| Brand | Labthink |
|---|---|
| Model | EO Residual Detection System |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose EO residue quantification in sterilized medical devices |
| Oven Temperature Range | Ambient +3 °C to 399 °C |
| Oven Ramp Rate | 1–30 °C/min |
| Oven Cool-down Rate | ≤4 °C/min |
| Carrier Gas Flow Control Range | 0.1–5.0 mL/min (N₂ or He) |
| Carrier Gas Pressure Control Range | 0–200 psi |
| Injector Maximum Operating Temperature | 350 °C |
| Injector Pressure Setting Range | 0–200 psi |
| Injector Total Flow Setting Range | 1–50 mL/min |
| Brand | Labthink |
|---|---|
| Model | GC-7800 |
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Class | Benchtop Laboratory Gas Chromatograph |
| Detector Standard | Hydrogen Flame Ionization Detector (FID) |
| Temperature Control Precision | ±0.1 °C (RT+15 °C to 200 °C) |
| Column Oven Programmable Ramp | Up to 8 temperature steps |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 635 × 490 × 470 mm (L×W×H) |
| Weight | 55 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ERT-01 |
| Pricing | Available Upon Request |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-6890 |
| Temperature Control Range | Ambient + 3°C to 399°C |
| Heating Rate | 0.1–30°C/min |
| Cooling Rate | ≤15 min (from 300°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–10 mL/min |
| Carrier Gas Pressure Range & Control | 0–10 kPa |
| Injector Maximum Operating Temperature | 200°C |
| Injector Pressure Setting Range | 0–10 kPa |
| Injector Total Flow Setting Range | 0–10 mL/min |
| Brand | Labthink |
|---|---|
| Model | GC-6890 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +3 °C to 399 °C |
| Heating Rate | 1–30 °C/min |
| Cooling Rate | ≤15 min (from 300 °C to 50 °C) |
| Detector | Flame Ionization Detector (FID) |
| Column Oven Temperature Stability | ±0.1 °C |
| FID Detection Limit | ≤5×10⁻¹¹ g/s (benzene) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 490 × 490 × 480 mm (L×W×H) |
| Weight | 45 kg |
| Brand | Labthink |
|---|---|
| Model | GC-6890 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +10°C to 399°C |
| Column Oven Temperature Precision | Better than ±0.1°C |
| FID Detection Limit | ≤5×10⁻¹¹ g/s (benzene) |
| Noise | ≤1% of full-scale recorder |
| Drift | ≤3% of full-scale recorder per hour |
| Power Consumption | Max 2 kW |
| Dimensions (L×W×H) | 470×430×455 mm |
| Weight | 30 kg |
| Brand | Labthink |
|---|---|
| Model | GC-7800 |
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Oven Temperature Range | Ambient +3°C to 399°C |
| Temperature Ramp Rate | 1–30°C/min |
| Cooling Rate | ≤15 min from 300°C to 50°C |
| Oven Temperature Stability | ±0.1°C (typical) |
| Programmed Temperature Ramping | Up to 5 steps |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene with H₂ carrier) |
| Dimensions | 635 × 490 × 480 mm (L×W×H) |
| Weight | 55 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | GC-7800 |
| Price Range | USD 7,000–14,000 (FOB) |
| Temperature Control Range | Ambient +15 °C to 200 °C |
| Heating Rate | 1–30 °C/min |
| Maximum Column Oven Temperature | 399 °C |
| Temperature Stability | ±0.1 °C |
| Programmed Temperature Ramping | 5-step linear |
| Detector Options | FID (detection limit ≤1×10⁻¹¹ g/s for benzene), TCD (sensitivity ≥3000 mV·mL/mg for benzene in H₂ carrier) |
| Column Compatibility | Packed & capillary columns (including dedicated water-content analysis column and solvent residue separation column) |
| Data System | Integrated Windows-based chromatography workstation with ASTM/ISO-compliant reporting, GLP audit trail, and 21 CFR Part 11-ready user access control |
| Brand | Labthink |
|---|---|
| Model | GC-6890 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +3°C to 399°C |
| Oven Ramp Rate | 1–30°C/min |
| Cooling Rate | ≤15 min from 300°C to 50°C |
| Compliance | Designed for GB/T 14233.1–2008 and GB/T 16886.7–2001 EO residue testing protocols |