Life Science Instruments
Filter
Showing 4801–4830 of 7558 results
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE8205 |
| Price Range | USD 1,400 – 7,000 |
| Rotation Speed Range | 4–40 rpm |
| Acceleration Ramp Duration | 30 s – 100 min |
| Time Resolution | 1 s |
| Drum Diameter Options | Species-Specific (Mouse/Rat) |
| Height Extension Kit | 375 mm (Modular, Removable) |
| Fall Detection | Real-Time Optical/Position-Based Triggering |
| Data Output | USB & RS-232 |
| Software | SedCom v3.x (Windows-based Statistical Analysis Suite) |
| Compliance | GLP-Ready Architecture, Audit Trail Capable (FDA 21 CFR Part 11 Optional Configuration) |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model Variants | LE8205, LE8305, LE8355, LE8505 |
| Control Interface | Touchscreen GUI |
| Rotation Modes | Constant Speed (4–40 rpm) and Linear Acceleration (programmable ramp: 30 s to 10 min, 1 s increment) |
| Animal Compatibility | Mice and Rats (with optional rat extension hood for LE8305/LE8355/LE8505) |
| Data Output | Fall latency (s), rotational speed at fall (rpm), per-channel timestamped trials |
| Compliance | CE-marked, GLP-ready architecture, FDA 21 CFR Part 11–compatible with SEDACOM software |
| Warranty | 2 years |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE830 |
| Chamber Dimensions | 16 × 25 × 450 px (W × D × H) |
| Floor Configuration | Four identical stainless steel plates (8 × 275 px each), 4 mm inter-plate gap |
| Stimulus Type | Square-wave current |
| Current Range | 0–3 mA |
| Pulse Duration | 1–10 s |
| Stimulus Trigger | Footswitch-activated |
| Output Metric | Number of plate crossings (i.e., shocks delivered per 60 s) |
| Construction | White opaque plastic walls, transparent acrylic lid, stainless steel floor plates |
| Intended Species | Mus musculus (adult mice) |
| Application Domain | Preclinical anxiety phenotyping and anxiolytic drug screening |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE870 (Rat), LE872 (Mouse) |
| Price | USD 13,500 (FOB) |
| Power Supply | 110–220 V AC, 50/60 Hz |
| Construction Materials | Acrylic (PMMA), Anodized Aluminum, Stainless Steel |
| Animal Compatibility | Mice (min. 10 g), Rats (min. 40 g) |
| Chamber Dimensions (White/Black) | Mouse — 250 × 250 × 240 mm / 195 × 108 × 120 mm |
| Stimulus Delivery | Programmable DC current pulse generator (0–2 mA, adjustable step resolution ≤ 0.01 mA) |
| Detection Method | High-precision load-cell-based weight sensing (no optical beams or tilt switches) |
| Software Control | SHUTAVOID v3.2 (supports up to 8 independent chambers via USB interface, no PCI card required) |
| Primary Output Metric | Latency-to-enter black compartment (ms resolution) |
| Application Scope | Short-term & long-term memory assessment, fear-motivated passive avoidance learning, neuropharmacological screening, hippocampal-dependent behavioral phenotyping |
| Brand | RWD |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Panlab LE8700TS Series |
| Price | USD 13,500 (approx.) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE8700TS |
| Price Range | USD 14,000–70,000 |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Panlab LE8815 (45×45 cm, 2.5 cm beam spacing) / LE8816 (25×25 cm, 1.3 cm beam spacing) |
| Control Unit | LE8825 (supports up to 2 IR frames) |
| Data Logger Memory | 200 h |
| Communication | RS232 (with CONRS232USB adapter) |
| Software Options | SEDACOM V2.0 (instrument control & data export), ACTITRACK V2.7 (trajectory analysis across up to 32 frames) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE8815 / LE8816 |
| External Dimensions | 450 × 450 × 200 mm or 220 × 220 × 200 mm |
| Infrared Frame Options | 450 × 450 mm (32 sensors, 25 mm spacing) or 250 × 250 mm (32 sensors, 13 mm spacing) |
| IR Wavelength | 950 nm |
| Sampling Frequency | 40 Hz |
| Software | Acti-Track v5.x |
| Max Concurrent Channels | 32 |
| Configurable Zones | Single-animal or dual-animal (split-zone) mode |
| Behavioral Metrics | Distance traveled, velocity profiles (max/min/mean), time-in-zone, zone entries, rearing count & duration, rotation counts, trajectory-based path analysis, nose-poke detection (threshold-defined), ambulation classification (fast/slow/immobility) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE890 (Rat) / LE891 (Mouse) |
| Chamber Configuration | Three-compartment (Black–Gray–White) |
| Detection Method | Dual-mode (Video-based via SMART 3.0+CPP module OR Load-cell-based gravity sensing via PPCwin software) |
| Max Concurrent Units | 8 chambers per PC |
| Rat Chamber Dimensions | 300 × 300 × 340 mm (L×W×H) |
| Passage | 80 × 100 × 340 mm |
| Door Opening | 100 × 140 mm |
| Mouse Chamber Dimensions | 100 × 130 × 130 mm (L×W×H) |
| Passage | 72 × 72 × 130 mm |
| Door Opening | 60 × 60 mm |
| Wall Material | Optical-grade acrylic |
| Wall Finish | Matte black or high-gloss white |
| Floor Texture Options | Smooth or rough (tactile cue) |
| Software | SMART 3.0 Behavioral Tracking Suite with CPP Module (video mode) OR PPCwin CPP Acquisition & Analysis Software (load-cell mode) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | LE902 |
| Price Range | USD 1,400 – 7,000 |
| Sensor Range | 0–20 N (0–2000 g) |
| Accuracy | ±0.1% FS |
| Resolution | 0.1 g |
| Sampling Rate | 1000 Hz |
| Display | LED with dual-mode readout (peak force or release time) |
| Data Storage | Internal memory for 100 measurements |
| Interface | RS-232 |
| Grid Material | Stainless steel |
| Power | AC adapter or optional rechargeable battery |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Panlab LE902 |
| Price | USD 13,800 (FOB) |
| Sensor Resolution | Adjustable from 4 to 36 segments per full rotation |
| Bidirectional Detection | Left-rotation and right-rotation counted independently |
| Data Output | TTL-compatible digital signal |
| Software | SeDaCom V2.0 (optional, requires separate license) |
| Container Options | Bowl (Ø400 mm × H200 mm) or Cylinder (Ø400 mm × H300 mm) |
| Mounting | Adjustable soft-loop tether with low-torque swivel interface |
| Counter Unit | LE902CC76-0242 Dual-Channel Rotational Counter (L/R) or LE380676-0243 Programmable MultiCounter (up to 15 independent rotational inputs) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE904 (rat), LE905 (mouse) |
| Wheel Position | External |
| Cage Material | Stainless Steel |
| Time Resolution | 0.01 s |
| Angular Resolution | 30° per detection |
| Sampling Interval | Configurable (e.g., 10 s) |
| Max Simultaneous Cages | 30 |
| Data Export Format | Excel-compatible CSV |
| Compliance | GLP-supporting data audit trail (software-configurable) |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE916 (Mouse), LE918 (Rat) |
| Price Range | USD 13,500 – 68,000 |
| Max Channel Capacity | 8 units |
| Stimulus Modalities | Auditory (programmable tone), Visual (LED light), Aversive (constant-current foot shock) |
| Detection Method | Dual-load-cell weight sensing (no optical or tilt-based artifacts) |
| Interface | USB 2.0, no internal PCI/PCIe card required |
| Compliance | Designed for GLP-compliant behavioral labs |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE916 (Rat) / LE918 (Mouse) |
| Sample Capacity | Single-animal chamber |
| Stimulus Modalities | Auditory (tone/noise), Visual (LED light), Electrical (foot shock, adjustable voltage/current), Mechanical (automated guillotine door) |
| Detection Method | Dual independent load-cell-based gravimetric sensing (left/right compartment) |
| Software | ShutAvoid v3.x (Windows-based, real-time monitoring & offline analysis) |
| Compliance | Designed for GLP-compliant behavioral phenotyping |
| Accessories | Motorized升降 door module, white chamber insert kit, acoustically insulated enclosure with ventilation fan and ambient LED lighting |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | MAZESOFT-8 |
| Hardware Interface | PCI-7200 I/O board required |
| Licensing | USB hardware key (dongle) |
| Data Output | Excel-compatible CSV format |
| Experimental Zone Definition | 17 detection zones (1 central hub + 8 arms × 2 segments: proximal & distal) |
| Sensor Input | TTL-compatible photobeam sensors (8 arms × 2 beams/arm) |
| Control Output | Relay-driven gate actuation (manual or software-triggered) |
| Documentation | Digital user manual (ISO-compliant installation media) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE1002 / LE1005 |
| Construction | Stainless steel, aluminum alloy, and methyl methacrylate |
| Dimensions (Base) | 400 × 360 × 35 mm |
| Mouse Chamber | 200 × 200 × 250 mm |
| Rat Chamber | 250 × 250 × 250 mm |
| Scalability | 1–8 chambers standard, upgradable to 16 |
| Connectivity | USB-based hardware interface (no PCI card required) |
| Software Platform | Packwin 2.0 |
| Module Options | Lever press, nose-poke, food/water delivery, auditory stimuli (pure tone & broadband noise), visual stimuli (LED lighting), foot shock, intracranial/IV drug infusion ports, transparent access door, overhead camera port, interchangeable floor/wall panels (material & color configurable) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Range | Customizable (225–500 cm diameter) |
| Price Range | USD 6,800 – 13,600 |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Custom-Configurable (Contact for Specification) |
| Pricing | Available Upon Request |
| Construction Material | Polypropylene |
| Temperature Control Range | 22–32 °C |
| Platform Options | Two removable platforms (Ø80 mm and Ø110 mm) |
| Water Level Control | Electromechanical valve with auto-shutoff at preset height |
| Integrated Components | Submersible circulation pump, digital thermostat, precision liquid-level sensor, dual-fuse safety circuit |
| Mobility | Four swivel casters with locking brakes |
| Compliance | Designed to meet OECD TG 426, NIH Guide for Care and Use of Laboratory Animals, and institutional IACUC protocol requirements |
| Brand | Panlab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Oxylet |
| Price Range | USD 25,000 – 65,000 |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Oxylet Pro |
| Pricing | Upon Request |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Radial |
| Pricing | Available Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE1002 / LE1005 |
| Chamber Base Dimensions | 400 × 360 × 35 mm |
| Mouse Operant Chamber | 200 × 200 × 250 mm |
| Rat Operant Chamber | 250 × 250 × 250 mm |
| Construction Materials | Stainless Steel, Aluminum Alloy, Acrylic (Methyl Methacrylate) |
| Scalability | 1–8 chambers standard |
| Control Interface | USB-connected PC software |
| Modular Configurability | Interchangeable rat/mouse hardware kits via tool-free component removal |
| Integrated Components | Programmable syringe pump interface, lever actuator, photobeam sensors, LED/auditory stimulus outputs, TTL-compatible I/O ports |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Compatible Models | All Panlab Hardware Platforms |
| Price Range | USD $6,800 – $13,600 (FOB US) |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | SMART V3.0 |
| Operating System | Windows 7 (32/64-bit) |
| Modular Architecture | CS, WM, PM, OF, CPP, TY, FST, MA, GA, SI, TW, IO |
| Max Simultaneous Zones | 100 |
| Supported Species | Rodents (mice, rats), Zebrafish (larvae), Social Cohorts (up to 8 subjects) |
| Video Input Compatibility | USB, FireWire, Analog (via CONVANAUSB converter), Built-in Webcam |
| Real-time Analysis | Yes |
| Data Export Format | CSV, Excel-compatible, Graphical Plots (Line, Bar, Heatmap) |
| Compliance | GLP-supportive metadata logging, FDA 21 CFR Part 11–ready audit trail (with optional secure user authentication module) |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Thermal Gradient Test |
| Temperature Range | 15–55 °C |
| Gradient Length | 312.5 cm |
| Max Zones | 20 independent isothermal segments |
| Animal Capacity | 1 rat OR 2 mice |
| Position Tracking | Real-time locomotion mapping via synchronized video |
| Data Output | Dwell time per zone, total path length, latency to preferred zone, thermal preference curve |
| Compliance | Designed for GLP-compliant behavioral phenotyping |
| Brand | Parvo Medics |
|---|---|
| Origin | USA |
| Model | True One2400 |
| O₂ Analysis Range | 0–100% or 0–25% |
| O₂ Accuracy | ±0.02% |
| O₂ Response Time | 200 ms (21% → 16% in 4 L mixing chamber) |
| CO₂ Analysis Method | NDIR (Non-Dispersive Infrared) |
| CO₂ Range | 0–15% |
| CO₂ Accuracy | ±0.03% (for 0–10% CO₂) |
| CO₂ Response Time | 100 ms |
| Flow Measurement Accuracy | ±0.5% |
| Flow Range | 0–800 L/min |
| Calibration | Dual-stage (3 L syringe, 16% O₂ / 4% CO₂ gas mixture) |
| Operating Temperature | 14–30 °C |
| Relative Humidity | 20–80% RH |
| Warm-up Time | 30 min |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Software Platform | Windows XP–compatible proprietary metabolic analysis suite |
| Data Export | Native Excel (.xls) output |
| Brand | PBI |
|---|---|
| Origin | USA |
| Model | Barocycler® 2320EXT |
| Pressure Range | Ambient (14.7 psi) to 45,000 psi (310 MPa) |
| Temperature Control Range | 4 °C to 95 °C |
| Sample Mass Capacity | 0.2–3 mg |
| Throughput | Up to 16 samples per run |
| Actuation Medium | Deionized Water |
| Input Gas Requirement | 110 psi compressed air or nitrogen |
| Interface | Touchscreen with real-time pressure/temperature curve display |
| Pressure Profiles | Pulse, Ramp, Waveform, Static |
| Data Logging | Full parameter recording, method storage, exportable CSV logs |
| Compliance | Designed for GLP-compliant workflows |
| Brand | PCRmax |
|---|---|
| Origin | United Kingdom |
| Model | AC-1 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL) or 384-well module (field-replaceable) |
| Max Heating/Cooling Rate | 3.4 °C/s |
| Temperature Accuracy | ±0.25 °C |
| Inter-well Temperature Uniformity | ±0.3 °C |
| Temperature Range | 4–100 °C |
| Gradient Range | 10–100 °C |
| Gradient Span | 1–29 °C |
| Gradient Channels | 12 independent temperature zones |
| Heat Lid Temperature | 35–115 °C (adjustable, manually pressure-controlled) |
| Heat Lid Uniformity | ±5 °C |
| Heat Lid Preheating Time | <2 min |
| Display | 7" 1080P full-color LCD touchscreen |
| OS | Embedded Android-based firmware |
| Onboard Program Storage | ≥1,000 protocols |
| USB Expansion Support | Yes (USB-A & USB-B) |
| Power Consumption (30-cycle run) | 0.3 kWh |
| Dimensions (W×D×H) | 200 × 260 × 430 mm |
| Rated Power | 425 W |
| Noise Level | <50 dB(A) |
| Brand | PCRmax |
|---|---|
| Origin | United Kingdom |
| Model | AC-2 |
| Sample Capacity | Two independent blocks (configurable as two 96-well, two 384-well, or mixed 96/384 modules) |
| Max Heating Rate | 3.4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Block Uniformity | ±0.3 °C |
| Temperature Range | 4–100 °C |
| Gradient Range | 10–100 °C |
| Gradient Span | 1–29 °C |
| Gradient Steps | 12 distinct temperatures with identical hold times |
| Thermal Lid | Adjustable manual pressure, 35–115 °C (or off), uniformity ±5 °C, preheat time <2 min |
| Cooling Method | Peltier-based semiconductor |
| Programmable Cycles | Up to 99 |
| Onboard Storage | ≥1000 protocols |
| Interface | 1× USB-A, 1× USB-B |
| Power | 900 W |
| Dimensions (W×D×H) | 470 × 535 × 330 mm |
| Noise Level | <50 dB (per module) |
| Brand | PCRmax |
|---|---|
| Origin | United Kingdom |
| Model | AC-4 |
| Sample Capacity | 4 × 96-well or 4 × 384-well blocks (configurable combinations) |
| Max Heating Rate | 3.4°C/sec |
| Temperature Accuracy | ±0.1°C |
| Block Uniformity | ±0.3°C |
| Temperature Range | 4–100°C |
| Gradient Range | 10–100°C |
| Gradient Span | 1–29°C |
| Thermal Lid Temp | 35–115°C |
| Thermal Lid Uniformity | ±5°C |
| Thermal Lid Preheat Time | <2 min |
| Max Cycles per Program | 99 |
| Onboard Storage | ≥1,000 protocols |
| Display | 10" 1080P color LCD touchscreen |
| OS | Android-based embedded system |
| Power | 1600 W |
| Dimensions (W×D×H) | 700 × 535 × 335 mm |
| Noise Level | <50 dB (per module) |