BrandGOW-MAC
OriginUSA
ModelGOW-MAC 200DID
Detector TypeHelium Discharge Ionization Detector (DID)
Detection Limit<5 ppb
Linear Dynamic Range>10⁶
Column Oven Temperature Range+10 °C to 150 °C
Column FormatMicro-packed and 1/8″ packed columns
Flow ControlPrecision Mass Flow Controllers
Sample IntroductionPneumatically Actuated Gas Sampling Valve
Valve ConfigurationsBackflush, Column Selection, Heart-Cut, Series/Bypass
Construction MaterialsElectropolished Stainless Steel with VCR Fittings
Operating ModesManual (for method development) and Fully Automated (for continuous process analysis)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginBeijing, China
ModelGM-816
Detection Limit<5 ppb (CH₄, with DID detector)
Linear Dynamic Range>10⁶
Maximum Detector Capacity3 simultaneous detectors (e.g., DID-V, TCD, FPD, FID)
Column/Valve ConfigurationUp to 10 columns and 5 multi-dimensional switching valves
Flow ControlElectronic Pressure Control (EPC)
Power Supply220 V ±10%, 2250 W
Connection StandardVCR fittings for low-dead-volume gas pathways
Valve Oven ProtectionIntegrated valve box with thermal stabilization and contamination isolation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model1400
Measurement Range0–2 ppm / 0–20 ppm / 0–200 ppm H₂O in Ar
Accuracy±0.02 ppm (0–2 ppm), ±0.25 ppm (0–20 ppm), ±2.50 ppm (0–200 ppm)
Response Time (t₉₀)≤10 s
Sample Flow Rate2 scfh (0.88 slpm)
Inlet/Outlet Fittings1/4" VCR inlet, 1/4" Swagelok outlet
Operating Temperature16–35 °C
Max Inlet Pressure10 psig
Detector TypeMicrowave-Induced Plasma Emission Spectroscopy (MIP-ES)
Sensitivity±0.01 ppm (Model 1400-A/1402-A), ±0.10 ppm (Model 1400-B/1402-B)
Output4–20 mA analog + dry contact alarms
Power100 W, 115/230 VAC, 50/60 Hz
Dimensions13.34 × 42.23 × 37.15 cm
Weight11.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
ModelGM 1900
OriginBeijing, China
Detector OptionsDID-V, TCD, FID
Detection Limit (CH₄)<10 ppb
Operating ModeContinuous 24/7 online analysis
Temperature ControlMicroprocessor-regulated inlet, column oven, and detector zones
User InterfaceHigh-resolution resistive touch LCD panel
Corrosion ProtectionWet-coated wetted surfaces
Compliance FeaturesBuilt-in self-diagnostic, purge gas safeguard, auto-reboot on power recovery, alarm logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 2400
DetectorFlame Ionization Detector (FID)
Detection Limit0.05 ppm (as CH₄)
Operating Temperature15–35 °C
Response Time<5 s (to 90% of full response)
Drift<1% FS/24 h
Repeatability±1%
Flow ControlElectronic Pressure Control (EPC) for fuel, air, and sample
Zero IntervalUser-programmable auto-zero
Range Selection4 fixed ranges (0–10, 0–100, 0–1000, 0–10,000 ppm) or auto-ranging
Analog Output4–20 mA / 0–5 VDC (standard)
Digital InterfaceUSB + RS-232
Relay Outputs2 programmable (high/low alarm)
Sample Inlet1/8" tubing, min. pressure 2 psig, flow 5–70 cc/min
Fuel GasH₂, min. 2 psig
Combustion AirZero-air (<1 ppm THC), min. 25 psig, flow 10–350 cc/min
Enclosure3U rack-mount (19″) or benchtop
Dimensions48.3 × 13.3 × 52.1 cm
Weight15.9 kg
Power100 W, 115 V 60 Hz (2400-CM) or 230 V 50 Hz (2402-CM)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 210 BTEX
Detection Limit<5 ppb
Linear Range5 ppb to 5 ppm
Carrier Gas Flow Rate≈7 cc/min
Carrier Gas Pressure5–10 psig
Sample/Calibration Gas Pressure5 psig (max 20 psig)
Operating Temperature5–40 °C
Power Requirement400 W
Dimensions (W×H×D)42.9 × 31.1 × 58.4 cm
Weight23 kg (net), 28 kg (shipping)
Gas Fitting1/8" Swagelok
MountingEIA 19" rack (7U) or benchtop
Analog Outputssix 4–20 mA channels
Input TriggerTTL or dry contact
Display16×2 character LED backlight
User Interfacemembrane keypad (non-contact, numeric)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginBeijing, China
ModelGM 1900 Explosion-Proof Series
Explosion Protection MarkEx de ib mb px IIC T4 Gb
IP Rating≥IP65
Positive Pressure Range0–2069 Pa
Purge Time0–999 min (adjustable)
Alarm & Cut-off Pressure0–2069 Pa (adjustable)
Cabinet Dimensions90 cm × 75 cm × 50 cm
Gas PipingEP-grade stainless steel tubing with orbital welding or VCR fittings
Pre-shipment TestsPressure hold, leak detection, moisture analysis, oxygen analysis, particle count
ComplianceCertified by National Supervisory Inspection Center for Explosion-Protected Instrumentation (Cert. No.: GYB21.3140X)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model592
Detector TypeDischarge Ionization Detector (DID)
Detection Range1 ppb to <0.5% (v/v)
Carrier GasUltra-High-Purity Helium
Installation OptionsBenchtop or 19″ Rack-Mounted
Construction OptionsStainless Steel or Corrosion-Resistant Wet-Coated Surfaces
ComplianceDesigned for ASTM D7613, ISO 8573-5, and semiconductor-grade gas purity monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 5900 DID
Detector TypeDischarge Ionization Detector (DID)
Detection Range1 ppb to <0.5% (v/v)
Carrier GasHelium
ConstructionStainless Steel or Corrosion-Resistant System
ComplianceDesigned for Industrial Process Monitoring and Trace Impurity Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGOW-MAC 402
Price RangeUSD 1,500 – 7,500
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 210 AHC
Detection Limit<30 ppb
Carrier Gas Flow Rate≈30 cc/min
Carrier Gas Pressure60 psig
Sample Inlet Pressure5 psig (max 20 psig)
Calibration Gas Pressure5 psig (max 20 psig)
Operating Temperature5–40 °C
Power Requirement400 W
Dimensions (W×H×D)42.9×31.1×58.4 cm
Net Weight23 kg
Mounting19″ EIA rack (7U) or benchtop
Gas Fitting1/8″ Swagelok
Analog Outputssix 4–20 mA channels
Input TriggerTTL or dry contact
Display16×2 character LED-backlit LCD (99.0×24.0 mm active area)
User Interfacemembrane keypad (non-contact digital input)
Linear Range5–120 ppb (1×10³ dynamic range)
Sample Introductiondual-solenoid automated valve system with fixed-volume sampling loop