Empowering Scientific Discovery

Jiangsu Keyuan Electronic Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-3000SA
Detection PrincipleUV Fluorescence
PortabilityBenchtop (Non-portable)
AnalyteTotal Sulfur
Measurement Range0.2 mg/L to 5000 ppm to % (w/w)
Analysis Time<10 min
Detection Limit0.2 mg/L
Accuracy±0.1 mg/L for 0.2 mg/L ≤ X < 1.0 mg/L
RepeatabilityCV ≤10% (1.0–100 mg/L), CV ≤5% (100–10,000 mg/L)
Temperature Control RangeAmbient to 1300 °C
Temperature Stability±3 °C
Power Consumption2 kW
Gas RequirementsHigh-purity O₂ (≥99.98%), High-purity Ar (≥99.98%)
Data Acquisition24-bit ADC, USB Interface
PMT VoltageAdjustable
Calibration ModesSingle-point or multi-point calibration
Compliance StandardsSH/T 0689, ASTM D5453, GB/T 34100–2017
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelKY-200
Price RangeUSD 4,200 – 7,000 (FOB)
Analyte ScopeTotal Sulfur, Total Nitrogen, and Halides (Cl⁻, Br⁻, I⁻)
Measurement PrincipleMicrocoulometric Titration per ASTM D5808 & GB/T 18612
Detection Range (Cl)0.05–10,000 mg/L
LOD (Cl)0.05 mg/L
Repeatability≤10% (≤1 mg/L), ≤8% (1–10 mg/L), ≤3% (>10 mg/L)
Sensitivity0.05 mg NaCl/L
Furnace Temp ControlAmbient to 1000 °C ±1 °C
Cooling MethodIntelligent Fan-Cooled
Analysis Time~3 min/sample (excluding sample prep)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelKY-3000SN
Price RangeUSD 14,000–42,500 (FOB China)
Analyte CoverageTotal Sulfur (S) and Total Nitrogen (N)
Detection PrincipleUV Fluorescence (S), Chemiluminescence (N)
Compliance StandardsSH/T 0689, ASTM D5453, GB/T 34100-2017, SH/T 0657, ASTM D4629
Sample FormsLiquid, Solid, Gas (with optional dedicated injectors)
S Detection Range0.2 mg/L to 100% w/w
N Detection Range0.1 mg/L to 100% w/w
S LOD0.2 mg/L
N LOD0.1 mg/L
Combustion Furnace TempAmbient to 1300 °C
Temp Control Accuracy±1 °C
Data Acquisition24-bit ADC, USB Interface, Minimum Detectable Signal < 1 µV
PMT High VoltageAdjustable
Calibration ModesSingle-point or multi-point
RepeatabilityCV ≤ 10% (1–100 mg/L), CV ≤ 5% (100–10000 mg/L)
Carrier/Reactant GasesArgon ≥99.98%, Oxygen ≥99.98%
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz
Rated Power1500 W
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
ModelKY-3000S
Price RangeUSD 7,000–14,000 (FOB China)
AnalyteTotal Sulfur
Detection PrincipleUV Fluorescence (ASTM D5453 / SH/T 0689 / GB/T 34100-2017)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Detection Range0.2 mg/L to 5000 ppm (up to % level)
LOD0.2 mg/L (as S)
Repeatability≤±0.1 mg/L (0.2–1.0 mg/L)
Furnace Temp ControlRT–1300 °C, ±3 °C
Gas Requirements≥99.98% O₂ and ≥99.98% Ar
Data Acquisition24-bit USB interface, signal resolution <1 µV
PMT HV AdjustmentContinuously variable
CalibrationSingle- or multi-point standard curve
Software CompatibilityWindows 10/11, macOS (via Wine), Linux (via VM)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoyuan
OriginJiangsu, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelKY-200 Microcoulometric Sulfur Analyzer
Price RangeUSD 4,200 – 7,000 (FOB)
AnalyteTotal Sulfur
Measurement PrincipleMicrocoulometric Titration (ASTM D3229 / SH/T 0253-92 / GB/T 11061-1997 / SH/T 0222-1992)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Detection Range0.2–10,000 mg/L S
LOD0.2 mg/L S
Repeatability±0.1 mg/L (0.5–1.0 mg/L)
Furnace Temp ControlAmbient to 1100 °C, ±1 °C
Carrier GasesTechnical-grade O₂ and N₂
CoolingAir-cooled裂解 furnace with auto-start/stop fan
Power Requirement1500 W
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelKY-4D
Price RangeUSD 4,200–7,000
Detection PrinciplePotentiometric Titration
PortabilityBenchtop (Non-portable)
AnalyteAlkaline Nitrogen in Petroleum Products
Measurement Range≥3 µg/g
Analysis Time<10 min
Detection Limit±0.1% F.S.
Indication Error0.1% F.S. ± 0.5 mV
Titration Resolution0.01 mL
Electrode Potential Range0 to ±1999.5 mV
Burette Accuracy±0.1% F.S.
Electronic Unit Basic Error0.1% of full scale ± 0.5 mV
Relative Error≤5%
Compliance StandardSH/T 0162–1992
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-3000S
Price RangeUSD 7,000–14,000 (FOB)
AnalyteTotal Sulfur
Sample TypesLiquid, Solid, Gas (with optional injectors)
Detection PrincipleUltraviolet Fluorescence (UVF)
Measurement Range0.2–5000 mg/L (as S), extendable to wt%
LOD0.2 mg/L (as S)
Furnace Temperature RangeAmbient to 1100 °C
Temp Control Accuracy±0.5% or ±3 °C, whichever is greater
High Voltage SupplyDC 700–900 V (software-adjustable, default ~650 V)
Carrier GasesArgon ≥99.98%, Oxygen ≥99.98%
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz, ≤2 kW
Dimensions680 × 480 × 400 mm
Compliance StandardsSH/T 0689, ASTM D5453
Data Acquisition24-bit USB interface, minimum detectable signal <1 µV
PMT HV AdjustmentFully software-controlled, single- or multi-point calibration supported
Software CompatibilityWindows 10/11, Linux (via Wine), macOS (virtualized)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-3000X
Detection PrincipleEnergy-Dispersive X-Ray Fluorescence (EDXRF)
PortabilityBenchtop (Non-Portable)
AnalyteTotal Sulfur
Measurement Range7 mg/kg – 500,000 mg/kg (0.0007% – 50% w/w)
Analysis Time5 s – 1000 s (user-selectable increments)
Limit of Detection (LOD)7 mg/kg
Accuracy±3 mg/kg at 20 mg/kg
Sample Volume2–4 mL
Calibration CurvesUp to 999 user-defined calibration curves
InterfaceUSB 2.0
Operating Environment5–40 °C, ≤85% RH (at 30 °C), 220 V ±20 V, 50 Hz
Dimensions (L×W×H)400 × 300 × 230 mm
Weight9.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyuyuan Instruments
OriginJiangsu, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelKY-3000NS
Detection PrincipleUV Fluorescence (S), Chemiluminescence (N)
PortabilityBenchtop (Non-portable)
Analyte TypesTotal Sulfur and Total Nitrogen
Measurement Range0.1–100,000 mg/L
Analysis Time<10 min
LOD0.1 mg/L (N), 0.2 mg/L (S)
Accuracy±0.2 mg/L (at ≤1.0 mg/L)
RepeatabilityCV ≤10% (1–100 mg/L), CV ≤5% (100–10,000 mg/L)
Furnace Temperature RangeAmbient to 1300 °C
Temperature Control Precision±1 °C
Power SupplyAC 220 V ±10%, 50 Hz, 1500 W
Gas RequirementsArgon ≥99.98%, Oxygen ≥99.98%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-200S
Detection TargetTotal Sulfur
Measurement PrincipleMicrocoulometric Titration (ASTM D3227, SH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Sulfur Range0.1 mg/L to 10,000 mg/L
Detection Limit0.1 mg/L (as S)
Repeatability≤30% RSD (x < 0.5 mg/L)
Temperature Control RangeAmbient to 1100 °C
Temperature Stability±1 °C
Power Requirement1500 W
Carrier GasesIndustrial-grade N₂ and O₂
Cooling MethodIntelligent Fan-based Air Cooling
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelKY-202
Price RangeUSD 4,200 – 7,000 (FOB China)
AnalyteTotal Sulfur
Measurement PrincipleMicrocoulometric Titration (ASTM D3227, SH/T 0222–1992, GB/T 11061–1997, SH/T 0253–1992)
Sample TypesLiquid & Gaseous Hydrocarbons (with optional gas/liquid autosamplers)
Detection Range0.2–10,000 mg/L S
LOD0.2 mg/L S
Repeatability≤30% RSD (at ≤1.0 mg/L), ≤10% RSD (1.0–100 mg/L), ≤5% RSD (>100 mg/L)
Furnace Temp ControlAmbient to 1100 °C, ±1 °C
Carrier GasesIndustrial-grade O₂ and N₂
CoolingFan-cooled裂解炉 (Auto-start/stop)
Power1500 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-200
Detection TargetTotal Sulfur
Measurement PrincipleMicrocoulometric Titration (ASTM D3227, SH/T 0253, GB/T 11061.4, SH/T 0222)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Detection Range0.2–10,000 mg/L S
LOD0.2 mg/L S
PrecisionCV ≤ 3% (for x > 10 mg/L S)
Temperature ControlAmbient to 1100 °C, ±1 °C
Power Requirement1500 W
Carrier GasesIndustrial-grade N₂ and O₂
Cooling MethodIntelligent Fan-based Air Cooling
Compliance StandardsSH/T 0253, GB/T 11061.4, SH/T 0222
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelKY-202
Price RangeUSD 4,200 – 7,000 (FOB)
AnalyteTotal Sulfur
PrincipleMicrocoulometric Titration (ASTM D3227, SH/T 0253, GB/T 11061.4, SH/T 0222)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Detection Range0.2 mg/L – 10,000 mg/L (S)
LOD0.2 mg/L (S)
RepeatabilityAs per SH/T 0253 specifications (Cv ≤ 3% for [S] > 10 mg/L
Temperature ControlAmbient to 1100 °C, ±1 °C
Power1500 W
Carrier GasesTechnical-grade O₂ and N₂
CoolingAir-cooled pyrolysis furnace with auto-controlled fan
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelOIL-6
Detection TargetsTotal Nitrogen and Total Sulfur
Detection PrincipleInfrared Spectrophotometry (FTIR-compatible Dispersive Optical System)
Compliance StandardHJ 637–2012 (China National Standard for Determination of Petroleum Hydrocarbons and Animal/Vegetable Oils in Water by Infrared Spectrophotometry)
Measurement Range0.01–10,000 mg/L (water samples, via CCl₄ extraction with variable pathlength cells)
Detection Limit<0.15 mg/L (CCl₄ extract, 4 cm quartz cell)
<0.002 mg/L (water sample, 1001 extraction ratio, 5 cm quartz cell)
Repeatability≤1% (at 20 mg/L oil standard)
LinearityR > 0.999
Wavenumber Range2400–3400 cm⁻¹
Absorbance Range0.0000–3.000 AU
Dimensions550 × 380 × 150 mm
Weight15 kg
Power Supply220 ± 22 V, 50 ± 1 Hz, 35 VA
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0