- All
- Favorite
- Popular
- Most rated
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM RAPID |
| Milling Step Resolution | 0.5, 1, 10, 100 µm |
| Spindle Speed Range | 300–20,000 rpm |
| Illumination | Long-life LED ring light |
| Display | Integrated LCD control panel |
| Dust Extraction | Built-in vacuum-compatible dust removal system |
| Sample Holder Options | Single-sample stage and multi-sample stage |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM ACE600 |
| Vacuum Level | 2 × 10⁻⁶ mbar |
| Pumping System | Diaphragm Pump + Turbo Molecular Pump (Oil-Free) |
| Thickness Control | Quartz Crystal Monitor (Resolution: 0.1 nm) |
| Sputtering Current Range | 0–150 mA |
| Chamber Dimensions | 200 mm (W) × 150 mm (D) × 195 mm (H) |
| Sample Stage | Motorized Rotation + Adjustable Working Distance (30–100 mm) |
| Coating Modes | Ion Sputtering, Carbon Filament Evaporation, Carbon Rod (Resistive) Evaporation, Electron Beam Evaporation, Dual-Source Configurations (e.g., Sputter + E-beam), Glow Discharge (Optional) |
| Compatibility | EM VCT100 Cryo-Transfer System |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | EM TIC 3X |
| Application | Research Use Only |
| Sample Throughput | Up to 3 specimens simultaneously |
| Beam Configuration | Three independently adjustable argon ion beams |
| Operating Temperature Range | Ambient to –120 °C (with optional cryo stage) |
| Compatible Interfaces | VCT vacuum transfer docking station, EM ACE600/ACE900 coaters, SEM systems |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM ACE900 |
| Application | Cryo-SEM & TEM Sample Preparation |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Vacuum System | Dual-chamber with Load-Lock Transfer |
| Coating | Electron Beam Evaporation for Carbon/Metal Replicas |
| Compatibility | Integrated with Leica EM VCT500 Cryo-Transfer System |
| Environmental Certification | DIN EN ISO 14001 |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EM TXP |
| Price Range | USD 105,000 – 132,000 |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | Leica EM TIC 3X |
| Application | Research Use Only |
| Sample Throughput | Up to 3 specimens simultaneously |
| Beam Configuration | Three independently adjustable argon ion beams |
| Operating Temperature Range | Ambient to –120 °C (with optional cryo stage) |
| Compatible Interfaces | VCT vacuum transfer docking station for cryo-SEM and coating systems (e.g., EM ACE600/ACE900) |
| Mounting Flexibility | Interchangeable stages — Standard, Multi-Sample, Rotating, Cryo-Cooling, and VCT Docking |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | UC Enuity |
| Type | Ultramicrotome for Electron Microscopy Sample Preparation |
| Temperature Control | Integrated Cryo Chamber with Precise Thermal Regulation (Room Temp to −160 °C) |
| Automation | Auto-alignment of Block Face and Knife, Automated Trimming, Fluorescence-Guided Targeting |
| Compatibility | Diamond/Knife Knives, Glass Knives, Silicon Wafers & EM Grids |
| Ergonomics | Fully Adjustable Stereo Microscope Height & Angle, Padded Arm Supports, UV-Blocking Safety Shield |
| Connectivity | RemoteCare™ Diagnostic Platform with Real-time Parameter Monitoring & Error Code Reporting |
| Compliance | Designed for GLP/GMP-adjacent workflows |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM KMR3 |
| Principle | Balanced Fracture Method |
| Cutting Wheel Material | Tungsten Carbide |
| Adjustable Cutting Pressure | 5-step calibrated scale |
| Fracture Angle | 45° |
| Fracture Pressure Control | Calibrated rotary knob with auto-reset |
| Knife Tray | Drawer-type, tool-free access |
| Compatible Glass Rod Diameters | 6.4 mm, 8 mm, 10 mm |
| Support Mechanism | Precision-ground stainless steel hemispherical fulcrum |
| Repeatability | High (engineered for consistent edge geometry and minimal micro-chipping) |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM AFS2 |
| Temperature Range | –140 °C to +70 °C (precisely controlled) |
| Liquid Nitrogen Capacity | 35 L (supports up to 5 days of continuous operation) |
| Deep Freeze Mode | < –140 °C for cryo-transfer |
| TF (Trace-free) Mode | Active O₂/H₂O removal |
| UV Polymerization | Integrated LED UV source (365 nm) |
| User Storage | 10 user profiles, 99 programs per user |
| Interface | Full-color graphical touchscreen with mouse control |
| Safety | Built-in exhaust system for hazardous solvent vapors |
| Optional Module | Leica EM FSP Fluid Service Processor (automated reagent dispensing, dilution, exchange, and UV polymerization) |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM AC20 |
| Capacity | 20 grids per cycle |
| Reagent Consumption | ~6 mL per cycle (uranyl acetate + lead citrate) |
| Predefined Programs | 10 staining + 2 cleaning protocols |
| Temperature Control Range | 20–60 °C |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM TP |
| Temperature Control Range | +4 °C to +60 °C |
| Sample Capacity | 56 (EM mode), 16 (LM mode), or 168 (3-basket EM mode) |
| Reagent Volume per Step | 10 mL (EM), 50 mL (LM or 3-basket EM) |
| Agitation Amplitude | 6 mm |
| Frequency | 0, 0.25, 0.5, 1, 2, 3 Hz |
| Programmable Steps | Up to 99 protocols stored |
| Reagent Library Capacity | 200 entries |
| Delayed Start/End | Yes |
| Display | LCD, 20×4 character |
| Touchscreen Interface | Integrated |
| Pre-cooling/Pre-heating (EM mode) | Yes |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM ICE |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Sample Capacity | 9 consecutive specimens (3 positions × up to 3 specimens each) |
| Light Stimulation | Integrated LED modules (450 nm, 380 nm, 523 nm, 660 nm, 597 nm) |
| Stimulus-to-Freeze Delay | Millisecond-precise synchronization |
| LN₂ Consumption | ~30 L/day (system-wide, including standby cooling) |
| Environmental Certification | DIN EN ISO 14001 |
| Software Control | Fully automated workflow with audit-trail logging |
| Upgrade Path | Field-upgradable light stimulation and environmental modules (e.g., stage heating, chamber temperature control) |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM ACE200 |
| Vacuum Level | 7 × 10⁻³ mbar |
| Sputtering Current Range | 0–150 mA |
| Sample Chamber Dimensions | 140 mm (W) × 145 mm (D) × 150 mm (H) |
| Working Distance Adjustment | 30–100 mm |
| Carbon Evaporation Mode | Pulsed, Precise Thickness Control |
| Optional Quartz Crystal Thickness Monitor | ±0.1 nm resolution |
| Optional Glow Discharge Function | For hydrophilization of TEM grids |
| Control Interface | Full-touch LCD panel with automated vacuum/pumping/coating/venting sequence |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EM GP2 |
| Pricing | Available Upon Request |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | QWin |
| Version Variants | QWin Runner, QWin Lite, QWin Plus, QWin Std, QWin Pro |
| Software Architecture | QUIPS-based modular platform |
| Microscope Integration | Full compatibility with Leica motorized microscopes and digital cameras |
| Pixel Resolution Support | Optimized for >1 MP imaging systems |
| Regulatory Context | Designed to support GLP/GMP-compliant workflows with audit-trail-ready operation (via optional modules) |
| Data Export | TIFF, BMP, JPEG, PNG, CSV, XML |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM CPD300 |
| Sample Chamber Volume | 175 mL |
| Control Interface | Touchscreen |
| CO₂ Consumption | Reduced via proprietary filler material |
| Safety Features | Integrated waste liquid separation, software-controlled venting interlock |
| Automation Level | Fully automated critical point drying cycle |
| Compliance | Designed for GLP-compliant SEM sample preparation workflows |
| Brand | Leica |
|---|---|
| Origin | Austria |
| Model | EM VCT500 |
| Application | Cryogenic Sample Transfer for Electron Microscopy |
| Compatibility | Cryo-SEM, Cryo-TEM, Cryo-CLEM, FIB-SEM, High-Pressure Freezing (HPF), Cryo-Ultramicrotomy |
| Cooling Mode | Active Liquid Nitrogen (LN₂) Cooling |
| Transfer Environment | Ultra-High Vacuum (UHV) or Controlled Atmosphere (e.g., N₂, Ar) |
| Interface Standard | ISO-KF 40 / CF 63 Flange Compatible |
| Temperature Monitoring | Integrated Pt100 Sensor with Real-Time Readout |
| Vacuum Monitoring | Integrated Pirani + Cold Cathode Gauge |
| Sample Stage Options | Three Standard Carriers (Gatan 626, EMGrid, Leica EM AutoGrid) |
| Customization | OEM Integration Support, Multi-Port Valve Manifolds, LN₂ Auto-Refill Interface |
Show next