BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelRCP-50
Capacity50 L
Operating Temperature Range≥10 °C to 135 °C
Maximum Working Pressure0–0.22 MPa
Timer Range0–999 min
Power SupplyAC 220 V, 50 Hz
Rated Power2 kW
Cooling MethodForced-air cooling with back-pressure compensation
Safety FeaturesOver-temperature, over-pressure, low-water-level, and leakage protection
Compliance DocumentationFull set of calibration certificates, verification reports, and metrological traceability records per Chinese National Verification Regulation JJG 974–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelC330H
QuotationUpon Request
Test PrincipleElectrolytic (Coulometric) Sensor per ISO 15106-3
Test Range0.005–50 g/(m²·day)
Resolution0.001 g/(m²·day)
Repeatability±0.005 g/(m²·day) or ±2%, whichever is greater
Temperature Control10–55 °C ±0.2 °C
Humidity Control5–90 %RH ±1 %RH
Test Chambers3 independent
Sample Area50 cm²
Max Sample Size108 mm × 108 mm
Max Sample Thickness≤3 mm
Package TestingOptional (up to 3 L)
Data ManagementDataShield™ Audit-Trail Enabled
Compliance Options21 CFR Part 11, GMP Computer System Validation Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelGC Series
OriginShandong, China
ManufacturerLabthink Instruments Co., Ltd.
ApplicationQuantitative determination of residual ethylene oxide in EO-sterilized medical devices and personal protective equipment (PPE)
Detection PrincipleHeadspace gas chromatography (HS-GC) with flame ionization detection (FID)
Compliance StandardsGB/T 14233.1–2008, GB/T 16886.7–2001, ISO 10993-7, ASTM F2573, USP <801>, FDA 21 CFR Part 11 (software-enabled audit trail & electronic signature support)
Sample PreparationAqueous extraction followed by thermal equilibration in sealed headspace vials
Detection Limit≤0.1 µg/g (as per method validation per ISO/IEC 17025)
Linear Range0.5–50 µg/g EO in solid matrix
Calibration MethodGravimetric standard stock solution preparation (1 × 10⁻² g/L), serial dilution, six-point calibration curve
Data OutputPeak area or height vs. concentration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelGC-7800
Detection PrincipleHeadspace Gas Chromatography with Dual FID/TCD Detectors
Temperature Control Accuracy±0.1°C (sample chambers), ±0.5°C (gas lines & valve oven)
Sample CapacityDual 300 mL headspace vials
Injection Volume1.0 mL (optional: 0.5/2/3 mL)
Programmable Temperature Ramping5-stage linear, 1–30 °C/min
Column Oven Stability<±0.1°C, gradient ≤1% across active zone
FID Detection Limit≤1×10⁻¹¹ g/s (benzene)
TCD Sensitivity≥3000 mV·mL/mg (benzene/H₂)
Data SystemPC-based chromatography workstation with audit trail, method validation support, and GLP-compliant reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
ModelC612M
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
Torque Sensor Range5 N·m (standard)
Accuracy±0.5% of reading (10–100% FS)
Resolution0.0001 N·m
Cap Holding DiameterΦ10–Φ80 mm
Bottle Body Holding DiameterΦ5–Φ170 mm
Bottle Height Range20–400 mm
Max Test Torque2 N·m (customizable)
Air Supply Requirement0.7 MPa (101.5 psi), clean dry air (user-supplied)
Statistical Batch Size0–999 samples
Dimensions (L×W×H)550 × 365 × 1150 mm
Weight39 kg
Power220 VAC ±10%, 50 Hz or 120 VAC ±10%, 60 Hz (dual-voltage compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLabthink
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelW3/062
PricingAvailable Upon Request