- All
- Favorite
- Popular
- Most rated
| Brand | Gerhardt (C. Gerhardt) |
|---|---|
| Origin | Germany |
| Model | Vapodest 450 |
| Configuration | Standalone Steam Distillation Unit with Optional External Titrator Integration |
| Compliance | Designed for ASTM D1193, ISO 8968-1, ISO 5983-1, AOAC 981.10, USP <467>, and EN ISO 1871 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model(s) | EV1 (1-position), EV14 (4-position), EV16 (6-position) |
| Max Temperature | 425 °C |
| Block Dimensions (EV1) | 150 × 225 × 110 mm |
| Weight (EV1) | 2 kg |
| Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Power (EV1) | 450 W |
| Heating Element | Precision-machined aluminum alloy block with embedded resistance heaters |
| Control Type | Analog dial with mechanical thermostat (EV1) / Digital PID controller with LED display (EV14/EV16, optional upgrade) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | EV6 AII14 / EV6 AII16 |
| Max. Heating Temperature | 425 °C |
| Heating Block Positions | 4 / 6 |
| Flask Capacity | 250–500 mL |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power Consumption | 1800 W / 2700 W |
| Dimensions (W×D×H) | 600×225×650 mm / 900×225×650 mm |
| Weight | 10 kg / 14 kg |
| Compliance | ASTM D2230, ISO 6496, AOAC 920.39, USP <467> |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | RF16/4 / RF16/6 |
| Max Temperature | 425 °C |
| Heating Positions | 4 / 6 |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power | 1800 W / 2700 W |
| Dimensions (W×D×H) | 600×225×340 mm / 900×225×340 mm |
| Weight | 12 kg / ~18 kg |
| Order Codes | 10-0017 / 10-0018 |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 450 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg N |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤±1% RSD |
| Sample Weight Capacity | ≤5 g (solid) / ≤20 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 200 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg N |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤±1% RSD |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 400 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg N |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤ ±1% RSD |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | KT / KT-L |
| Sample Capacity | 8/20/40 positions |
| Digestion Tube Sizes | 100 mL, 250 mL, 400 mL |
| Temperature Control Accuracy | ±0.5% of setpoint |
| Programmable Methods | 99 methods, up to 40 temperature ramps per method |
| Predefined Methods | 30 standard protocols |
| Heating Rate | Adjustable |
| Safety Features | Overheat protection, acid drip tray, audible/visual alarms, automatic fume extraction activation, user-configurable safety cutoff temperature |
| Compliance | ISO/IEC 17025, GLP, FDA 21 CFR Part 11 (audit trail & user access control), DIN EN ISO 5983, AOAC 984.13, EPA 350.1, ASTM D5142, EU Regulation (EC) No 152/2009, APHA 4500-Norg, Ph. Eur. 2.5.33 (Method 7, Step A) |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | TUR/K |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power Consumption | 205 W |
| Weight | 19 kg |
| Dimensions (W × D × H) | 330 × 450 × 420 mm |
| Exhaust Gas Removal Efficiency | >90% |
| Maintenance Requirement | Minimal |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | KI 12/24 / KI 9/16 |
| Max. Heating Temperature | 650 °C / 600 °C |
| Heating Block Capacity | 4 × 500–750 mL flasks / 6 × 50–250 mL flasks |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power | 2320 W / 1800 W |
| Dimensions (W×D×H) | 650 × 380 × 950 mm |
| Weight | 35 kg / 25 kg |
| Compliance | Designed for ASTM D1142, ISO 5983-1, AOAC 984.13, and USP <467> residual solvent workflows |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 300 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤±1% |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | Gerhardt (C. Gerhardt) |
|---|---|
| Origin | Germany |
| Model | Dumatherm DT N Pro |
| Configuration | Pneumatic autosampler (64-position standard |
| Detection Principle | High-temperature combustion followed by thermal conductivity detection (TCD) and/or chemiluminescence detection (CLD) of nitrogen oxides after catalytic reduction |
| Sample Forms | Solid, liquid, semi-solid (paste) |
| Typical Analysis Time | ≤180 s per sample |
| Nitrogen Range | Up to 50 mg N per analysis |
| RSD | <0.5% (absolute, for 200 mg EDTA reference) |
| Carrier Gas Options | Helium (optimal sensitivity) or Argon (cost-optimized) |
| Oxygen Delivery | Software-controlled precise dosing |
| Compliance | AOAC, DIN EN ISO, USP, and national food/feed/environmental standards |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 300 |
| Water Consumption | ~3 L/min |
| Distillation Time | ~3 min 30 s (standard Kjeldahl method) |
| Power | 2200 W |
| Frequency | 50/60 Hz |
| Weight | 34 kg |
| Dimensions | 527 × 390 × 697 mm |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Supply Voltage | 230 V AC |
| Nitrogen Recovery Rate | >99.5% |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Product Type | Imported Manual Single-Channel Volumetric Pipettes |
| Models | 4201 (0.25–2.50 mL), 4202 (0.50–5.00 mL), 4203 (1.00–10.00 mL), 4204 (2.50–25.00 mL), 4205 (5.00–50.00 mL) |
| Max Capacity | 2.5 mL / 5 mL / 10 mL / 25 mL / 50 mL |
| Accuracy Tolerance | ±0.025 mL |
| Operation Mode | Manual |
| Channel Count | Single |
| Compliance | ISO 8655-2:2022 (Volumetric pipettes – Part 2: Piston-operated volumetric apparatus) |
| Brand | LabS |
|---|---|
| Origin | Guangdong, China |
| Model | FL-0904A / FL-1105A |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | 5–40 °C |
| Temperature Stability | ±0.5 °C |
| Refrigeration Capacity | 1600–2700 W |
| Circulating Pump Pressure | 1.0 bar |
| Circulating Pump Flow Rate | 42 L/min |
| Reservoir Volume | 8.5 L |
| Heat Exchanger Material | Stainless Steel |
| Compressor | Premium Industrial-Grade |
| Refrigerant Option | R134a or Eco-Friendly Alternative (Optional) |
| Noise Level | Low-Noise Operation |
| Control System | Microprocessor-Based Digital Controller |
| Dual-Circuit Capability | Internal + External Loop Support |
| Remote Control Interface | Optional 0–10 V or Dry Contact Input |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.25–50 mL |
| Graduation Interval | 0.25 mL |
| Accuracy | ±0.5% |
| Precision | 99.5% |
| Available Models | 2.50 mL, 5.00 mL, 10.00 mL, 25.00 mL, 50.00 mL |
| Compliance | ISO 8655-3, DIN EN ISO 8655-3, GLP-ready design |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | N-Realyzer |
| Principle | Dumas Combustion Method |
| Automation Level | Fully Automated |
| Nitrogen Range | 0.003–50 mg N |
| Repeatability | RSD < 0.5% |
| Max Sample Weight | 1 g |
| Recovery Rate | ≥99.5% |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 600 × 550 × 722 mm |
Show next