temperature Range–70 °C to +30 °C
Temperature Control Accuracy±0.1 °C
Cooling Capacity600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C
Cooling Rate~30 °C/h (average)
Sample Capacity4-position rotating bath
Bath Volume3.8 L
Dimensions42 × 53 × 66 cm
Weight~68 kg
Power Supply220 V, 10 A, 50/60 Hz, single-phase
ComplianceASTM D97, ASTM D2500, ISO 3016, ISO 2084, IP 15, GB/T 6986, GB/T 3536
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
Model002‐001‐003
Testing PrincipleTimken EP Test (ASTM D2509, ASTM D2782, SH/T 0203)
Maximum Applied Load92,300 psi (on 0.022 in. wide Timken test block)
Rotational Speed800 rpm ± 5 rpm (adjustable up to 850 rpm)
Test Duration10 min ± 15 s
Temperature Control RangeAmbient to 120 °C (digital PID controller with fluid circulation system)
Oil Reservoir Capacity3 L (heated, pumped, valve-controlled
Grease Auto-Feeder Rate45 ± 9 g/min
Drive Motor2 HP, unidirectional, with RPM display
Load ApplicationStatic load via 10:1 lever arm
Sample TypesLiquid lubricants and greases
ComplianceASTM D2509, ASTM D2782, SH/T 0203
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
Model001-001-331
Test TypeFriction and Wear
Load Capacity (Standard)805 lbf
Load Capacity (Optional)1300 lbf
Speed RangeProgrammable RPM Control
Temperature Range (Standard Chamber)Ambient to 200 °C
Temperature Range (Pressurized Chamber, Optional)Ambient to 250 °C
Sub-ambient TestingAvailable with External Chiller
Friction Force Measurement Range (Standard)0–250 lbf
Friction Force Measurement Range (Optional Low-Load Sensor)0–25 lbf
Compliant StandardsASTM D2714, D2981, D3704, D2509, D2782, G77
Test GeometriesBlock-on-Ring, Conforming Block-on-Ring, Timken Canted Cylinder, Chip-on-Ring, Ball-on-Ring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTBS2100E-F / TBS3000
PriceUpon Request
Dimensions (Viscometer)18 × 30.5 × 35.5 cm
Dimensions (Control Unit)46 × 46 × 15 cm
Dimensions (Auto-sampler, optional)46 × 51 × 61 cm
Weight (Viscometer)15.5 kg
Weight (Control Unit)9 kg
Weight (Auto-sampler)25.4 kg
Voltage220–240 V AC
Frequency50/60 Hz
Sample Volume50 mL (recommended)
Test Duration per Sample~5–7 min
Temperature Range40 °C to 200 °C (±0.1 °C stability)
Shear Rate Range5×10⁴ s⁻¹ to 7×10⁶ s⁻¹
Speed Steps12 discrete settings (800–8000 rpm)
Overtemperature ProtectionProgrammable safety limit
ComplianceCE-marked
Shipping Weight (Manual System)68 kg
Shipping Weight (Auto System)72.5 kg
Shipping Dimensions (Manual)61 × 81 × 89 cm
Shipping Dimensions (Auto)61 × 81 × 127 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBLB701 / BLB702 / BLB DIN
Product TypeLaboratory Instrument
Test ParameterLow-Temperature Apparent Viscosity (ASTM D2983, IP 295, GB/T 6538)
ComplianceASTM D2983, IP 295, GB/T 6538
Dimensions (W×D×H)48 × 53 × 66 cm
Weight~68 kg
Voltage220 VAC, 50/60 Hz, Single Phase
Fuse RatingBLB701: 10 A
BLB7022 × 10 A
BLB-DIN12 A max
Cooling Capacity600 W at 0 °C, 300 W at −40 °C, 100 W at −70 °C
Heating Capacity600 W
Temperature RangeBLB701: 30 °C to −40 °C
BLB70230 °C to −70 °C
BLB-DIN30 °C to −55 °C
Viewing Window~41 × 23 cm
Sample Capacity12-position bath
Bath Volume3.8 L
Safety FeaturesHigh-pressure cutoff, over-temperature limit, low-fluid-level detection and auto-shutdown
CertificationCE
Shipping Weight122–136 kg
Shipping Dimensions81 × 76 × 104 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTFAB
Product TypeLaboratory Instrument
Test ParameterFoam Characteristics
Compliance StandardsASTM D892, IP 146, ISO 6247
Dimensions (W×D×H)61 × 61 × 53 cm
Weight72.5 kg
Power Supply220 V, Single-phase, 10 A, 50/60 Hz
Heating MediumForced Air
MotorDC-driven, maintenance-free
Aeration HeadStainless steel cylindrical head with pre-heated air supply
Air Flow SystemDual integrated mass flow meters
Air Flow Rate94–200 mL/min (±5 mL/min)
Temperature Range20–175 °C (±0.1 °C)
Test ProgramsFour standardized sequences (I: 24 °C, II: 93.5 °C, III: 24 °C, IV: 150 °C)
Sample Volume200 mL
Test CapacitySix 1000-mL graduated cylinders
DisplayTouchscreen controller with real-time digital readouts, programmable alarms, and elapsed time tracking
SafetyDual thermal protection (fuse + current-limiting fuse), CE certified
Shipping Weight/Dimensions~90 kg / 71 × 71 × 122 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
ModelKV801 / KV802 / KV803
Temperature RangeKV801: +30 °C to –40 °C
KV802+30 °C to –70 °C
KV803+40 °C to 150 °C
Temperature Stability±0.1 °C (digital) / ±0.01 °C (analog) for KV801/KV802
Cooling Capacity600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C
Heating Capacity1500 W (KV803 only)
Bath Volume~11.5 L
Sample Capacity4 capillary viscometers (KV801/KV802), 6 capillary viscometers (KV803)
Dimensions (W×D×H)42 cm × 53 cm × 66 cm
Net Weight~68 kg
Shipping Weight122–136 kg
Shipping Dimensions (W×D×H)81 cm × 76 cm × 104 cm
Power SupplyKV801/KV802: 208–220 V, 10 A, 50/60 Hz
KV803220 V, 8 A, 50/60 Hz
RefrigerantsR410A (KV801), R507/R508B (KV802)
Compressor1/3 HP
Viewing Window41 cm × 23 cm
ComplianceASTM D445, GB/T 265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
ModelFAL400
ComplianceASTM D3241, IP 323, GB/T 9169
Heating Tube CertificationASTM D3241 Table 2 Note c, IP 323 Table A.1
AutomationFully automated air purge (1.5 L/min), pre-test pump priming (60 s), flow verification at start/end
Pump SystemDual HPLC-grade precision pumps, pulse-free flow delivery
Control SystemEmbedded microprocessor (non-Windows), corrosion-resistant color touchscreen
SafetyInterlocked safety shield with real-time alarm
FiltrationIntegrated activated carbon fume scrubber
Optional AccessoryFAL430 Deposit Rating Ellipsometer (ellipsometric thickness & 3D topography measurement)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTBS 3000
Product TypeLaboratory Instrument
Test ParameterHTHS Viscosity
Compliance StandardsASTM D4683, ASTM D6616, SAE J300, GB/T 6538
Dimensions (W × D × H)66 × 66 × 48 cm
Weight38.5 kg
Power Supply100–240 VAC, ≤6 A, 50/60 Hz
Viscosity Range1–30 mPa·s (cP)
Sample Volume40 mL (recommended)
Test Duration per Sample~5–7 min
Auto-sampler Capacity1–40 samples per sequence
Temperature Control Setpoints80 °C, 100 °C, 150 °C (±0.1 °C)
Shear Rate Range5×10⁵ s⁻¹ to 3×10⁶ s⁻¹ (dependent on fluid viscosity and temperature)
DisplayDigital touchscreen interface
Safety FeaturesAutomatic torque motor and stator heater shutdown upon power interruption
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPCS Instruments
OriginUnited Kingdom
ModelABS
Power Supply100–230 V AC, 750 VA
Operating Temperature15–35 °C
Operating Humidity20–80 % RH (non-condensing)
Weight34 kg
DimensionsNot specified
Compressed Air RequirementASTM D5001-compliant (≤0.1 ppm hydrocarbons), dry and oil-free
Deionized Water Reservoir Capacity~1000 tests per fill
ControlMicroprocessor-based, fully automated
Environmental ComplianceDesigned for ISO/IEC 17025-aligned laboratories
Software InterfacePC-based control and data logging with audit-trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
Model450-001-002
Heating Tube Temperature Range300–450 °C
Temperature Control Accuracy±2 °C
Flow Rate Range0.55–10.0 mL/min
Pressure Range0–200 psi
Test Duration2.5–500 hours
Sample Reservoir Temperature100–210 °C
Sample Volume100 mL–1 L
ComplianceSAE ARP 5996B, SAE AS5780
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas&King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTanEV WCT
Product TypeLaboratory Instrument
ComplianceSAE J3200 (in development), ASTM method under preparation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
Model000-001-305
Test Method ComplianceASTM D2670, D2625, D3233, D5620
Load Range200–3000 lbf (±2% FS)
Rotational Speed290 ± 10 rpm
Torque Measurement0–100 in-lb (±2% FS)
Wear Resolution0.001 inch (0.025 mm) per 14.4 ratchet clicks
Operating TemperatureAmbient to 100 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPCS Instruments
OriginUnited Kingdom
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelETM
Product TypeLaboratory Instrument
Test ParameterFriction and Wear
Load Range100–1650 N
Maximum Contact Pressure3.5 GPa (standard steel test specimens)
Sliding Velocityup to 3.5 m/s
Temperature Range10–150 °C
Sample Volume30 mL (10 mL with optional filler insert)
Operating SystemWindows 10
Safety FeaturesDual PT100 RTD temperature monitoring, emergency stop button, interlocked lubricant reservoir lid
Power Supply100–240 V, 50/60 Hz, 1600 VA
Weight (main unit)52 kg
Dimensions (H × W × D)425 mm × 400 mm × 605 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas&King
OriginUSA
Manufacturer StatusAuthorized Distributor
Product CategoryImported Laboratory Instrument
ModelSB+2
Application ScopeLubricating Oil & Low-Temperature Fluid Characterization
Compliance StandardsASTM D5133, D7110, D2983, D4684, D445, D97, D2500
Temperature Range+30 °C to –70 °C
Temperature Control Accuracy±0.1 °C (programmed), ±0.03 °C (manual)
Cooling Rate1 °C/h (for Brookfield Scan/Gel Index), Isothermal for Brotz–Feldt Viscosity
Bath MediumMethanol (temperature-dependent)
Dimensions (W×D×H)48 × 61 × 69 cm
Net Weight~86 kg
Power Supply220 VAC, 50/60 Hz
Safety CertificationsCE
Transport Weight (Bath Unit)~123 kg
Transport Dimensions (Bath Unit)66 × 59 × 122 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas&King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTanEV CDT
Product TypeLaboratory Instrument
Compliance StandardsASTM D8544, SAE J3200
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
Model081-001-005
Test PrincipleOscillating Ball-on-Cylinder Tribometry
Applied Load2450 N (550 lbf)
Test Duration22 h
Oscillation Frequency30.0 Hz (1800 cpm)
Compliance StandardsASTM D4170, SH/T 0716
Optional FeatureLoad Uniformity Adjustment System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPCS Instruments
OriginUnited Kingdom
ModelHFRR
Frequency Range10–200 Hz
Stroke Range20 µm–2.0 mm
Load Capacity0–1.0 kg (via calibrated weights)
Maximum Friction Forceup to 10.0 N (amplitude-dependent)
Operating Temperatureambient to 150 °C (up to 400 °C with optional high-power heating module)
Standard Counterface10.0 mm diameter × 3.0 mm thick steel disc
Standard Indenter6.0 mm diameter hardened steel ball
ComplianceASTM D6079, ASTM D7688, ISO 12156-1, SH/T 0765–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelQuantum
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: CFR
OriginUSA
ModelF1/F2
ApplicationGasoline Octane Number (RON/MON) Determination
ConfigurationBenchtop
Standards ComplianceASTM D2699, ASTM D2700, ISO 5164, ISO 5163, GB/T 5487, GB/T 503
Compression Ratio Range4:1 to 18:1 (continuously adjustable)
Ignition Timing13° BTDC (capacitor discharge system)
Knock DetectionFactory-calibrated analog knock meter (0–100 scale), magnetic reluctance sensor mounted in combustion chamber
LubricationPressure-fed, external oil pump with filtration, cooling, and flow monitoring
Cooling SystemThermosiphon jacketed cylinder with boiling/condensation recirculation
Air Intake Humidity Control25–50 g H₂O per lb dry air (ASTM-compliant)
Safety InterlocksLow oil pressure, low coolant pressure, low voltage, motor overload
Drive MotorThree-phase synchronous/reluctance motor (constant-speed operation)
CarburetorSingle-venturi, level-viewable fuel bowl
Cylinder HeadMonolithic, integrated design for thermal stability and measurement repeatability
CrankcaseCFR 48D cast iron box-type, service-accessible side and gear covers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTBR
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
ModelMRV TP-1
Standards ComplianceASTM D4684 (Method A), SH/T 0562
Temperature Range (BLB702)30 °C to −70 °C
Cooling Power600 W at 0 °C, 100 W at −40 °C, 300 W at −70 °C
Heating Power600 W
Sample Capacity12-position bath
Bath Volume3.8 L
Dimensions (W×D×H)48 cm × 53 cm × 66 cm
Net Weight~68 kg
Transport Weight122–136 kg
Transport Dimensions81 cm × 76 cm × 104 cm
Electrical Supply220 VAC, 50/60 Hz, Single Phase
Safety CertificationsCE, High-Temp Cut-off, Low-Level Fluid Detection, Over-Pressure Breaker
Viewing Window41 cm × 23 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas&King
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSBT DC-II
PricingUpon Request
Dimensions (W×D×H)32 × 51 × 74 cm
Weight~36.3 kg
Power Supply220–240 VAC, 50/60 Hz
Cooling Range+90 °C to –45 °C (±0.1 °C stability)
Max. Cooling Rate60 °C/h
Heating CapabilityUp to 90 °C
Sample Capacity2 simultaneous tests
ControlSingle PC can manage up to 4 units
Safety CertificationsCE compliant
Transport Dimensions~81 × 76 × 104 cm
Transport Weight~125 kg
Compliant StandardsASTM D5133, ASTM D7110, ILSAC GF-2 through GF-6 (A&B), API SL/SM/SN, GB 11121, SH/T 0732, JPI-5S-56-99
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCFR
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelCFR F-5
ConfigurationBenchtop
Measurement ParameterDiesel Cetane Number
Compliance StandardASTM D613, GB/T 386–1991, ASTM D975 (Arbitration Method)