Empowering Scientific Discovery

Jiangsu Keyuan Electronic Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelKY-200
PricingAvailable Upon Request
PrincipleMicrocoulometric Titration (ASTM D3227, ASTM D5808, SH/T 0253–1992, GB/T 11061–1997, SH/T 0222–1992)
Sample TypesLiquid, Solid, Gas (with optional injectors)
Detection MethodCoulometric Generation of Titrant (I₂ for S
Sulfur Range0.2–10,000 mg/L
Chlorine Range0.3–10,000 mg/L
Bias Voltage Range0–500 mV
Furnace Temperature RangeAmbient to 1000 °C
Temperature Control Accuracy±5 °C
Power Consumption1500 W
Dimensions (W×D×H)530 × 500 × 340 mm
CoolingAir-cooled Cracking System with Auto-Controlled Fan
ComplianceSH/T 0253–1992, GB/T 11061–1997, SH/T 0222–1992
Standard ConfigurationKY-200 Liquid Analysis System + PC Workstation
Optional AccessoriesSolid Sampler, Light/Heavy Quartz Cracking Tubes, Certified Reference Materials
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-200
Price RangeUSD 2,800 – 7,000
Measurement PrincipleMicrocoulometric Titration (Electrolytic Iodine Generation)
Sample FormsLiquid, Solid, Gas (with optional injectors)
AnalyteTotal Sulfur (S)
Detection Range0.1 mg/L – 10,000 mg/L
LOD (S)0.1 mg/L
RepeatabilityAs per SH/T 0253 (Cv ≤ 3% at >10 mg/L
Temperature ControlAmbient to 1100 °C, ±1 °C
Carrier GasesIndustrial-grade N₂ and O₂
Cooling MethodIntelligent Fan-based Air Cooling
Power Rating1500 W
Compliance StandardsSH/T 0253, GB/T 11061.4, SH/T 0222, GB/T 3208, SH/T 1147
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelKY-200
PricingUpon Request
Standard ComplianceSH/T 0253–92, GB/T 11061–1997, SH/T 0222–1992
Sample TypesLiquid, Solid, Gas (with optional injectors)
Analytical MethodMicrocoulometric Titration
Bias Voltage Range0–500 mV
Measurement RangeS: 0.2–10,000 mg/L
Cl0.3–10,000 mg/L
Repeatability≤50% RSD for S ≤1.0 mg/L
Carrier GasesAmbient-grade O₂ and N₂
Furnace Temperature RangeAmbient to 1000 °C
Temperature Control Accuracy±5 °C
Power Consumption1500 W
Dimensions (W×D×H)530 × 500 × 340 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelWC-200
Detection MethodCoulometric Titration (Electrolytic Silver Generation)
Measurement Range1 ppm – 1 wt% Cl
Detection Limit1 ppm
Precision≤1 ppm (for 1–10 ppm Cl)
Sample TypesSolid, Liquid, or Viscous Petroleum Samples (with compatible autosampler or quartz boat system)
Temperature Control RangeAmbient to 1100 °C
Temperature Stability±1 °C
Gas RequirementsIndustrial-grade O₂ and N₂
Cooling SystemIntelligent Fan-based Air Cooling
Compliance StandardRIPP 64-90 (Refined Petroleum Products — Determination of Total Chlorine Content by Microcoulometry)
Power Rating1.5 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelKY-200CL
Price RangeUSD 2,800 – 7,000
Measurement PrincipleMicrocoulometric Titration (Silver Coulometric Detection)
Sample FormsSolid, Liquid, Gas (with optional injectors)
Chlorine Range0.2 mg/L – 10,000 mg/L (dilution required above 5,000 mg/L)
Detection Limit0.2 mg/L (as Cl)
PrecisionRSD ≤3% for [Cl] >10 mg/L
Temperature ControlAmbient to 1100 °C, ±1 °C
Power Requirement1500 W
Carrier GasesIndustrial-grade N₂ and O₂
Cooling MethodIntelligent Fan-cooled Cracking System
Compliance StandardsGB/T 18612–2011, ASTM D5808–2009
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-200
PriceUpon Request
PrincipleMicrocoulometric Titration (ASTM D5808 / SH/T 0253 / GB/T 11061.4)
Sample FormsLiquid, Solid, Gas (with optional injectors)
Detection RangeS: 0.1–10,000 mg/L
Cl0.2–10,000 mg/L
Detection LimitS: 0.1 mg/L
Cl0.2 mg/L
RepeatabilityAs per ASTM/SH/GB standards (Cv ≤3% at >10 mg/L)
Temperature ControlAmbient to 1100 °C, ±1 °C
Power Requirement1500 W
Carrier GasesIndustrial-grade N₂ and O₂
CoolingFan-cooled pyrolysis furnace with auto-start/stop logic
Show next