Empowering Scientific Discovery

Hanna Instruments (China) Service Center

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypePortable
ModelHI847492
Measurement Range0.00–9.99 FTU, 10.0–99.9 FTU, 100–1000 FTU
Resolution0.01 FTU (0.00–9.99), 0.1 FTU (10.0–99.9), 1 FTU (100–1000)
Operating Temperature0 to 50°C (32 to 122°F)
Accuracy±2% of reading plus 0.05 FTU
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypePortable
ModelHI93124
Measurement Range0.00–10.00 EBC and 10–250 EBC
Resolution0.01 EBC
Accuracy±0.2 EBC or ±5% of reading (0.00–10.00 EBC)
Operating Temperature0–50 °C (32–122 °F)
Calibration3-point (0, 2.5, 125 EBC)
Light SourceInfrared LED (850 nm)
DetectorSilicon photodiode at 90°
ComplianceEPA Method 180.1, Standard Method 2130B, EBC Method 9.2
Data Storage199 measurements
InterfaceRS232 (cable and HI92000 software optional)
Power4 × 1.5 V AA batteries
Dimensions220 × 82 × 66 mm
Weight510 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeBenchtop / Laboratory
ModelHI88703
Measurement Range0.00–9.99 NTU, 10.0–40.0 NTU, 0.00–9.99 FNU, 10.0–99.9 FNU, 100–4000 NTU, 0.0–99.9 Nephelos, 100–26800 Nephelos, 0.00–9.99 EBC, 10.0–99.9 EBC, 100–980 EBC
Resolution±1% or 0.02 NTU (whichever is greater)
Accuracy±2% + 0.02 NTU (≤1000 NTU)
Operating Environment0–50°C (32–122°F), RH ≤95% non-condensing
Optical SystemTungsten lamp light source with silicon photodetector
CalibrationUp to 5-point calibration using standards at <0.1, 15, 100, 750, and 2000 NTU
ComplianceEPA Method 180.1, Standard Method 2130B
Data Storage200 measurement records with timestamp, calibration history, and operator ID
InterfaceUSB port for PC connectivity (cable & software optional)
Power Supply230 VAC / 50 Hz, 20 W
Dimensions & Weight230 × 200 × 145 mm, 2.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypePortable
ModelHI98703
Measurement Range0.00–9.99 NTU
Resolution±1% or 0.02 NTU (whichever is greater)
Accuracy±2% of reading + 0.02 NTU
Operating Temperature0 to 50°C (32 to 122°F)
Calibration Points0.1, 15, 100, and 750 NTU (2–4 point auto-recognized)
ComplianceUSEPA Method 180.1 & Standard Method 2130B
Data Storage200 measurement records
InterfaceUSB and RS232 (cable and HI92000 software optional)
Power4 × 1.5 V AA batteries or 12 V DC adapter
Dimensions224 × 87 × 77 mm
Weight512 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
TypeImported Instrument
ModelHI93414
Turbidity Range0.00–9.99 NTU
Chlorine Range0.00–5.00 mg/L (Free & Total)
Accuracy±2% of reading + 0.02 NTU (turbidity)
Resolution±1% of reading or 0.02 NTU (whichever is greater)
Operating Temperature0–50°C (32–122°F)
Calibration Standards0.1, 15, 100, 750 NTU (2–4 point auto-calibration)
Optical SystemTungsten lamp, silicon photodetector, 525 nm narrow-band interference filter
ComplianceEPA Method 180.1 & 2130B (turbidity)
Data Storage200 measurements
InterfaceUSB and RS232 (cable and software optional)
Power4 × 1.5 V AA batteries or 12 V DC adapter
Dimensions224 × 87 × 77 mm
Weight512 g
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0