| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | ChemSCAN & ChemSCAN Custom |
| Operating Pressure | 200 bar |
| Operating Temperature | −60 °C to 200 °C |
| Catalyst Bed Volume | 120 mL |
| Reactor Configuration | 8 independently controlled parallel reactors |
| Standard Vessel Capacity | 16 mL |
| Optional Vessel Capacities | 25 mL, 50 mL, 75 mL, 120 mL, 160 mL, 300 mL, 400 mL |
| Stirring Options | Magnetic suspension stirring, overhead mechanical stirring (optional), stir-controlled per reactor |
| Gas Consumption Monitoring | Real-time, reactor-specific calculation |
| Liquid Dosing | Optional automated high-pressure liquid injection |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CAT 7 / CAT 18 / CAT 24 |
| Max. Operating Pressure | 100 bar |
| Max. Operating Temperature | 300 °C |
| Catalyst Bed Volume | 10 mL |
| Vessel Material | 316 Stainless Steel or Hastelloy® Alloy |
| Sample Capacity Options | 2–10 mL per vessel |
| Heating Method | External (hotplate, oil bath, or PolyBlock™ heater block) |
| Stirring | Magnetic stirring integrated |
| Temperature Monitoring | Integrated micro thermocouple |
| Cooling Option | Finger-type condenser (CAT 7 & CAT 24 only) |
| HPLC Vial Compatibility | 2 mL vials (CAT 18 only) |
| Purge & Pressurization | Manual valve-controlled inert gas purge and reactant gas pressurization (e.g., H₂) |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | DigiCAT 96 |
| Max. Reaction Pressure | 100 bar |
| Max. Reaction Temperature | 200 °C |
| Catalyst Loading Volume | 1 mL per vial |
| Throughput | 96 parallel reactors |
| Heating Block Material | Aluminum |
| Stirring | Synchronized magnetic stirring per vial |
| Safety Valve Setpoint | ~35 bar (standard configuration) |
| Dimensions (W×D×H) | 350 × 300 × 400 mm |
| Pressure Vessel Dimensions | 125 × 85 × 60 mm |
| Control Interface | PC-connected software with real-time monitoring and automated sequence programming |
| Actuation | Solenoid feed & vent valves |
| Temperature Control | PID-regulated, sensor-integrated aluminum heating block |
| Compliance | Designed to meet CE marking requirements for laboratory pressure equipment (PED 2014/68/EU applicable to < 200 bar systems under Category I) |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | FlowCAT & FlowCAT Custom |
| Operating Pressure | 200 bar |
| Operating Temperature | 550 °C |
| Catalyst Bed Volume | 30 mL |
| Reactor Materials | 316 Stainless Steel or Hastelloy |
| Standard Reactor Internal Diameter | 6 mm (¼") or 12 mm (½") |
| Active Heating Zone Length | 10 cm |
| Liquid Feed Rate Range | 0.001–10 mL/min or 0.01–50 mL/min |
| Gas Feed Control | Mass Flow Controllers (e.g., H₂) |
| Flow Modes | Trickle-Bed, Bubble-Column, Fixed-Bed Continuous Flow |
| Optional Configurations | Single or Parallel Reactor Systems |
| Compliance | Designed for GLP/GMP-aligned operation with audit-trail-capable software |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | DigiCAT |
| Reaction Pressure | 100 bar (max. 200 bar) |
| Reaction Temperature | 200 °C (max. 300 °C) |
| Catalyst Bed Volume | 75 mL |
| Compatible Reactor Formats | CAT-7, CAT-18, CAT-24, and custom vessels (16–75 mL) |
| Control Interface | PC-based software with integrated electromagnetic inlet/outlet valves, real-time T&P monitoring, safety relief valve setpoint: ~35 bar |
| Heating Method | Bottom-mounted aluminum heating block with PID temperature control |
| Stirring Mechanism | Internal magnetic stirrer drive coupled to external motor via high-strength permanent magnet array |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | PolyCAT 4, PolyCAT 8 |
| Maximum Operating Pressure | 200 bar |
| Maximum Operating Temperature | 550 °C |
| Catalyst Bed Volume | 30 mL |
| Reactor Volume | 16 mL (standard) |
| Temperature Control Range | 25–250 °C (inter-reactor ΔT ≤ 100 °C) |
| Liquid Feed Rate | 0.001–10 mL/min or 0.01–50 mL/min |
| Gas Feed | Mass-flow controlled (e.g., H₂), continuously adjustable |
| Configuration Options | 4-channel parallel or 8-channel parallel |