Empowering Scientific Discovery

Hanna Instruments (China) Service Center

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ManufacturerHanna Instruments S.p.A.
TypePortable
Measurement PrincipleElectrochemical (Galvanic Cell)
Range0.00 to 45.00 mg/L
Accuracy±1.5% F.S.
Repeatability±1.5% F.S.
Detection Limit0.01 mg/L
Temperature Range0.0 to 50.0 °C
Temperature Accuracy±0.2 °C (excluding probe error)
Resolution0.01 mg/L DO, 0.1 % sat, 0.1 °C
Altitude Compensation0 to 4000 m (100 m steps)
Salinity Compensation0 to 80 g/L (1 g/L steps)
Power3×1.5 V AAA batteries
IP RatingIP67
Dimensions185 × 72 × 36 mm
Weight300 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ManufacturerHanna Instruments S.p.A.
TypeLaboratory Benchtop Meter
Measurement PrincipleGalvanic Cell Electrochemical Probe
Range0.00 to 45.00 mg/L (ppm)
Saturation Range0.0 to 300.0 %
Accuracy±1.5% of reading ±1 digit
Repeatability±1.5% of reading ±1 digit
Detection Limit±1.5% of reading ±1 digit
Temperature CompensationAutomatic (ATC), -20.0 to 120.0 °C
Altitude Compensation-500 to 4000 m
Salinity Compensation0 to 40 g/L
Data Storage1000 total records (200 on-demand + 600 interval-logged)
InterfaceDual USB (Mini-USB for data transfer & charging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ManufacturerHanna Instruments S.p.A.
TypePortable
Measurement PrincipleElectrochemical Galvanic Cell Probe
DO Range0.00–50.00 mg/L (ppm), 0.0–300.0 % saturation
Accuracy±0.01 mg/L, ±0.1 % sat
Repeatability±0.01 mg/L, ±0.1 % sat
Detection Limit0.01 mg/L, 0.1 % sat
Temperature Range–20.0 to 120.0 °C
Barometric Pressure Range450–850 mmHg
ResolutionDO: 0.01 mg/L / 0.1 %
Temp0.1 °C
Pressure1 mmHg
CalibrationSingle-point air-saturation calibration
CompensationAutomatic temperature (0–50 °C), salinity (0–70 ppt), and pressure
Data Storage400 records with timestamp
InterfaceUSB (cable and software optional)
Power4 × 1.2 V AA rechargeable NiMH batteries with inductive charging
IP RatingIP67
Dimensions & Weight226.5 × 95 × 52 mm, 525 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanna Instruments
OriginItaly
ManufacturerHanna Instruments S.p.A.
ModelHI9147/04
Instrument TypePortable
Measurement PrincipleGalvanic Cell Electrochemical Probe
DO Range0.0 to 50.0 mg/L
Saturation Range0 to 600 %
Temperature Range−5.0 to 50.0 °C
ResolutionDO: 0.1 mg/L
Saturation1 %
Temperature0.1 °C
Accuracy (at 20 °C)DO: ±1 % F.S.
Saturation±1 % F.S.
Temperature±0.2 °C (excluding probe error)
Detection Limit0.1 mg/L
Salinity Compensation0 to 51 g/L (1 g/L resolution)
Auto-Temperature Compensation−5 to 50 °C
CalibrationAutomatic single-point calibration in air
Power9 V alkaline battery (IEC 6LR61)
Auto-OffAfter 6 minutes of inactivity
IP RatingIP67
Dimensions196 × 80 × 60 mm
Weight500 g
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0