- All
- Favorite
- Popular
- Most rated
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | RCP-50 |
| Capacity | 50 L |
| Operating Temperature Range | ≥10 °C to 135 °C |
| Maximum Working Pressure | 0–0.22 MPa |
| Timer Range | 0–999 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 2 kW |
| Cooling Method | Forced-air cooling with back-pressure compensation |
| Safety Features | Over-temperature, over-pressure, low-water-level, and leakage protection |
| Compliance Documentation | Full set of calibration certificates, verification reports, and metrological traceability records per Chinese National Verification Regulation JJG 974–2021 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | C330H |
| Quotation | Upon Request |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Package Testing | Optional (up to 3 L) |
| Data Management | DataShield™ Audit-Trail Enabled |
| Compliance Options | 21 CFR Part 11, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | GC Series |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Application | Quantitative determination of residual ethylene oxide in EO-sterilized medical devices and personal protective equipment (PPE) |
| Detection Principle | Headspace gas chromatography (HS-GC) with flame ionization detection (FID) |
| Compliance Standards | GB/T 14233.1–2008, GB/T 16886.7–2001, ISO 10993-7, ASTM F2573, USP <801>, FDA 21 CFR Part 11 (software-enabled audit trail & electronic signature support) |
| Sample Preparation | Aqueous extraction followed by thermal equilibration in sealed headspace vials |
| Detection Limit | ≤0.1 µg/g (as per method validation per ISO/IEC 17025) |
| Linear Range | 0.5–50 µg/g EO in solid matrix |
| Calibration Method | Gravimetric standard stock solution preparation (1 × 10⁻² g/L), serial dilution, six-point calibration curve |
| Data Output | Peak area or height vs. concentration |
| Brand | Labthink |
|---|---|
| Model | GC-7800 |
| Detection Principle | Headspace Gas Chromatography with Dual FID/TCD Detectors |
| Temperature Control Accuracy | ±0.1°C (sample chambers), ±0.5°C (gas lines & valve oven) |
| Sample Capacity | Dual 300 mL headspace vials |
| Injection Volume | 1.0 mL (optional: 0.5/2/3 mL) |
| Programmable Temperature Ramping | 5-stage linear, 1–30 °C/min |
| Column Oven Stability | <±0.1°C, gradient ≤1% across active zone |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene/H₂) |
| Data System | PC-based chromatography workstation with audit trail, method validation support, and GLP-compliant reporting |
| Brand | Labthink |
|---|---|
| Model | C612M |
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Torque Sensor Range | 5 N·m (standard) |
| Accuracy | ±0.5% of reading (10–100% FS) |
| Resolution | 0.0001 N·m |
| Cap Holding Diameter | Φ10–Φ80 mm |
| Bottle Body Holding Diameter | Φ5–Φ170 mm |
| Bottle Height Range | 20–400 mm |
| Max Test Torque | 2 N·m (customizable) |
| Air Supply Requirement | 0.7 MPa (101.5 psi), clean dry air (user-supplied) |
| Statistical Batch Size | 0–999 samples |
| Dimensions (L×W×H) | 550 × 365 × 1150 mm |
| Weight | 39 kg |
| Power | 220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (dual-voltage compatible) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W3/062 |
| Pricing | Available Upon Request |