Empowering Scientific Discovery

Leica Microsystems (Shanghai) Trading Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM RAPID
Milling Step Resolution0.5, 1, 10, 100 µm
Spindle Speed Range300–20,000 rpm
IlluminationLong-life LED ring light
DisplayIntegrated LCD control panel
Dust ExtractionBuilt-in vacuum-compatible dust removal system
Sample Holder OptionsSingle-sample stage and multi-sample stage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM ACE600
Vacuum Level2 × 10⁻⁶ mbar
Pumping SystemDiaphragm Pump + Turbo Molecular Pump (Oil-Free)
Thickness ControlQuartz Crystal Monitor (Resolution: 0.1 nm)
Sputtering Current Range0–150 mA
Chamber Dimensions200 mm (W) × 150 mm (D) × 195 mm (H)
Sample StageMotorized Rotation + Adjustable Working Distance (30–100 mm)
Coating ModesIon Sputtering, Carbon Filament Evaporation, Carbon Rod (Resistive) Evaporation, Electron Beam Evaporation, Dual-Source Configurations (e.g., Sputter + E-beam), Glow Discharge (Optional)
CompatibilityEM VCT100 Cryo-Transfer System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelEM TIC 3X
ApplicationResearch Use Only
Sample ThroughputUp to 3 specimens simultaneously
Beam ConfigurationThree independently adjustable argon ion beams
Operating Temperature RangeAmbient to –120 °C (with optional cryo stage)
Compatible InterfacesVCT vacuum transfer docking station, EM ACE600/ACE900 coaters, SEM systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM ACE900
ApplicationCryo-SEM & TEM Sample Preparation
Cooling MediumLiquid Nitrogen (LN₂)
Vacuum SystemDual-chamber with Load-Lock Transfer
CoatingElectron Beam Evaporation for Carbon/Metal Replicas
CompatibilityIntegrated with Leica EM VCT500 Cryo-Transfer System
Environmental CertificationDIN EN ISO 14001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEM TXP
Price RangeUSD 105,000 – 132,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelLeica EM TIC 3X
ApplicationResearch Use Only
Sample ThroughputUp to 3 specimens simultaneously
Beam ConfigurationThree independently adjustable argon ion beams
Operating Temperature RangeAmbient to –120 °C (with optional cryo stage)
Compatible InterfacesVCT vacuum transfer docking station for cryo-SEM and coating systems (e.g., EM ACE600/ACE900)
Mounting FlexibilityInterchangeable stages — Standard, Multi-Sample, Rotating, Cryo-Cooling, and VCT Docking
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelUC Enuity
TypeUltramicrotome for Electron Microscopy Sample Preparation
Temperature ControlIntegrated Cryo Chamber with Precise Thermal Regulation (Room Temp to −160 °C)
AutomationAuto-alignment of Block Face and Knife, Automated Trimming, Fluorescence-Guided Targeting
CompatibilityDiamond/Knife Knives, Glass Knives, Silicon Wafers & EM Grids
ErgonomicsFully Adjustable Stereo Microscope Height & Angle, Padded Arm Supports, UV-Blocking Safety Shield
ConnectivityRemoteCare™ Diagnostic Platform with Real-time Parameter Monitoring & Error Code Reporting
ComplianceDesigned for GLP/GMP-adjacent workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM KMR3
PrincipleBalanced Fracture Method
Cutting Wheel MaterialTungsten Carbide
Adjustable Cutting Pressure5-step calibrated scale
Fracture Angle45°
Fracture Pressure ControlCalibrated rotary knob with auto-reset
Knife TrayDrawer-type, tool-free access
Compatible Glass Rod Diameters6.4 mm, 8 mm, 10 mm
Support MechanismPrecision-ground stainless steel hemispherical fulcrum
RepeatabilityHigh (engineered for consistent edge geometry and minimal micro-chipping)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM AFS2
Temperature Range–140 °C to +70 °C (precisely controlled)
Liquid Nitrogen Capacity35 L (supports up to 5 days of continuous operation)
Deep Freeze Mode< –140 °C for cryo-transfer
TF (Trace-free) ModeActive O₂/H₂O removal
UV PolymerizationIntegrated LED UV source (365 nm)
User Storage10 user profiles, 99 programs per user
InterfaceFull-color graphical touchscreen with mouse control
SafetyBuilt-in exhaust system for hazardous solvent vapors
Optional ModuleLeica EM FSP Fluid Service Processor (automated reagent dispensing, dilution, exchange, and UV polymerization)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM AC20
Capacity20 grids per cycle
Reagent Consumption~6 mL per cycle (uranyl acetate + lead citrate)
Predefined Programs10 staining + 2 cleaning protocols
Temperature Control Range20–60 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM TP
Temperature Control Range+4 °C to +60 °C
Sample Capacity56 (EM mode), 16 (LM mode), or 168 (3-basket EM mode)
Reagent Volume per Step10 mL (EM), 50 mL (LM or 3-basket EM)
Agitation Amplitude6 mm
Frequency0, 0.25, 0.5, 1, 2, 3 Hz
Programmable StepsUp to 99 protocols stored
Reagent Library Capacity200 entries
Delayed Start/EndYes
DisplayLCD, 20×4 character
Touchscreen InterfaceIntegrated
Pre-cooling/Pre-heating (EM mode)Yes
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM ICE
Cooling MediumLiquid Nitrogen (LN₂)
Sample Capacity9 consecutive specimens (3 positions × up to 3 specimens each)
Light StimulationIntegrated LED modules (450 nm, 380 nm, 523 nm, 660 nm, 597 nm)
Stimulus-to-Freeze DelayMillisecond-precise synchronization
LN₂ Consumption~30 L/day (system-wide, including standby cooling)
Environmental CertificationDIN EN ISO 14001
Software ControlFully automated workflow with audit-trail logging
Upgrade PathField-upgradable light stimulation and environmental modules (e.g., stage heating, chamber temperature control)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM ACE200
Vacuum Level7 × 10⁻³ mbar
Sputtering Current Range0–150 mA
Sample Chamber Dimensions140 mm (W) × 145 mm (D) × 150 mm (H)
Working Distance Adjustment30–100 mm
Carbon Evaporation ModePulsed, Precise Thickness Control
Optional Quartz Crystal Thickness Monitor±0.1 nm resolution
Optional Glow Discharge FunctionFor hydrophilization of TEM grids
Control InterfaceFull-touch LCD panel with automated vacuum/pumping/coating/venting sequence
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEM GP2
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginGermany
ModelQWin
Version VariantsQWin Runner, QWin Lite, QWin Plus, QWin Std, QWin Pro
Software ArchitectureQUIPS-based modular platform
Microscope IntegrationFull compatibility with Leica motorized microscopes and digital cameras
Pixel Resolution SupportOptimized for >1 MP imaging systems
Regulatory ContextDesigned to support GLP/GMP-compliant workflows with audit-trail-ready operation (via optional modules)
Data ExportTIFF, BMP, JPEG, PNG, CSV, XML
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM CPD300
Sample Chamber Volume175 mL
Control InterfaceTouchscreen
CO₂ ConsumptionReduced via proprietary filler material
Safety FeaturesIntegrated waste liquid separation, software-controlled venting interlock
Automation LevelFully automated critical point drying cycle
ComplianceDesigned for GLP-compliant SEM sample preparation workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
OriginAustria
ModelEM VCT500
ApplicationCryogenic Sample Transfer for Electron Microscopy
CompatibilityCryo-SEM, Cryo-TEM, Cryo-CLEM, FIB-SEM, High-Pressure Freezing (HPF), Cryo-Ultramicrotomy
Cooling ModeActive Liquid Nitrogen (LN₂) Cooling
Transfer EnvironmentUltra-High Vacuum (UHV) or Controlled Atmosphere (e.g., N₂, Ar)
Interface StandardISO-KF 40 / CF 63 Flange Compatible
Temperature MonitoringIntegrated Pt100 Sensor with Real-Time Readout
Vacuum MonitoringIntegrated Pirani + Cold Cathode Gauge
Sample Stage OptionsThree Standard Carriers (Gatan 626, EMGrid, Leica EM AutoGrid)
CustomizationOEM Integration Support, Multi-Port Valve Manifolds, LN₂ Auto-Refill Interface
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0