Empowering Scientific Discovery

Hanna Instruments (China) Service Center

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypePortable Analyzer
ModelHI96771
Measurement PrincipleDPD Colorimetric Spectrophotometry
Free Chlorine Range0.00–5.00 mg/L
Chlorine UHR Range0–500 mg/L
AccuracyFree Chlorine: ±0.03 mg/L ±3% of reading @ 25°C
Chlorine UHR±3 mg/L ±3% of reading @ 25°C
RepeatabilityFree Chlorine: ±0.03 mg/L (±3% of reading @ 25°C)
ResolutionFree Chlorine: 0.01 mg/L (0.00–3.50 mg/L), 0.10 mg/L (>3.50 mg/L)
Chlorine UHR1 mg/L (0–200 mg/L), 10 mg/L (>200 mg/L)
LOD0.01 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelHI96701
Instrument TypeBenchtop/Lab-Grade Portable Photometer
Measurement PrincipleDPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine)
Measurement ParameterFree Chlorine (as Cl₂)
Range0.00 to 5.00 mg/L Cl₂
Accuracy±3% of reading ± 0.03 mg/L @ 25°C
Repeatability±0.03 mg/L
Resolution0.01 mg/L (0.00–3.50 mg/L)
Detection Limit0.00 mg/L
Optical SystemCustom LED Light Source & Silicon Photodetector
ComplianceEPA Method 330.5, Standard Methods 4500-Cl G
Power1 × 9 V battery (auto-off after 10 min idle)
Operating Environment0–50°C
Dimensions192 × 104 × 69 mm
Weight360 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeLaboratory Photometer
ModelHI96724
Measurement PrincipleDPD Colorimetric Method (Absorbance at 525 nm)
Measurement Range0.00 to 5.00 mg/L as Cl₂ (Free or Total Chlorine)
Accuracy±0.03 mg/L ±3% of reading @ 25°C
Repeatability±0.03 mg/L
Resolution0.01 mg/L (0.00–3.50 mg/L)
Detection Limit0.01 mg/L
ComplianceEPA Method 330.5, Standard Methods 4500-Cl.G
Power Supply1 × 9V battery (auto-off after 10 min idle)
Operating Environment0–50°C, ≤95% RH (non-condensing)
Dimensions192 × 104 × 69 mm
Weight360 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
ManufacturerHanna Instruments
Product TypeImported
ModelHI96762
Instrument TypePortable
Measurement PrincipleDPD Colorimetric Photometry (ASTM D1253, Standard Methods 4500-Cl G)
Measurement Range0.000 to 0.500 mg/L as Cl₂
Accuracy±0.020 mg/L ±3% of reading at 25°C
Repeatability±0.020 mg/L
Resolution0.001 mg/L
Limit of Detection0.001 mg/L
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0