- All
- Favorite
- Popular
- Most rated
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Type | Benchtop Conductivity Meter |
| Model | HI2315 |
| Measurement Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Conductivity Range | 0.0–199.9 µS/cm |
| TDS Range | 0–0.1 g/L |
| Resistivity Range | 0–0.1 MΩ·cm |
| Salinity Range | 0–0.1 ppt |
| Temperature Range | 0.0–50.0 °C |
| Accuracy | ±1% of full scale |
| Resolution | 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Imported Benchtop Instrument |
| Model | HI2030 |
| Conductivity Range | 0.000 to 500 mS/cm |
| TDS Range | 0.000 to 400.0 g/L (ppt) |
| Salinity Ranges | 0.00 to 42.00 PSU, 0.00 to 80.00 g/L (ppt), 0.0 to 400.0 % NaCl |
| Temperature Range | −20.0 to 120.0 °C (−4.0 to 248.0 °F) |
| Accuracy | ±1% of reading (±0.5 µS/cm or 1 digit, whichever greater) |
| Resolution | 0.01 µS/cm, 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm, 0.01 mg/L (ppm), 0.1 mg/L (ppm), 1 mg/L (ppm), 0.01 g/L, 0.1 g/L (0.8 TDS factor), 0.1% NaCl, 0.01 PSU |
| Calibration | Manual single-point |
| Temperature Compensation | Automatic (ATC) and No-Temperature Compensation (noTC) modes |
| TDS Conversion Factor | Adjustable 0.40–0.80 |
| Data Storage | 1000 total records (200 on-demand + 600 interval-logged) |
| Interface | Dual USB (Mini-USB for data transfer & charging |
| Brand | Hanna |
|---|---|
| Origin | Italy |
| Manufacturer | Hanna Instruments |
| Product Type | Imported Portable Conductivity Meter |
| Model | HI8733 |
| Measurement Parameters | Single-parameter (Conductivity/EC, TDS, Resistivity, Salinity, Temperature) |
| Conductivity Range | 0.0 to 199.9 µS/cm |
| TDS Range | 0 to 0.1 g/L |
| Resistivity Range | 0 to 0.1 MΩ·cm |
| Salinity Range | 0 to 0.1 ppt |
| Temperature Compensation | Automatic, 0 to 50 °C with adjustable β coefficient (0.0 to 2.5 %/°C) |
| Accuracy | ±1% of full scale |
| Resolution | 0.1 µS/cm |
| Power Supply | 1 × 9 V battery |
| Operating Environment | 0 to 50 °C, RH ≤ 100% |
| Dimensions | 145 × 80 × 36 mm |
| Weight | 230 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Imported |
| Model | HI98308 |
| Measurement Parameter | Conductivity (Single-Parameter) |
| Form Factor | Pen-Style Portable |
| Conductivity Range | 0.0 to 99.9 µS/cm |
| TDS Range | 0.000 to 0.001 g/L (ppm) |
| Resistivity Range | 0.0 to 10.0 MΩ·cm |
| Salinity Range | 0.00 to 0.01 ppt |
| Temperature Range | 0.0 to 50.0 °C |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.1 µS/cm |
| Calibration | Manual Single-Point (HI7033L recommended) |
| Temperature Compensation | Automatic (0 to 50 °C) |
| Power | 4 × 1.5 V AAA batteries |
| Operating Environment | 0 to 50 °C, ≤95% RH |
| Dimensions | 175 × 41 × 23 mm |
| Weight | 95 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | HI98312 |
| Measurement Parameters | EC, TDS, Temperature |
| Portability | Pen-Style |
| Conductivity Range | 0.00 to 20.00 mS/cm |
| TDS Range | 0.00 to 10.00 ppt (g/L) |
| Resistivity Range | 0 to 0.01 MΩ·cm |
| Salinity Range | 0 to 0.01 ppt |
| Temperature Range | 0.0 to 60.0°C / 32.0 to 140.0°F |
| Accuracy | ±2% F.S. (EC), ±2% F.S. (TDS), ±0.5°C / ±1°F (Temperature) |
| Resolution | 0.01 mS/cm, 0.01 ppt, 0.1°C, 0.1°F |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Imported |
| Model | HI98309 |
| Measurement Parameter | Single (Conductivity) |
| Form Factor | Pen-style |
| Conductivity Range | 0.000 to 1.999 µS/cm |
| TDS Range | 0 to 0.1 g/L |
| Resistivity Range | 0 to 0.1 MΩ·cm |
| Salinity Range | 0 to 0.1 ppt |
| Temperature Range | 0 to 50 °C (32 to 122 °F) |
| Accuracy | ±2% F.S. |
| Resolution | 0.001 µS/cm |
| Calibration | Factory-calibrated, no user calibration required |
| Power | 4 × 1.5 V button cells (LR44) |
| Dimensions | 175 × 41 × 23 mm |
| Weight | 95 g |
Show next