- All
- Favorite
- Popular
- Most rated
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Portable Analyzer |
| Model | HI96771 |
| Measurement Principle | DPD Colorimetric Spectrophotometry |
| Free Chlorine Range | 0.00–5.00 mg/L |
| Chlorine UHR Range | 0–500 mg/L |
| Accuracy | Free Chlorine: ±0.03 mg/L ±3% of reading @ 25°C |
| Chlorine UHR | ±3 mg/L ±3% of reading @ 25°C |
| Repeatability | Free Chlorine: ±0.03 mg/L (±3% of reading @ 25°C) |
| Resolution | Free Chlorine: 0.01 mg/L (0.00–3.50 mg/L), 0.10 mg/L (>3.50 mg/L) |
| Chlorine UHR | 1 mg/L (0–200 mg/L), 10 mg/L (>200 mg/L) |
| LOD | 0.01 mg/L |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Laboratory Instrument |
| Model | HI2221 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Brand | Hanna Instruments |
|---|---|
| Model | HI96700 |
| Measurement Range | 0.00–3.00 mg/L NH₃–N |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.04 mg/L ±4% of reading |
| Optical System | Tungsten lamp, narrow-band interference filter @ 420 nm, silicon photodetector |
| Method | ASTM D1426-93 Nesslerization |
| Calibration | CAL CHECK® single-point verification with optional NIST-traceable standards |
| Power | 1 × 9 V battery |
| Dimensions | 192 × 102 × 67 mm |
| Weight | 290 g |
| Operating Environment | 0–50 °C, ≤95% RH (non-condensing) |
| Compliance | ISO/IEC 17025, GLP, EPA-compliant methodology |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI83200 |
| Instrument Type | Laboratory-Based Multiparameter Photometer |
| Key Features | 45-parameter photometric analysis, dual-range measurement capability, integrated light-shielding cuvette chamber, backlit LCD with on-screen guidance, BEPS battery protection, GLP-compliant data logging (200 sets), USB interface for HI92000 software connectivity, 4-wavelength optical system (420 nm, 525 nm, 575 nm, 610 nm), tungsten lamp source, silicon photodetector |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | HI83099 |
| Instrument Type | Multiparameter Ion Photometer |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | HI96706 |
| Instrument Type | Multi-Ion Photometer |
| Measurement Range | 0.0 to 15.0 mg/L P |
| Resolution | 0.1 mg/L |
| Accuracy | ±0.2 mg/L @ 6.0 mg/L |
| Optical System | Tungsten lamp, narrow-band interference filter @ 525 nm, silicon photodetector |
| Calibration | CAL CHECK® single-point verification with NIST-traceable standards |
| Method | Amino Acid Method (modified Standard Methods for the Examination of Water and Wastewater) |
| Power | 1 × 9V battery (≈200 h operation) |
| Environmental Rating | IP67 (0 to 50 °C |
| Dimensions & Weight | 192 × 102 × 67 mm |
| Compliance | EPA Compliant, ISO/IEC 17025-aligned calibration traceability, GLP data logging (calibration date, user ID, time stamp) |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI96701 |
| Instrument Type | Benchtop/Lab-Grade Portable Photometer |
| Measurement Principle | DPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine) |
| Measurement Parameter | Free Chlorine (as Cl₂) |
| Range | 0.00 to 5.00 mg/L Cl₂ |
| Accuracy | ±3% of reading ± 0.03 mg/L @ 25°C |
| Repeatability | ±0.03 mg/L |
| Resolution | 0.01 mg/L (0.00–3.50 mg/L) |
| Detection Limit | 0.00 mg/L |
| Optical System | Custom LED Light Source & Silicon Photodetector |
| Compliance | EPA Method 330.5, Standard Methods 4500-Cl G |
| Power | 1 × 9 V battery (auto-off after 10 min idle) |
| Operating Environment | 0–50°C |
| Dimensions | 192 × 104 × 69 mm |
| Weight | 360 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Manufacturer | Hanna Instruments S.p.A. |
| Type | Portable |
| Measurement Principle | Electrochemical (Galvanic Cell) |
| Range | 0.00 to 45.00 mg/L |
| Accuracy | ±1.5% F.S. |
| Repeatability | ±1.5% F.S. |
| Detection Limit | 0.01 mg/L |
| Temperature Range | 0.0 to 50.0 °C |
| Temperature Accuracy | ±0.2 °C (excluding probe error) |
| Resolution | 0.01 mg/L DO, 0.1 % sat, 0.1 °C |
| Altitude Compensation | 0 to 4000 m (100 m steps) |
| Salinity Compensation | 0 to 80 g/L (1 g/L steps) |
| Power | 3×1.5 V AAA batteries |
| IP Rating | IP67 |
| Dimensions | 185 × 72 × 36 mm |
| Weight | 300 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI96769 |
| Instrument Type | Multi-Ion Photometer |
| Measurement Range | 0.00 to 3.50 mg/L as SDBS |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.04 mg/L @ 1.00 mg/L |
| Optical System | Tungsten lamp, narrow-band interference filter @ 610 nm, silicon photodetector |
| Calibration | CAL CHECK® single-point verification with NIST-traceable standards |
| Method Compliance | EPA Method 425.1, Standard Methods 20th Ed. 5540C |
| Power Supply | 1 × 9 V battery |
| Operating Environment | 0 to 50 °C |
| Dimensions & Weight | 192 × 102 × 67 mm |
| Display | Dual-line LCD with calibration date, low-battery indicator, and timer status |
| Features | Auto-shutdown, READ/TIMER function, waterproof housing (IP67), cuvette positioning guide, large-diameter cuvette port |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Manufacturer | Hanna Instruments S.p.A. |
| Type | Laboratory Benchtop Meter |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Range | 0.00 to 45.00 mg/L (ppm) |
| Saturation Range | 0.0 to 300.0 % |
| Accuracy | ±1.5% of reading ±1 digit |
| Repeatability | ±1.5% of reading ±1 digit |
| Detection Limit | ±1.5% of reading ±1 digit |
| Temperature Compensation | Automatic (ATC), -20.0 to 120.0 °C |
| Altitude Compensation | -500 to 4000 m |
| Salinity Compensation | 0 to 40 g/L |
| Data Storage | 1000 total records (200 on-demand + 600 interval-logged) |
| Interface | Dual USB (Mini-USB for data transfer & charging |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Imported |
| Model | HI96715 |
| Instrument Type | Ammonia Ion Photometer |
| Measurement Range | 0.00–9.99 mg/L NH₃–N |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.12 mg/L @ 6.00 mg/L |
| Optical System | Tungsten lamp, narrow-band interference filter @ 466 nm, silicon photodetector |
| Calibration | CAL CHECK® single-point verification with optional NIST-traceable standards |
| Method | ASTM D1426-93 (Nesslerization) |
| Power | 1 × 9 V battery |
| Operating Environment | 0–50 °C |
| Dimensions & Weight | 192 × 102 × 67 mm |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Manufacturer | Hanna Instruments S.p.A. |
| Type | Portable |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| DO Range | 0.00–50.00 mg/L (ppm), 0.0–300.0 % saturation |
| Accuracy | ±0.01 mg/L, ±0.1 % sat |
| Repeatability | ±0.01 mg/L, ±0.1 % sat |
| Detection Limit | 0.01 mg/L, 0.1 % sat |
| Temperature Range | –20.0 to 120.0 °C |
| Barometric Pressure Range | 450–850 mmHg |
| Resolution | DO: 0.01 mg/L / 0.1 % |
| Temp | 0.1 °C |
| Pressure | 1 mmHg |
| Calibration | Single-point air-saturation calibration |
| Compensation | Automatic temperature (0–50 °C), salinity (0–70 ppt), and pressure |
| Data Storage | 400 records with timestamp |
| Interface | USB (cable and software optional) |
| Power | 4 × 1.2 V AA rechargeable NiMH batteries with inductive charging |
| IP Rating | IP67 |
| Dimensions & Weight | 226.5 × 95 × 52 mm, 525 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments, Inc. |
| Model | HI2550 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Calibration Standards | ASTM D1125 (conductivity), ISO 7888 (TDS), USP <645> (water conductivity for pharmaceutical use) |
| Data Integrity | USB export, GLP-compliant timestamped records, audit-ready calibration logs |
| Brand | Hanna Instruments |
|---|---|
| Model | HI96725 |
| Type | Portable Photometric Water Quality Analyzer |
| Origin | USA (Manufactured by Hanna Instruments, USA) |
| Compliance | EPA-Compliant Methods, ISO 7027 & ISO 9297, GLP/GMP-Ready with Audit Trail Support |
| Measurement Principles | DPD Colorimetry (Cl₂), Methyl Orange/Bromocresol Green Titration (pH), Turbidimetric Method (Cyanuric Acid) |
| Power | 4×AAA Batteries (up to 10,000 measurements per set) |
| IP Rating | IP67 Dust/Water Resistant |
| Display | Dual-line LCD with backlight |
| Auto-off | Configurable (1–60 min) |
| Data Storage | 200 Sample Records with Timestamp & Operator ID |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Manufacturer | Hanna Instruments S.p.A. |
| Model | HI9147/04 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| DO Range | 0.0 to 50.0 mg/L |
| Saturation Range | 0 to 600 % |
| Temperature Range | −5.0 to 50.0 °C |
| Resolution | DO: 0.1 mg/L |
| Saturation | 1 % |
| Temperature | 0.1 °C |
| Accuracy (at 20 °C) | DO: ±1 % F.S. |
| Saturation | ±1 % F.S. |
| Temperature | ±0.2 °C (excluding probe error) |
| Detection Limit | 0.1 mg/L |
| Salinity Compensation | 0 to 51 g/L (1 g/L resolution) |
| Auto-Temperature Compensation | −5 to 50 °C |
| Calibration | Automatic single-point calibration in air |
| Power | 9 V alkaline battery (IEC 6LR61) |
| Auto-Off | After 6 minutes of inactivity |
| IP Rating | IP67 |
| Dimensions | 196 × 80 × 60 mm |
| Weight | 500 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Laboratory Photometer |
| Model | HI96724 |
| Measurement Principle | DPD Colorimetric Method (Absorbance at 525 nm) |
| Measurement Range | 0.00 to 5.00 mg/L as Cl₂ (Free or Total Chlorine) |
| Accuracy | ±0.03 mg/L ±3% of reading @ 25°C |
| Repeatability | ±0.03 mg/L |
| Resolution | 0.01 mg/L (0.00–3.50 mg/L) |
| Detection Limit | 0.01 mg/L |
| Compliance | EPA Method 330.5, Standard Methods 4500-Cl.G |
| Power Supply | 1 × 9V battery (auto-off after 10 min idle) |
| Operating Environment | 0–50°C, ≤95% RH (non-condensing) |
| Dimensions | 192 × 104 × 69 mm |
| Weight | 360 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Imported |
| Model | HI96762 |
| Instrument Type | Portable |
| Measurement Principle | DPD Colorimetric Photometry (ASTM D1253, Standard Methods 4500-Cl G) |
| Measurement Range | 0.000 to 0.500 mg/L as Cl₂ |
| Accuracy | ±0.020 mg/L ±3% of reading at 25°C |
| Repeatability | ±0.020 mg/L |
| Resolution | 0.001 mg/L |
| Limit of Detection | 0.001 mg/L |
Show next