Add to compare
BrandH.E.L
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPhi-TEC II
Price RangeUSD 135,000–270,000 (FOB UK)
Instrument TypeAccelerating Rate Calorimeter (ARC)
Measurement ModeAdiabatic Calorimetry
Temperature Range−80 °C to 500 °C
Temperature Resolution0.001 K
Temperature Accuracy (Direct Sample Mode)±0.001 °C
Temperature Tracking RateUp to 400 °C/min (Low-Φ mode)
Standard50 °C/min
Pressure Range0–300 bar (optional up to 1000 bar)
Pressure Tracking Rate0–200 bar/min (optional 700 bar/min)
Pressure Accuracy±0.05% FS
Pressure Resolution0.01 bar
Heat Release Detection Sensitivity0.002–0.2 °C/min
Sample Mass Capacity0.5–80 g
Adiabatic Correction Factor (Φ)≤1.05 (optimized for Phi-TEC II)
Outer & Inner Dewar Volume60 mL each
Thermal Capacity60,000 J
Single-Test DurationUp to 1000 min
StirringElectromagnetic, 0–500 rpm (mechanical option available)
Operating ModesHWS (Heat-Wait-Search), RAMP, ISO (Isothermal)
Dimensions30 cm × 37 cm × 50 cm
Power Supply220 V AC, 13 A, single-phase
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
ModelPhi-TEC I
Instrument TypeAdiabatic Accelerating Calorimeter
Measurement ModeAdiabatic Calorimetry
Temperature Range−60 °C to 500 °C
Temperature Resolution0.005 K
Temperature Accuracy (direct sample mode)±0.01 °C
Temperature Stability (isothermal mode)±0.001 °C
Heat Capacity~10,000 J/K
Sample Mass Range0.5–80 g
Pressure Range0–300 bar (optional up to 1000 bar)
Pressure Accuracy±0.05% FS
Pressure Resolution0.01 bar
Exothermic Detection Sensitivity0.005–0.2 °C/min
φ-factor (low-φ cell)≤1.05
StirringElectromagnetic, 0–500 rpm (mechanical stirrer optional)
Operating ModesHWS (Heat-Wait-Search), RAMP, ISO
External/Inner Dewar Volume10 mL each
Single-Sample Test Duration~600 min
Dimensions30 cm × 37 cm × 50 cm
Power Supply220 V AC, 13 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUnited Kingdom
ModelisoBTC-500
Temperature Range−60 °C to 100 °C
Temperature Resolution0.001 °C
Temperature Precision±0.01 °C
Single-Sample Test Durationup to 1000 min
Heat Capacity10,000 J/K
Outer Bath Volume1000 mL
Inner Bath Volume1000 mL
Instrument TypeAccelerating Calorimeter
Measurement ModeIsothermal Calorimetry
ComplianceDesigned for GLP/GMP-aligned battery thermal safety testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
ModelTSu
Instrument TypeAccelerating Rate Calorimeter (ARC®-style)
Measurement ModeAdiabatic Calorimetry
Temperature Range–60 °C to 500 °C
Temperature Resolution0.01 °C
Temperature Precision±0.01 °C
Single-Sample Test Duration~600 min
Heat Capacity~10,000 J/K
Outer Dewar Volume~10 mL
Inner Dewar Volume~10 mL
Sample Mass Range0.5–5 g
Pressure Range (standard)0–200 bar
Sample Cell8 mL spherical vessel (material options: borosilicate glass, stainless steel, Hastelloy®, custom alloys)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelSimular 10L/20L
Calorimetry ModeAdiabatic
Instrument TypeReaction Calorimeter
AutomationFully Automated
Temperature Range−30 °C to 225 °C
Temperature Resolution0.2 mK
Temperature Precision±0.1 K
Maximum Jacket Pressure100 bar
Heat Capacity Range±750 J/K
Vessel MaterialsBorosilicate Glass, 316 Stainless Steel, Hastelloy C-276
Compatible PAT InterfacesFTIR, Raman, pH, DO, ORP, Turbidity, Pressure, Temperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
Modeliso-BTC+
Measurement ModeIsothermal Calorimetry
Instrument TypeAccelerating Rate Calorimeter (ARC-compatible architecture)
Temperature Range−60 °C to +100 °C
Temperature Resolution0.001 °C
Temperature Precision±0.01 °C
Single-Sample Test Durationup to 1000 min
Heat Capacity10,000 J/K
Outer Bath Volume1000 mL
Inner Bath Volume1000 mL
Sample Chamber Dimensions350 × 350 mm (W × D)
Maximum Compensation Power200 W
Minimum Detectable Heat Flow5 mW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
ModelBTC-500
Instrument TypeAccelerating Rate Calorimeter (ARC)
Measurement ModeAdiabatic Calorimetry
Temperature Range−80 °C to 500 °C
Temperature Resolution0.001 K
Precision±0.01 K
Single-Sample Test DurationUp to 1000 min
Heat Capacity60,000 J
Outer Bath Volume1000 mL
Inner Bath Volume1000 mL
Adiabatic Control MethodReal-time Online PhiTEC Calibration
Sample Chamber DimensionsΦ50 × 50 cm (standard), Φ35 × 35 cm (optional)
Pressure RatingUp to 30 MPa
Data ChannelsExpandable to 8 or 16 independent temperature inputs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUK
ModelSIMULAR
Instrument TypeReaction Calorimeter
Measurement ModeIsothermal Calorimeter
Temperature Range−80 to 350 °C
Temperature Resolution0.001 K
Precision±0.1%
Single-Sample Test Duration300 min
Heat Capacity10,000 J
External Water Bath Volume1000 mL
Internal Water Bath Volume1000 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelHP Simular
Measurement ModeAdiabatic Calorimetry
Instrument TypeReaction Calorimeter
AutomationFully Automated
Temperature Range−30 °C to 210 °C
Temperature Resolution0.2 mK
Temperature Precision±0.1 K
Heat Capacity Range±750 J/K
Maximum Pressure100 bar (upgradable to 200 bar)
Vessel Volume Options0.5 L, 1 L, 2 L
Vessel Materials316 Stainless Steel or Hastelloy C-276
Stirring SystemPTFE-coated shaft with 4-blade PTFE impeller (45–60° pitch)
Pressure ReliefSwagelok 316SS PRV + dial pressure gauge
Integrated SensorsTemperature, pressure, optional in situ FTIR/Raman/turbidity/particle size
Calibration Heater150 W power-compensation heater
Control SoftwareHEL ChemScan™ with PAT integration, audit trail, and 21 CFR Part 11 compliance support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
ModelPAC-02
Measurement ModeAdiabatic Calorimetry
Instrument TypeAccelerating Rate Calorimeter (ARC)
Temperature Range20–350 °C
Temperature Resolution0.1 °C/min
Precision≤0.1 °C
Sample Chamber Volume2015 mL
Automation LevelFully Automated
OriginFujian, China
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
ModelBTC-130
Measurement ModeAdiabatic Calorimetry
Instrument TypeAccelerating Rate Calorimeter (ARC)
Temperature Range25–500 °C
Temperature Resolution0.001 K
Precision±0.01 K
Single-Sample Test Durationup to 1000 min
Heat Capacity60,000 J
Outer Bath Volume1000 mL
Inner Bath Volume1000 mL
Sample Chamber Diameter130 mm
Sample Chamber Height200 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L (UK)
OriginUnited Kingdom
ModelH.E.L Dual Simular Ambient/High-Pressure Dual-Reactor Calorimetry System
Instrument TypeReaction Calorimeter
Measurement ModesIsothermal Power Compensation Calorimetry, Isothermal Heat-Flow Calorimetry, Isoperibolic Reflux Calorimetry, Dynamic Ramp Calorimetry
Temperature Range−30 °C to 225 °C
Maximum Pressure Rating100 Pa (vacuum to 100 Pa absolute)
Reactor Volumes0.5 L, 1 L, 2 L
MaterialsBorosilicate Glass, 316 Stainless Steel, Hastelloy C-276
Calibration Heater150 W
Automation LevelFully Automated with Integrated Feedback Control
Sensor IntegrationpH, Turbidity, In-situ FTIR, Raman, Particle Size Probes, Mass Flow Controllers (MFCs), Precision Load Cells
Software ComplianceSupports ALCOA+ principles, audit trail, electronic signatures (21 CFR Part 11–ready configuration available)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (Hazard Evaluation Laboratories)
OriginUK
ModelPhiTEC II
Measurement ModeAdiabatic Calorimetry
Instrument TypeReaction Calorimeter
FunctionMicro-scale
Temperature Range0–500 °C
Temperature Detection Threshold0.02 °C/min
Adiabatic Temperature Tracking Rate200 °C/min
Maximum Calorimetric Chamber Pressure Rating137 bar