Add to compare
BrandLabthink
ModelC230H
OriginShandong, China
Manufacturer TypeOEM/ODM Producer
Country of OriginChina
Price RangeUSD 14,000 – 85,000
Test PrincipleIsobaric Method with Coulometric Oxygen Sensor
Standards ComplianceASTM D3985, ASTM F1307, ASTM F1927 (optional), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Range0.01–200 cm³/(m²·day) [film]
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C (±0.2 °C)
Humidity Control0–90% RH (±1% RH), 100% RH (optional)
Test Chambers3 independent chambers
Sample Area50 cm² (standard)
Max. Sample Size108 mm × 108 mm
Max. Thickness≤3 mm
Package Testing Capacityup to 3 L
Carrier Gas≥99.999% high-purity N₂
Inlet Pressure≥0.28 MPa (40.6 psi)
Gas Interface1/8″ stainless steel tubing
Optional FeaturesDataShield™ Data Integrity System, CFR 21 Part 11 Compliance Module, GMP Computer System Validation Support, Package Testing Mode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC230H
PrincipleCoulometric O₂ Sensor + Isobaric Method
Standard ComplianceASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354
Test ModesFilm, Sheet, Rigid/ Flexible Packaging (up to 3 L)
Chambers3 Independent Test Cells
OTR Range (Film)0.01–200 cm³/(m²·day)
OTR Range (Container)0.00005–1 cm³/(pkg·day)
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2% (whichever is greater)
Temperature Control10–55 °C (±0.2 °C)
Humidity Control0–90% RH (±1%)
Sample Area50 cm²
Max Sample Thickness≤3 mm
Sample Size108 mm × 108 mm
Carrier Gas≥99.999% N₂, ≥0.28 MPa
Data ManagementDataShield™ Audit-Trail Enabled
Regulatory SupportOptional 21 CFR Part 11 Compliance & GMP Computer System Validation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelC203H-Labthink
Price RangeUSD 28,000 – 98,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelC203H
Price RangeUSD 14,000 – 98,000
Test PrincipleIsostatic (Equal-Pressure) Method with Coulometric Oxygen Sensor
Standards ComplianceASTM D3985, ASTM F1307, ASTM F1927 (optional), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Area50 cm² (standard), 5 cm² / 1 cm² (optional), custom up to 400,000 cc/(m²·day)
Measurement Range0.01–200 cc/(m²·day) (50 cm²)
Resolution0.0001 cc/(m²·day)
Repeatability±0.01 cc/(m²·day) or ±1%, whichever is greater
Temperature Control Range15–50 °C (standard), 5–60 °C (custom)
Temp Stability±0.05 °C
RH Control Range0–90% RH (O₂ side: ±1%
carrier gas side±2%, optional)
Chamber ConfigurationTriple independent test cells
Sample Size11.2 cm × 11.2 cm (4.4″ × 4.4″)
Max Sample Thickness3 mm (120 mil)
Gas Requirements≥99.999% N₂ (carrier), ≥99.5% O₂ (permeant)
Power Supply120 VAC ±10% / 60 Hz OR 220 VAC ±10% / 50 Hz
Dimensions600 × 500 × 700 mm
Weight100 kg (220 lbs)
Key Sensorppb-level Coulometric O₂ sensor (3× service life vs. conventional)
AutomationFully automated sample clamping, drawer-style chamber actuation, real-time T/RH monitoring, closed-loop flow/temperature/humidity control
SoftwareEmbedded industrial PC, Windows-based 12″ touch HMI, CFR 21 Part 11 & GMP-compliant modules (optional), DataShield™ data integrity suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM/ODM Producer
Country of OriginChina
ModelC206H
Price RangeUSD 14,000 – 98,000
Test PrincipleIsobaric Method with Coulometric Oxygen Sensor
Standards ComplianceASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Area50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures
OTR Range0.02–200 cc/(m²·day) [50 cm²], up to 400,000 cc/(m²·day) (custom)
Resolution0.0001 cc/(m²·day)
Repeatability±0.02 cc/(m²·day) or ±1%, whichever is greater
Temperature Range15–50 °C (standard), 5–60 °C (optional)
Temp Stability±0.15 °C
Humidity Range0% RH, 5–90% RH ±2% RH
Chamber Count6 independent test cells
Sample Size11.2 cm × 11.2 cm (4.4" × 4.4")
Max Thickness3 mm (120 mil)
Gas Supply≥280 kPa (40.6 PSI) N₂ (99.999%), O₂ (99.5%)
Power120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz
Dimensions600 × 490 × 660 mm
Weight100 kg (220 lbs)
Control Interface12" Windows-based industrial touchscreen tablet
Data SecurityEmbedded industrial PC with CFR 21 Part 11-compliant audit trail option (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelC206H
Price RangeUSD 14,000 – 98,000
Test PrincipleIsobaric Coulometric Sensor Method (ASTM D3985 Compliant)
Test Range0.02–200 cc/(m²·day) @ 50 cm² (standard)
optional MASK areas5 cm² (0.2–2000 cc/(m²·day)) and 1 cm² (1–10,000 cc/(m²·day))
Resolution0.0001 cc/(m²·day)
Repeatability±0.02 cc/(m²·day) or ±1%, whichever is greater
Temperature Range15–50 °C (standard)
Temp. Stability±0.15 °C
Humidity Range0% RH, 5–90% RH ±2% RH
Test Chambers6 independent chambers
Chamber Area50 cm² (standard)
Sample Size11.2 cm × 11.2 cm
Max. Sample Thickness3 mm
Gas Supply≥99.999% N₂, ≥99.5% O₂ (user-supplied)
Inlet Pressure≥280 kPa (40.6 PSI)
Interface1/8" stainless steel tubing
Dimensions600 × 490 × 660 mm
Power120 VAC ±10% / 60 Hz OR 220 VAC ±10% / 50 Hz
Weight100 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelDV-Series (Modular Platform)
Price RangeUSD 14,000 – 70,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelC130H
Price RangeUSD 14,000 – 85,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelLabthink C230H OTR Tester
Price RangeUSD 14,000 – 85,000
Test PrincipleCoulometric Oxygen Sensor + Isobaric Method
Standards ComplianceASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Range0.01–200 cm³/(m²·day)
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C ±0.2 °C
Humidity Control0% RH, 5–90% RH ±1% RH, 100% RH
Test Chambers3 independent chambers
Sample Area50 cm² (standard)
Max. Sample Size108 mm × 108 mm
Max. Sample Thickness≤3 mm
Package Testing CapacityUp to 3 L (optional)
Carrier Gas≥99.999% high-purity N₂, inlet pressure ≥0.28 MPa (40.6 psi)
Interface1/8″ stainless steel tubing
Data ManagementDataShield™ audit-trail-enabled software with CFR 21 Part 11 support (optional)
Operating SystemWindows 10 on 12″ capacitive touchscreen
ConnectivityEthernet, Wi-Fi (optional), third-party API integration supported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC203H
Measurement PrincipleIsobaric Coulometric Sensor Method (ASTM D3985 compliant)
Test Area3 × 50 cm² independent chambers
OTR Range0.01–200 cc/(m²·day) (standard)
Resolution0.0001 cc/(m²·day)
Repeatability±0.01 cc/(m²·day) or ±1%, whichever is greater
Temperature Control15–50 °C (±0.05 °C stability)
RH Control0–90% RH (±1% for O₂ side
Sample Size11.2 cm × 11.2 cm
Max Thickness3 mm
Gas Requirements99.999% N₂ (carrier), 99.5% O₂ (permeant)
Power120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz
Dimensions600 × 500 × 700 mm
Weight100 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC230H
Measurement PrincipleCoulometric Sensor + Isobaric Method
Standards ComplianceASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015
Test Range0.01–200 cm³/(m²·day)
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C ±0.2 °C
Humidity Control0% RH, 5–90% RH ±1% RH, 100% RH
Test Chambers3 independent
Sample Area50 cm² (standard)
Max Sample Size108 mm × 108 mm
Max Sample Thickness≤3 mm
Package Testing Capacityup to 3 L (optional)
Carrier Gas≥99.999% high-purity N₂, inlet pressure ≥0.28 MPa
Data ManagementDataShield™ audit-trail-enabled software
Regulatory SupportOptional 21 CFR Part 11 compliance package
GMP/Computer System Validation SupportOptional
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelPERME博密 VAC-V2
Price RangeUSD 14,000 – 98,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelLabthink C230H
Price RangeUSD 14,000 – 85,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelVAC-V2
PrincipleDifferential Pressure Method
Test GasesO₂, N₂, CO₂, H₂
Standard ComplianceGB/T 1038-2000, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126, YBB00082003
Measurement Range0.05–50,000 cm³/m²·24h·0.1MPa (extendable to ≥500,000 cm³/m²·24h·0.1MPa)
Test Chambers3 independent
Vacuum Resolution0.1 Pa
Vacuum Level in Test Chamber<20 Pa
Temperature Control5–95 °C (±0.1 °C)
Humidity Control0%RH, 2–98.5%RH, 100%RH (optional humidifier) (±1%RH)
Specimen SizeΦ97 mm
Effective Permeation Area38.48 cm²
Test Pressure Range−0.1 to +0.1 MPa
Gas Supply Pressure0.4–0.6 MPa
Data InterfaceRS232
Software IntegrationLystem™ Laboratory Data Management System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelC230H Blister Oxygen Permeation Analyzer
Price RangeUSD 14,000 – 70,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelLabthink-C230H
Price RangeUSD 14,000 – 70,000
Test PrincipleIsostatic (Equal-Pressure) Method with Coulometric Oxygen Sensor
Standards ComplianceASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015
Test Range (Film)0.01–200 cm³/(m²·day)
Test Range (Package)0.00005–1 cm³/(pkg·day)
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C ±0.2 °C
Humidity Control0% RH, 5–90% RH ±1% RH, 100% RH
Test Chambers3 independent
Sample Area50 cm² (standard)
Max. Package Volume3 L
Sample Size108 mm × 108 mm
Max. Sample Thickness≤3 mm
Carrier Gas≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi)
Gas Interface1/8″ stainless steel tubing
Optional ModulesDataShield™ Data Integrity System, CFR 21 Part 11 Compliance Package, GMP Computer System Validation Support, Package Testing Kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC230H
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
Price RangeUSD 14,000 – 85,000
Test PrincipleCoulometric Sensor + Isobaric Method (ASTM D3985)
Test Range0.01–200 cm³/(m²·day)
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C (±0.2 °C)
Humidity Control0% RH, 5–90% RH (±1% RH), 100% RH
Test Chambers3 independent
Sample Area50 cm² (standard)
Max. Sample Size108 mm × 108 mm
Max. Thickness≤3 mm
Package Testing Capacityup to 3 L (optional)
Carrier Gas≥99.999% N₂, ≥0.28 MPa (40.6 psi)
Interface1/8″ stainless steel tubing
Data ComplianceOptional 21 CFR Part 11, GMP-compliant audit trail, DataShield™ secure data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelC230H
Price RangeUSD 14,000 – 85,000
Test PrincipleIsobaric Method with Coulometric Oxygen Sensor
Standards ComplianceASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015
Test Range0.01–200 cm³/(m²·day)
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C (±0.2 °C)
Humidity Control0% RH, 5–90% RH (±1% RH), 100% RH
Test Area50 cm²
Sample Size108 mm × 108 mm
Max Sample Thickness≤3 mm
Chamber Count3
Package Testing CapacityUp to 3 L (optional)
Carrier Gas≥99.999% N₂, ≥0.28 MPa (40.6 psi)
Gas Interface1/8″ stainless steel tubing
Data ManagementDataShield™ audit-trail-enabled software
Regulatory SupportOptional 21 CFR Part 11 compliance package
OSWindows 10 on 12″ industrial touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC230H
Test PrincipleIsobaric Method with Coulometric Oxygen Sensor
Standards ComplianceASTM D3985, ASTM F1307, ASTM F1927, GB/T 19789, GB/T 31354, DIN 53380, JIS K7126-2-B, YBB 00082003-2015
Test Range0.01–200 cm³/(m²·day)
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C (±0.2 °C)
Humidity Control0% RH, 5–90% RH (±1% RH), 100% RH
Test Chambers3 independent
Sample Size108 mm × 108 mm
Max Sample Thickness≤3 mm
Standard Test Area50 cm²
Carrier Gas≥99.999% high-purity N₂ (user-supplied)
Gas Inlet Pressure≥0.28 MPa (40.6 psi)
Gas Interface1/8″ stainless steel tubing
Optional FeaturesPackage testing (up to 3 L), DataShield™ Data Integrity System, CFR 21 Part 11 compliance package, GMP-compliant computer system validation support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM/ODM Producer
Country of OriginChina
ModelC230H
Price RangeUSD 14,000 – 70,000
Test PrincipleIsobaric Coulometric Oxygen Sensor Method (ASTM D3985 compliant)
Test Range0.01–200 cm³/(m²·day)
Resolution0.001 cm³/(m²·day)
Temp Control10–55 °C ±0.2 °C
RH Control0%RH, 5–90%RH ±1%RH, 100%RH
Sample Capacity3 cavities
Max Package Volume3 L
Standard Test Area50 cm²
Specimen Size108 mm × 108 mm
Max Thickness≤3 mm
Carrier Gas≥99.999% N₂, ≥0.28 MPa
Interface1/8″ stainless steel tubing
Data ComplianceOptional 21 CFR Part 11, GMP audit trail, DataShield™ secure export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC203H
Measurement PrincipleCoulometric Sensor + Isobaric Method
Standards ComplianceASTM D3985, ASTM F1307, GB/T 19789, ISO 15105-2 (implied), JIS K7126-2-B
Test Area50 cm² (standard, triple independent chambers)
OTR Range0.01–200 cc/(m²·day) (50 cm²)
Resolution0.0001 cc/(m²·day)
Repeatability±0.01 cc/(m²·day) or ±1%, whichever is greater
Temperature Control15–50 °C (±0.05 °C stability)
RH Control0–90% RH (±1% for O₂ side, ±2% for carrier gas side)
Sensor Lifetime≥3× conventional coulometric sensors
Sample Thickness Limit≤3 mm
Power Supply120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz
Net Weight100 kg
Dimensions600 × 500 × 700 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelC406H
Price RangeUSD 28,000 – 98,000
OTR Range0.02–200 cc/(m²·day) @ 50 cm²
WVTR Range0.02–40 g/(m²·day) @ 50 cm²
OTR Resolution0.0001 cc/(m²·day)
WVTR Resolution0.0001 g/(m²·day)
OTR Repeatability±0.02 cc/(m²·day) or ±1%, whichever is greater
WVTR Repeatability±0.02 g/(m²·day) or ±2%, whichever is greater
Temperature Control Range10–50 °C (optional: 5–60 °C)
Temp Stability±0.15 °C
RH Range0%, 5–90% ±2%, 100% RH
Test Chambers6 independent chambers
Standard Test Area50 cm²
Sample Size11.2 cm × 11.2 cm
Max Sample Thickness≤3 mm
Carrier Gas≥99.999% N₂, ≥99.5% O₂
Inlet Pressure≥280 kPa
Power Supply120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz
Net Weight100 kg
Dimensions60 cm × 49 cm × 66 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC203H
PrincipleCoulometric oxygen sensor + isobaric method
StandardsASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Range0.02–200 cc/(m²·day) (50 cm²), extendable to 400,000 cc/(m²·day)
Resolution0.0001 cc/(m²·day)
Repeatability±0.02 cc/(m²·day) or ±1%, whichever is greater
Temperature Range15–50 °C (standard), 5–60 °C (optional)
Temp. Stability±0.05 °C
Humidity Range0–90 %RH ±2 %RH
Test Area50 cm² (standard), 5 cm² / 1 cm² (optional masks)
Sample Size11.2 cm × 11.2 cm
Max. Thickness3 mm
Gas Supply99.999% N₂, 99.5% O₂
Inlet Pressure≥280 kPa
Power120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz
Dimensions600 mm × 500 mm × 700 mm
Weight100 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
RegionDomestic (China)
ModelC403H
Price RangeUSD 28,000 – 115,000
OTR Range0.01–200 cc/(m²·day) @ 50 cm²
WVTR Range0.005–40 g/(m²·day) @ 50 cm²
OTR Resolution0.0001 cc/(m²·day)
WVTR Resolution0.0001 g/(m²·day)
OTR Repeatability±0.01 cc/(m²·day) or ±1%, whichever is greater
WVTR Repeatability±0.005 g/(m²·day) or ±2%, whichever is greater
Temperature Range15–50 °C (optional 5–60 °C)
Temp Stability±0.05 °C
RH Range0–90 %RH ±2%
Test Chambers3 independent
Standard Test Area50 cm²
Sample Thickness Limit≤3 mm
Sample Size112 mm × 112 mm
Carrier Gas≥99.999% N₂, ≥99.5% O₂
Inlet Pressure≥280 kPa
Power120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz
Dimensions (W×D×H)600 × 500 × 700 mm