Empowering Scientific Discovery

Jiangsu Keyuan Electronic Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
ModelKY-200AOX
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ComplianceHJ 1214–2021, GB/T 22904–2008
Temperature Range100–1150 °C
Temperature Control Accuracy±1 °C
Detection Range0.028–1000 mg/L (100 mL sample volume)
LOD0.007 mg/L as Cl⁻
Analysis Time3–10 min (excluding sample pretreatment)
Carrier GasO₂ ≥99.9%
Sample IntroductionModified quartz boat with direct liquid/solid injection capability
Sample Mass50 mg
Power Consumption1.5 kW
Electrical Supply220 V, 50 Hz
Net Weight~15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKYD-2003
Instrument TypeBenchtop Centrifuge
Speed CategoryLow-Speed Centrifuge (up to 10,000 rpm)
FunctionalityRefrigerated Centrifuge
ConfigurationFixed-Angle Rotor Centrifuge
Maximum Capacity6 × 85 mL
Maximum Rotational Speed30,000 rpm
Maximum RCFNot Specified
Dimensions (W×D×H)400 × 550 × 650 mm
Input VoltageAC 220 V ± 22 V
High-Voltage Output RangeAC 0–6,000 V (adjustable)
Power Consumption1,000 W
Temperature Control RangeAmbient to 180 °C
Temperature Accuracy±5 °C
Operating Environment0–40 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelKY-403
Measurement Range≥0.001 mg KOH/g
Potentiometric Range−2000.0 to +2000.0 mV
Basic Electrical Error±0.1% F.S. + 0.1 mV
Input Impedance≥1 × 10¹² Ω
Burette Capacity10 mL
Minimum Dispensing Volume0.001 mL
Burette Accuracy±0.1% F.S.
PrecisionCompliant with or Exceeding GB/T 18609 and GB/T 7304
Operating Temperature0–35 °C
Power SupplyAC 220 V ± 22 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelKY-4As
PricingAvailable Upon Request
Measurement PrincipleMicrocoulometric Titration
Sample TypeLiquid
Detection MethodHydride Generation–Microcoulometric Detection
Bias Voltage Range0–500 mV
Measurement Range1 × 10⁻⁹ % (1 ppb) to % level
Input Impedance≥10⁶ Ω
Output Voltage±24 V
Baseline Drift≤5 µV / 20 min
Temperature Control Accuracy±0.5% or ±5 °C (whichever is greater)
Analysis Time (instrumental only)5–10 min
Detection Limit1 ppb As
Operating Humidity<80% RH
Operating Temperature10–40 °C
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Region of OriginDomestic (China)
ModelKY-403
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelKY-210B
Instrument TypeUniversal Potentiometric Titrator
Application ScopeGeneral-purpose
Bias Voltage Range0–500 mV (adjustable)
Chloride Ion Measurement Range0.1 ppm to full percentage content
Accuracy< ±2%
Repeatability≤ ±0.1 mg NaCl/L (for samples ≤2 mg NaCl/L)
Detection SensitivityCl⁻: 0.1 mg/L
Titration Cell Volume145 mL
Sample Mass0.02–0.05 g
Dimensions (W×D×H)465 × 280 × 195 mm
Power Consumption40 W
Operating Environment10–40 °C, RH ≤80%, low electromagnetic interference
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-3000SA
Detection PrincipleUV Fluorescence
PortabilityBenchtop (Non-portable)
AnalyteTotal Sulfur
Measurement Range0.2 mg/L to 5000 ppm to % (w/w)
Analysis Time<10 min
Detection Limit0.2 mg/L
Accuracy±0.1 mg/L for 0.2 mg/L ≤ X < 1.0 mg/L
RepeatabilityCV ≤10% (1.0–100 mg/L), CV ≤5% (100–10,000 mg/L)
Temperature Control RangeAmbient to 1300 °C
Temperature Stability±3 °C
Power Consumption2 kW
Gas RequirementsHigh-purity O₂ (≥99.98%), High-purity Ar (≥99.98%)
Data Acquisition24-bit ADC, USB Interface
PMT VoltageAdjustable
Calibration ModesSingle-point or multi-point calibration
Compliance StandardsSH/T 0689, ASTM D5453, GB/T 34100–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelKY-4
Instrument TypeBasic Nitrogen & Mercaptan Sulfur Analyzer
Application ScopeDedicated Analyzer
Sample FormLiquid
Measurement Range≥3 µg/g
Titration MethodPotentiometric Titration
Minimum Titration Volume0.01 mL
Potential Measurement Range0 to ±1999.5 mV
Burette Accuracy±0.1% F·S
Electronic Unit Basic Error±0.1% of full scale + 0.5 mV
AccuracyRelative error ≤5%
Compliance StandardSH/T 0162
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelKY-4S
PricingUpon Request
Sample TypeLiquid
Analytical MethodPotentiometric Titration
Detection Limit≥3 µg/g
Minimum Titrant Dispense Volume0.01 mL
Potentiometric Range0 to ±1999.5 mV
Burette Accuracy±0.1% F.S.
Electronic Unit Basic Error±0.1% of full scale + 0.5 mV
Relative Standard Deviation≤5%
Compliance StandardGB/T 1792–1988 “Determination of Mercaptan Sulfur in Distillate Fuels”
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-0125
PriceUpon Request
Applicable StandardASTM D2420, SH/T 0125
Heating MethodElectric Tubular Heater
Temperature ControlDigital PID Controller with PT100 Sensor
Flow RegulationAdjustable Needle Valve with Flowmeter
Total Power1000 W
Power SupplyAC 220 V, 50 Hz
Detection Limit4 mg/m³ H₂S
Interference ProfileMethyl mercaptan causes transient yellow staining on lead acetate paper (<5 min fade)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelKY-4Wa
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
ModelKY-9000S
Measurement PrincipleUV Fluorescence (for Total Sulfur in Liquids)
Sample TypeLiquid
Sample Capacity19-position autosampler tray
Solvent Bottles2
Waste Bottle1
Injection Volume0.1–250 µL
Detection Range0.1–20,000 mg/L
LOD0.1 mg/L
Repeatability±0.2 mg/L at 1.0 mg/L
Furnace Temperature RangeAmbient to 1100 °C
Temperature Control Accuracy±2 °C
Gas RequirementsHigh-purity O₂ (≥99.99%) and Ar (≥99.99%)
Power Consumption1800 W
ComplianceASTM D5453, D6667, D7183
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelKY-403B
PricingAvailable Upon Request
Sample TypeLiquid
Sulfur Alcohol (Mercaptan Sulfur) Measurement Range0.0001–0.01 % (m/m)
Titration MethodPotentiometric Titration
Burette Capacity10 mL
Minimum Dispensed Volume0.01 mL
Potential Measurement Range±1999.5 mV
Burette Accuracy±0.1 % F.S.
Electronic Unit Basic Error±0.1 % of full scale + 0.5 mV
Relative Error≤5 %
Input Impedance≥1 × 10¹² Ω
ComplianceJJG 814–2015 Verification Regulation for Automatic Potentiometric Titrators
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
ModelKY-102
Measurement PrincipleInfrared Absorption (CO₂ & SO₂)
Carbon Range0.005–10.0000% (extendable to 99.999%)
Sulfur Range0.0005–0.3500% (extendable to 99.999%)
Analysis Time~35 s (excluding sample weighing)
Detection Limit200 ppm
Sample Mass100 mg – 1 g
Repeatability±200 ppm (200–1000 ppm)
Weighing Capacity0–100 g
Readability0.001 g
Required GasO₂ at 0.5 MPa, ≥99.7% purity
Combustion MethodsTube Furnace (for viscous samples), Arc Furnace (for solid samples)
Compliance StandardsGB/T 223.69–1997 (C), GB/T 223.68–1997 (S)
InterfaceWindows-based GUI with real-time curve display
Data AcquisitionPCI-bus integrated control and acquisition system
DetectorLow-noise, high-sensitivity, anti-interference infrared detector
Channel Configuration16 independent channels for carbon, 16 for sulfur (32 total, user-configurable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoyuan
OriginJiangsu, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelKY-3000
PriceUpon Request
Analysis Time1–999 s (recommended 60 s)
Detection Limit10 ppm
Sulfur Range0.001–9 wt% (petroleum matrix)
AccuracyCompliant with GB/T 17040, SH/T 0742–2004, ASTM D4294, and GB/T 11140
Operating Temperature5–40 °C
Relative Humidity≤85% at 30 °C
Power Supply220 V ±20 V, 50 Hz
Power Consumption<150 W
Dimensions (L×W×H)560 × 470 × 150 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeOEM Producer
Region ClassificationDomestic (China)
ModelKY-104C
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-3000S
Price RangeUSD 7,000 – 14,000
Detection PrincipleUltraviolet Fluorescence (UVF) for Total Sulfur
Compliance StandardsSH/T 0689, ASTM D5453, GB/T 34100-2017
Sample FormsLiquid, Solid, Gas (with optional injectors)
Detection Range0.2 mg/L to 5000 ppm (equivalent to 0.00002–0.5 wt%)
LOD0.2 mg/L (as S)
Repeatability±0.2 mg/L at 1.0 mg/L
Furnace Temp ControlAmbient to 1300 °C, ±1 °C stability
Carrier & Oxidant GasesHigh-purity O₂ (≥99.98%), high-purity Ar (≥99.98%)
Power Requirement2 kW
Data Acquisition24-bit ADC, USB 2.0 interface, minimum detectable signal <1 µV
PMT VoltageAdjustable, software-controlled
Calibration ModesSingle-point or multi-point linear/nonlinear curve fitting
Software CompatibilityWindows 7/10/11, macOS (via Wine-compatible runtime), Linux (CLI support)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelKY-200
PricingAvailable Upon Request
PrincipleMicrocoulometric Titration (ASTM D3227, ASTM D5808, SH/T 0253–1992, GB/T 11061–1997, SH/T 0222–1992)
Sample TypesLiquid, Solid, Gas (with optional injectors)
Detection MethodCoulometric Generation of Titrant (I₂ for S
Sulfur Range0.2–10,000 mg/L
Chlorine Range0.3–10,000 mg/L
Bias Voltage Range0–500 mV
Furnace Temperature RangeAmbient to 1000 °C
Temperature Control Accuracy±5 °C
Power Consumption1500 W
Dimensions (W×D×H)530 × 500 × 340 mm
CoolingAir-cooled Cracking System with Auto-Controlled Fan
ComplianceSH/T 0253–1992, GB/T 11061–1997, SH/T 0222–1992
Standard ConfigurationKY-200 Liquid Analysis System + PC Workstation
Optional AccessoriesSolid Sampler, Light/Heavy Quartz Cracking Tubes, Certified Reference Materials
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeUniversal Potentiometric Titrator
ModelKY-4Br
Measurement PrincipleCoulometric Titration (Microcoulometry)
Measurement RangeBromine Number: 0–300 g Br/100g oil
Bromine Index1–1000 mg Br/100g oil
Detection Limit1 mg Br
Accuracy±3% ±0.2 g Br (bromine number)
Resolution0.01 mg Br
Bias Voltage Range0–500 mV
Sample Volume<10 µL (bromine number)
Reagent Consumption<1 mL per sample
Power Consumption20 W
Compliance StandardsSH/T 0630–1996, SH/T 1551–2018, GB/T 11136–1989(2004), SH/T 1767–2008(2015), GB/T 1815–1997, ASTM D1492
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelKY-0231
PricingAvailable Upon Request
Applicable StandardSH/T 0231
Wet Gas Meter Capacity2 L
Stainless Steel Hollow Needleφ1 mm × 0.2 mm ID
H₂S Detection Range5–500 mg/m³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKeyuan Instruments
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelKY-100 (6-position)
Digestion MethodRapid Reflux Digestion
Heating ModulePrecision Ceramic Heating Block
Batch Capacity6 samples simultaneously
Temperature Range25–170 °C (adjustable, ±1 °C accuracy)
Digestion Vessel Capacity250 mL conical flasks with reflux condensers
Timer Accuracy±1 second over full 180-minute range
Power SupplyAC 220 V ±10%, 50 Hz
Rated Power1500 W
Ambient Operating Temperature5–40 °C
COD Measurement Range16–700 mg/L (dilutable for higher concentrations)
Analytical PrecisionRSD ≤5.0% for potassium hydrogen phthalate standard (500 mg/L)
ComplianceHJ 828–2017 (replacing GB 11914–1989), aligned with ISO 6060 principles
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelKY-4S
PricingAvailable Upon Request
Sample TypeLiquid
Analytical MethodPotentiometric Titration
Detection Limit≥3 µg/g
Minimum Titrant Dispense Volume0.01 mL
Electrode Potential Range0 to ±1999.5 mV
Burette Accuracy±0.1% F.S.
Electronic Unit Basic Error±0.1% of full scale + 0.5 mV
Relative Standard Deviation≤5%
Compliance StandardGB/T 1792–1988 “Determination of Mercaptan Sulfur in Distillate Fuels”
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelKY-200
Price RangeUSD 4,200 – 7,000 (FOB)
Analyte ScopeTotal Sulfur, Total Nitrogen, and Halides (Cl⁻, Br⁻, I⁻)
Measurement PrincipleMicrocoulometric Titration per ASTM D5808 & GB/T 18612
Detection Range (Cl)0.05–10,000 mg/L
LOD (Cl)0.05 mg/L
Repeatability≤10% (≤1 mg/L), ≤8% (1–10 mg/L), ≤3% (>10 mg/L)
Sensitivity0.05 mg NaCl/L
Furnace Temp ControlAmbient to 1000 °C ±1 °C
Cooling MethodIntelligent Fan-Cooled
Analysis Time~3 min/sample (excluding sample prep)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelKY4S
PricingAvailable Upon Request
Sample TypeLiquid
MethodPotentiometric Titration
Detection Limit≥3 µg/g
Minimum Burette Delivery Volume0.01 mL
Potential Measurement Range0 to ±1999.5 mV
Burette Accuracy±0.1% F.S.
Electronic Unit Basic Error±0.1% of full scale + 0.5 mV
Relative Error≤5%
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0