- All
- Favorite
- Popular
- Most rated
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | HI98150 |
| Instrument Type | Portable |
| Parameter Types | Dual (pH + ORP) |
| Measurement Range | -4.0 to 20.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Calibration Standards | NIST-traceable and USA-standard buffer solutions |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Benchtop |
| Parameters Measured | pH, ORP, Temperature |
| pH Range | -2.00 to 16.00 |
| ORP Range | ±399.9 mV and ±2000 mV |
| Temperature Range | -9.9 to 120.0 °C |
| pH Resolution | 0.01 |
| ORP Resolution | 0.1 mV (±399.9 mV), 1 mV (±2000 mV) |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 |
| ORP Accuracy | ±0.2 mV (±399.9 mV), ±1 mV (±2000 mV) |
| Temperature Accuracy | ±0.5 °C (0.0–100.0 °C), ±1.0 °C (remaining range) |
| Calibration Standards | NIST/USA traceable buffers |
| Calibration Points | Auto-recognized 1-point or 2-point |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0 °C) |
| Input Impedance | 10¹² Ω |
| Electrode Interface | BNC |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Benchtop pH Meter |
| Model | HI2212 |
| Measurement Parameters | pH and Temperature (°C) |
| pH Range | -2.00 to 16.00 pH |
| Temperature Range | -20.0 to 120.0 °C |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH @ 20°C |
| Temperature Accuracy | ±0.4 °C (excluding probe error) |
| Calibration Standards | NIST-traceable or USA-standard buffers |
| Calibration Method | Automatic 3-point with 5 built-in standard points (pH 4.01, 6.86, 7.01, 9.18, 10.01) |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0 °C) |
| Input Impedance | 10¹² Ω |
| Electrode Interface | BNC |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Producer |
| Country of Origin | Imported |
| Model | HI98501 |
| Price | USD 720 (FOB) |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HI83141 |
| Instrument Type | Portable |
| Parameter Channels | Dual (pH + ORP) |
| pH Range | 0.00 to 14.00 |
| ORP Range | ±1999 mV |
| Temperature Range | 0.0 to 100.0 °C |
| pH Resolution | 0.01 |
| ORP Resolution | 1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 |
| ORP Accuracy | ±1 mV |
| Temperature Accuracy | ±0.4 °C (excluding probe error) |
| Calibration Standards | NIST-traceable and USA-standard buffer solutions |
| Calibration Method | Manual two-point pH calibration (with optional single-point ORP verification) |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Portable Analyzer |
| Model | HI96771 |
| Measurement Principle | DPD Colorimetric Spectrophotometry |
| Free Chlorine Range | 0.00–5.00 mg/L |
| Chlorine UHR Range | 0–500 mg/L |
| Accuracy | Free Chlorine: ±0.03 mg/L ±3% of reading @ 25°C |
| Chlorine UHR | ±3 mg/L ±3% of reading @ 25°C |
| Repeatability | Free Chlorine: ±0.03 mg/L (±3% of reading @ 25°C) |
| Resolution | Free Chlorine: 0.01 mg/L (0.00–3.50 mg/L), 0.10 mg/L (>3.50 mg/L) |
| Chlorine UHR | 1 mg/L (0–200 mg/L), 10 mg/L (>200 mg/L) |
| LOD | 0.01 mg/L |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Laboratory Instrument |
| Model | HI2221 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Type | Benchtop Conductivity Meter |
| Model | HI2315 |
| Measurement Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Conductivity Range | 0.0–199.9 µS/cm |
| TDS Range | 0–0.1 g/L |
| Resistivity Range | 0–0.1 MΩ·cm |
| Salinity Range | 0–0.1 ppt |
| Temperature Range | 0.0–50.0 °C |
| Accuracy | ±1% of full scale |
| Resolution | 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Imported Benchtop Instrument |
| Model | HI2030 |
| Conductivity Range | 0.000 to 500 mS/cm |
| TDS Range | 0.000 to 400.0 g/L (ppt) |
| Salinity Ranges | 0.00 to 42.00 PSU, 0.00 to 80.00 g/L (ppt), 0.0 to 400.0 % NaCl |
| Temperature Range | −20.0 to 120.0 °C (−4.0 to 248.0 °F) |
| Accuracy | ±1% of reading (±0.5 µS/cm or 1 digit, whichever greater) |
| Resolution | 0.01 µS/cm, 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm, 0.01 mg/L (ppm), 0.1 mg/L (ppm), 1 mg/L (ppm), 0.01 g/L, 0.1 g/L (0.8 TDS factor), 0.1% NaCl, 0.01 PSU |
| Calibration | Manual single-point |
| Temperature Compensation | Automatic (ATC) and No-Temperature Compensation (noTC) modes |
| TDS Conversion Factor | Adjustable 0.40–0.80 |
| Data Storage | 1000 total records (200 on-demand + 600 interval-logged) |
| Interface | Dual USB (Mini-USB for data transfer & charging |
| Brand | Hanna Instruments |
|---|---|
| Model | HI96700 |
| Measurement Range | 0.00–3.00 mg/L NH₃–N |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.04 mg/L ±4% of reading |
| Optical System | Tungsten lamp, narrow-band interference filter @ 420 nm, silicon photodetector |
| Method | ASTM D1426-93 Nesslerization |
| Calibration | CAL CHECK® single-point verification with optional NIST-traceable standards |
| Power | 1 × 9 V battery |
| Dimensions | 192 × 102 × 67 mm |
| Weight | 290 g |
| Operating Environment | 0–50 °C, ≤95% RH (non-condensing) |
| Compliance | ISO/IEC 17025, GLP, EPA-compliant methodology |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI83200 |
| Instrument Type | Laboratory-Based Multiparameter Photometer |
| Key Features | 45-parameter photometric analysis, dual-range measurement capability, integrated light-shielding cuvette chamber, backlit LCD with on-screen guidance, BEPS battery protection, GLP-compliant data logging (200 sets), USB interface for HI92000 software connectivity, 4-wavelength optical system (420 nm, 525 nm, 575 nm, 610 nm), tungsten lamp source, silicon photodetector |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | HI83099 |
| Instrument Type | Multiparameter Ion Photometer |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments, Inc. |
| Product Type | Portable pH Meter |
| Parameter Type | Single-Parameter (pH + Temperature) |
| pH Accuracy | ±0.02 pH |
| pH Range | −2.00 to 16.00 pH |
| Temperature Range | −5.0 to 105.0 °C / 23.0 to 221.0 °F |
| pH Resolution | 0.01 pH |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.5 °C (−5 to 60 °C), ±1.0 °C (60 to 105.0 °C) |
| Calibration Standards | NIST-traceable or USA-standard pH buffers |
| Calibration Modes | Automatic 1- or 2-point calibration with built-in buffer recognition (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18) |
| Electrode | HI1296D stainless steel body pH electrode with integrated Pt1000 temperature sensor |
| ATC Range | −5.0 to 105.5 °C |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Portable |
| Model | HI847492 |
| Measurement Range | 0.00–9.99 FTU, 10.0–99.9 FTU, 100–1000 FTU |
| Resolution | 0.01 FTU (0.00–9.99), 0.1 FTU (10.0–99.9), 1 FTU (100–1000) |
| Operating Temperature | 0 to 50°C (32 to 122°F) |
| Accuracy | ±2% of reading plus 0.05 FTU |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | HI96706 |
| Instrument Type | Multi-Ion Photometer |
| Measurement Range | 0.0 to 15.0 mg/L P |
| Resolution | 0.1 mg/L |
| Accuracy | ±0.2 mg/L @ 6.0 mg/L |
| Optical System | Tungsten lamp, narrow-band interference filter @ 525 nm, silicon photodetector |
| Calibration | CAL CHECK® single-point verification with NIST-traceable standards |
| Method | Amino Acid Method (modified Standard Methods for the Examination of Water and Wastewater) |
| Power | 1 × 9V battery (≈200 h operation) |
| Environmental Rating | IP67 (0 to 50 °C |
| Dimensions & Weight | 192 × 102 × 67 mm |
| Compliance | EPA Compliant, ISO/IEC 17025-aligned calibration traceability, GLP data logging (calibration date, user ID, time stamp) |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Benchtop |
| Parameters Measured | pH and Temperature |
| pH Range | -2.00 to 16.00 |
| Temperature Range | -20.0 to 120.0 °C |
| pH Resolution | 0.01 |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 at 20 °C |
| Temperature Accuracy | ±0.4 °C (0.0 to 100.0 °C), ±1.0 °C (remaining range) |
| Calibration | Auto-recognizing 1- or 2-point calibration with built-in NIST-traceable standards (pH 4.01, 6.86, 7.01, 9.18, 10.01) |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0 °C) |
| Input Impedance | 10¹² Ω |
| Electrode Interface | BNC |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Imported |
| Model | HI9125 |
| Instrument Type | Portable |
| Parameter Types | Dual (pH & ORP) |
| Measurement Accuracy | ±0.01 pH |
| pH Range | -2.00 to 16.00 |
| ORP Range | ±699.9 mV |
| Temperature Range | -20.0 to 120.0°C / -4.0 to 248.0°F |
| Resolution | 0.01 pH |
| Accuracy (excluding probe error) | ±0.01 pH |
| Calibration Standards | NIST-traceable and USA-certified buffers |
| Brand | Hanna |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Country of Origin | Imported |
| Model | HI9241 |
| Temperature Range | -50.0 to 150.0 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.4 °C @ 20 °C (excluding probe error) |
| Probe Type | HI765PW stainless steel penetration probe |
| Response Time | 6 seconds |
| Power Supply | 3 × 1.5 V AAA batteries |
| Auto-off | 8 minutes of inactivity |
| Operating Environment | -10 to 50 °C, 100 % RH (non-condensing) |
| Dimensions | 152 × 58 × 30 mm |
| Weight | 205 g |
| IP Rating | IP67 (waterproof & dustproof) |
| Display | Large backlit LCD |
| Interface | One-button operation |
| Battery Indicator | Integrated low-battery icon |
| Compliance | Meets ISO 17025 traceability requirements for field temperature verification |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Portable |
| Model | HI93124 |
| Measurement Range | 0.00–10.00 EBC and 10–250 EBC |
| Resolution | 0.01 EBC |
| Accuracy | ±0.2 EBC or ±5% of reading (0.00–10.00 EBC) |
| Operating Temperature | 0–50 °C (32–122 °F) |
| Calibration | 3-point (0, 2.5, 125 EBC) |
| Light Source | Infrared LED (850 nm) |
| Detector | Silicon photodiode at 90° |
| Compliance | EPA Method 180.1, Standard Method 2130B, EBC Method 9.2 |
| Data Storage | 199 measurements |
| Interface | RS232 (cable and HI92000 software optional) |
| Power | 4 × 1.5 V AA batteries |
| Dimensions | 220 × 82 × 66 mm |
| Weight | 510 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HI8424 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Range | -2.00 to 16.00 pH |
| ORP Range | ±699.9 mV and ±1999 mV |
| Temperature Range | -20.0 to 120.0 °C |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 pH |
| ORP Resolution | 0.1 mV / 1 mV |
| ORP Accuracy | ±0.2 mV (±699.9 mV), ±1 mV (±1999 mV) |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Calibration Points | Auto-recognized pH 4.01, 7.01, 10.01 |
| Calibration Method | Automatic 1- or 2-point |
| Temperature Compensation | Automatic or Manual (-20.0 to 120.0 °C) |
| Electrode Interface | BNC |
| Input Impedance | 10¹² Ω |
| Power Supply | 1 × 9 V rechargeable battery (inductive charging compatible) |
| IP Rating | IP67 |
| Operating Environment | 0 to 50 °C, RH ≤ 100% |
| Dimensions | 164 × 76 × 45 mm |
| Weight | 180 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | HI98107 |
| Instrument Type | Pen-Style |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0.0 to 14.0 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.1 pH |
| Calibration | Manual Two-Point Calibration (NIST/USA Traceable Buffers) |
| Electrode | Integrated HI73106 Combination pH Electrode |
| Power Supply | 4 × 1.5 V AAA Batteries |
| Operating Environment | 0 to 50 °C (32 to 122 °F) |
| Dimensions & Weight | 175 × 41 × 23 mm |
| Brand | Hanna |
|---|---|
| Origin | Italy |
| Manufacturer | Hanna Instruments |
| Product Type | Imported Portable Conductivity Meter |
| Model | HI8733 |
| Measurement Parameters | Single-parameter (Conductivity/EC, TDS, Resistivity, Salinity, Temperature) |
| Conductivity Range | 0.0 to 199.9 µS/cm |
| TDS Range | 0 to 0.1 g/L |
| Resistivity Range | 0 to 0.1 MΩ·cm |
| Salinity Range | 0 to 0.1 ppt |
| Temperature Compensation | Automatic, 0 to 50 °C with adjustable β coefficient (0.0 to 2.5 %/°C) |
| Accuracy | ±1% of full scale |
| Resolution | 0.1 µS/cm |
| Power Supply | 1 × 9 V battery |
| Operating Environment | 0 to 50 °C, RH ≤ 100% |
| Dimensions | 145 × 80 × 36 mm |
| Weight | 230 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | HI3222 |
| Instrument Type | Benchtop |
| Parameter Types | pH, ORP, ISE, Temperature |
| pH Accuracy | ±0.01 pH / ±0.002 pH |
| ORP Accuracy | ±0.2 mV |
| ISE Accuracy | ±0.5% of reading (monovalent), ±1% of reading (divalent) |
| Temperature Accuracy | ±0.4°C |
| pH Range | –2.0 to 20.000 pH (selectable resolution: 0.1 / 0.01 / 0.001 pH) |
| ORP Range | ±2000 mV (resolution: 0.1 mV / 1 mV) |
| ISE Range | 1.00 × 10⁻⁷ to 1.00 × 10¹⁰ (units selectable: ppm, mol/L, mg/L, %, etc.) |
| Temperature Range | –20.0 to 120.0°C (resolution: 0.1°C) |
| Calibration | Up to 5-point pH auto-calibration with 7 built-in NIST/USA standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 user-defined points |
| ISE Calibration | Up to 5-point with 6 stored standards (0.1–10,000 concentration units) |
| Temperature Compensation | Automatic or manual (–20.0 to 120.0°C) |
| Input Impedance | ≥10¹² Ω |
| Data Storage | Manual — 400 records |
| Auto — 1000 records (configurable intervals | 5 s to 180 min) |
| Connectivity | USB interface (requires optional HI92000 software and cable) |
| Display | Backlit LCD with real-time status icons and electrode performance feedback |
| Power Supply | 12 VDC adapter |
| Operating Environment | 0 to 50°C, ≤55% RH |
| Dimensions & Weight | 235 × 207 × 110 mm, 1.8 kg |
| Brand | Hanna Instruments |
|---|---|
| Origin | USA |
| Manufacturer | Hanna Instruments |
| Product Type | Portable |
| Measurement Parameters | pH & ORP (dual-parameter) |
| pH Range | -2.00 to 16.00 |
| ORP Range | ±699.9 mV and ±1999 mV |
| Temperature Range | -20.0 to 120.0°C (-4.0 to 248.0°F) |
| pH Resolution | 0.01 |
| ORP Resolution | 0.1 mV (±699.9 mV), 1 mV (±1999 mV) |
| Temperature Resolution | 0.1°C / 0.1°F |
| Accuracy (pH) | ±0.01 pH @ 20°C |
| Accuracy (ORP) | ±0.2 mV (±699.9 mV), ±1 mV (±1999 mV) |
| Accuracy (Temperature) | ±0.4°C / ±0.8°F (excluding probe error) |
| Calibration | Auto-recognized 2-point with 7 built-in NIST/USA traceable buffer points (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0°C) |
| Input Impedance | 10¹² Ω |
| Electrode Interface | BNC |
Show next