Empowering Scientific Discovery

GOW-MAC Instrument Co.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTiger HALO 3 H₂O
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 582
Instrument TypeLaboratory Gas Chromatograph
Temperature Control Range0–450 °C
Oven Ramp Rate0.1–50 °C/min
Cool-down Time~4 min (450 °C to 10 °C)
Carrier Gas Flow Range & Control0–45 mL/min
Carrier Gas Pressure Range & Control0–120 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–120 kPa
Injector Total Flow Setting Range0–45 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 836 Series
Instrument TypeLaboratory Gas Chromatograph
Column ConfigurationUp to 8 Valves & 10 Columns
Oven Temperature RangeAmbient +4°C to 450°C
Max Ramp Rate120°C/min
Cooling Time450°C to 50°C in ≤4 min
Temperature Resolution0.1°C
Oven Program Steps20–21 ramps
Detector CapacityUp to 3 Independent, Thermally Controlled Detectors
Detector OptionsDID, TCD, FID, PID, FPD, NPD
Flow ControlElectronic Pressure Control (EPC)
Dimensions58 cm × 54 cm × 56 cm
Detection Limits5 ppb (CH₄, DID), 20 ppb (CH₄, FID), 2×10⁻⁹ g/mL (CₙHₘ, TCD), 1×10⁻¹² g (C₆H₆, PID), 50 ppb avg. (FPD), 10 ppb avg. (NPD)
Response Times<0.5 s (DID, TCD, PID), 1 ms (FID)
Linear Dynamic Ranges10⁴–10⁷ (detector-dependent, log-log scale)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 200
Instrument TypeOnline Gas Chromatograph
Detector OptionsTCD, DID, FID, PID, NPD, FPD
Column CompatibilityPacked & Micro-packed Columns
Sample IntroductionGas Sampling Valve & Liquid Sampling Valve
Valve ConfigurationUp to 3 Pneumatically Actuated Valves
Oven Temperature Range+10 °C to 150 °C
SoftwareClarity PC Chromatography Data System (CDS)
ConstructionStainless Steel Flow Path
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 1300
Instrument TypeLaboratory Gas Chromatograph
Temperature Control Range0–450 °C
Ramp Rate0.1–40 °C/min
Cooling Rate450 °C to 10 °C in ~5 min
Carrier Gas Flow Range & Control0–30 mL/min
Carrier Gas Pressure Range & Control0–100 kPa
Injector Max Operating Temperature450 °C
Injector Pressure Setpoint Range0–100 kPa
Injector Total Flow Setpoint Range0–30 mL/min
Detection Limit10 ppb (N₂ in He)
Detection PrincipleHelium Plasma Emission Spectroscopy
Output Signal4–20 mA analog + dry contact alarms
Configuration Options0–2/0–20 ppm or 0–20/0–200 ppm dual-range modes
Power Options115 V AC or 230 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelMIDAC Dynamic Calibration System
Price RangeUSD 42,000 – 70,000 (FOB)
Instrument TypeLaboratory Gas Chromatography Calibration Standard Generator
Application ScopeUniversal Calibration for GC & FTIR
Gas Dilution StagesTriple-stage
Mass Flow Controllers (MFCs)Multi-channel digital MFC support
Corrosive Gas CompatibilityYes (acidic, alkaline, organic)
Dilution Ratio ProgrammabilityYes, time-scheduled auto-run
Real-time Flow MonitoringYes
Repeatability≤ ±0.8% RSD (N₂ baseline, 10–1000 sccm)
Control InterfacePLC-based with 7″ TFT touchscreen (800×600)
PLC Cycle TimeStandard mode 160 µs
Onboard MemoryDisplay buffer 26 MB
Touchscreen Lifetime≥ 5 years (MTBF)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGM 816 TCD
Instrument TypeLaboratory Gas Chromatograph
Detector TypeThermal Conductivity Detector (TCD)
Application ScopeUniversal for Specialty Gas Analysis
Dimensions (with valve box)82 × 54 × 48.5 cm
Dimensions (without valve box)58 × 54 × 48.5 cm
Analog OutputsDual-channel (1 mV and 1 V)
Column Configuration SupportUp to 10 columns and 7 valves
Baseline CompensationSingle-column dual-channel
Corrosion-Resistant Gas PathwayYes
Diagnostic CapabilitiesReal-time circuit, temperature, and leak diagnostics with automated error alerts and remediation guidance
SoftwareCustomizable chromatography software package supporting remote instrument control, data acquisition, processing, and report generation
Remote AccessBrowser-based UI for method/sequence editing, system log access, and real-time status monitoring
Compliance ContextDesigned for GLP/GMP-aligned environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model75-902
Operating Temperature Range0–250 °C
Maximum Working Pressure300 atm
Sample Gas Flow Rate30–50 mL/min
Power Supply230 VAC, 500 W
Dimensions (D×W×H)39.37 cm × 16.51 cm × 30.48 cm
Weight6.80 kg
Inlet Connection1/8″ VCR
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 210 SA
Detection PrincipleFlame Photometric Detection (FPD)
Detection TargetTotal Sulfur in Gaseous or Liquid CO₂
Detection Limit<5 ppb for COS
Linear Dynamic Range>3 orders of magnitude
ComplianceISBT Methods 13 & 14
InstallationBenchtop or Rack-Mountable
Operating ModeContinuous or Discrete Flow
CalibrationAutomated Onboard Calibration
Temperature ControlFactory-Set Constant-Temperature Detection Zone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelA16
Instrument TypeLaboratory Gas Dilution Calibrator
Application ScopeUniversal Calibration for Trace Gas Analyzers
Dilution Ratio Range1:10 to 1:10,000 (typical)
Flow Control Accuracy±0.5% of setpoint
Pressure Regulation Range0–100 psig
Temperature Stability±0.1 °C (ambient-controlled environment)
Output Port ConfigurationDual independent calibrated outlets
ComplianceASTM D6420, ISO 6145-3, EPA Method 205
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGM Explosion-Proof Enclosure
Price RangeUSD 70,000 – 140,000
Instrument TypeExternal Protective Enclosure for Portable Gas Chromatographs
Application ScopeGeneral-Purpose Hazardous Area Deployment
Explosion Protection RatingExdp II BT1 to Exdp II CT6 (GB 3836 Compliant)
IP RatingIP65
Internal Pressure Range30–100 Pa
Power Supply220 VAC ±10%, 50 Hz
Construction MaterialsEP-grade stainless steel tubing (welded or VCR-fitted)
Viewing WindowShatter-resistant explosion-proof borosilicate glass
Certification BasisGB 3836.1–2010, GB 3836.5–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 1200
Detection PrinciplePlasma Emission Spectroscopy
Measurement Range0–2 ppm, 0–10 ppm, 0–20 ppm, 0–100 ppm, 0–200 ppm N₂ in Ar
Accuracy±0.02 ppm (0–2 ppm range), ±0.25 ppm (0–10/0–20 ppm ranges), ±2.50 ppm (0–100/0–200 ppm ranges)
Sensitivity±0.01 ppm (Model 1200-A/1202-A), ±0.10 ppm (1200-B/1202-B), ±1.00 ppm (1200-C/1202-C)
Sample Flow Rate2 scfh (0.88 slpm)
Inlet/Outlet Fittings1/4" VCR inlet, 1/4" Swagelok outlet
Operating Temperature16–35 °C (60–95 °F)
Max Inlet Pressure10 psig
Measurement Cell Pressure6 psig
Normal Inlet Pressure2–7 psig
Output Signals4–20 mA analog, dry contact alarms
Power100 W, 115/230 VAC, 50/60 Hz
Dimensions13.34 × 42.23 × 37.15 cm
Weight11.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 200C
Instrument TypeOnline Gas Chromatograph
Application ScopeUniversal Trace Gas Analysis
Detector OptionsPDHID, TCD, FID
Minimum Detection Limit (CH₄)<10 ppb
ConstructionCorrosion-Resistant Wetted Surface Coating
Control InterfaceHigh-Resolution Touchscreen LCD
Compliance ReadyASTM D7623, ISO 8573-5, USP <621>, FDA 21 CFR Part 11 (Software Audit Trail Enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelAr 722
Instrument TypeLaboratory Gas Chromatograph
ApplicationUniversal (Specialized for Ultra-High-Purity Argon Impurity Profiling)
Temperature Control Range0–450 °C
Ramp Rate0.1–40 °C/min
Cool-down Time~5 min (450 °C → 10 °C)
Carrier Gas Flow Range & Control0–30 mL/min
Carrier Gas Pressure Range & Control0–100 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setpoint Range0–100 kPa
Injector Total Flow Setpoint Range0–30 mL/min
Detection PrincipleGlow Discharge Photoemission Detection (GD-PED) with Argon as Carrier and Excitation Medium
Sensitivity (Typical LODs)H₂ < 15 ppb
Accuracy±1% of reading (calibrated against NIST-traceable standards)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginBeijing, China
ModelGM Explosion-Proof Analytical Shelter
Instrument TypePortable Gas Chromatograph System Enclosure
Application ScopeGeneral-purpose Industrial Process Gas Analysis
Explosion Protection RatingExd II BT1 to Exd II CT6 (customizable per user specification)
Ambient Temperature Control CapabilityIntegrated HVAC with temperature stabilization
Humidity & Dust ProtectionIP56-rated enclosure
Internal Overpressure Maintenance30–100 Pa (gauge)
Alarm FunctionAudible and visual alarm triggered by hazardous gas concentration exceedance
Power Supply220 VAC ±10%, 50 Hz
ComplianceDesigned to meet IEC 60079-1, GB 3836.1–2021, and ISO 8573-1 for compressed air quality in analytical service lines
Structural CertificationFabricated per ASME BPVC Section VIII Div. 1 (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGM 826 Series
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Detector CapacityUp to Four Detectors (including one TCD)
Column CompatibilityTwo 105 m × 0.53 mm Capillary Columns
Valve AutomationSupports up to 8 Automated Valves in a Single Method
Heating Zones6 Independent Zones (2 Inlets, 2 Detectors, 2 Auxiliary)
EPC ModulesUp to 6 Modules Controlling 16 EPC Channels
Sample Sequence CapacityUp to 550 Samples
Communication InterfacesEthernet, RS-232/RS-485, Dual Analog Outputs (1 mV / 1 V / 10 V), Remote Start/Stop, Barcode Reader Option
Pressure & Temperature CompensationAtmospheric Pressure and Ambient Temperature Compensation Integrated
Flow Path MaterialCorrosion-Resistant Optional Flow Path
Touchscreen InterfaceIntegrated Color TFT Display with Intuitive GUI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginUSA
Distributor TypeAuthorized Distributor
Import StatusImported
ModelI-Series
Instrument TypeOnline FTIR Spectrometer
Wavenumber Range4000–7500 cm⁻¹
Spectral Resolution0.5 cm⁻¹
Scan Speed8 s per spectrum
Signal-to-Noise Ratio<1% (RMS, 100 scans)
Wavenumber Accuracy±0.05 cm⁻¹ across 4000–7500 cm⁻¹
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0