- All
- Favorite
- Popular
- Most rated
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phi-TEC II |
| Price Range | USD 135,000–270,000 (FOB UK) |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Temperature Accuracy (Direct Sample Mode) | ±0.001 °C |
| Temperature Tracking Rate | Up to 400 °C/min (Low-Φ mode) |
| Standard | 50 °C/min |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Tracking Rate | 0–200 bar/min (optional 700 bar/min) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Heat Release Detection Sensitivity | 0.002–0.2 °C/min |
| Sample Mass Capacity | 0.5–80 g |
| Adiabatic Correction Factor (Φ) | ≤1.05 (optimized for Phi-TEC II) |
| Outer & Inner Dewar Volume | 60 mL each |
| Thermal Capacity | 60,000 J |
| Single-Test Duration | Up to 1000 min |
| Stirring | Electromagnetic, 0–500 rpm (mechanical option available) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO (Isothermal) |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A, single-phase |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | Phi-TEC I |
| Instrument Type | Adiabatic Accelerating Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −60 °C to 500 °C |
| Temperature Resolution | 0.005 K |
| Temperature Accuracy (direct sample mode) | ±0.01 °C |
| Temperature Stability (isothermal mode) | ±0.001 °C |
| Heat Capacity | ~10,000 J/K |
| Sample Mass Range | 0.5–80 g |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Exothermic Detection Sensitivity | 0.005–0.2 °C/min |
| φ-factor (low-φ cell) | ≤1.05 |
| Stirring | Electromagnetic, 0–500 rpm (mechanical stirrer optional) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO |
| External/Inner Dewar Volume | 10 mL each |
| Single-Sample Test Duration | ~600 min |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | isoBTC-500 |
| Temperature Range | −60 °C to 100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 10,000 J/K |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Instrument Type | Accelerating Calorimeter |
| Measurement Mode | Isothermal Calorimetry |
| Compliance | Designed for GLP/GMP-aligned battery thermal safety testing |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | TSu |
| Instrument Type | Accelerating Rate Calorimeter (ARC®-style) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | –60 °C to 500 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | ~600 min |
| Heat Capacity | ~10,000 J/K |
| Outer Dewar Volume | ~10 mL |
| Inner Dewar Volume | ~10 mL |
| Sample Mass Range | 0.5–5 g |
| Pressure Range (standard) | 0–200 bar |
| Sample Cell | 8 mL spherical vessel (material options: borosilicate glass, stainless steel, Hastelloy®, custom alloys) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | Simular 10L/20L |
| Calorimetry Mode | Adiabatic |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 225 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Maximum Jacket Pressure | 100 bar |
| Heat Capacity Range | ±750 J/K |
| Vessel Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Compatible PAT Interfaces | FTIR, Raman, pH, DO, ORP, Turbidity, Pressure, Temperature |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | iso-BTC+ |
| Measurement Mode | Isothermal Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC-compatible architecture) |
| Temperature Range | −60 °C to +100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 10,000 J/K |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Sample Chamber Dimensions | 350 × 350 mm (W × D) |
| Maximum Compensation Power | 200 W |
| Minimum Detectable Heat Flow | 5 mW |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-500 |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.01 K |
| Single-Sample Test Duration | Up to 1000 min |
| Heat Capacity | 60,000 J |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Adiabatic Control Method | Real-time Online PhiTEC Calibration |
| Sample Chamber Dimensions | Φ50 × 50 cm (standard), Φ35 × 35 cm (optional) |
| Pressure Rating | Up to 30 MPa |
| Data Channels | Expandable to 8 or 16 independent temperature inputs |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CrystalEYES |
| Temperature Range | −40 °C to 200 °C |
| Detection Principle | Near-Infrared (NIR) Laser Turbidity Sensing |
| pH Monitoring | Integrated Auto-Logging |
| Data Output | CSV/Excel-Compatible Export |
| Software | Real-Time Graphical Acquisition & MSZW Analysis Module |
| Compliance | Designed for GLP/GMP-Aligned Process Development Environments |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | SIMULAR |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal Calorimeter |
| Temperature Range | −80 to 350 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.1% |
| Single-Sample Test Duration | 300 min |
| Heat Capacity | 10,000 J |
| External Water Bath Volume | 1000 mL |
| Internal Water Bath Volume | 1000 mL |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | HP Simular |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 210 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Heat Capacity Range | ±750 J/K |
| Maximum Pressure | 100 bar (upgradable to 200 bar) |
| Vessel Volume Options | 0.5 L, 1 L, 2 L |
| Vessel Materials | 316 Stainless Steel or Hastelloy C-276 |
| Stirring System | PTFE-coated shaft with 4-blade PTFE impeller (45–60° pitch) |
| Pressure Relief | Swagelok 316SS PRV + dial pressure gauge |
| Integrated Sensors | Temperature, pressure, optional in situ FTIR/Raman/turbidity/particle size |
| Calibration Heater | 150 W power-compensation heater |
| Control Software | HEL ChemScan™ with PAT integration, audit trail, and 21 CFR Part 11 compliance support |
| Brand | H.E.L |
|---|---|
| Model | PAC-02 |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | 20–350 °C |
| Temperature Resolution | 0.1 °C/min |
| Precision | ≤0.1 °C |
| Sample Chamber Volume | 2015 mL |
| Automation Level | Fully Automated |
| Origin | Fujian, China |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-130 |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | 25–500 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.01 K |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 60,000 J |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Sample Chamber Diameter | 130 mm |
| Sample Chamber Height | 200 mm |
| Brand | H.E.L (UK) |
|---|---|
| Origin | United Kingdom |
| Model | H.E.L Dual Simular Ambient/High-Pressure Dual-Reactor Calorimetry System |
| Instrument Type | Reaction Calorimeter |
| Measurement Modes | Isothermal Power Compensation Calorimetry, Isothermal Heat-Flow Calorimetry, Isoperibolic Reflux Calorimetry, Dynamic Ramp Calorimetry |
| Temperature Range | −30 °C to 225 °C |
| Maximum Pressure Rating | 100 Pa (vacuum to 100 Pa absolute) |
| Reactor Volumes | 0.5 L, 1 L, 2 L |
| Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Calibration Heater | 150 W |
| Automation Level | Fully Automated with Integrated Feedback Control |
| Sensor Integration | pH, Turbidity, In-situ FTIR, Raman, Particle Size Probes, Mass Flow Controllers (MFCs), Precision Load Cells |
| Software Compliance | Supports ALCOA+ principles, audit trail, electronic signatures (21 CFR Part 11–ready configuration available) |
| Brand | HEL (Hazard Evaluation Laboratories) |
|---|---|
| Origin | UK |
| Model | PhiTEC II |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Function | Micro-scale |
| Temperature Range | 0–500 °C |
| Temperature Detection Threshold | 0.02 °C/min |
| Adiabatic Temperature Tracking Rate | 200 °C/min |
| Maximum Calorimetric Chamber Pressure Rating | 137 bar |
Show next