| Brand | Panasonic |
|---|---|
| Origin | Liaoning, China |
| Model | MPR-162DCN-PC, MPR-312DCN-PC |
| Temperature Range | 2°C to 14°C (ambient: −5°C to 35°C) |
| Effective Volume | 158 L |
| Internal Dimensions | 720 × 300 × 725 mm (W×D×H) |
| External Dimensions | 800 × 450(532) × 1090 mm (W×D×H) |
| Cooling Method | Hermetic Reciprocating Compressor |
| Refrigerant | R134a |
| Rated Input Power | 173 W |
| Net Weight | 67 kg |
| Exterior Material | Powder-Coated Steel |
| Interior Material | Stainless Steel |
| Door Type | Single Sliding Double-Glazed Door with Heat-Reflective Film |
| Safety Features | High/Low Temperature Alarm, Door-Ajar Alert, Over-Temperature Cut-Off, Digital Temperature Display with Flashing Alert |
| Compressor Output | 90 W |
| Standard Accessories | LED Interior Light, 2 Adjustable Stainless Steel Shelves, Key Set, MTR-0621LH Monitoring Cable |
| Brand | Panasonic |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MPR-210 |
| Temperature Range | 2°C to 8°C (ambient: 5–30°C) |
| Effective Volume | 291 L |
| Internal Dimensions | 570 × 498 × 1070 mm |
| External Dimensions | 660 × 650 × 1635 mm |
| Cooling Method | Forced-air convection cooling |
| Compressor Type | Hermetic |
| Refrigerant | R134a (environmentally compliant) |
| Power Consumption | 262 W |
| Net Weight | 107 kg |
| Door Type | Electrically heated double-glazed door with low-emissivity thermal-reflective film |
| Safety Features | High/low temperature alarm, door-open alarm (>60 s), sensor fault detection, condenser blockage & overheating monitoring |
| Interior Material | Powder-coated steel |
| Exterior Material | Powder-coated steel |
| Standard Accessories | 1 LED interior light, 1 set of keys, 4 adjustable wire shelves |
| Port | One Φ32 mm temperature probe access port (left side) |
| Brand | Panasonic |
|---|---|
| Origin | China (Liaoning Province) |
| Model | MPR-210, MPR-310, MPR-510, MPR-710, MPR-1010 |
| Temperature Range | 2–8°C (ambient 5–35°C) |
| Net Capacity | 210 L (MPR-210), 387 L (MPR-310), 536 L (MPR-510), 732 L (MPR-710), 1080 L (MPR-1010) |
| External Dimensions (W×D×H) | 660×650×1635 mm (MPR-210) |
| Internal Dimensions (W×D×H) | 570×498×1070 mm (MPR-210) |
| Cooling Method | Forced-air convection with dual evaporator system |
| Compressor | Hermetic scroll-type |
| Refrigerant | R134a (MPR-210/310), R404A (MPR-510/710/1010) |
| Power Consumption | 262 W (MPR-210) |
| Safety Features | High/Low temperature alarm, door ajar alarm (1 min delay), sensor fault detection, condenser clog & overheat monitoring (MPR-510 and above) |
| Construction | Powder-coated steel exterior and interior |
| Door | Electrically heated anti-fog glass with thermal reflective coating |
| Standard Accessories | LED interior lighting, lockable door with key set, adjustable wire shelving (4–10 tiers depending on model) |
| Brand | Panasonic |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MPR-440F |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Low-Temperature Refrigerator (≥ −60 °C) |
| Configuration | Upright |
| Total Effective Volume | 444 L (Refrigerator Compartment: 218 L |
| Freezer Compartment | 226 L) |
| Interior Dimensions (mm) | Refrigerator: 649 × 566 × 600 |
| Freezer | 649 × 614 × 600 |
| Exterior Dimensions (mm) | 793 × 770 × 1806 |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 320 W |
| Refrigerants | R134a (refrigerator), R404A (freezer) |
| Safety Features | High/Low Temperature Alarm, Door-Open Alarm, Sensor Fault Detection, Overheat Protection, Setpoint Deviation Monitoring, Self-Diagnostic Function |
| Compliance | Designed to support GLP-compliant storage workflows |
| Brand | Panasonic (formerly Sanyo) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MPR-511 |
| Price Range | USD 4,200 – 7,000 |
| Instrument Type | Laboratory Refrigerated Cabinet (2–8°C) |
| Configuration | Upright |
| Effective Volume | 536 L |
| External Dimensions (W×D×H) | 900 × 668 × 1950 mm |
| Internal Dimensions (W×D×H) | 820 × 523 × 1375 mm |
| Net Weight | 155 kg |
| Rated Input Power | 340 W |
| Temperature Range | 2–8°C (ambient 5–35°C) |
| Compressor | Hitachi Original Imported |
| Refrigerant | R404A (environmentally compliant) |
| Door | Dual sliding tempered glass doors with low-emissivity heat-reflective film |
| Interior Lighting | LED (1 unit) |
| Shelving | 5-tier adjustable wire shelves (10 total) |
| Control System | Microprocessor-based digital temperature controller with 0.1°C resolution |
| Display | Password-protected digital LCD |
| Communication | MODBUS RTU output |
| Optional Data Logging | USB export interface |
| Safety Features | Dual-stage audible/visual alarms for high/low temperature, door ajar, power failure, compressor fault, sensor failure, condenser fan degradation, battery status, and remote alarm relay output |
| Cooling System | Forced-air circulation with 4 imported DC evaporator fans and 4 DC condenser fans |
| Defrost Method | Intelligent cyclic defrost with continuous temperature maintenance |
| Condensate Management | Auto-evaporation system |
| Power Supply | Single-phase 220 V / 50 Hz (198–242 V wide-range tolerance) |
| Test Port | One Ø32 mm port on left side |
| Mobility | Casters with locking mechanism |
| Exterior Material | Electrogalvanized steel with polyester powder coating |
| Interior Material | Electrogalvanized steel with polyester powder coating |
| Certification | China NMPA Medical Device Registration Certificate, ISO 9001, ISO 14001, ISO 13485, OHSAS 18001 |
| Brand | Panasonic (formerly Sanyo) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MPR-511 (Alphavita / Songyang Bio) |
| Instrument Type | Low-Temperature Refrigerator (> −60 °C) |
| Configuration | Upright |
| Effective Volume | 536 L |
| External Dimensions (W×D×H) | 900 × 668 × 1950 mm |
| Temperature Range | 2–8 °C (ambient: 5–35 °C) |
| Net Weight | 155 kg |
| Rated Power Input | 340 W |
| Cabinet Material | Electrogalvanized Steel with Polyester Powder Coating |
| Door | Dual Sliding Glass Doors with Heat-Reflective Film & Integrated Lock |
| Compressor | Hitachi Original Imported |
| Refrigerant | R404A (Environmentally Compliant) |
| Power Supply | 220 V / 50 Hz (198–242 V Wide-Range Operation) |
| Control System | Microprocessor-Based Digital Temperature Controller (0.1 °C Resolution), Password-Protected Display, MODBUS RTU Communication Interface, Optional USB Data Logging |
| Cooling System | Forced-Air Circulation via 4 Imported DC Evaporator Fans & 4 DC Condenser Fans |
| Defrost Method | Intelligent Cycle Defrost (Maintains Setpoint During Defrost) |
| Safety Features | Dual-Stage Temperature Alarm (High/Low), Door-Open Alarm, Power Failure Alarm, Compressor Protection, Sensor Fault Detection, Battery Life Monitoring, Condenser Fan Life Monitoring, Remote Alarm Output |
| Accessories | LED Interior Lighting (1 unit), 5-Tier Adjustable Wire Shelving (10 shelves total), Key Set (1), 32 mm Test Port (Left Side), Casters with Locking Brakes |
| Certifications | CNFDA Medical Device Registration Certificate, ISO 13485:2016, ISO 9001:2015, ISO 14001:2015, OHSAS 18001:2007 |
| Brand | Panasonic |
|---|---|
| Model Series | SDF-C230, SDF-C430, SDF-C630 |
| Temperature Range | −20 °C to −35 °C (SDF-C230/C430) |
| Effective Volume | 280 L / 425 L / 635 L |
| Internal Dimensions (W×D×H) | 780×550×733 mm / 1140×550×733 mm / 1674×620×663 mm |
| External Dimensions (W×D×H) | 924×694×931 mm / 1284×694×931 mm / 1800×800×848 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Input Power | 210 W / 240 W / 365 W |
| Refrigerant | R404A |
| Compressor | Hermetic Sealed |
| Door Type | Top-opening Single Door |
| Locking Mechanism | Mechanical Door Lock |
| Safety Alarms | Adjustable High/Low Temperature Alarm, Condenser Temperature Anomaly Alarm |
| Insulation | High-Density Polyurethane Foam |
| Exterior Material | Electro-Galvanized Steel with Polyester Powder Coating |
| Interior Material | Electro-Galvanized Steel (C230/C430) / Embossed Aluminum (C630) |
| Net Weight | 85 kg / 95 kg / 105 kg |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 8.5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Thermal Control Technology | Marlow Semiconductor-based Peltier Modules |
| Optical Detection Architecture | Integrated Waveguide-Based Fluorescence Detection |
| Software Platform | CqMAN Quantitative Analysis Suite (Multi-language: English & Chinese) |
| Consumable Compatibility | Automated pressure-assisted sealing for both 0.1 mL and 0.2 mL tube formats |
| Automation Interface | RS-232/USB/Ethernet |
| Brand | Panlab / Harvard Apparatus |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Touch-Test™ Electronic Von Frey Anesthesiometer |
| Measurement Range | 0–500 g (±20% overload tolerance) |
| Display Resolution | 0.1 g |
| Measurement Accuracy | ±0.2 g |
| Operating Temperature | 0–50 °C |
| Statistical Capacity | Mean, Standard Deviation, Coefficient of Variation (up to 100 animal records) |
| Compliance | ISO 9001 certified, EMC compliant |
| Interface | RS-232 serial output, optional footswitch control |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | BIO-TST4 |
| Sensor Type | Precision Load Cell (Gravity-Based Force Transduction) |
| Output Parameters | Immobility Time (s), Immobility Ratio (%), Mean Struggling Force (mN), Energy Expenditure (mJ), Threshold-Adjustable Immobility Detection |
| Connectivity | USB 2.0 |
| Max Concurrent Units per PC | 6 |
| Animal Capacity | 3–6 mice (configurable 3×2 array) |
| Housing Material | Black-and-White Acrylic Enclosure with Stainless Steel Hooks |
| Optional Integration | SMART 3.0 Video Analysis Module (add-on) |
| Data Export | CSV/Excel-compatible format |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE862 / LE865 |
| Stimulus Range | 0.1–2 mA (LE10025 Electrode Stimulator), Pulse Duration: 0.1–10 s |
| Detection Resolution | Single-lick resolution via patented sipper-tube sensor |
| Cage Capacity | Up to 32 cages per PC (with PACKWIN software) |
| Onboard Memory | 99 drinking events per detector |
| Compliance | Designed for GLP-aligned behavioral phenotyping workflows |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Panlab Drinko-Lick |
| Price | USD 13,800 (approx.) |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Dynamic Weight Bearing System |
| Animal Compatibility | Mice (15–50 g), Rats (150–500 g) |
| Force Resolution | 0.2 g (mice), 0.8 g (rats) |
| Force Accuracy | ±1 g |
| Data Synchronization | Real-time video-embedded force recording via USB |
| Output Format | Native Excel (.xlsx) |
| Compliance | Designed for GLP-aligned preclinical behavioral phenotyping |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LE840 (Rat), LE842 (Mouse), H10-35-EPM (Universal) |
| Dimensions | LE840 — Enclosed Arms: 1000 × 1000 × 500 mm (gray walls) |
| Open Arms | 100 × 450 mm |
| LE842 — Enclosed Arms | 650 × 650 × 150 mm (gray walls) |
| Open Arms | 60 × 295 mm |
| H10-35-EPM — Arm Width | 250 px (≈63.5 mm), Arm Length: 1250 px (≈317.5 mm), Wall Height: 750 px (≈190.5 mm), Platform Height: 1375 px (≈349.3 mm) |
| Material | Cast Methyl Methacrylate (PMMA), Anodized Aluminum Frame |
| Transparent Wall Height | 30 mm (rat), 18 mm (mouse) |
| Tracking Compatibility | Manual Scoring or Video-Based Analysis with SMART 3.0 Software Suite (sold separately) |
| Output Metrics | Position Coordinates, Time Spent per Zone, Total Path Length, Instantaneous & Average Velocity, Arm Entries, Latency to First Entry |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Fear |
| Animal Weight Range | 15–500 g |
| Interface | USB |
| Compliance | GLP-ready data traceability |
| Software Platform | PackWin 2.0 with Startle & Freezing Modules |
| Sensor Type | High-sensitivity load-cell-based motion transducer |
| Configurable Stimulus Outputs | Auditory (broadband noise, tone bursts), Visual (LED flash), and Aversive (foot shock via optional stimulator) |
| Enclosure Options | Acoustic isolation chamber (standard), transparent or opaque test cages |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE810 (mouse), LE812 (rat), LE816 (mouse, automated), LE818 (rat, automated) |
| Chamber Dimensions (mouse) | Light chamber 240 × 250 × 250 mm |
| Chamber Dimensions (rat) | Light chamber 240 × 310 × 310 mm |
| Detection | Load-cell-based position sensing |
| Interface | RS-232 serial communication |
| Software | PPCWIN v3.x (Windows-compatible) |
| Compliance | Designed for GLP-aligned behavioral phenotyping workflows |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE895/6/7/8 |
| Detection Method | Video Tracking (SMART 3.0) or Load-Cell-Based Gravimetric Sensing (PPCWIN) |
| Max Concurrent Units | 8 chambers per PC |
| Rat Chamber Assembly | 88 × 47 × 1125 px (L×W×H) |
| Compartment | 40 × 34 × 1125 px |
| Passage | 25 × 13 × 1125 px |
| Mouse Chamber Assembly | 46 × 27 × 625 px |
| Compartment | 20 × 18 × 625 px |
| Passage | 20 × 7 × 625 px |
| Construction | Optical-grade acrylic |
| Configurable Cues | Interchangeable wall textures/colors, modular floor substrates (tactile/visual), repositionable 3D spatial dividers |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Hot Plate Analgesia Meter |
| Temperature Range | 35–65 °C |
| Temperature Accuracy | ±0.3 °C |
| Timer Resolution | 0.1 s |
| Timer Range | 0–9 min 59 s |
| Compatible Species | Mice and Rats |
| Regulatory Compliance | Designed for GLP-compliant preclinical pain research |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE 7406 |
| Heating Plate Material | Pure Aluminum |
| Heating Plate Dimensions (D × T) | 200 mm × 10 mm |
| Base Dimensions (L × W × H) | 200 mm × 300 mm × 110 mm |
| Cylinder Dimensions (D × H) | 200 mm × 250 mm |
| Temperature Range | 45–62 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Reaction Time Resolution | 0.1 s |
| Input Control | Footswitch-activated timing |
| Data Output | RS-232 serial interface |
| Compliance | CE-marked |
| Optional Software | SeDaCom |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | Hot-Plate Thermal Analgesia Meter |
| Temperature Range | 45–62 °C |
| Temperature Accuracy | ±0.1 °C |
| Timer Resolution | 0.1 s |
| Heating Plate Material | 10 mm Aluminum |
| Safety Protection | Multi-circuit Electronic Over-Temperature Control |
| Interface | Built-in LCD Display + Footswitch Input + SEDACOM Software Connectivity |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | HotCold Plate |
| Temperature Range | -3 °C to +65 °C (ambient 20–25 °C) |
| Temperature Stability | ±0.5 °C (mean, plate surface) |
| Temperature Uniformity | ±0.1 °C under 400 g load |
| Ramp Rate | <10 min from ambient to 4 °C |
| Control Software | BSRamp (custom ramp profiles, time-stamped storage) |
| Compliance | EEC metrological standards for laboratory thermal instrumentation |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE116 |
| Price Range | USD 1,400 – 7,000 |
| Dimensions | 250 × 250 × 250 mm (L×W×H) |
| Animal Weight Range | 15–500 g |
| Acoustic Stimulus Range | 200–10,000 Hz, 60–120 dB |
| Sensor Technology | Precision Load Cell-Based Gravimetric Detection |
| Stimuli Control | Programmable Light, Tone, Foot Shock, Air Puff |
| Max Simultaneous Units | 8 per PC |
| Software Modules | PACKWINCS-FR (Fear Conditioning), PACKWINCS-ST (Startle Reflex) |
| Environmental Configurability | Interchangeable Floor/Wall Panels, Modular Chamber Geometry (Square, Circular, Triangular) |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LE116 |
| Price | USD 14,000 (approx.) |
| Sensor Sensitivity | 10 mg – 2 kg |
| Chamber Dimensions | 250 × 250 × 250 mm (W×D×H) |
| Sound Frequency Range | 200–10,000 Hz |
| Sound Intensity | Up to 120 dB SPL |
| White Noise Range | 60–120 dB SPL |
| Max Channels per PC | 8 |
| Floor Grid Options | 6 mm or 10 mm spacing |
| Construction Materials | Sandwiched acrylic, aluminum alloy, stainless steel |
| Compliance | CE Marked |
| Power Supply | 110/220 V, 50/60 Hz |
| Animal Weight Range | 15–500 g |
| Software | PACKWIN V2.0 with STARTLE and FREEZING modules |
| Optional Hardware | Pneumatic startle (LE119), electric shock generator (LE10026), environmental configuration kits (LE115), species-specific restraints (LE117 series), stimulus interface modules (LE118 / LE1188) |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | LE5001 |
| Pricing | Available Upon Request |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | LE7106 |
| Animal Compatibility | Mice and Rats |
| Stimulus Source | Halogen Heating Lamp |
| Control Interface | Footswitch-Activated Electronic Control Unit |
| Measurement Principle | Radiant Heat–Induced Nocifensive Withdrawal Reflex Timing |
| Compliance | Designed for GLP-aligned preclinical analgesia studies |
| Brand | Panlab |
|---|---|
| Origin | Spain |
| Model | LE7306 |
| Device Type | Electronic Dynamic Pressure Stimulator for Hindpaw Withdrawal Threshold Measurement |
| Compliance Context | Designed for preclinical pain research in accordance with IASP guidelines and standard rodent behavioral assay protocols (e.g., Randall–Selitto test) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | Mexico |
| Model | LE7420 |
| Temperature Range | −3 °C to 65 °C (at ambient 20–25 °C, 50% RH) |
| Temperature Uniformity | < 0.5 °C across plate surface |
| Timing Resolution | 0.1 s |
| Plate Dimensions | 165 × 165 mm |
| Base Dimensions | 305 × 280 × 158 mm |
| Weight | 6.5 kg |
| Included Software | BSRamp Software |
| Optional Software | SeDaCom Data Acquisition Software |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | LE7500 |
| Price Range | USD 1,400 – 7,000 |
| Control Unit Dimensions (W × D × H) | 280 × 280 × 110 mm |
| Stimulus Unit Dimensions (W × D × H) | 230 × 220 × 300 mm |
| Activation | Front-panel keypad or footswitch |
| Resolution | 0.01 mL (3-digit display) |
| Chamber Material | Methyl methacrylate (PMMA) |
| Frame Material | Stainless steel |
| Electrode Material | Platinum |
| Certification | CE-marked |
| Measurement Parameter | Paw volume (displacement-based plethysmography) |
| Interface | RS-232 serial connection to PC |
| Software Control | PC-based acquisition and analysis interface |
| Auto-zero function | Footswitch-triggered |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE7900 |
| Touchscreen Resolution | 0.05 g |
| Averaging Time | 1–300 s |
| Max Load Capacity | 2000 g |
| Controller Dimensions | 17 × 25 × 10 cm |
| Weight Units | g / N / lb |
| Data Storage | 200 entries |
| Animal Compatibility | Mouse, Rat, Rabbit (with optional kit) |
| Software | SeDaCom (Excel export supported) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | LE803 / LE804 |
| Cup Dimensions (LE804) | 10 cm Ø × 25 cm H |
| Cup Dimensions (LE803) | 20 cm Ø × 50 cm H |
| Cup Dimensions (LE803L) | 30 cm Ø × 50 cm H |
| Behavioral Classification | Immobility, Swimming, Climbing |
| Detection Accuracy | <4% error rate |
| Reproducibility | 100% |
| Camera Configuration | Dual-angle (top-down + side-view) |
| Software | SMART v3.x with GLP-compliant data archiving |
| Throughput | Up to 4 rodents simultaneously |