- All
- Favorite
- Popular
- Most rated
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | HI98150 |
| Instrument Type | Portable |
| Parameter Types | Dual (pH + ORP) |
| Measurement Range | -4.0 to 20.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Calibration Standards | NIST-traceable and USA-standard buffer solutions |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Benchtop |
| Parameters Measured | pH, ORP, Temperature |
| pH Range | -2.00 to 16.00 |
| ORP Range | ±399.9 mV and ±2000 mV |
| Temperature Range | -9.9 to 120.0 °C |
| pH Resolution | 0.01 |
| ORP Resolution | 0.1 mV (±399.9 mV), 1 mV (±2000 mV) |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 |
| ORP Accuracy | ±0.2 mV (±399.9 mV), ±1 mV (±2000 mV) |
| Temperature Accuracy | ±0.5 °C (0.0–100.0 °C), ±1.0 °C (remaining range) |
| Calibration Standards | NIST/USA traceable buffers |
| Calibration Points | Auto-recognized 1-point or 2-point |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0 °C) |
| Input Impedance | 10¹² Ω |
| Electrode Interface | BNC |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Benchtop pH Meter |
| Model | HI2212 |
| Measurement Parameters | pH and Temperature (°C) |
| pH Range | -2.00 to 16.00 pH |
| Temperature Range | -20.0 to 120.0 °C |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH @ 20°C |
| Temperature Accuracy | ±0.4 °C (excluding probe error) |
| Calibration Standards | NIST-traceable or USA-standard buffers |
| Calibration Method | Automatic 3-point with 5 built-in standard points (pH 4.01, 6.86, 7.01, 9.18, 10.01) |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0 °C) |
| Input Impedance | 10¹² Ω |
| Electrode Interface | BNC |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HI83141 |
| Instrument Type | Portable |
| Parameter Channels | Dual (pH + ORP) |
| pH Range | 0.00 to 14.00 |
| ORP Range | ±1999 mV |
| Temperature Range | 0.0 to 100.0 °C |
| pH Resolution | 0.01 |
| ORP Resolution | 1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 |
| ORP Accuracy | ±1 mV |
| Temperature Accuracy | ±0.4 °C (excluding probe error) |
| Calibration Standards | NIST-traceable and USA-standard buffer solutions |
| Calibration Method | Manual two-point pH calibration (with optional single-point ORP verification) |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments, Inc. |
| Product Type | Portable pH Meter |
| Parameter Type | Single-Parameter (pH + Temperature) |
| pH Accuracy | ±0.02 pH |
| pH Range | −2.00 to 16.00 pH |
| Temperature Range | −5.0 to 105.0 °C / 23.0 to 221.0 °F |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.5 °C (−5 to 60 °C), ±1.0 °C (60 to 105.0 °C) |
| Calibration Standards | NIST-traceable or USA-standard pH buffers |
| Calibration Modes | Automatic 1- or 2-point calibration with built-in buffer recognition (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18) |
| Electrode | HI1296D stainless steel body pH electrode with integrated Pt1000 temperature sensor |
| ATC Range | −5.0 to 105.5 °C |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Benchtop |
| Parameters Measured | pH and Temperature |
| pH Range | -2.00 to 16.00 |
| Temperature Range | -20.0 to 120.0 °C |
| pH Resolution | 0.01 |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 at 20 °C |
| Temperature Accuracy | ±0.4 °C (0.0 to 100.0 °C), ±1.0 °C (remaining range) |
| Calibration | Auto-recognizing 1- or 2-point calibration with built-in NIST-traceable standards (pH 4.01, 6.86, 7.01, 9.18, 10.01) |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0 °C) |
| Input Impedance | 10¹² Ω |
| Electrode Interface | BNC |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Imported |
| Model | HI9125 |
| Instrument Type | Portable |
| Parameter Types | Dual (pH & ORP) |
| Measurement Accuracy | ±0.01 pH |
| pH Range | -2.00 to 16.00 |
| ORP Range | ±699.9 mV |
| Temperature Range | -20.0 to 120.0°C / -4.0 to 248.0°F |
| Resolution | 0.01 pH |
| Accuracy (excluding probe error) | ±0.01 pH |
| Calibration Standards | NIST-traceable and USA-certified buffers |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI8424 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Range | -2.00 to 16.00 pH |
| ORP Range | ±699.9 mV and ±1999 mV |
| Temperature Range | -20.0 to 120.0 °C |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 pH |
| ORP Resolution | 0.1 mV / 1 mV |
| ORP Accuracy | ±0.2 mV (±699.9 mV), ±1 mV (±1999 mV) |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Calibration Points | Auto-recognized pH 4.01, 7.01, 10.01 |
| Calibration Method | Automatic 1- or 2-point |
| Temperature Compensation | Automatic or Manual (-20.0 to 120.0 °C) |
| Electrode Interface | BNC |
| Input Impedance | 10¹² Ω |
| Power Supply | 1 × 9 V rechargeable battery (inductive charging compatible) |
| IP Rating | IP67 |
| Operating Environment | 0 to 50 °C, RH ≤ 100% |
| Dimensions | 164 × 76 × 45 mm |
| Weight | 180 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | HI98107 |
| Instrument Type | Pen-Style |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0.0 to 14.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Calibration | Manual Two-Point Calibration (NIST/USA Traceable Buffers) |
| Electrode | Integrated HI73106 Combination pH Electrode |
| Power Supply | 4 × 1.5 V AAA Batteries |
| Operating Environment | 0 to 50 °C (32 to 122 °F) |
| Dimensions & Weight | 175 × 41 × 23 mm |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | HI3222 |
| Instrument Type | Benchtop |
| Parameter Types | pH, ORP, ISE, Temperature |
| pH Accuracy | ±0.01 pH / ±0.002 pH |
| ORP Accuracy | ±0.2 mV |
| ISE Accuracy | ±0.5% of reading (monovalent), ±1% of reading (divalent) |
| Temperature Accuracy | ±0.4°C |
| pH Range | –2.0 to 20.000 pH (selectable resolution: 0.1 / 0.01 / 0.001 pH) |
| ORP Range | ±2000 mV (resolution: 0.1 mV / 1 mV) |
| ISE Range | 1.00 × 10⁻⁷ to 1.00 × 10¹⁰ (units selectable: ppm, mol/L, mg/L, %, etc.) |
| Temperature Range | –20.0 to 120.0°C (resolution: 0.1°C) |
| Calibration | Up to 5-point pH auto-calibration with 7 built-in NIST/USA standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 user-defined points |
| ISE Calibration | Up to 5-point with 6 stored standards (0.1–10,000 concentration units) |
| Temperature Compensation | Automatic or manual (–20.0 to 120.0°C) |
| Input Impedance | ≥10¹² Ω |
| Data Storage | Manual — 400 records |
| Auto — 1000 records (configurable intervals | 5 s to 180 min) |
| Connectivity | USB interface (requires optional HI92000 software and cable) |
| Display | Backlit LCD with real-time status icons and electrode performance feedback |
| Power Supply | 12 VDC adapter |
| Operating Environment | 0 to 50°C, ≤55% RH |
| Dimensions & Weight | 235 × 207 × 110 mm, 1.8 kg |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Portable |
| Measurement Parameters | pH & ORP (dual-parameter) |
| pH Range | -2.00 to 16.00 |
| ORP Range | ±699.9 mV and ±1999 mV |
| Temperature Range | -20.0 to 120.0°C (-4.0 to 248.0°F) |
| pH Resolution | 0.01 |
| ORP Resolution | 0.1 mV (±699.9 mV), 1 mV (±1999 mV) |
| Temperature Resolution | 0.1°C / 0.1°F |
| Accuracy (pH) | ±0.01 pH @ 20°C |
| Accuracy (ORP) | ±0.2 mV (±699.9 mV), ±1 mV (±1999 mV) |
| Accuracy (Temperature) | ±0.4°C / ±0.8°F (excluding probe error) |
| Calibration | Auto-recognized 2-point with 7 built-in NIST/USA traceable buffer points (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0°C) |
| Input Impedance | 10¹² Ω |
| Electrode Interface | BNC |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments, Inc. |
| Product Type | Portable pH Meter |
| Parameter Type | Single-Parameter (pH + Temperature) |
| Measurement Range | -2.00 to 16.00 pH / -5.0 to 105.0°C / 23.0 to 221.0°F |
| Resolution | 0.01 pH / 0.1°C / 0.1°F |
| Accuracy | ±0.02 pH / ±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C) / ±1.0°F (23 to 140°F), ±2.0°F (140 to 221.0°F) |
| Calibration Standards | NIST-traceable and USA-certified buffers |
| Electrode Interface | DIN-7 connector |
| Included Electrode | HI62911D titanium-bodied flat-surface pH electrode with integrated temperature sensor |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Benchtop |
| Parameters Measured | pH, ORP, Temperature |
| Measurement Accuracy | ±0.01 pH |
| Measurement Range | -2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Calibration Standards | NIST-traceable and USA-standard buffer solutions |
| Calibration Points | Auto-recognized 5-point calibration with 7 built-in standard buffers (pH 1.68, 3.00, 6.86, 7.01, 9.18, 10.01, 12.45) |
| Temperature Compensation | Automatic or manual, -20.0 to 120.0 °C |
| Electrode Input Impedance | 10¹² Ω |
| Data Storage | 100 measurement records |
| Interface | USB port (compatible with HI92000 PC software) |
| Electrode Compatibility | HI1048P refillable glass combination pH electrode |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | HI99171 |
| Instrument Type | Portable |
| Parameter Types | Dual (pH & Temperature) |
| pH Accuracy | ±0.02 pH |
| pH Range | -2.00 to 16.00 pH |
| Temperature Range | -5.0 to 105.0°C / 23.0 to 221.0°F |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1°C / 0.1°F |
| Temperature Accuracy | ±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C) |
| Calibration Standard | NIST/USA Traceable Buffers |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI4222 |
| Instrument Type | Multifunctional Benchtop Meter |
| Parameter Types | pH, ORP, ISE, Temperature |
| Measurement Accuracy | ±0.002 pH (±1 LSD), ±0.2 mV, ±0.5% (monovalent ions), ±0.2°C |
| Measurement Ranges | −2.000 to 20.000 pH |
| Resolution | 0.001 pH |
| Calibration Standards | NIST-traceable and USA-certified buffers |
| Calibration Options | Up to 5-point automatic pH calibration (8 built-in + 5 user-defined points) |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments, Inc. |
| Import Status | Imported |
| Model | HI99161 |
| Instrument Type | Portable |
| Parameter Count | Dual (pH and Temperature) |
| pH Accuracy | ±0.02 pH |
| Temperature Accuracy | ±1.0 °C / ±0.2 °F |
| pH Range | -2.00 to 16.00 pH |
| Temperature Range | -5.0 to 105.0 °C / 23.0 to 221.0 °F |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Calibration Standards | NIST/USA traceable buffers |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Instrument Type | Portable pH Meter |
| Parameter Type | Single-Parameter (pH & Temperature) |
| pH Accuracy | ±0.02 pH |
| pH Range | -2.00 to 16.00 pH |
| Temperature Range | -5.0 to 105.0°C / 23.0 to 221.0°F |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1°C / 0.1°F |
| Temperature Accuracy | ±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C) |
| Calibration Standards | NIST/USA traceable buffers |
| Calibration Options | Auto 1-point or 2-point (memory for two calibration sets: pH 4.01/7.01/10.01 or 4.01/6.86/9.18) |
| ATC Range | -5.0 to 105.0°C |
| Electrode Interface | D-type connector |
| Compatible Electrode | HI1291D combination pH electrode with integrated temperature sensor |
| Stirring Function | Built-in magnetic stirrer (HI208 only) |
| Power Supply | 1 × 9 V battery or 12 VDC adapter |
| Operating Environment | -5 to 50°C, RH ≤ 100% |
| Dimensions | 190 × 105 × 50 mm |
| Weight | 420 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI99121N |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH + Temperature) |
| Measurement Accuracy | ±0.02 pH |
| pH Range | -2.00 to 16.00 pH |
| Temperature Range | -5.0 to 105.0°C / 23.0 to 221.0°F |
| Resolution | 0.01 pH / 0.1°C / 0.1°F |
| Temperature Accuracy | ±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C) |
| Calibration Standards | NIST-traceable or USA-standard buffer solutions |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Portable |
| Measurement Parameters | pH, ORP, Temperature |
| pH Range | -2.00 to 16.00 pH |
| ORP Range | ±1999 mV |
| Temperature Range | -5.0 to 105.0°C / 23.0 to 221.0°F |
| pH Resolution | 0.01 pH |
| ORP Resolution | 1 mV |
| Temperature Resolution | 0.1°C / 0.1°F |
| pH Accuracy | ±0.02 pH |
| ORP Accuracy | ±2 mV |
| Temperature Accuracy | ±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C) |
| Calibration | Auto 1- or 2-point with NIST/USA traceable buffers (pH 4.01/7.01/10.01 or 4.01/6.86/9.18) |
| Temperature Compensation | Automatic (ATC), -5.0 to 105.0°C |
| Electrode | HI1297D combination probe with integrated temperature sensor and DIN connector |
| Power | 3 × 1.5 V AA batteries |
| IP Rating | IP67 (dust-tight and submersible up to 1 m for 30 min) |
| Operating Environment | 0 to 50°C, ≤100% RH |
| Dimensions | 152 × 58 × 30 mm |
| Weight | 205 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | HI3221 |
| Instrument Type | Benchtop |
| Parameter Types | Multi-parameter |
| pH Accuracy | ±0.01 pH / ±0.002 pH |
| ORP Accuracy | ±0.2 mV |
| ISE Accuracy | ±0.5% of reading (monovalent), ±1% of reading (divalent) |
| Temperature Accuracy | ±0.4°C |
| pH Range | –2.0 to 20.000 pH |
| ORP Range | ±2000 mV |
| ISE Range | 1.00 × 10⁻³ to 1.00 × 10⁵ ppm |
| Temperature Range | –20.0 to 120.0°C |
| pH Resolution | 0.1 / 0.01 / 0.001 pH |
| ORP Resolution | 0.1 / 1 mV |
| ISE Resolution | 0.01 / 0.1 / 1 / 10 ppm |
| Temperature Resolution | 0.1°C |
| Calibration | Up to 5-point pH auto-calibration with 7 built-in NIST/USA standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 user-defined points |
| ISE Calibration | 2-point calibration with 6 stored standards (0.1, 1, 10, 100, 1000, 10000 ppm) |
| Temperature Compensation | Automatic or manual (–20.0 to 120.0°C) |
| Electrode Interface | BNC + dedicated temperature probe (HI7662) |
| Input Impedance | 10¹² Ω |
| Data Storage | Manual storage for 300 readings |
| Connectivity | USB interface (PC connection requires optional HI92000 software and cable) |
| Power Supply | 12 VDC adapter |
| Operating Environment | 0 to 50°C, max 55% RH |
| Dimensions & Weight | 235 × 207 × 110 mm, 1.8 kg |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | HI99141 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH) |
| Measurement Accuracy | ±0.02 pH |
| pH Range | -2.00 to 16.00 pH |
| Temperature Range | -5.0 to 105.0°C / 23.0 to 221.0°F |
| Resolution | 0.01 pH / 0.1°C / 0.1°F |
| Temperature Accuracy | ±0.5°C (-5 to 60°C), ±1.0°C (60 to 105.0°C) / ±1.0°F (23 to 140°F), ±2.0°F (140 to 221.0°F) |
| Calibration Standard | NIST/USA Traceable Buffers |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | HI99163 |
| Instrument Type | Portable |
| Parameter Count | Dual (pH and Temperature) |
| pH Accuracy | ±0.02 pH |
| pH Range | -2.00 to 16.00 pH |
| Temperature Range | -5.0 to 105.0 °C / 23.0 to 221.0 °F |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±1.0 °C / ±0.2 °F |
| Calibration Standard | NIST-Traceable and USA-Standard Buffers |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments, Inc. |
| Instrument Type | Portable |
| Parameter Types | pH, ORP, ISE, Temperature |
| pH Range | -2.000 to 20.000 |
| ORP Range | ±2000.0 mV |
| ISE Range | 1.00 × 10⁻⁷ to 9.99 × 10¹⁰ (concentration units selectable) |
| Temperature Range | -20.0 to 120.0 °C / -4.0 to 248.0 °F |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| ORP Resolution | 0.1 mV |
| ISE Resolution | 0.01 / 0.1 / 1 / 10 (unit-dependent) |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| pH Accuracy | ±0.01 (general), ±0.002 (high-precision mode) |
| ORP Accuracy | ±0.2 mV |
| ISE Accuracy | ±0.5% of reading (monovalent), ±1.0% (divalent) |
| Temperature Accuracy | ±0.4 °C / ±0.8 °F |
| Calibration Standards | NIST-traceable and USA-standard buffers |
| Calibration Points | Up to 5-point pH auto-recognition with 7 built-in standards |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0 °C) |
| Electrode Interface | BNC with integrated temperature sensor (input impedance ≥10¹² Ω) |
| Data Storage | Internal memory with USB interface |
| Power | 4×1.2 V AA rechargeable batteries + HI710042 inductive charger |
| IP Rating | IP67 waterproof and dustproof |
| Operating Environment | 0 to 50 °C, ≤95% RH (non-condensing) |
| Dimensions & Weight | 235 × 207 × 110 mm, 1.8 kg |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Benchtop pH Meter |
| Model | HI2215 |
| Measurement Parameters | pH, ORP, Temperature (°C/°F) |
| pH Range | –2.000 to 16.000 pH |
| ORP Range | ±999.9 mV and ±2000 mV |
| Temperature Range | –20.0 to 120.0 °C |
| pH Resolution | 0.1 / 0.01 / 0.001 pH |
| Temperature Resolution | 0.1 °C |
| ORP Resolution | 0.1 mV (±999.9 mV), 1 mV (±2000 mV) |
| Accuracy | ±0.01 pH |
| Calibration Standards | NIST-traceable buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) |
| Calibration Modes | Auto-5-point, manual 2-point, or custom calibration |
| Temperature Compensation | Automatic or manual (–20.0 to 120.0 °C) |
| Input Impedance | ≥10¹² Ω |
| Data Storage | 100 manual + 500 interval-stored readings |
| Interface | USB (with optional HI92000 software and HI920013 cable) |
| GLP Compliance | Yes (time-stamped calibration logs, electrode ID tracking, expiry alerts) |
Show next