- All
- Favorite
- Popular
- Most rated
| Brand | Labthink |
|---|---|
| Model | W3/062 |
| Principle | Gravimetric Cup Method (Weight Gain/Loss) |
| Test Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 specimens simultaneously |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Chamber Volume | 45 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Compliance | ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Absorption Spectroscopy (ASTM F1249 / ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (optional: 5–60 °C) |
| Temp. Stability | ±0.15 °C |
| RH Range | 5–90 %RH ±2% (at standard temp.) / 100 %RH |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASKs |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% 60 Hz or 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C360H |
| Testing Methods | Gravimetric Gain & Loss Modes |
| Maximum WVTR (Loss Mode) | 10,000/n g/(m²·day) (n = 1–12) |
| Maximum WVTR (Gain Mode) | 1,200 g/(m²·day) per station |
| Test Stations | 12 |
| Temperature Range | 20–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Sample Thickness | ≤3 mm |
| Test Area | 33 cm² |
| Carrier Gas | Compressed Air (≥0.6 MPa) |
| Desiccant System | Core-free Long-life Dryer (20,000 h service life) |
| Humidification | Fog-free Integrated Humidifier |
| Data Management | DataShield™ Audit-Trail-Enabled Software |
| Regulatory Options | Optional 21 CFR Part 11 Compliance Package |
| GMP Computer System Validation Support | Optional |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Detection (ASTM F1249, ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 15–50 °C (optional: 5–60 °C), stability ±0.15 °C |
| RH Control | 5–90 %RH ±2% |
| Test Chambers | 6 independent chambers |
| Standard Test Area | 50 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥280 kPa |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions (W×D×H) | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 72,000 (based on configuration and regional duties) |
| Test Principle | Gravimetric cup method (weight gain/loss measurement) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Quantity | 1–3 independent cups |
| Test Accuracy | ±0.01 g/m²·24h |
| System Resolution | 0.0001 g |
| Temperature Control Range | 15–55 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 10–98 %RH (standard 90 %RH) |
| RH Stability | ±1 %RH |
| Sweep Air Velocity | 0.5–2.5 m/s (optional) |
| Test Area | 33 cm² |
| Max. Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions (L×W×H) | 580×680×470 mm |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Testing Principle | Electrolytic (Coulometric) Moisture Detection |
| Standards Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90 %RH (±1 %RH), optional 100 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Size | 108 mm × 108 mm |
| Max Thickness | ≤3 mm |
| Packaging Test Capacity | up to 3 L (optional) |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Data Management | DataShield™ audit-trail-enabled software |
| Regulatory Support | Optional 21 CFR Part 11 compliance package |
| GMP Computer System Validation Support | Optional |
| Brand | Labthink |
|---|---|
| Model | W3/062 |
| Measurement Principle | Gravimetric Cup Method (ASTM E96 / ISO 2528) |
| Test Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 independent specimens |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Weight Resolution | 0.001 g |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Detection of Water Vapor |
| Standards Compliance | ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015 |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| WVTR Range | 0.02–40 g/(m²·day) [50 cm²], 0.2–400 g/(m²·day) [5 cm²], 1–2000 g/(m²·day) [1 cm²] |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Temp. Stability | ±0.15 °C |
| Humidity Range | 100% RH, or 5–90% RH ±2% RH |
| Test Chambers | 6 independent |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Carrier Gas | 99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C360M |
| Test Principle | Gravimetric (ASTM E96 / GB 1037 compliant) |
| Test Modes | Gain-Weight & Loss-Weight |
| Test Stations | 6 independent chambers |
| Temperature Range | 15–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Max Sample Thickness | ≤3 mm |
| Effective Test Area | 33 cm² |
| WVTR Range (Loss-Weight) | up to 10,000/n g/(m²·day) [n = 1–6] |
| WVTR Range (Gain-Weight) | up to 1200 g/(m²·day) per station |
| Carrier Gas | Compressed air (≥0.6 MPa) |
| Drying System | Core-free, 20,000-hour service life |
| Humidification | Fog-free internal humidifier |
| Data Management | DataShield™ audit-trail-enabled software |
| Regulatory Compliance Options | 21 CFR Part 11, GMP-compliant computer system validation support |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W3/062 |
| Test Principle | Gravimetric Cup Method (Weight Loss/Gain) |
| Measurement Range | 0.1–10,000 g/m²·24h (weight loss mode) |
| Sample Capacity | 1–6 independent specimens per test cycle |
| Temperature Control | 15–55 °C (±0.1 °C accuracy) |
| Humidity Control | 10–98% RH (±1% RH accuracy) |
| Test Area | 33 cm² |
| Specimen Thickness Limit | ≤3 mm |
| Chamber Volume | 45 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Compliance Standards | GB 1037, GB/T 16928, ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Price Range | USD 28,000 – 70,000 |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH (100 %RH optional) |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, min. pressure 0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Compliance Modules | DataShield™ Data Integrity System, 21 CFR Part 11 compliance package, GMP-compliant computer system validation support |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Infrared Detection per ASTM F1249 & ISO 15106-2 |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| WVTR Range | 0.02–40 g/(m²·day) (50 cm²), 0.2–400 g/(m²·day) (5 cm²), 1–2000 g/(m²·day) (1 cm²) |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), 5–60 °C (custom) |
| Temp Stability | ±0.05 °C |
| RH Range | 5–90 %RH ±2 %RH |
| Chamber Configuration | Triple independent test chambers |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Inlet | 1/8″ stainless steel tube |
| Power | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Coulometric Electrolytic Sensor (ISO 15106-3) |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90 %RH (±1 %RH), optional 100 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Packaging Test Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Compliance Modules | DataShield™ Data Integrity System, 21 CFR Part 11 Audit Trail, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Principle | Gravimetric Cup Method |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.0001 g |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Purge Air Velocity | 0.5–2.5 m/s |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH (up to 100 %RH optional) |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | 3 mm |
| Packaging Test Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa |
| Gas Inlet Fitting | 1/8″ stainless steel tubing |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015 |
| Data Integrity Options | CFR 21 Part 11-compliant audit trail, DataShield™ secure data management (optional) |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Range | 0.005–40 g/(m²·day) (50 cm²), 0.005–100 g/(m²·day) (50 cm²), 0.05–400 g/(m²·day) (5 cm² mask), 0.25–2000 g/(m²·day) (1 cm² mask) |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), optional 5–60 °C |
| Temp. Stability | ±0.05 °C |
| RH Range | 5–90 %RH ±1 %RH |
| Test Area | 50 cm² (standard), 5 cm² / 1 cm² (optional masks) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Compliance | ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015 |
| Brand | Labthink |
|---|---|
| Model | C360M |
| Principle | Gravimetric (Weight Gain/Loss Method) |
| Standards | ASTM E96, GB 1037, GB/T 16928, ISO 2528, YBB00092003-2015 |
| Test Stations | 6 |
| Temperature Range | 15–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Max Thickness | ≤3 mm |
| Test Area | 33 cm² |
| WVTR Range (Loss Mode) | up to 10,000/n g/(m²·day) (n = 1–6) |
| WVTR Range (Gain Mode) | up to 1200 g/(m²·day) per station |
| Carrier Gas | Compressed Air (≥0.6 MPa) |
| Drying System | Coreless Long-Life Desiccant Module (20,000 h operational life) |
| Humidification | Internal Fog-Free Steam Generator |
| Data Compliance | Optional 21 CFR Part 11 & GMP Audit Trail Support |
| OS | Windows 10 Embedded on 12″ Touchscreen Tablet |
| Software | DataShield™ Secure Data Management Platform |
| Brand | Labthink |
|---|---|
| Model | PERME W3/031 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 14,000–57,000 |
| Test Principle | Gravimetric Cup Method (ASTM E96, GB/T 1037) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Measurement Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Air Supply | 0.6 MPa, Φ4 mm PU tubing |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Net Weight | 83 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer | Labthink Co., Ltd. |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| RH Control | 5–90% RH (±1% RH), optional 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Package Volume | 3 L |
| Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa (40.6 psi) |
| Interface | 1/8″ stainless steel tubing |
| Optional Compliance | 21 CFR Part 11, GMP Data Integrity, DataShield™ Audit-Trail System |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Electrolytic (Coulometric) Moisture Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% (whichever is greater) |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90% RH ±1% RH (with optional 100% RH capability) |
| Test Chambers | 3 independent, simultaneous |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi), 1/8″ metal tubing interface |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015 |
| Optional Modules | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Package, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Category | Packaging Industry–Specific WVTR Tester |
| Test Principle | Gravimetric Cup Method (ASTM E96 Desiccant Method) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g |
| Temperature Control | 15–55 °C, ±0.1 °C |
| Humidity Control | 10–98% RH, ±1% RH |
| Test Area | 33 cm² |
| Sample Thickness Limit | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | AC 85–264 V, 47–63 Hz |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Net Weight | 83 kg |
| Compliance | GB 1037, GB/T 16928, ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | W3/062-PERME |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Application Category | Packaging & Medical Film Barrier Testing |
| Test Principle | Gravimetric Cup Method (ASTM E96, GB 1037, ISO 2528) |
| Measurement Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 specimens per test cycle (independent channels) |
| Temperature Control | 15–55 °C ±0.1 °C |
| Humidity Control | 10–98% RH ±1% RH |
| Test Area | 33 cm² |
| Specimen Diameter | Φ74 mm |
| Max Thickness | ≤3 mm |
| Weight Resolution | 0.001 g |
| WVTR Resolution | 0.01 g/m²·24h |
| Air Supply | 0.6 MPa, Φ6 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90% RH ±1% RH (with optional 100% RH capability) |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L (optional) |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003–2015 |
| Optional Features | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Module, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer | Labthink Co., Ltd. |
| Type | Gravimetric Cup Method WVTR Tester |
| Compliance | ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Airflow Velocity | 0.5–2.5 m/s |
| Chamber Volume | 27 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
Show next