| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PT-01 |
| Measurement Range | 0–99,999 folds |
| Folding Angle | 0°–142° continuously adjustable |
| Folding Speed | 10–200 folds/min, stepless adjustment |
| Spring Tension | 4.91–14.72 N (9.81 N preload compresses spring ≥17 mm) |
| Tension Stability | Imported tension assembly |
| Tension Variation Due to Eccentric Rotation | ≤0.343 N |
| Folding Jaw Width | 19 ±1 mm |
| Crease Radius | 0.38 ±0.02 mm |
| Specimen Length | ≥140 mm |
| Temperature Drift at Crease | ≤1 °C after 4 h |
| Jaw Spacing | 9.5 mm |
| Lower Jaw Clamping | Knurled cylindrical knob for ergonomic, high-grip clamping |
| Crease Gap Options | 0.25 / 0.5 / 0.75 / 1.00 mm (user-selectable) |
| HMI | 5-inch LCD display with real-time data visualization |
| Output | Integrated thermal printer module |
| Operating Environment | 0–35 °C, RH <85% |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PT-02 |
| Compliance | GB/T 451.3 |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | PTT-03A |
| Measurement Range | 0–2 mm (standard), optional 0–6 mm / 0–12 mm |
| Resolution | 0.1 µm (1 µm optional) |
| Test Speed | 1–25 tests/min |
| Measuring Head Parallelism | ±0.2 µm (mechanically adjustable, verified with gauge blocks) |
| Accuracy | ±<0.3 µm |
| Contact Pressure | 17.5 ± 1 kPa (for films), 50 ± 1 kPa (for paper), customizable for other materials |
| Contact Geometry | Spherical probe |
| Power Supply | AC 220 V, 50 Hz / AC 120 V, 60 Hz |
| Dimensions (L×W×H) | 300 × 400 × 435 mm |
| Net Weight | ~30 kg |
| Compliance Standards | GB/T 6672, GB/T 451.3, GB/T 6547, ASTM D645, ASTM D374, ASTM D1777, TAPPI T411, ISO 4593, ISO 534, ISO 3034, DIN 53105, DIN 53353, JIS K6250, JIS K6328, JIS K6783, JIS Z1702, BS 3983, BS 4817, ASTM D6988, ASTM F2251, BS 2782-6, DIN 53370, ISO 9073-2, ISO 12625-3, ISO 5084, ASTM D3652, GB/T 24218.2, FEFCO No. 3, EN 1942 |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SCT-A6 |
| Test Stations | 6 |
| Pressure Range | 0.1–0.7 MPa |
| Test Duration | 1.0–999999.9 s |
| Touchscreen | 7-inch capacitive HMI |
| Air Supply Requirement | 0.7–0.8 MPa (user-provided) |
| Air Interface | Φ8 mm polyurethane tubing |
| Dimensions (L×W×H) | 660 × 200 × 372 mm |
| Standard Accessories | Main unit, 8 pcs tempered glass plates, 1 air hose, 1 power cord |
| Brand | Paratronix |
|---|---|
| Model | WVTR-C6 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Principle | Gravimetric Cup Method (Weight Change over Time) |
| Measurement Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 6 independent stations |
| Resolution | 0.0001 g |
| Accuracy | ±0.01 g/m²·24h |
| Temperature Control Range | 15–55°C (standard) |
| Temp. Stability | ±0.1°C |
| Humidity Control Range | 10–90% RH (standard 90% RH) |
| RH Stability | ±1% RH |
| Airflow Velocity | 0.5–2.5 m/s (customizable) |
| Max. Sample Thickness | ≤3 mm (customizable) |
| Test Area | 33 cm² |
| Sample Diameter | Φ74 mm |
| Test Modes | Desiccant Method (Standard), Moisture Gain Method (Optional), Dual-Mode (Optional) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 660 × 480 × 525 mm |
| Net Weight | 70 kg |
| Gas Supply Pressure | 0.6 MPa |
| Tubing Interface | Φ6 mm polyurethane tube |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | WVTR-C6 |
| Price | USD 9,500 (FOB) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | PARNet |
| Pricing | Available Upon Request |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | ABS |
| Power Supply | 100–230 V AC, 750 VA |
| Operating Temperature | 15–35 °C |
| Operating Humidity | 20–80 % RH (non-condensing) |
| Weight | 34 kg |
| Dimensions | Not specified |
| Compressed Air Requirement | ASTM D5001-compliant (≤0.1 ppm hydrocarbons), dry and oil-free |
| Deionized Water Reservoir Capacity | ~1000 tests per fill |
| Control | Microprocessor-based, fully automated |
| Environmental Compliance | Designed for ISO/IEC 17025-aligned laboratories |
| Software Interface | PC-based control and data logging with audit-trail capability |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | EHD2 |
| Pricing | Upon Request |
| Product Type | Laboratory Instrument |
| Test Parameters | Oil Film Thickness (1–1000 nm), Traction Coefficient (Friction Coefficient) |
| Load Range | 0–50 N |
| Contact Pressure Range | 0–0.7 GPa (Steel Ball–Glass Disk) / 0–3 GPa (WC Ball–Sapphire Disk) |
| Sliding/Rolling Ratio | 0–100% |
| Linear Speed | 0–4 m/s |
| Temperature Range | Ambient to 150 °C |
| Sample Volume | 120 mL |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | HFRR |
| Frequency Range | 10–200 Hz |
| Stroke Range | 20 µm–2.0 mm |
| Load Capacity | 0–1.0 kg (via calibrated weights) |
| Maximum Friction Force | up to 10.0 N (amplitude-dependent) |
| Operating Temperature | ambient to 150 °C (up to 400 °C with optional high-power heating module) |
| Standard Counterface | 10.0 mm diameter × 3.0 mm thick steel disc |
| Standard Indenter | 6.0 mm diameter hardened steel ball |
| Compliance | ASTM D6079, ASTM D7688, ISO 12156-1, SH/T 0765–2021 |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ETM |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 100–1650 N |
| Maximum Contact Pressure | 3.5 GPa (standard steel test specimens) |
| Sliding Velocity | up to 3.5 m/s |
| Temperature Range | 10–150 °C |
| Sample Volume | 30 mL (10 mL with optional filler insert) |
| Operating System | Windows 10 |
| Safety Features | Dual PT100 RTD temperature monitoring, emergency stop button, interlocked lubricant reservoir lid |
| Power Supply | 100–240 V, 50/60 Hz, 1600 VA |
| Weight (main unit) | 52 kg |
| Dimensions (H × W × D) | 425 mm × 400 mm × 605 mm |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MPR |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Load Range | 0–2000 N |
| Contact Pressure | 0–3.2 GPa |
| Sliding/Rolling Ratio | 0–200% |
| Temperature Range | Ambient to 150 °C |
| Specimen Volume | 150 mL |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | MTM2 |
| Product Type | Laboratory Instrument |
| Test Parameter | Friction and Wear |
| Sample Volume | 10–35 mL |
| Load Range | 0–75 N |
| Contact Pressure Range | 0–1.25 GPa (standard test geometry) |
| Sliding/Rolling Velocity | −4 to +4 m·s⁻¹ |
| Temperature Range | Ambient to 150 °C (sub-ambient operation supported via external refrigerated oil bath) |
| Power Supply | 100–240 V AC, 50/60 Hz, 750 VA |
| Host Weight | 30 kg |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-380 |
| Detection Range | 0–50 mg SO₂ |
| Detection Limit | ≤100 g solid or ≤100 mL liquid (sample-dependent) |
| SO₂ Recovery Rate | >99.5% |
| Repeatability (RSD) | ≤0.5% |
| Distillation Time | Programmable, 0–99 min per sample |
| Distillation Speed | 3–8 min/sample |
| Heating Power | Adjustable, 750–1500 W |
| Sample Processing Mode | Automatic & Manual dual mode |
| Memory Capacity | 100 programmable methods (acid volume, absorbent volume, distillation time) |
| Safety Features | Real-time liquid-level monitoring (acid, absorbent, condensate), dry-run protection for digestion cup (Peiou patented), automatic alarm & state-resume function |
| Optional | N₂ purge interface (specify at order) |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | F1-25 |
| Application | Educational Hydraulics & Turbomachinery Laboratory Equipment |
| Enclosure | Cast Housing with Transparent Observation Panel |
| Torque Measurement | Spring-Balanced Mechanical Dynamometer |
| Pressure Indication | Remote Bourdon-Tube or Digital Pressure Gauge |
| Speed Measurement | Optional Non-Contact Tachometer (100–2000 rpm range) |
| Load Control | Calibrated Weights for Pelton Injector Needle Actuation |
| Software Option | Armfield Educational Software Suite (Data Logging, Real-Time Plotting, Efficiency Calculation) |
| Brand | Harold |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | LI-II |
| Pricing | Available Upon Request |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | PaddyCheck™ PC 6800 |
| Compliance | AACCI Method No. 61-10.01 |
| Power | Rechargeable battery (3 h analysis / 8 h standby) |
| Dimensions | Compact, portable design |
| Sensor Suite | Polarized light sensor, visible-light RGB sensor, precision force sensor (17 N max load) |
| Brand | Perkone |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PF-E |
| Price Range | USD 7,000 – 14,000 |
| Mixing Bowl Capacity | 300 g |
| Torque Range | 0–1000 FU |
| Torque Accuracy | ≤0.5% of full scale |
| Torque Measurement | Electronic transducer |
| Main Mixer Blade Speed | 63 rpm |
| Auxiliary Mixer Blade Speed | 94.5 rpm |
| Mixing Bowl & Blades | German-sourced hardened stainless steel (corrosion- and wear-resistant, >10-year service life) |
| Dropper Tip Material | PTFE |
| Interchangeable Mixing Heads | Yes |
| Includes | Farinograph主机, thermal printer, water supply unit, thermostatic water bath (±0.2°C stability), dual calibrated burettes, proprietary farinogram analysis software |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Persee GMP Data Integrity Compliance Solution |
| Pricing | Available Upon Request |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | doughLAB |
| Price Range | USD 68,000 – 109,000 |
| Torque Measurement Range | 0–25 N·m |
| Rotational Speed Range | 0 or 10–200 rpm |
| Temperature Control Range | 10–80 °C (standard), with ±0.2 °C stability at 30 °C |
| Water Dispensing Range | 1–300 mL |
| Sample Bowl Options | 50 g or 300 g |
| Dimensions (H×W×D) | 970 × 490 × 370 mm |
| Weight | 91 kg (with bowl), 70 kg (without bowl) |
| Ambient Operating Conditions | 5–40 °C, <80% RH at 31 °C |
| Data Interface | RS-232 to USB converter |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | FN1000 |
| Compliance | ASTM/ICC/AACC/ISO/GB Standards |
| Sample Type | Wheat, Durum, Rye, Barley, Flour, and Other Cereal Grains |
| Measurement Principle | Viscosity-based enzymatic hydrolysis kinetics (Hagberg-Perten method) |
| Temperature Control | Precise 100 °C water bath with auto-leveling system |
| Dispensing Accuracy | 25.0 ± 0.2 mL deionized water per test |
| Display | 5.7″ color touchscreen with multilingual UI (including Chinese) |
| Connectivity | USB 2.0 + Ethernet (RJ45) for LIMS integration, barcode readers, and thermal printers |
| Altitude Compensation | Automatic correction above 610 m (2000 ft) ASL |
| Dual-Mode Operation | Standard Falling Number (FN) and Fungal Falling Number (FFN) via firmware switch |
| Data Management | Sample ID registration, moisture-corrected reporting, audit-ready result logs |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | GM2000 |
| Gluten Washing Time | 5 min |
| Mixer Speed | 120 ± 5 rpm |
| Dough Mixing Time | 20 s |
| Compliance | AACC 38-12.02, ICC 155/158/137/1, ISO 21415-2 & -4, GB/T 5506.2 & 5506.4, IRAM 15864, CCAT Method 13 |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LactoScope 300™ FT-IR |
| Detection Scope | Raw milk (cow, goat, sheep, camel), cream, whey, pasteurized milk, formulated milk, dairy beverages |
| Automation Level | Semi-automatic |
| Throughput | 60–80 samples/hour |
| Repeatability | ≤1.2% CV |
| Accuracy | ≤0.5% CV |
| Operating System | Windows 10 |
| Software Interface | Fully localized Chinese GUI with stepwise workflow navigation |
| Calibration Modules | Pre-configured, ready-to-use calibration packs for raw milk, cream, whey, pasteurized milk, goat milk, sheep milk |
| Data Storage | SQL-based database architecture with backup/restore capability and external storage support |
| Protein Range | 0–15% w/w |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FT-IR) with patented Dynascan™ interferometer |
| Brand | Perten |
|---|---|
| Origin | Netherlands |
| Model | LactoScope FT-A |
| Automation Level | Semi-automatic |
| Analysis Speed | 100–120 samples/hour |
| Measurement Range | Fat: 0–55% |
| Protein | 0–25% (including 0–15% for protein-specific quantification) |
| Lactose | 0–22% |
| Total Solids | 0–60% |
| Repeatability | ≤ 0.25% CV |
| Accuracy | < 1% CV |
| Operating System | Windows-based |
| Interface Language | English (localized UI available) |
| Calibration Kits | Pre-validated, ready-to-use modules for raw milk, cream, whey, flavored milk, and yogurt |
| Data Storage | SQL database architecture with backup, restore, and external storage support |
| Optical Technology | Mid-infrared (MIR) Fourier Transform Infrared Spectroscopy |
| Measurement Time | 30–45 seconds per sample |
| Interferometer | Patented Dynascan™ technology |
| Environmental Protection | OpticsGuard™ desiccation system with molecular sieve |
| Brand | Perten |
|---|---|
| Origin | Netherlands |
| Model | LactoScope FT-B |
| Automation Level | Semi-Automatic |
| Analysis Speed | 60–80 samples/hour |
| Detection Range | Fat: 0–40% |
| Protein | 0–15% |
| Lactose | 0–15% |
| Total Solids | 0–45% |
| Repeatability | ≤0.25% CV |
| Accuracy | <1% CV |
| Operating System | Windows-based GUI with localized Chinese interface |
| Calibration Kits | Pre-validated modules for raw milk, cream (up to 40% fat), whey, flavored milk, and yogurt |
| Data Storage | SQL database architecture with backup/recovery support and external storage compatibility |
| Optical System | Dynascan™ interferometer-based FTIR with OpticsGuard™ desiccation and molecular sieve protection |
| Compliance | ISO 9622 / IDF 141, AOAC 972.16, ICAR-certified |
| Sample Volume | 10 mL |
| Sample Temperature Range | 4–42 °C |
| Dimensions (W×D×H) | 49 × 70 × 49 cm |
| Weight | 86 kg |
| Power Supply | 100–120 V, 60 Hz or 220–240 V, 50 Hz |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Model | RVA 4500 |
| Viscosity Range | 20–50,000 cP (at 80 rpm) |
| Measurement Time | 3 min (stirring value) |
| Sample Mass | 2–3 g |
| Compliance | GB/T 22427.7-2023, GB/T 24852-2010, GB/T 24853-2010, AACC 61-02 (1995), AACC 22-08 (1995), AACC 76-21 (1997) |
| Software | Thermocline for Windows (TCW3) |
| Drive System | Brushless DC motor |
| Temperature Control | Programmable ramping and holding (4–130 °C) |
| Shear Control | Variable rotational speed (up to 160 rpm) |
| Data Output | Time-temperature-viscosity profiles with automated parameter extraction (onset, peak, breakdown, setback, final viscosity) |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Model | RVA 4800 |
| Temperature Range | Up to 140 °C |
| Viscosity Range | 20–50,000 cP (at 80 rpm) |
| Sample Mass | 2–3 g |
| Test Duration | 3 min (stirring value), 13 min (standard starch gelatinization) |
| Compliance | GB/T 22427.7–2023, GB/T 24852–2010, GB/T 24853–2010, AACC 61-02, AACC 22-08, AACC 76-21 |
| Software | TCW3 with 67 pre-validated methods |
| Interface | PC-connected via USB/RS-232 |
| Brand | Perten |
|---|---|
| Origin | Imported (Sweden) |
| Model | RVA-TecMaster |
| Viscosity Range | 40–16,000 cP at 80 rpm |
| Sample Mass | 2–3 g |
| Measurement Time | 3 min (stirring value), 13 min (paste viscosity profile) |
| Compliance | GB/T 22427.7-2023, GB/T 24852-2010, GB/T 24853-2010, AACC 61-02 (1995), AACC 22-08 (1995), AACC 76-21 (1997) |
| Software | Thermocline for Windows (TCW3), supports method upload and offline operation |
| Brand | Perten |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RVA4800 |
| Voltage | 230/115 VAC, 5 A, 50/60 Hz |
| Dimensions (H×W×D) | 382 × 306 × 345 mm |
| Net Weight | 19 kg |
| Temperature Range | 0–140 °C |
| Heating/Cooling Rate | Up to 14 °C/min (adjustable) |
| Cooling Requirement | Tap water or recirculating chiller (1 L/min, 100–250 kPa) |
| Speed Range | 0, 20–2000 rpm (software-controlled) |
| Viscosity Range | 20–50,000 cP (at 80 rpm) |
| Viscosity Accuracy | ±2% at 5000 cP (calibrated against S2000 standard oil) |
| Compliance | ISO 9000 / ISO/IEC 17025, GB/T 22427.7–2023, ICC, AACC, FDA 21 CFR Part 11 (ER/ES), GLP/GMP-ready audit trail in TCW3 software |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PGC5007B |
| Pricing | Available Upon Request |