BrandHanna Instruments
OriginUSA
Manufacturer TypeOEM Manufacturer
Origin CategoryImported
ModelHI98150
Instrument TypePortable
Parameter TypesDual (pH + ORP)
Measurement Range-4.0 to 20.0 pH
Resolution0.1 pH
Accuracy±0.1 pH
Calibration StandardsNIST-traceable and USA-standard buffer solutions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeBenchtop
Parameters MeasuredpH, ORP, Temperature
pH Range-2.00 to 16.00
ORP Range±399.9 mV and ±2000 mV
Temperature Range-9.9 to 120.0 °C
pH Resolution0.01
ORP Resolution0.1 mV (±399.9 mV), 1 mV (±2000 mV)
Temperature Resolution0.1 °C
pH Accuracy±0.01
ORP Accuracy±0.2 mV (±399.9 mV), ±1 mV (±2000 mV)
Temperature Accuracy±0.5 °C (0.0–100.0 °C), ±1.0 °C (remaining range)
Calibration StandardsNIST/USA traceable buffers
Calibration PointsAuto-recognized 1-point or 2-point
Temperature CompensationAutomatic or manual (-20.0 to 120.0 °C)
Input Impedance10¹² Ω
Electrode InterfaceBNC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeBenchtop pH Meter
ModelHI2212
Measurement ParameterspH and Temperature (°C)
pH Range-2.00 to 16.00 pH
Temperature Range-20.0 to 120.0 °C
pH Resolution0.01 pH
Temperature Resolution0.1 °C
pH Accuracy±0.01 pH @ 20°C
Temperature Accuracy±0.4 °C (excluding probe error)
Calibration StandardsNIST-traceable or USA-standard buffers
Calibration MethodAutomatic 3-point with 5 built-in standard points (pH 4.01, 6.86, 7.01, 9.18, 10.01)
Temperature CompensationAutomatic or manual (-20.0 to 120.0 °C)
Input Impedance10¹² Ω
Electrode InterfaceBNC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelHI83141
Instrument TypePortable
Parameter ChannelsDual (pH + ORP)
pH Range0.00 to 14.00
ORP Range±1999 mV
Temperature Range0.0 to 100.0 °C
pH Resolution0.01
ORP Resolution1 mV
Temperature Resolution0.1 °C
pH Accuracy±0.01
ORP Accuracy±1 mV
Temperature Accuracy±0.4 °C (excluding probe error)
Calibration StandardsNIST-traceable and USA-standard buffer solutions
Calibration MethodManual two-point pH calibration (with optional single-point ORP verification)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
TypeBenchtop Conductivity Meter
ModelHI2315
Measurement ParametersConductivity, TDS, Resistivity, Salinity, Temperature
Conductivity Range0.0–199.9 µS/cm
TDS Range0–0.1 g/L
Resistivity Range0–0.1 MΩ·cm
Salinity Range0–0.1 ppt
Temperature Range0.0–50.0 °C
Accuracy±1% of full scale
Resolution0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeImported Benchtop Instrument
ModelHI2030
Conductivity Range0.000 to 500 mS/cm
TDS Range0.000 to 400.0 g/L (ppt)
Salinity Ranges0.00 to 42.00 PSU, 0.00 to 80.00 g/L (ppt), 0.0 to 400.0 % NaCl
Temperature Range−20.0 to 120.0 °C (−4.0 to 248.0 °F)
Accuracy±1% of reading (±0.5 µS/cm or 1 digit, whichever greater)
Resolution0.01 µS/cm, 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm, 0.01 mg/L (ppm), 0.1 mg/L (ppm), 1 mg/L (ppm), 0.01 g/L, 0.1 g/L (0.8 TDS factor), 0.1% NaCl, 0.01 PSU
CalibrationManual single-point
Temperature CompensationAutomatic (ATC) and No-Temperature Compensation (noTC) modes
TDS Conversion FactorAdjustable 0.40–0.80
Data Storage1000 total records (200 on-demand + 600 interval-logged)
InterfaceDual USB (Mini-USB for data transfer & charging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments, Inc.
Product TypePortable pH Meter
Parameter TypeSingle-Parameter (pH + Temperature)
pH Accuracy±0.02 pH
pH Range−2.00 to 16.00 pH
Temperature Range−5.0 to 105.0 °C / 23.0 to 221.0 °F
pH Resolution0.01 pH
Temperature Resolution0.1 °C / 0.1 °F
Temperature Accuracy±0.5 °C (−5 to 60 °C), ±1.0 °C (60 to 105.0 °C)
Calibration StandardsNIST-traceable or USA-standard pH buffers
Calibration ModesAutomatic 1- or 2-point calibration with built-in buffer recognition (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18)
ElectrodeHI1296D stainless steel body pH electrode with integrated Pt1000 temperature sensor
ATC Range−5.0 to 105.5 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeBenchtop
Parameters MeasuredpH and Temperature
pH Range-2.00 to 16.00
Temperature Range-20.0 to 120.0 °C
pH Resolution0.01
Temperature Resolution0.1 °C
pH Accuracy±0.01 at 20 °C
Temperature Accuracy±0.4 °C (0.0 to 100.0 °C), ±1.0 °C (remaining range)
CalibrationAuto-recognizing 1- or 2-point calibration with built-in NIST-traceable standards (pH 4.01, 6.86, 7.01, 9.18, 10.01)
Temperature CompensationAutomatic or manual (-20.0 to 120.0 °C)
Input Impedance10¹² Ω
Electrode InterfaceBNC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeImported
ModelHI9125
Instrument TypePortable
Parameter TypesDual (pH & ORP)
Measurement Accuracy±0.01 pH
pH Range-2.00 to 16.00
ORP Range±699.9 mV
Temperature Range-20.0 to 120.0°C / -4.0 to 248.0°F
Resolution0.01 pH
Accuracy (excluding probe error)±0.01 pH
Calibration StandardsNIST-traceable and USA-certified buffers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelHI8424
Instrument TypePortable
Parameter TypesMulti-parameter
pH Range-2.00 to 16.00 pH
ORP Range±699.9 mV and ±1999 mV
Temperature Range-20.0 to 120.0 °C
pH Resolution0.01
pH Accuracy±0.01 pH
ORP Resolution0.1 mV / 1 mV
ORP Accuracy±0.2 mV (±699.9 mV), ±1 mV (±1999 mV)
Temperature Resolution0.1 °C
Temperature Accuracy±0.4 °C
Calibration PointsAuto-recognized pH 4.01, 7.01, 10.01
Calibration MethodAutomatic 1- or 2-point
Temperature CompensationAutomatic or Manual (-20.0 to 120.0 °C)
Electrode InterfaceBNC
Input Impedance10¹² Ω
Power Supply1 × 9 V rechargeable battery (inductive charging compatible)
IP RatingIP67
Operating Environment0 to 50 °C, RH ≤ 100%
Dimensions164 × 76 × 45 mm
Weight180 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeDirect Manufacturer
Origin CategoryImported
ModelHI98107
Instrument TypePen-Style
Parameter TypeSingle-Parameter (pH)
Measurement Range0.0 to 14.0 pH
Resolution0.1 pH
Accuracy±0.1 pH
CalibrationManual Two-Point Calibration (NIST/USA Traceable Buffers)
ElectrodeIntegrated HI73106 Combination pH Electrode
Power Supply4 × 1.5 V AAA Batteries
Operating Environment0 to 50 °C (32 to 122 °F)
Dimensions & Weight175 × 41 × 23 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna
OriginItaly
ManufacturerHanna Instruments
Product TypeImported Portable Conductivity Meter
ModelHI8733
Measurement ParametersSingle-parameter (Conductivity/EC, TDS, Resistivity, Salinity, Temperature)
Conductivity Range0.0 to 199.9 µS/cm
TDS Range0 to 0.1 g/L
Resistivity Range0 to 0.1 MΩ·cm
Salinity Range0 to 0.1 ppt
Temperature CompensationAutomatic, 0 to 50 °C with adjustable β coefficient (0.0 to 2.5 %/°C)
Accuracy±1% of full scale
Resolution0.1 µS/cm
Power Supply1 × 9 V battery
Operating Environment0 to 50 °C, RH ≤ 100%
Dimensions145 × 80 × 36 mm
Weight230 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported
ModelHI3222
Instrument TypeBenchtop
Parameter TypespH, ORP, ISE, Temperature
pH Accuracy±0.01 pH / ±0.002 pH
ORP Accuracy±0.2 mV
ISE Accuracy±0.5% of reading (monovalent), ±1% of reading (divalent)
Temperature Accuracy±0.4°C
pH Range–2.0 to 20.000 pH (selectable resolution: 0.1 / 0.01 / 0.001 pH)
ORP Range±2000 mV (resolution: 0.1 mV / 1 mV)
ISE Range1.00 × 10⁻⁷ to 1.00 × 10¹⁰ (units selectable: ppm, mol/L, mg/L, %, etc.)
Temperature Range–20.0 to 120.0°C (resolution: 0.1°C)
CalibrationUp to 5-point pH auto-calibration with 7 built-in NIST/USA standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 user-defined points
ISE CalibrationUp to 5-point with 6 stored standards (0.1–10,000 concentration units)
Temperature CompensationAutomatic or manual (–20.0 to 120.0°C)
Input Impedance≥10¹² Ω
Data StorageManual — 400 records
Auto — 1000 records (configurable intervals5 s to 180 min)
ConnectivityUSB interface (requires optional HI92000 software and cable)
DisplayBacklit LCD with real-time status icons and electrode performance feedback
Power Supply12 VDC adapter
Operating Environment0 to 50°C, ≤55% RH
Dimensions & Weight235 × 207 × 110 mm, 1.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypePortable
Measurement ParameterspH & ORP (dual-parameter)
pH Range-2.00 to 16.00
ORP Range±699.9 mV and ±1999 mV
Temperature Range-20.0 to 120.0°C (-4.0 to 248.0°F)
pH Resolution0.01
ORP Resolution0.1 mV (±699.9 mV), 1 mV (±1999 mV)
Temperature Resolution0.1°C / 0.1°F
Accuracy (pH)±0.01 pH @ 20°C
Accuracy (ORP)±0.2 mV (±699.9 mV), ±1 mV (±1999 mV)
Accuracy (Temperature)±0.4°C / ±0.8°F (excluding probe error)
CalibrationAuto-recognized 2-point with 7 built-in NIST/USA traceable buffer points (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
Temperature CompensationAutomatic or manual (-20.0 to 120.0°C)
Input Impedance10¹² Ω
Electrode InterfaceBNC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments, Inc.
Product TypePortable pH Meter
Parameter TypeSingle-Parameter (pH + Temperature)
Measurement Range-2.00 to 16.00 pH / -5.0 to 105.0°C / 23.0 to 221.0°F
Resolution0.01 pH / 0.1°C / 0.1°F
Accuracy±0.02 pH / ±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C) / ±1.0°F (23 to 140°F), ±2.0°F (140 to 221.0°F)
Calibration StandardsNIST-traceable and USA-certified buffers
Electrode InterfaceDIN-7 connector
Included ElectrodeHI62911D titanium-bodied flat-surface pH electrode with integrated temperature sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeBenchtop
Parameters MeasuredpH, ORP, Temperature
Measurement Accuracy±0.01 pH
Measurement Range-2.00 to 16.00 pH
Resolution0.01 pH
Calibration StandardsNIST-traceable and USA-standard buffer solutions
Calibration PointsAuto-recognized 5-point calibration with 7 built-in standard buffers (pH 1.68, 3.00, 6.86, 7.01, 9.18, 10.01, 12.45)
Temperature CompensationAutomatic or manual, -20.0 to 120.0 °C
Electrode Input Impedance10¹² Ω
Data Storage100 measurement records
InterfaceUSB port (compatible with HI92000 PC software)
Electrode CompatibilityHI1048P refillable glass combination pH electrode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeManufacturer
Origin CategoryImported
ModelHI99171
Instrument TypePortable
Parameter TypesDual (pH & Temperature)
pH Accuracy±0.02 pH
pH Range-2.00 to 16.00 pH
Temperature Range-5.0 to 105.0°C / 23.0 to 221.0°F
pH Resolution0.01 pH
Temperature Resolution0.1°C / 0.1°F
Temperature Accuracy±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C)
Calibration StandardNIST/USA Traceable Buffers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelHI4222
Instrument TypeMultifunctional Benchtop Meter
Parameter TypespH, ORP, ISE, Temperature
Measurement Accuracy±0.002 pH (±1 LSD), ±0.2 mV, ±0.5% (monovalent ions), ±0.2°C
Measurement Ranges−2.000 to 20.000 pH
Resolution0.001 pH
Calibration StandardsNIST-traceable and USA-certified buffers
Calibration OptionsUp to 5-point automatic pH calibration (8 built-in + 5 user-defined points)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeImported
ModelHI98308
Measurement ParameterConductivity (Single-Parameter)
Form FactorPen-Style Portable
Conductivity Range0.0 to 99.9 µS/cm
TDS Range0.000 to 0.001 g/L (ppm)
Resistivity Range0.0 to 10.0 MΩ·cm
Salinity Range0.00 to 0.01 ppt
Temperature Range0.0 to 50.0 °C
Accuracy±2% of Full Scale
Resolution0.1 µS/cm
CalibrationManual Single-Point (HI7033L recommended)
Temperature CompensationAutomatic (0 to 50 °C)
Power4 × 1.5 V AAA batteries
Operating Environment0 to 50 °C, ≤95% RH
Dimensions175 × 41 × 23 mm
Weight95 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments, Inc.
Import StatusImported
ModelHI99161
Instrument TypePortable
Parameter CountDual (pH and Temperature)
pH Accuracy±0.02 pH
Temperature Accuracy±1.0 °C / ±0.2 °F
pH Range-2.00 to 16.00 pH
Temperature Range-5.0 to 105.0 °C / 23.0 to 221.0 °F
pH Resolution0.01 pH
Temperature Resolution0.1 °C / 0.1 °F
Calibration StandardsNIST/USA traceable buffers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeManufacturer
Instrument TypePortable pH Meter
Parameter TypeSingle-Parameter (pH & Temperature)
pH Accuracy±0.02 pH
pH Range-2.00 to 16.00 pH
Temperature Range-5.0 to 105.0°C / 23.0 to 221.0°F
pH Resolution0.01 pH
Temperature Resolution0.1°C / 0.1°F
Temperature Accuracy±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C)
Calibration StandardsNIST/USA traceable buffers
Calibration OptionsAuto 1-point or 2-point (memory for two calibration sets: pH 4.01/7.01/10.01 or 4.01/6.86/9.18)
ATC Range-5.0 to 105.0°C
Electrode InterfaceD-type connector
Compatible ElectrodeHI1291D combination pH electrode with integrated temperature sensor
Stirring FunctionBuilt-in magnetic stirrer (HI208 only)
Power Supply1 × 9 V battery or 12 VDC adapter
Operating Environment-5 to 50°C, RH ≤ 100%
Dimensions190 × 105 × 50 mm
Weight420 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelHI99121N
Instrument TypePortable
Parameter TypeSingle-Parameter (pH + Temperature)
Measurement Accuracy±0.02 pH
pH Range-2.00 to 16.00 pH
Temperature Range-5.0 to 105.0°C / 23.0 to 221.0°F
Resolution0.01 pH / 0.1°C / 0.1°F
Temperature Accuracy±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C)
Calibration StandardsNIST-traceable or USA-standard buffer solutions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypePortable
Measurement ParameterspH, ORP, Temperature
pH Range-2.00 to 16.00 pH
ORP Range±1999 mV
Temperature Range-5.0 to 105.0°C / 23.0 to 221.0°F
pH Resolution0.01 pH
ORP Resolution1 mV
Temperature Resolution0.1°C / 0.1°F
pH Accuracy±0.02 pH
ORP Accuracy±2 mV
Temperature Accuracy±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C)
CalibrationAuto 1- or 2-point with NIST/USA traceable buffers (pH 4.01/7.01/10.01 or 4.01/6.86/9.18)
Temperature CompensationAutomatic (ATC), -5.0 to 105.0°C
ElectrodeHI1297D combination probe with integrated temperature sensor and DIN connector
Power3 × 1.5 V AA batteries
IP RatingIP67 (dust-tight and submersible up to 1 m for 30 min)
Operating Environment0 to 50°C, ≤100% RH
Dimensions152 × 58 × 30 mm
Weight205 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported
ModelHI3221
Instrument TypeBenchtop
Parameter TypesMulti-parameter
pH Accuracy±0.01 pH / ±0.002 pH
ORP Accuracy±0.2 mV
ISE Accuracy±0.5% of reading (monovalent), ±1% of reading (divalent)
Temperature Accuracy±0.4°C
pH Range–2.0 to 20.000 pH
ORP Range±2000 mV
ISE Range1.00 × 10⁻³ to 1.00 × 10⁵ ppm
Temperature Range–20.0 to 120.0°C
pH Resolution0.1 / 0.01 / 0.001 pH
ORP Resolution0.1 / 1 mV
ISE Resolution0.01 / 0.1 / 1 / 10 ppm
Temperature Resolution0.1°C
CalibrationUp to 5-point pH auto-calibration with 7 built-in NIST/USA standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 user-defined points
ISE Calibration2-point calibration with 6 stored standards (0.1, 1, 10, 100, 1000, 10000 ppm)
Temperature CompensationAutomatic or manual (–20.0 to 120.0°C)
Electrode InterfaceBNC + dedicated temperature probe (HI7662)
Input Impedance10¹² Ω
Data StorageManual storage for 300 readings
ConnectivityUSB interface (PC connection requires optional HI92000 software and cable)
Power Supply12 VDC adapter
Operating Environment0 to 50°C, max 55% RH
Dimensions & Weight235 × 207 × 110 mm, 1.8 kg