BrandSyrris
OriginUnited Kingdom
ModelAtlas-sodium
Vessel Capacities100, 160, 300, 450 mL
Construction MaterialStainless Steel 316 (standard), optional Hastelloy or Titanium
Maximum Operating Pressure200 bar
Maximum Temperature250 °C
Mechanical Stirring Speedup to 800 rpm
Magnetic Stirring Speedup to 1200 rpm
Pressure ControlAutomated via integrated pressure control module
Gas SelectionUp to 3 gases, switchable via front panel or PC software
Safety CertificationPED 2014/68/EU and ASME Section VIII compliant
Data LoggingReal-time recording of temperature, pressure, stirring speed, gas selection status, and event timestamps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSyrris
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAtlas SonoLab
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSyrris
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAsia Flow Photochemical Reactor
PriceUpon Request
Temperature Range−40 °C to +80 °C (requires optional Asia Heater or Asia Cryo Controller)
Temperature Control AccuracySetpoint accuracy ±1 °C, Display resolution 0.1 °C
Reaction ModulesUp to 8 interchangeable high-power LED modules (monochromatic, multi-wavelength, or blank)
Wavelength Options365, 385, 405, 420, 450, and 525 nm
Reaction Volume4 mL or 16 mL per module
Light Power OutputAdjustable from 10% to 100%, up to 120 W total system output
Photonic Flux MonitoringReal-time intensity and photon flux display
SafetyFully interlocked housing with zero-light-leak design
CompatibilityStandalone operation or integrated into Syrris Asia flow chemistry platform
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSyrris
OriginUnited Kingdom
ModelAtlas
Calorimetry ModesHeat Flow Calorimetry (HFC) & Power Compensation Calorimetry (PCC)
Reactor TypeTriple-walled vacuum-jacketed vessel
Volume Range250 mL – 2 L
Temperature Range−40 °C to +200 °C
Temperature Accuracy±0.1 °C (dependent on external circulator performance)
Max. PCC Power Compensation50 W
Max. HFC Energy Density100 W/L
Calorimetric Accuracy1–5% (subject to experimental conditions and integration time)
Sensitivity<0.1 W/kg
Mechanical Stirring0–800 rpm
Magnetic Stirring0–1200 rpm
Gas HandlingInert gas purging, vacuum & pressure operation capable
Optional ModulesGravimetric & volumetric dosing systems (balances, syringe pumps, peristaltic pumps), in-line FTIR, turbidity/ particle size analyzers for crystallization studies, pH probes with automated pH control