Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelKY-210B
Instrument TypeUniversal Potentiometric Titrator
Application ScopeGeneral-purpose
Bias Voltage Range0–500 mV (adjustable)
Chloride Ion Measurement Range0.1 ppm to full percentage content
Accuracy< ±2%
Repeatability≤ ±0.1 mg NaCl/L (for samples ≤2 mg NaCl/L)
Detection SensitivityCl⁻: 0.1 mg/L
Titration Cell Volume145 mL
Sample Mass0.02–0.05 g
Dimensions (W×D×H)465 × 280 × 195 mm
Power Consumption40 W
Operating Environment10–40 °C, RH ≤80%, low electromagnetic interference
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelKY-4
Instrument TypeBasic Nitrogen & Mercaptan Sulfur Analyzer
Application ScopeDedicated Analyzer
Sample FormLiquid
Measurement Range≥3 µg/g
Titration MethodPotentiometric Titration
Minimum Titration Volume0.01 mL
Potential Measurement Range0 to ±1999.5 mV
Burette Accuracy±0.1% F·S
Electronic Unit Basic Error±0.1% of full scale + 0.5 mV
AccuracyRelative error ≤5%
Compliance StandardSH/T 0162
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelKY-200
PricingAvailable Upon Request
PrincipleMicrocoulometric Titration (ASTM D3227, ASTM D5808, SH/T 0253–1992, GB/T 11061–1997, SH/T 0222–1992)
Sample TypesLiquid, Solid, Gas (with optional injectors)
Detection MethodCoulometric Generation of Titrant (I₂ for S
Sulfur Range0.2–10,000 mg/L
Chlorine Range0.3–10,000 mg/L
Bias Voltage Range0–500 mV
Furnace Temperature RangeAmbient to 1000 °C
Temperature Control Accuracy±5 °C
Power Consumption1500 W
Dimensions (W×D×H)530 × 500 × 340 mm
CoolingAir-cooled Cracking System with Auto-Controlled Fan
ComplianceSH/T 0253–1992, GB/T 11061–1997, SH/T 0222–1992
Standard ConfigurationKY-200 Liquid Analysis System + PC Workstation
Optional AccessoriesSolid Sampler, Light/Heavy Quartz Cracking Tubes, Certified Reference Materials
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeUniversal Potentiometric Titrator
ModelKY-4Br
Measurement PrincipleCoulometric Titration (Microcoulometry)
Measurement RangeBromine Number: 0–300 g Br/100g oil
Bromine Index1–1000 mg Br/100g oil
Detection Limit1 mg Br
Accuracy±3% ±0.2 g Br (bromine number)
Resolution0.01 mg Br
Bias Voltage Range0–500 mV
Sample Volume<10 µL (bromine number)
Reagent Consumption<1 mL per sample
Power Consumption20 W
Compliance StandardsSH/T 0630–1996, SH/T 1551–2018, GB/T 11136–1989(2004), SH/T 1767–2008(2015), GB/T 1815–1997, ASTM D1492
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelKY4S
PricingAvailable Upon Request
Sample TypeLiquid
MethodPotentiometric Titration
Detection Limit≥3 µg/g
Minimum Burette Delivery Volume0.01 mL
Potential Measurement Range0 to ±1999.5 mV
Burette Accuracy±0.1% F.S.
Electronic Unit Basic Error±0.1% of full scale + 0.5 mV
Relative Error≤5%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelKY-200.1
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-200
Price RangeUSD 2,800 – 7,000
Measurement PrincipleMicrocoulometric Titration (Electrolytic Iodine Generation)
Sample FormsLiquid, Solid, Gas (with optional injectors)
AnalyteTotal Sulfur (S)
Detection Range0.1 mg/L – 10,000 mg/L
LOD (S)0.1 mg/L
RepeatabilityAs per SH/T 0253 (Cv ≤ 3% at >10 mg/L
Temperature ControlAmbient to 1100 °C, ±1 °C
Carrier GasesIndustrial-grade N₂ and O₂
Cooling MethodIntelligent Fan-based Air Cooling
Power Rating1500 W
Compliance StandardsSH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, SH/T 1147
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeOEM Manufacturer
Region of OriginDomestic (China)
ModelKY-6
Instrument CategoryAutomatic Potentiometric Titrator
Application ScopeUniversal
Measurement Range≥0.001 mg KOH/g
Potentiometric Measurement Range−2000.0 to +2000.0 mV
Electronic Unit Basic Error±0.1% F·S ± 0.1 mV
Input Impedance≥1 × 10¹² Ω
Burette Capacity10 mL
Minimum Dispensing Volume0.001 mL
Burette Accuracy±0.1% F·S
Titration Accuracy±0.1% F·S
Endpoint DetectionAdaptive endpoint recognition via smoothed titration curve analysis
Compliance StandardsGB/T 7304–2000, GB/T 18609–2010
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelKY-4D
Instrument TypeAlkaline Nitrogen & Mercaptan Sulfur Analyzer
Application ScopeGeneral-purpose petroleum product analysis
Measurement Range≥3 µg/g
Burette Resolution0.01 mL
Potentiometric Accuracy±0.1% F.S.
Potential Measurement Range(0 to ±1999.5) mV
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeUniversal Potentiometric Titrator
Application ScopeDedicated for Hydrocarbon Analysis
Bromine Number Range0–300 g Br/100 g oil
Bromine Index Range1–1000 mg Br/100 g oil
Potential Measurement Accuracy0.1 mV ± 0.03%
Potential Resolution0.1 mV
Titration Volume Precision0.001 mL
Bromine Mass Resolution0.01 mg Br
Detection Limit0.1 mg Br
Accuracy±5% (bromine index ≥ 1 mg Br/100 g oil)
Bias Voltage Range0–500 mV
Cell Volume150 mL
Stirring MethodMagnetic Stirring
Power Supply220 V, 50 Hz
Power Consumption20 W
Weight~1.6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelKY-200
PricingUpon Request
Standard ComplianceSH/T 0253–92, GB/T 11061–1997, SH/T 0222–1992
Sample TypesLiquid, Solid, Gas (with optional injectors)
Analytical MethodMicrocoulometric Titration
Bias Voltage Range0–500 mV
Measurement RangeS: 0.2–10,000 mg/L
Cl0.3–10,000 mg/L
Repeatability≤50% RSD for S ≤1.0 mg/L
Carrier GasesAmbient-grade O₂ and N₂
Furnace Temperature RangeAmbient to 1000 °C
Temperature Control Accuracy±5 °C
Power Consumption1500 W
Dimensions (W×D×H)530 × 500 × 340 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelWC-200
Detection MethodCoulometric Titration (Electrolytic Silver Generation)
Measurement Range1 ppm – 1 wt% Cl
Detection Limit1 ppm
Precision≤1 ppm (for 1–10 ppm Cl)
Sample TypesSolid, Liquid, or Viscous Petroleum Samples (with compatible autosampler or quartz boat system)
Temperature Control RangeAmbient to 1100 °C
Temperature Stability±1 °C
Gas RequirementsIndustrial-grade O₂ and N₂
Cooling SystemIntelligent Fan-based Air Cooling
Compliance StandardRIPP 64-90 (Refined Petroleum Products — Determination of Total Chlorine Content by Microcoulometry)
Power Rating1.5 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelKY-200CL
Price RangeUSD 2,800 – 7,000
Measurement PrincipleMicrocoulometric Titration (Silver Coulometric Detection)
Sample FormsSolid, Liquid, Gas (with optional injectors)
Chlorine Range0.2 mg/L – 10,000 mg/L (dilution required above 5,000 mg/L)
Detection Limit0.2 mg/L (as Cl)
PrecisionRSD ≤3% for [Cl] >10 mg/L
Temperature ControlAmbient to 1100 °C, ±1 °C
Power Requirement1500 W
Carrier GasesIndustrial-grade N₂ and O₂
Cooling MethodIntelligent Fan-cooled Cracking System
Compliance StandardsGB/T 18612–2011, ASTM D5808–2009
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-200
PriceUpon Request
PrincipleMicrocoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Detection RangeS: 0.1–10,000 mg/L
Cl0.2–10,000 mg/L
Detection LimitS: 0.1 mg/L
Cl0.2 mg/L
RepeatabilityAs per ASTM/SH/GB standards (Cv ≤3% at >10 mg/L)
Temperature ControlAmbient to 1100 °C, ±1 °C
Power Requirement1500 W
Carrier GasesIndustrial-grade N₂ and O₂
CoolingFan-cooled pyrolysis furnace with auto-start/stop logic