Empowering Scientific Discovery

Jiangsu Keyuan Electronic Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelKY-4S
PriceUpon Request
Standard ComplianceGB/T 1792–1988
Sample FormLiquid
Measurement Range≥3 µg/g
Titration MethodPotentiometric Titration
Minimum Dispensed Volume0.01 mL
Potential Measurement Range±1999.5 mV
Burette Accuracy±0.1% F·S
Electronic Unit Basic Error±0.1% of full scale + 0.5 mV
Relative Error≤5%
Control PlatformWindows-based PC Interface
Electrode InputDual High-Impedance Input
Endpoint DetectionAutomatic Potential Inflection Point Recognition
Fluid HandlingAutomated Reagent Refill and Fixed-Volume Dispensing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelKY-4
PricingUpon Request
Measurement PrincipleMicrocoulometric Titration
Sample FormLiquid
Method StandardSH/T 0630-1996, SH/T 1551-2018, GB/T 11136-1989(2004), SH/T 1767-2008(2015), GB/T 1815-1997, ASTM D1492
Bromine Number Range0–300 g Br/100 g sample
Bromine Index Range1–1000 mg Br/100 g sample
Accuracy±3% ±0.2 g Br (bromine number)
Detection Limit1 mg Br
Resolution0.01 mg Br
Bias Voltage Range0–500 mV
Dimensions280 × 280 × 160 mm
Power Consumption150 W
InterfaceUSB
ElectrolyteBenzene-free
Sample Volume<10 mL (typical)
Analysis Time~60 seconds per sample
Endpoint DetectionPotentiometric
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-4 D
PricingAvailable Upon Request
Standard ComplianceGB/T 1792–1988
Sample FormLiquid
Measurement Range≥3 µg/g
Titration MethodPotentiometric Titration
Minimum Titration Volume0.01 mL
Potential Measurement Range–1999.5 to +1999.5 mV
Burette Accuracy±0.1% F·S
Electrode Potential Resolution0.1 mV
Basic Error of Potential Unit±0.5 mV or ±0.1% of full scale
Relative Standard Deviation (RSD)≤5%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-200 CL
PricingAvailable Upon Request
Measurement PrincipleMicrocoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4 Compliant)
Analyte RangeS: 0.1–10,000 mg/L
Cl0.2–10,000 mg/L
Detection LimitS: 0.1 mg/L
Cl0.2 mg/L
RepeatabilityCV ≤3% (S >10 mg/L), ±0.1 mg/L (0.5–1.0 mg/L S), CV ≤8% (1–10 mg/L S)
Temperature ControlAmbient to 1100 °C (±1 °C)
Power Consumption1500 W
Gas RequirementsIndustrial-grade N₂ and O₂
Sample FormsLiquid, Solid, Gas (with optional dedicated injectors)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelKY-214A
PriceUpon Request
Sulfur Range0.01–60 wt%
Resolution0.01 wt%
Max Sample Capacity24 positions
Avg. Analysis Time~5 min per sample
Furnace Ramp Time15–25 min (from ambient to setpoint)
Temperature Range700–1300 °C (user-selectable)
Temp. Control Accuracy±2.5 °C
Sample Mass Range10–999.9 mg
Automatic Powder Dispensing300 cycles per reagent box
Power Supply220 V ±20 V, 50 Hz
Max Instantaneous Power (Furnace)≤3.5 kW
Repeatability (St ≤1.5%)<0.05 wt%
Reproducibility (St ≤1.5%)<0.10 wt%
ComplianceFully conforms to GB/T 214–2007 for total sulfur determination in coal by coulometric titration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan Instruments
OriginJiangsu, China
Manufacturer TypeManufacturer
Regional ClassificationDomestic (China)
ModelKY-200
PricingUpon Request
PrincipleMicrocoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Detection RangeS: 0.1–10,000 mg/L
Cl0.1–10,000 mg/L
LOD0.1 mg/L (S and Cl)
RepeatabilityCV ≤3% for [S] >10 mg/L
Temperature ControlAmbient to 1100 °C, ±1 °C
Carrier GasesIndustrial-grade N₂ and O₂
CoolingFan-cooled pyrolysis furnace (auto-start/stop)
ComplianceASTM D5808, SH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, GB/T 18612
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-210A
PriceUpon Request
Measurement RangeCl: 0.2–10,000 mg/L
Detection Limit0.1 mg/L
Repeatability≤15% (x ≤ 0.5 mg/L), ≤10% (0.5 < x ≤ 1.0 mg/L), ≤8% (1.0 < x ≤ 10 mg/L), ≤3% (x > 10 mg/L)
Electrolytic Cell Stability>8 h
Temperature Control RangeAmbient to 1100 °C
Temperature Control Accuracy±1 °C
Analysis Time1 min per sample
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelKY-200
PricingAvailable Upon Request
Measurement PrincipleMicrocoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4)
Analyte FormsTotal Sulfur (as SO₂), Total Chlorine (as HCl)
Sample TypesLiquid, Solid, Gas (with optional injectors)
Detection Range0.1–10,000 mg/L for both S and Cl
LOD0.1 mg/L (S and Cl)
RepeatabilityCV ≤ 3% (x > 10 mg/L)
Temperature ControlAmbient to 1100 °C, ±1 °C accuracy
Carrier GasesIndustrial-grade N₂ and O₂
CoolingIntelligent Fan-based Air Cooling
Power Requirement1500 W
Compliance StandardsSH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, GB/T 18612, ASTM D5808
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0