| Brand | Hanna Instruments |
|---|---|
| Model | HI96700 |
| Measurement Range | 0.00–3.00 mg/L NH₃–N |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.04 mg/L ±4% of reading |
| Optical System | Tungsten lamp, narrow-band interference filter @ 420 nm, silicon photodetector |
| Method | ASTM D1426-93 Nesslerization |
| Calibration | CAL CHECK® single-point verification with optional NIST-traceable standards |
| Power | 1 × 9 V battery |
| Dimensions | 192 × 102 × 67 mm |
| Weight | 290 g |
| Operating Environment | 0–50 °C, ≤95% RH (non-condensing) |
| Compliance | ISO/IEC 17025, GLP, EPA-compliant methodology |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | HI83099 |
| Instrument Type | Multiparameter Ion Photometer |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | HI96706 |
| Instrument Type | Multi-Ion Photometer |
| Measurement Range | 0.0 to 15.0 mg/L P |
| Resolution | 0.1 mg/L |
| Accuracy | ±0.2 mg/L @ 6.0 mg/L |
| Optical System | Tungsten lamp, narrow-band interference filter @ 525 nm, silicon photodetector |
| Calibration | CAL CHECK® single-point verification with NIST-traceable standards |
| Method | Amino Acid Method (modified Standard Methods for the Examination of Water and Wastewater) |
| Power | 1 × 9V battery (≈200 h operation) |
| Environmental Rating | IP67 (0 to 50 °C |
| Dimensions & Weight | 192 × 102 × 67 mm |
| Compliance | EPA Compliant, ISO/IEC 17025-aligned calibration traceability, GLP data logging (calibration date, user ID, time stamp) |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI96769 |
| Instrument Type | Multi-Ion Photometer |
| Measurement Range | 0.00 to 3.50 mg/L as SDBS |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.04 mg/L @ 1.00 mg/L |
| Optical System | Tungsten lamp, narrow-band interference filter @ 610 nm, silicon photodetector |
| Calibration | CAL CHECK® single-point verification with NIST-traceable standards |
| Method Compliance | EPA Method 425.1, Standard Methods 20th Ed. 5540C |
| Power Supply | 1 × 9 V battery |
| Operating Environment | 0 to 50 °C |
| Dimensions & Weight | 192 × 102 × 67 mm |
| Display | Dual-line LCD with calibration date, low-battery indicator, and timer status |
| Features | Auto-shutdown, READ/TIMER function, waterproof housing (IP67), cuvette positioning guide, large-diameter cuvette port |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Imported |
| Model | HI96715 |
| Instrument Type | Ammonia Ion Photometer |
| Measurement Range | 0.00–9.99 mg/L NH₃–N |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.12 mg/L @ 6.00 mg/L |
| Optical System | Tungsten lamp, narrow-band interference filter @ 466 nm, silicon photodetector |
| Calibration | CAL CHECK® single-point verification with optional NIST-traceable standards |
| Method | ASTM D1426-93 (Nesslerization) |
| Power | 1 × 9 V battery |
| Operating Environment | 0–50 °C |
| Dimensions & Weight | 192 × 102 × 67 mm |