Empowering Scientific Discovery

Jinan Lan Guang Mechanical & Electrical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelC611B
Force Sensor Capacity3 × 9 kN
Force Accuracy±1% of reading (10–100% FS), ±0.1% FS (0–10% FS)
Force Resolution1 N
Deformation Resolution0.1 mm
Test Speed Range0–200 mm/min (adjustable in integer steps)
Speed Accuracy±2% of set value
Maximum Travel450 mm
Specimen Height Range0–600 mm
Test Chamber Dimensions600 mm (L) × 600 mm (W) × 610 mm (H)
Overall Dimensions650 mm (L) × 810 mm (W) × 1620 mm (H)
Weight180 kg
Power SupplyAC 220 V ±10%, 50 Hz OR AC 120 V ±10%, 60 Hz (user-selectable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelW3/062
PrincipleGravimetric Cup Method (Weight Gain/Loss)
Test Range0.1–10,000 g/m²·24h (loss mode)
Sample Capacity1–6 specimens simultaneously
Temperature Control15–55 °C (±0.1 °C)
Humidity Control10–98 %RH (±1 %RH)
Test Area33 cm²
Specimen Thickness≤3 mm
Chamber Volume45 L
Power Supply220 VAC 50 Hz / 120 VAC 60 Hz
Net Weight80 kg
ComplianceASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC390H
Measurement PrincipleInfrared Detection of Water Vapor
Standards ComplianceASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015
Test Range0.005–40 g/(m²·day) (film), 0.0003–2.6 g/(100in²·day), 0.000025–0.2 g/(pkg·day) (containers)
Resolution0.0001 g/(m²·day)
Repeatability±0.005 g/(m²·day) or ±2% (whichever is greater)
Temperature Control10–55 °C (±0.2 °C)
Humidity Control5–90 % RH (±1 % RH), up to 100 % RH
Test Chambers3 independent, integrated cavities
Sample Area50 cm² (standard)
Max Container Volume3 L
Sample Dimensions≤108 mm × 108 mm × 3 mm
Carrier Gas99.999% pure N₂, inlet pressure ≥0.28 MPa (40.6 psi)
Gas Interface1/8″ stainless steel tubing
Data ManagementDataShield™ audit-trail-enabled software
Regulatory SupportOptional 21 CFR Part 11 compliance, GMP-compliant computer system validation package
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelC106H Gas Permeation Analyzer
Price RangeUSD 14,000 – 98,000
Test PrincipleDifferential Pressure Method (ISO 15105-1, ASTM D1434, GB/T 1038-2000)
Test GasesO₂, N₂, CO₂
Measurement Range0.01–50,000 cm³/m²·24h·0.1MPa
Resolution0.001 cm³/m²·24h·0.1MPa
Temperature Range15–50 °C (5–60 °C optional)
Temp. Stability±0.15 °C
Vacuum Capability≤10 Pa (Resolution: 0.01 Pa
Accuracy±0.2% of reading in 1–100% sensor span)
Test Area38.48 cm²
Sample Size11.2 cm × 11.2 cm
Max. Sample Thickness3 mm
Test Pressure Range10–150 kPa (adjustable
pressure stability±0.2 kPa)
Humidity Control0% RH or 5–90% ±2% RH (customizable)
Power Supply120 VAC ±10%, 60 Hz / 220 VAC ±10%, 50 Hz (selectable)
Dimensions600 × 490 × 660 mm
Weight100 kg
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Labthink
ModelMCJ-01A
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Compliance StandardGB/T 7706
Applied Load20 ± 0.2 N
Stroke Frequency43 cycles per minute (cpm)
Abrasion Area155 mm (L) × 50 mm (W)
Cycle Count Range0–999
Specimen Size230 mm (L) × 50 mm (W)
Power Supply220 VAC, 50 Hz / 120 VAC, 60 Hz
Dimensions (L×W×H)260 × 230 × 360 mm
Net Weight22 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelVAC-V2
Measurement PrincipleDifferential Pressure (ASTM D1434, ISO 15105-1, GB/T 1038-2000)
Test GasesN₂, O₂, CO₂, Air, He (customizable for flammable/explosive gases)
Test Range0.05–50,000 cm³/m²·24h·0.1MPa (expandable to ≥500,000 cm³/m²·24h·0.1MPa)
Independent Test Chambers3
Temperature Control5–95 °C (±0.1 °C)
Humidity Control0%RH, 2–98.5%RH, 100%RH (optional humidity generator)
Vacuum Resolution0.1 Pa
Chamber Vacuum Level<20 Pa
Sample Area38.48 cm²
Sample DiameterΦ97 mm
Power Supply220VAC 50Hz / 120VAC 60Hz
Net Weight88 kg
Dimensions760 × 575 × 450 mm (L×W×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelQYC-E
MaterialASTM F86-Compliant 316L Stainless Steel
Design ComplianceEN 13130-1:2004 Annex D, Figure D.6 (Migration Test Cell C)
Standard ConformanceGB 31604.1-2015, GB 5009.156-2016
Contact ConfigurationSingle- or Double-Sided Exposure
Single-Side Exposure Area100 cm² (Ø112.8 mm)
Double-Side Exposure Area200 cm²
Chamber Volume200 mL
Operating Temperature Range5 °C to 180 °C
Dimensions (L×W×H)175 × 140 × 63 mm
Net Weight2.3 kg
Sealing SystemHigh-Temperature Resistant, Chemically Inert Fluoroelastomer (FKM) Gasket
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
ManufacturerLabthink Instruments Co., Ltd.
ModelMXD-01
Load Range0–5 N
Accuracy ClassClass 1
Travel Distance10 mm + 60 mm
Slider Mass Options200 g, 500 g (1000 g optional)
Test Speed100 mm/min
Temperature Range10–40 °C
Relative Humidity Range20–70 %RH
Power Supply220 VAC 50 Hz / 120 VAC 60 Hz
Dimensions (L×W×H)470 × 310 × 200 mm
Net Weight31 kg
ComplianceGB 10006, ISO 8295
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC306H
Measurement PrincipleInfrared Absorption Spectroscopy (ASTM F1249 / ISO 15106-2)
Test Range0.02–40 g/(m²·day) @ 50 cm²
Resolution0.0001 g/(m²·day)
Repeatability±0.02 g/(m²·day) or ±2%, whichever is greater
Temperature Range15–50 °C (optional: 5–60 °C)
Temp. Stability±0.15 °C
RH Range5–90 %RH ±2% (at standard temp.) / 100 %RH
Test Area50 cm² (standard), optional 5 cm² or 1 cm² MASKs
Sample Size11.2 cm × 11.2 cm
Max. Thickness3 mm
Carrier Gas≥99.999% N₂, ≥280 kPa inlet pressure
Power Supply120 VAC ±10% 60 Hz or 220 VAC ±10% 50 Hz
Dimensions600 × 490 × 660 mm
Weight100 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
ManufacturerLabthink Instruments Co., Ltd.
ModelHST-H3
Temperature RangeAmbient to 300 °C
Temperature Control Accuracy±0.2 °C
Sealing Time0.1–999.9 s
Sealing Pressure0.05–0.7 MPa
Sealing Surface Dimensions330 mm × 10 mm (customizable)
Heating ConfigurationIndependent dual-zone heating (top and bottom jaws)
Pneumatic Supply Requirement0.5–0.7 MPa (user-supplied air source, Ø6 mm polyurethane tubing)
Power Supply220 VAC 50 Hz / 120 VAC 60 Hz
Net Weight43 kg
Compliance StandardsQB/T 2358, ASTM F2029, YBB00122003
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC660B
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Product CategoryDomestic Instrument
Price RangeUSD 1,400 – 4,200
Vacuum Range0 to −90 kPa (0 to −13 psi)
Vacuum Accuracy±0.25% FS
Vacuum Resolution0.1 kPa / 0.01 psi
Vacuum Hold Time0–9999 min 59 sec
Standard Vacuum Chamber DimensionsΦ270 mm × 210 mm (H)
Power Supply220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz
Net Weight6.5 kg (host), 9 kg (standard chamber)
Compliance StandardsGB/T 15171, ASTM D3078
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelMXD-02
Price RangeUSD 1,400 – 8,500
Load Range0–5 N
Accuracy Class0.5
Travel Distance70 mm / 150 mm
Standard Sled Mass200 g (customizable sleds available)
Test Speeds100 mm/min, 150 mm/min (adjustable)
Environmental Requirements23 ± 2 °C, 20–70 %RH
Power Supply220 VAC 50 Hz / 120 VAC 60 Hz
Dimensions (L×W×H)630 × 360 × 230 mm
Net Weight33 kg
Compliance StandardsISO 8295, GB 10006, ASTM D1894, TAPPI T816
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelBMC-B1
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Regional CategoryDomestic (China)
ComplianceGB/T 15267–1994
ApplicationImpact Resistance Testing of Rigid PVC Sheets for Food Packaging
Test PrincipleControlled-height steel ball drop onto clamped specimen under standardized conditions
Reporting MetricPercent Breakage Rate (defined as complete separation into ≥2 fragments)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelPARAM-BOMEI MED-01
PricingUpon Request
Force Capacity250 N (Standard)
Optional50 N, 100 N, 500 N
Customizable750 N, 1000 N
Accuracy ClassBetter than 0.5
Test Speed (Extension/Retraction)10, 50, 100, 150, 200, 300 mm/min (Standard)
Sample Width30 mm (Standard Fixture)
Stroke600 mm
Dimensions (L×W×H)851 × 500 × 940 mm
Weight68 kg
Power Supply220 VAC 50 Hz / 120 VAC 60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelC660B
Vacuum Range0 to –90 kPa (0 to –13 psi)
Vacuum Accuracy±0.25% FS
Vacuum Resolution0.1 kPa / 0.01 psi
Vacuum Hold Time0–9999 min 59 sec
Standard Vacuum Chamber DimensionsΦ270 mm × 210 mm (H)
Power Supply220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz
Net Weight6.5 kg (host), 9 kg (standard chamber)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
ManufacturerJinan Labthink Electromechanical Technology Co., Ltd.
ModelTQD-G1A
Pressure Drop Range0–1000 Pa
Pressure Resolution0.1 Pa
Pressure Accuracy±0.25% FS
Flow Rate Range0–30 L/min
Flow Resolution0.1 L/min
Flow Accuracy±2% FS
Test Area20 cm² (standard, customizable)
Sample Size5 cm × 5 cm
Max Sample Thickness1 mm
Gas SupplyClean compressed air (user-supplied, ≥550 kPa, >120 L/min)
Power120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz
Dimensions300 mm × 460 mm × 520 mm
Weight25 kg
InterfaceRS232 (optional software integration)
Display7" industrial color touchscreen
ComplianceISO 9237, ISO 4638, ISO 5636, GB/T 5453, GB/T 10655, GB/T 4689.22, GB/T 13764, ASTM D737, TAPPI T460, JIS P8117
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic
ModelC230H
PricingUpon Request
Test PrincipleCoulometric Oxygen Sensor + Isobaric Method
Standards ComplianceASTM D3985, ASTM F1307, ASTM F1927 (optional), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Film OTR Range0.01–200 cm³/(m²·day)
Container OTR Range0.00005–1 cm³/(pkg·day)
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Test Temperature10–55 °C (±0.2 °C)
RH Control0%, 5–90% (±1%), 100% (O₂ side)
Test Chambers3 independent chambers
Sample Size108 mm × 108 mm
Max Sample Thickness≤3 mm
Standard Test Area50 cm²
Carrier Gas≥99.999% high-purity N₂ (user-supplied)
Inlet Pressure≥0.28 MPa (40.6 psi)
Gas Interface1/8″ stainless steel tubing
Max Container Volume3 L (optional)
DataShield™ Data Integrity ModuleOptional
GMP-Compliant Software & Audit TrailOptional
21 CFR Part 11 Compliance SupportOptional
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelHST-H3 Dual-Head Independent Temperature-Controlled Heat Sealer
Price RangeUSD 1,400 – 8,500
Heat Seal Temperature RangeAmbient to 300 °C
Temperature Control Accuracy±0.2 °C
Seal Time Range0.1–999.9 s
Seal Pressure Range0.05–0.7 MPa
Seal Jaw Dimensions330 mm × 10 mm (customizable)
Heating ModeSingle or Dual Independent Heating
Pneumatic Supply Requirement0.5–0.7 MPa
Air Inlet FittingΦ6 mm Polyurethane Tubing
Overall Dimensions536 mm (L) × 335 mm (W) × 413 mm (H)
Power SupplyAC 220 V, 50 Hz
Net Weight43 kg
Compliance StandardsQB/T 2358, ASTM F2029, YBB00122003
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
ModelLabthink FT-F1
Temperature Range (Hot Chamber)Ambient to 150 °C (optional up to 280 °C)
Hot Chamber Temperature Stability±0.1 °C at 150 °C
Cold Chamber Temperature Range0–100 °C
Cold Chamber Temperature Stability±0.1 °C
Hot Chamber Dimensions (L×W×H)670 × 490 × 540 mm
Cold Chamber Dimensions (L×W×H)400 × 220 × 520 mm
Test Stations6 (simultaneous sample + blank testing)
ComplianceASTM D5330, ISO 6452, DIN 75201, SAE J1756, GB/T 27630
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelGHS-03
OriginShandong, China
ManufacturerLabthink Instruments Co., Ltd.
ApplicationHeat seal parameter optimization for flexible packaging films and laminates
Heat Seal Temperature Range25–250 °C
Temperature Control Accuracy±0.2 °C
Temperature Gradient Across Five Stations≤20 °C
Heat Seal Pressure Range0.1–0.7 MPa
Heat Seal Time Range0.1–999.9 s
Sealing Surface Dimensions40 mm × 10 mm × 5 stations
Power SupplyAC 220 V, 50 Hz
Net Weight72 kg
Dimensions (L×W×H)576 × 430 × 510 mm
Compressed Air Requirement0.1–0.7 MPa via Ø8 mm polyurethane tubing (user-supplied)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelMED-01
Force Range250 N (standard)
optional50 N, 100 N, 500 N
customizable750 N, 1000 N
AccuracyBetter than Class 0.5 per ISO 376
Test Speed (Approach/Return)10, 50, 100, 150, 200, 300 mm/min (standard)
Sample Width30 mm (standard fixture), 50 mm (optional)
Sample HolderManual clamping
Maximum Travel600 mm
Dimensions (L×W×H)851 × 500 × 940 mm
Power Supply220 VAC 50 Hz / 120 VAC 60 Hz
Net Weight68 kg
ComplianceGB 2637–2014, YBB 00332002–2015
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC230H
OriginShandong, China
Manufacturer TypeOEM/ODM Producer
Country of OriginChina
Price RangeUSD 14,000 – 85,000
Test PrincipleIsobaric Method with Coulometric Oxygen Sensor
Standards ComplianceASTM D3985, ASTM F1307, ASTM F1927 (optional), GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
Test Range0.01–200 cm³/(m²·day) [film]
Resolution0.001 cm³/(m²·day)
Repeatability±0.01 cm³/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C (±0.2 °C)
Humidity Control0–90% RH (±1% RH), 100% RH (optional)
Test Chambers3 independent chambers
Sample Area50 cm² (standard)
Max. Sample Size108 mm × 108 mm
Max. Thickness≤3 mm
Package Testing Capacityup to 3 L
Carrier Gas≥99.999% high-purity N₂
Inlet Pressure≥0.28 MPa (40.6 psi)
Gas Interface1/8″ stainless steel tubing
Optional FeaturesDataShield™ Data Integrity System, CFR 21 Part 11 Compliance Module, GMP Computer System Validation Support, Package Testing Mode
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelC360H
Testing MethodsGravimetric Gain & Loss Modes
Maximum WVTR (Loss Mode)10,000/n g/(m²·day) (n = 1–12)
Maximum WVTR (Gain Mode)1,200 g/(m²·day) per station
Test Stations12
Temperature Range20–55 °C ±0.2 °C
Humidity Range10–90 %RH ±1 %RH
Sample DiameterΦ74 mm
Sample Thickness≤3 mm
Test Area33 cm²
Carrier GasCompressed Air (≥0.6 MPa)
Desiccant SystemCore-free Long-life Dryer (20,000 h service life)
HumidificationFog-free Integrated Humidifier
Data ManagementDataShield™ Audit-Trail-Enabled Software
Regulatory OptionsOptional 21 CFR Part 11 Compliance Package
GMP Computer System Validation SupportOptional
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
ManufacturerJinan Labthink Electromechanical Technology Co., Ltd.
ModelQYC-E
MaterialASTM F86-compliant 316 stainless steel (body, sealing bolts, base feet)
Contact ConfigurationSingle- or double-sided exposure
Single-Side Exposure Area100 cm² (Φ112.8 mm)
Double-Side Exposure Area200 cm²
Cell Volume200 mL
Operating Temperature Range5 °C to 180 °C
Dimensions (L×W×H)175 mm × 140 mm × 63 mm
Net Weight2.3 kg
ComplianceGB 5009.156–2016, GB 31604.1–2015, EN 13130-1:2004 Annex D, Figure D.6 (Migration Test Cell C)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0