BrandHanna Instruments
ModelHI96700
Measurement Range0.00–3.00 mg/L NH₃–N
Resolution0.01 mg/L
Accuracy±0.04 mg/L ±4% of reading
Optical SystemTungsten lamp, narrow-band interference filter @ 420 nm, silicon photodetector
MethodASTM D1426-93 Nesslerization
CalibrationCAL CHECK® single-point verification with optional NIST-traceable standards
Power1 × 9 V battery
Dimensions192 × 102 × 67 mm
Weight290 g
Operating Environment0–50 °C, ≤95% RH (non-condensing)
ComplianceISO/IEC 17025, GLP, EPA-compliant methodology
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeManufacturer
Product CategoryImported Instrument
ModelHI83099
Instrument TypeMultiparameter Ion Photometer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeManufacturer
Product CategoryImported
ModelHI96706
Instrument TypeMulti-Ion Photometer
Measurement Range0.0 to 15.0 mg/L P
Resolution0.1 mg/L
Accuracy±0.2 mg/L @ 6.0 mg/L
Optical SystemTungsten lamp, narrow-band interference filter @ 525 nm, silicon photodetector
CalibrationCAL CHECK® single-point verification with NIST-traceable standards
MethodAmino Acid Method (modified Standard Methods for the Examination of Water and Wastewater)
Power1 × 9V battery (≈200 h operation)
Environmental RatingIP67 (0 to 50 °C
Dimensions & Weight192 × 102 × 67 mm
ComplianceEPA Compliant, ISO/IEC 17025-aligned calibration traceability, GLP data logging (calibration date, user ID, time stamp)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelHI96769
Instrument TypeMulti-Ion Photometer
Measurement Range0.00 to 3.50 mg/L as SDBS
Resolution0.01 mg/L
Accuracy±0.04 mg/L @ 1.00 mg/L
Optical SystemTungsten lamp, narrow-band interference filter @ 610 nm, silicon photodetector
CalibrationCAL CHECK® single-point verification with NIST-traceable standards
Method ComplianceEPA Method 425.1, Standard Methods 20th Ed. 5540C
Power Supply1 × 9 V battery
Operating Environment0 to 50 °C
Dimensions & Weight192 × 102 × 67 mm
DisplayDual-line LCD with calibration date, low-battery indicator, and timer status
FeaturesAuto-shutdown, READ/TIMER function, waterproof housing (IP67), cuvette positioning guide, large-diameter cuvette port
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginUSA
Manufacturer TypeOEM Manufacturer
Product OriginImported
ModelHI96715
Instrument TypeAmmonia Ion Photometer
Measurement Range0.00–9.99 mg/L NH₃–N
Resolution0.01 mg/L
Accuracy±0.12 mg/L @ 6.00 mg/L
Optical SystemTungsten lamp, narrow-band interference filter @ 466 nm, silicon photodetector
CalibrationCAL CHECK® single-point verification with optional NIST-traceable standards
MethodASTM D1426-93 (Nesslerization)
Power1 × 9 V battery
Operating Environment0–50 °C
Dimensions & Weight192 × 102 × 67 mm