Empowering Scientific Discovery

Leica Microsystems (Shanghai) Trading Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelTCS SP8 DLS
Imaging PrincipleOrthogonal light-sheet illumination integrated with confocal detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelTCS SP8 CARS
Laser ModalitiesVisible, UV, IR, SHG, CARS
Imaging ModesSingle-photon fluorescence, multiphoton fluorescence, CARS, SHG, spectral unmixing
Scan SystemsDual scanning architecture (standard resonant + high-speed resonant/galvo)
Software PlatformLAS X (successor to LAS AF), FDA 21 CFR Part 11 compliant modules available
ComplianceISO 13485–certified manufacturing, CE-marked, GLP/GMP-ready audit trail support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelTCS SP8 SMD
Application DomainSingle-Molecule Detection (SMD), Fluorescence Correlation Spectroscopy (FCS), Fluorescence Cross-Correlation Spectroscopy (FCCS), Fluorescence Lifetime Imaging Microscopy (FLIM), Fluorescence Lifetime Correlation Spectroscopy (FLCS)
Integrated Hardware PlatformPicoQuant MD-series detection modules and timing electronics
Software IntegrationPicoQuant SymPhoTime 64 (SMD-optimized edition)
Optical ArchitectureInverted confocal platform with tunable white-light laser (WLL), spectral detection (HyD detectors), and time-correlated single-photon counting (TCSPC) capability
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelSTELLARIS CRS
Instrument TypePoint-Scanning Confocal Microscope
ExcitationNear-Infrared (NIR) Lasers
Imaging ModalitiesStimulated Raman Scattering (SRS), Coherent Anti-Stokes Raman Scattering (CARS), Multiphoton Fluorescence, Second Harmonic Generation (SHG), FLIM
Spatial ResolutionSubcellular (≤ 300 nm lateral, ≤ 1 µm axial)
DetectionSpectral Unmixing, TauSense Lifetime-Gated Acquisition
Software PlatformLAS X with ImageCompass Interface
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelTCS SP8 MP
Instrument TypePoint-Scanning Multiphoton Confocal Microscope
Excitation Range680–1300 nm
Maximum IR Wavelength1300 nm
Resonant Scanner Speed8 kHz / 12 kHz
Field of View (FOV)up to 22 mm
DetectionLeica HyD NDD & HyD RLD non-descanned detectors
Objective CorrectionmotCORR electrically adjustable correction collar
Specialized ObjectivesHC IRAPO L 25×/1.00 W motCORR, HC FLUOTAR L 25×/1.00 IMM (ne=1.457) motCORR VISIR, APO HCX L20×/0.95 IMM for BABB immersion (ne=1.559)
Software PlatformLAS X with integrated multiphoton control, FLIM wizard, and STED/FLIM/SMD module compatibility
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
Country of OriginGermany
ModelSTELLARIS STED
Excitation Wavelength Range440–790 nm (White Light Laser)
STED Depletion Wavelengths592 nm, 660 nm, 775 nm
Spatial Resolution<30 nm (lateral), <100 nm (axial), sample- and fluorophore-dependent
DetectionUp to 5 spectral Power HyD detectors with 1.5 ns system dead time
Objective OptionsSTED WHITE 100× oil, 93× glycerol (motCORR), 86× water (motCORR)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelSTELLARIS Cryo
Application DomainCryo-Correlative Light and Electron Microscopy (Cryo-CLEM)
Cooling StageIntegrated Liquid Nitrogen–Cooled Stage with Transfer Shuttle
Software PlatformLAS X Coral Cryo (with TauSense, LIGHTNING, and Interpolated 3D Targeting)
Objective LensHC PL APO 50×/0.90 Cryo-Optimized Dry Objective
Detection SystemPower HyD Hybrid Detectors
Light SourceWhite Light Laser (WLL, 470–670 nm)
Imaging ModesConfocal Reflectance, Fluorescence, TauContrast, TauSeparation, Spectral Unmixing
Ice Thickness AssessmentDual-mode (Overview + Confocal Reflectance Z-Stack)
Data FormatOpen, Metadata-Rich TIFF & HDF5 (CF-1 compliant)
Regulatory AlignmentDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMICA Widefield-Confocal
Instrument TypePoint-Scanning Confocal Microscope
Lasers405 nm, 488 nm, 561 nm, 638 nm
Fluorescence DetectorsStandard configuration with four HyD detectors and four sCMOS cameras
Optical Zoom1–6×
Microscope HostFully motorized inverted fluorescence microscope
Illumination SourcesLaser + LED
Software & WorkstationIntuitive GUI with integrated Pixel Classifier AI module
Vibration IsolationPassive anti-vibration table
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelSTELLARIS 8 DIVE
Instrument TypePoint-Scanning Confocal Microscope
Excitation RangeUp to 1300 nm
Detection Range380–800 nm (tunable via 4Tune spectral detector)
Core TechnologyTunable non-descanned spectral detection with variable beam expander (VBE)
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelTCS SP8 X
Excitation SourceTunable White Light Laser (WLL), Pulsed
Detection ChannelsUp to 5 Spectral Detection Channels
Excitation LinesUp to 8 Simultaneous Lines
FLIM CompatibilityYes, with Adjustable Repetition Rate via Pulse Picker
LightGate TechnologyTime-Gated Spectral Detection
Spectral ResolutionContinuous Excitation & Emission Acquisition (Excitation–Emission Matrix Mapping)
Application ScopeLive-Cell Imaging, Multicolor Fluorescence, Spectral Unmixing, FLIM, pH/Binding Microenvironment Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
Country of OriginGermany
ModelLeica STELLARIS STED
Instrument TypePoint-Scanning Confocal Microscope
STED Laser Wavelengths592 nm, 660 nm, 775 nm
Excitation Range440–790 nm (White Light Laser)
DetectionUp to 5 spectral Power HyD detectors (HyD S/X/R), 1.5 ns system dead time
Objective SupportSTED-optimized STED WHITE 100× oil, 93× glycerol (motCORR), 86× water (motCORR)
Resolution<30 nm lateral, <100 nm axial (sample- and fluorophore-dependent)
Core TechnologyTime-gated STED (TauSTED Xtend), TauSense-enabled lifetime discrimination, FLIM-capable with FALCON module
Software PlatformLAS X with ImageCompass, LAS X Navigator, TauSense tools
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelLeica SR GSD
Laser Wavelengths405 nm, 488 nm, 532 nm, 642 nm
Laser Power300–1000 mW per line
Lateral Drift Stability<20 nm / 10 min (SuMo Piezo Stage)
Resolution (GSDIM mode)≤20 nm (lateral)
Compatible FluorophoresAlexa Fluor® 488/532/546/647, Rhodamine-6G, Atto 488/532/565/568, YFP, EYFP
Imaging ModesWidefield, TIRF, High-Speed Multichannel Fluorescence, Temperature-Controlled Live-Cell Imaging
Base PlatformLeica DMI6000 B Inverted Microscope with AM TIRF MC System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelSTELLARIS 8 FALCON
Imaging ModalityTime-Correlated Single-Photon Counting (TCSPC)-based Fluorescence Lifetime Imaging (FLIM)
Frame RateUp to 4 fps at 256 × 256 pixels
Spectral ChannelsSimultaneous acquisition across up to 4 spectral detection channels or sequential acquisition across up to 10 channels
FLIM Analysis ModesBiexponential decay fitting, phasor plot analysis, spectral-FLIM unmixing
Software IntegrationFully embedded in Leica LAS X NAVIGATOR and LAS X LITE platforms
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
Instrument TypePoint-Scanning Confocal Microscope
ModelSTELLARIS SpectraPlex
Spectral Unmixing Capacity>15 fluorophores per acquisition
Workflow IntegrationAivia AI-powered analysis platform
ComplianceDesigned for GLP/GMP-aligned spatial biology workflows, compatible with ISO 13485–informed documentation practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
Instrument TypePoint-Scanning Confocal Microscope
ModelSTELLARIS
Detection Range410–850 nm
Excitation SourceWhite Light Laser (WLL), up to 8 simultaneous spectral lines
Detector TechnologyPower HyD hybrid detectors
Core CapabilitiesFluorescence Lifetime Imaging (FLIM), TauSense-based functional contrast, AI-driven rare-event detection (Aivia), 3D optical sectioning, multi-modal integration (STED, DIVE, DLS, FALCON, CARS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
Country of OriginGermany
ModelSTELLARIS DLS
Instrument TypePoint-Scanning Confocal Microscope with Integrated Digital Light Sheet Module
Integration CompatibilitySTELLARIS 5 and STELLARIS 8 platforms
Optical ArchitectureInverted microscope with vertical dual-axis light sheet generation via TwinFlect mirror system
IlluminationScanned Gaussian or top-hat light sheet (405–785 nm excitation range)
DetectionDual sCMOS cameras (optional high-speed or high-sensitivity configuration)
Sample MountingStandard glass-bottom dishes, U-shaped capillaries, FEP tubing, or custom mounting frames (24 × 50 mm rectangular / Ø30 mm circular)
Refractive Index MatchingCompatible with water, glycerol, BABB, Scale, CUBIC, and other clearing media
Software PlatformLAS X LightSheet Wizard with real-time fusion, environmental control module, 3D Visualization, and GLP-compliant audit trail (21 CFR Part 11 ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelLeica SD AF
ConfigurationImport (OEM-manufactured in Germany)
Software PlatformLeica MM AF
Core TechnologyYokogawa CSU-X1 Spinning Disk Unit Integrated with Leica Optical Path and Adaptive Focus Control
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0