Life Science Instruments
Filter
Showing 1321–1350 of 7558 results
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-7305A |
| Pricing | Available Upon Request |
| Temperature Control Range | Room Temperature to 100 °C |
| Temperature Stability | ±0.1 °C |
| Stirring Time Range | 0–100 minutes |
| Timing Range | 0–99.9 hours |
| Sample Capacity | 4 test positions |
| Data Storage Capacity | 350 test records |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Max. Power Consumption | 1500 W |
| Operating Environment | 5–40 °C, RH <85% |
| Dimensions (L×W×H) | 520 × 330 × 550 mm |
| Net Weight | 23 kg |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Charm EPIC Plus |
| Instrument Type | Fully Automated Microbial Contamination Screening System |
| Throughput | 96 samples per run |
| Detection Principle | ATP Bioluminescence Quantification |
| Incubation Time | 36–48 h (intact-package incubation) |
| Software | EPICLink v5.x with Audit Trail & Data Export |
| Compliance | Designed for GLP/GMP environments |
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Charm Peel Plate Colony Counter |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Semi-Automatic Microbial Enumeration System |
| Detection Throughput | Up to 96 Peel Plate™ assays per hour (based on standard workflow) |
| Compatible Assay Formats | Total Aerobic Count, *E. coli*, Coliforms, Yeast & Mold, Enterobacteriaceae |
| Integrated Camera Resolution | ≥5 MP |
| Display | 6.75-inch diagonal touchscreen LCD |
| Dimensions (W × H × D) | 32.0 × 22.86 × 16.764 cm |
| Weight | 4.54 kg (10 lbs) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Onboard Storage Capacity | 66,000 assay records |
| Data Export Formats | JPEG (raw & processed images), CSV (quantitative results), SQL-compatible database output via Ethernet |
| Input Devices | Wireless keyboard/mouse, optional barcode scanner |
| Calibration Check | Configurable frequency — at startup, after user-defined count intervals, or on-demand |
| User Roles | Dual-tier (Operator + Administrator) with role-based access control (RBAC) |
| Compliance | Designed for GLP-compliant environments |
| Brand | Chart MVE |
|---|---|
| Origin | USA |
| Model | 616 |
| Capacity | Up to 39,000 × 1.2/2.0 mL cryovials |
| Operating Mode | Liquid-phase storage (optional vapor-phase conversion with accessory kit) |
| Neck Opening Diameter | Wide-neck design (≥125 mm typical for 616 class) |
| Static Hold Time | ≥180 days (typical, dependent on ambient conditions and fill level) |
| Dimensions (H × D) | Approx. 1,420 × 760 mm |
| Net Weight | ~180 kg (empty) |
| Optional | Backup battery for temperature monitoring system |
| Brand | Revvity |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Chemagic Prepito-D |
| Automation Level | Dedicated Fully Automatic |
| Batch Throughput | 1–12 samples per run |
| Sample Types Supported | Whole blood, plasma, nasopharyngeal swabs, saliva, tissue homogenates |
| Reagent Dispensing | Integrated precision liquid handler |
| Regulatory Status | China NMPA Filing No. GuoXieBei 20140357 |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiScope 6100 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6 MP |
| Sensor Cooling | −25 °C |
| Bit Depth | 16-bit (65,536 gray levels) |
| Pixel Binning Options | 1×1, 2×2, 3×3, 4×4 |
| Lens | F/0.95 motorized auto-focus lens |
| Transmission Illumination Area | 15 cm × 18 cm |
| Optional Transillumination Sources | UV LED (365 nm or 380 nm), Blue LED (470 nm), White LED |
| Optional Reflective Fluorescence Excitation | Monochromatic LEDs (365, 470, 530, 630, 660, 730 nm) |
| Optional Emission Filters | 460, 525, 585, 690, 715, 810 nm |
| Sample Stage | Dual-layer chemiluminescence stage with white LED reflectance illumination |
| Software | ChemiScope Image Acquisition & Analysis Suite |
| Data Interface | Dual USB 2.0 ports |
| Dimensions (W×D×H) | 435 mm × 395 mm × 700 mm |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiScope 6200 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6 MP |
| Sensor Cooling | −25 °C |
| Bit Depth | 16-bit (65,536 gray levels) |
| Pixel Binning Options | 1×1, 2×2, 3×3, 4×4 |
| Lens | F/0.95 motorized auto-focus lens |
| UV Transilluminator (optional) | 365 nm or 380 nm LED, 21 cm × 26 cm area |
| Blue Light Transilluminator (optional) | 470 nm LED, 21 cm × 26 cm |
| White Light Transilluminator (optional) | LED, 21 cm × 26 cm |
| Reflective Fluorescence Excitation (optional) | 365/470/530/630/660/730 nm LEDs |
| Emission Filters (optional) | 460/525/585/690/715/810 nm |
| Sample Stage | Dual-layer chemiluminescence stage with white LED reflectance illumination |
| Software | ChemiScope Image Acquisition & Analysis Suite |
| Data Interface | Dual USB 3.0 ports |
| Touchscreen | Optional 10.1″ industrial embedded panel PC |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiScope 6200 Touch |
| Imaging Sensor | 6-Megapixel Cooled CCD |
| Light Sources | UV (302 nm), Blue LED (470 nm), White LED Transillumination |
| Lens | Motorized F/0.8 Autofocus Lens |
| Software | CLINX ImageStudio Pro v5.x |
| Compliance | CE, ISO 13485 (Manufacturer QMS), GLP-compliant audit trail & metadata logging |
| Brand | Clinx |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiScope S6 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6.0 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| Lens Aperture | f/0.95 Fixed Focus |
| Integrated Control | 10.1-inch Industrial Touchscreen PC |
| Sample Stage | Motorized Platform |
| Light Source | White Light Reflective Illuminator |
| Brand | Clinx |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiScope S7 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6.0 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD |
| Effective Sensor Resolution | 1440 × 1004 pixels |
| Pixel Size | 96 µm × 96 µm |
| Max Imaging Area | 145 mm × 110 mm |
| Exposure Modes | Auto, Manual, Sequential |
| Exposure Time Range | 0.1 s – 200 s |
| Brand | PACIFICIMAGE |
|---|---|
| Origin | Taiwan |
| Model | Chemlux 600RGBW |
| Instrument Type | Semi-Automatic Western Blot Imaging System |
| Camera | 6 MP Cooled CCD (−55 °C below ambient) |
| Resolution | 2736 × 2160 pixels |
| Pixel Size | 4.54 µm × 4.54 µm |
| Exposure Range | 10 ms – 90 min |
| Lens | f/0.95, 25 mm fixed focal length |
| Field of View | Up to 26 cm × 20 cm |
| Filter Wheel | 6-position motorized |
| Light Sources | UV (306 nm transillumination), Epi-White, Epi-Blue (470 nm), Epi-Green (530 nm), Epi-Red (630 nm), White backlight |
| Platform | 3-level manual sample stage (12×9 cm, 19×14 cm, 26×20 cm) |
| Dynamic Range | 16-bit |
| Binning Modes | Up to 6×6 |
| Auto-Focus | Yes |
| Cooling Indicator | Integrated LED status |
| Data Backup | Automatic local + network backup |
| Remote Access | LAN/WLAN via embedded Linux OS |
| Display | 10.4″ capacitive multi-touch LCD |
| Connectivity | USB 2.0 ×3, 10/100 Ethernet ×1 |
| Storage | 8 GB internal |
| Certifications | CE, FCC |
| Dimensions (L×W×H) | 452 × 423 × 659 mm |
| Weight | 52 kg |
| Power | AC 100–240 V, 50/60 Hz, 200 W |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Product Type | Imported Laboratory Dewar Flask |
| Model Series | C Series / G-C Series |
| Inner Vessel Material | Borosilicate Glass 3.3 |
| Inner Surface Finish | Full Silvering |
| Optional Features | Observation Window (customizable), Evaporation-Resistant Insulating Lid |
| Temperature Compatibility | Liquid Nitrogen (−196 °C) |
| Typical LN₂ Hold Time | 40–193 h |
| Typical LN₂ Evaporation Rate | 0.25–0.7 L/day |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DHX |
| Pricing | Upon Request |
| Tidal Volume Range | 1–50 mL / 1–150 mL / 1–300 mL / 1–500 mL (selectable) |
| Respiratory Rate | 1–199 breaths/min |
| I | E Ratio Options: 1:1, 1:2, 1:3, 2:1 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 400 × 140 × 280 mm |
| Brand | Chengmeng |
|---|---|
| Origin | Taicang, Jiangsu, China |
| Model | DHZ-LA |
| Instrument Type | Refrigerated Orbital Shaking Incubator |
| Drive System | Brushless DC Motor |
| Speed Range | 10–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | 26 mm |
| Temperature Range | 4°C to 60°C (at 25°C ambient) |
| Temperature Stability | ±0.1°C |
| Temperature Uniformity | ±0.5°C |
| Chamber Volume Capacity | 250 mL × 60, or 500 mL × 40, or 1000 mL × 24, or 2000 mL × 15, or 3000 mL × 8, or 5000 mL × 8 (with fixed-position stainless-steel clamps) |
| External Dimensions | 1200 × 780 × 960 mm (L×W×H) |
| Power Consumption | 1200 W |
| Input Voltage | 220 V, 50 Hz |
| Interior Material | Full 304 Stainless Steel |
| Exterior Finish | Electrostatically Powder-Coated Cold-Rolled Steel |
| Timer Range | 0–9999 min |
| Lighting | 8 W LED Illumination Lamp |
| UV Sterilization Lamp | 8 W |
| Safety Features | Door-Interlocked Operation, Power-Fail Memory & Auto-Restart, Over-Temperature Alarm, Sensor Fault Detection, Motor Fault Diagnostics (stall, Hall error, bus voltage anomaly, communication failure) |
| Control System | Microprocessor-Based PID Temperature Control + Dual-Loop (Speed + Current) Motor Control |
| Optional | USB Data Export Port, Adjustable Height Levelling Feet with Casters, Universal Spring Shelf (user-selectable) |
| Brand | Chengmeng |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | EVOM4 |
| Impedance Range | 0–105,000 Ω (auto-ranging across Low/Mid/High ranges) |
| Sampling Rate | 12.5 Hz |
| Sampling Averaging | 20 samples/sec |
| Current Output | 2 µA / 4 µA / 10 µA (auto/manual mode) |
| Impedance Resolution | 0.1 Ω (<200 Ω), 1 Ω (≥200 Ω) |
| Impedance Accuracy | ±0.1 Ω (<200 Ω) |
| Voltage Resolution & Accuracy | 0.1 mV |
| Display Update Interval | 0.5 s |
| Power | Rechargeable 3.7 V Li-ion battery (2500 mAh) |
| Charging Time | 5.5 h (off), 6 h (on) |
| Charging Current | 200 mA |
| Brand | Chengmeng |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | HYL-B |
| Quotation | ¥54,000 |
| Instrument Type | Reciprocating Shaker Incubator |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm (adjustable, auto-maintained) |
| Stroke Amplitude | 50–80 mm (selectable) |
| Temperature Control Range | 5–60 °C (ambient at 20 °C) |
| Shelf Quantity | 1 |
| Capacity | 70 × 250 mL or 50 × 500 mL or 18 × 1000 mL flasks |
| Display | Microprocessor-based LED digital control |
| Compressor | Imported Tecumseh (USA) |
| Drive Motor | Brushless DC motor |
| Power Consumption | 1200 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Dimensions (W×D×H) | 1300 × 800 × 1530 mm |
| Brand | Chengmeng |
|---|---|
| Origin | Jiangsu, China |
| Model | HYL-C Triple-Layer Multifunctional Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm |
| Amplitude Options | 26 mm, 35 mm, or 50 mm (user-selectable) |
| Temperature Control Range | 0–60 °C |
| Number of Shaking Platforms | 3 |
| Power Supply | 220 V, 50 Hz |
| Total Power Consumption | 3000 W |
| Dimensions (W×D×H) | 1300 × 750 × 1800 mm |
| Capacity per Platform | 18 × 1000 mL flasks |
| Interior Material | Polished Stainless Steel with LED Illumination |
| Exterior Finish | Cold-Rolled Steel with Electrostatic Powder Coating |
| Door Configuration | Dual Front Doors |
| Brand | Chengmeng |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LA-30000 |
| Price | USD 56,000 (FOB) |
| Stimulation Principle | LED-driven optical excitation |
| Instrument Architecture | Multi-channel parallel stimulation |
| Wavelength | 625 nm (centered) |
| Spectral Bandwidth | ±10 nm (FWHM) |
| Irradiance Range | 0–100 mW/cm² (adjustable per well) |
| Temporal Resolution | 1 ms pulse width, 0.1–10 Hz frequency range |
| Pulse Duration | 1 ms to 60 min (programmable) |
| Operating Environment | 20–40 °C, up to 95% RH (IP55-rated electronics) |
| Dimensions (W×D×H) | 240 × 180 × 95 mm |
| Cooling | Active thermal regulation with linear PWM-controlled fan |
| Uniformity | ±5% irradiance deviation across all wells (factory-calibrated) |
| Compliance | CE, RoHS, ISO 13485-aligned design documentation |
| Brand | Chengmeng |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MEP Microelectrode-Based Electroporation System |
| High-Voltage Range | 0–1200 V (adjustable) |
| Low-Voltage Range | 0–50 V (for pre-pulse stabilization) |
| Capacitance Range | 1–100 µF (selectable) |
| Pulse Duration | 1–100 ms (adjustable) |
| Number of Pulses | 1–99 per cycle |
| Pulse Interval | 100 ms–5 s (programmable) |
| Output Waveform | Exponential decay and square-wave modes |
| Internal Resistance | <50 Ω (system-optimized for microelectrode coupling) |
| Electrode Compatibility | Standard 1.0 mm OD borosilicate capillaries (Sutter BF150-86-10, World Precision Instruments TW-100F, etc.) |
| Embryo Survival Rate (Mouse 2-cell stage) | 80–85% post-electroporation |
| Brand | Chengmeng |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SYS-260 Dual-Channel Nanoscale Electrophoretic Current Generator |
| Current Range | 0.1–1000 nA (selectable ranges: 100 nA / 1000 nA full-scale) |
| Output Channels | 2 independent, battery-powered electrophoretic current sources |
| Polarity Control | Manual toggle (±) |
| Operation Mode | Front-panel selectable manual or timed auto-injection |
| Compliance | Designed for intracellular and extracellular microinjection in electrophysiology and neuropharmacology workflows |
| Brand | Chengmeng |
|---|---|
| Origin | Jiangsu, China |
| Model | THZ-C-L Benchtop Refrigerated Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–300 rpm |
| Amplitude | 26 mm |
| Temperature Range | 5–60 °C (at 25 °C ambient) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.5 °C |
| Platform Capacity | 6 × 1000 mL or 20 × 250 mL flasks |
| Power Consumption | 600 W |
| Dimensions (W×D×H) | 800 × 590 × 500 mm |
| Net Weight | 56 kg |
| Power Supply | 220 V, 50 Hz |
| Platform Quantity | 1 |
| Brand | Chengmeng |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | UMP3 |
| Instrument Type | Motorized, Programmable |
| Reservoir Capacity | 580 µL |
| Syringe Volume Range | 0.5 µL to 1000 µL |
| Syringe Barrel Diameter | 5.5 mm to 9 mm (ISO Standard) |
| Minimum Dispensed Volume | 580 pL (with 10 µL syringe) |
| Flow Rate Range | 0.5 pL/s to 1000 µL/min (dependent on syringe geometry and motor resolution) |
| Step Resolution | Sub-nanoliter per step |
| Operating Temperature Range | 4–40 °C |
| Vibration Damping | Circular pump housing with optimized stepper motor mounting |
| Control Interface | Dual-channel capacitive touchscreen controller with endpoint limit protection, silent mode, and audit-ready parameter logging |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CQY-1 |
| Pricing | Available Upon Request |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM-6240BD / RM-6240CD |
| Interface | USB 2.0 |
| Max Sampling Rate | 1000 kHz (single channel) |
| Input Impedance | ≥100 MΩ (differential) |
| CMRR | ≥100 dB |
| Input Noise | ≤±1 µV RMS |
| Frequency Response | DC–10 kHz |
| Input Range | 5 µV–500 mV |
| Sensitivity Ranges | Bioelectric: 20 µV/div–500 mV/div |
| Blood Pressure | 0.48–24 kPa/div or 3.6–180 mmHg/div |
| Hardware Filters | Low-pass: 3/10/30/100/500/1k/3k Hz, OFF |
| Time Constant | 0.001–5 s, DC |
| Stimulator Output | Voltage: 0–150 V (opt.), Current: 0–150 mA |
| Pulse Width/Delay/Interval | 0.1–1000 ms |
| Frequency | 1–3000 Hz |
| Calibrated Transducers | Tension: 0–50 g, Sensitivity: 100 mV/30 g (6 V DC) |
| Pressure | −10 to +40 kPa, Sensitivity: 25 mV/12 kPa (6 V DC) |
| Brand | Chengyi (scchengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM6240E/EC |
| Channel Count | 4 (expandable to 8 or 16 via daisy-chaining) |
| A/D Resolution | 16-bit |
| Max Single-Channel Sampling Rate | 1,000 kHz |
| Min Sampling Rate | 0.01 Hz |
| Continuous 4-Channel Sampling Rate | 200 kHz |
| Input Impedance | ≥100 MΩ (differential), ≥50 MΩ (single-ended) |
| CMRR | ≥100 dB |
| Input Noise | ≤±1 µV RMS / ≤±3 µV P-P |
| Frequency Response | DC–20 kHz |
| Input Range | 5 µV–500 mV |
| Gain Settings | 10 µV/div–500 mV/div (bioelectric), 0.36–360 mmHg/div (blood pressure) |
| Hardware Filters | Low-pass (0.3 Hz–20 kHz, OFF), Time Constant (0.001 s–DC), 5+ order analog filtering |
| Stimulator Output | ±50 V max, ≤100 mA, programmable pulse modes (single, train, dual, incremental, timed), galvanically isolated |
| ECG Lead Support | Full 12-lead (I, II, III, aVR, aVL, aVF, V1–V6), software-switchable |
| Environmental Sensors | Integrated temperature, atmospheric pressure, and humidity measurement |
| Software Certifications | Certified software copyright (No. 2012SR137470), Sichuan Software Registration Certificate (Chuan DGY-2013-0154) |
| Data Export | MATLAB (.mat), SPSS (.sav), SAS (.sas7bdat), CSV |
| Compliance | Meets national safety standards for biomedical instrumentation (leakage current <3 mA) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ChloroPen NC |
| Price | Upon Request |
| Measurement Principle | Dual-Wavelength Reflectance (700–840 nm) |
| Minimum Measurement Distance | 28.4 cm |
| Maximum Measurement Distance | 183 cm |
| Spot Diameter | 1.35 cm (at 30.5 cm), 3.0 cm (at 46 cm), 11.8 cm (at 122 cm) |
| Measurement Interval | >2 s per reading |
| Repeatability | ±5% of reading |
| Sample Types | Intact leaves, turfgrass canopies |
| Brand | Chongqing Optics |
|---|---|
| Origin | Chongqing, China |
| Model | XDS-1B |
| Total Magnification | 100×–640× |
| Illumination | Built-in 6 V / 20 W halogen lamp with adjustable brightness and filter wheel |
| Focus Mechanism | Coaxial coarse/fine focus with 20 mm travel, fine focus graduation 0.02 mm, upper-limit stop & locking mechanism |
| Eyepiece Tube | Dual-port 45° inclined binocular tube, interpupillary adjustment 55–75 mm, diopter correction |
| Objective Turret | 4-position, centering precision turret with ball-bearing rotation and anti-fungal coating |
| Stage | Rectangular mechanical stage (155 × 180 mm), X–Y travel 50 × 75 mm |
| Condenser | Long-working-distance condenser, W.D. = 55.2 mm, NA = 0.3 |
| Objectives | LPL Plan Achromatic Long Working Distance Objectives — LPL10×/0.25 (W.D. 7.9 mm), LPL25×/0.40 (W.D. 5 mm), LPL40×/0.65 (W.D. 3 mm) |
| Phase Contrast | Optional Ph25× objective (W.D. 5 mm) with 25× phase ring slider |
| Eyepieces | Wide-field WF10×/20, WF16×/14, WF10× reticle/18, 11× centering eyepiece |
| Compliance | ISO 9001:2015, ISO 14001:2015, CE (Low Voltage Directive 2014/35/EU), Medical Device Registration No.: Yu Food & Drug Admin Med Cert (Approval) No. 2007-2220053 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | CZ1 / CZ2 |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis System |
| Primary Component | Vertical Electrophoresis Tank |
| Gel Format | Single-gel configuration |
| Sample Capacity | 1 gel per run |
| Voltage/Current Rating | 1 (unit unspecified |
| Brand | Chu Ding |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HCC-02 |
| Instrument Type | Semi-Automatic Colony Counter |
| Counting Speed | 150 colonies/min |
| Optical Magnification | 3× and 6× |
| Brand | Chu Ding |
|---|---|
| Model | HD-2000 |
| Detection Principle | Dual-wavelength UV absorbance (220, 254, 280, 340 nm) |
| Optical Path Length | 3 mm |
| Sample Cell Volume | 100 µL |
| Transmittance Range | 0–100% T |
| Absorbance Range | 0–0.2 A |
| Display | LED digital (T/A dual-mode) |
| Output Signals | 10 mV recorder output |
| UV Lamp Power | 6 W |
| UV Filter Dimensions | 200 × 80 mm |
| Input Voltage | 220 V AC |
| Dimensions (W×D×H) | 285 × 165 × 190 mm |
| Instrument Type | Benchtop |
| Origin | Shanghai, China |
| Compliance | Designed for GLP-compliant chromatographic workflows per ISO 17025 and USP <857> UV-Vis detection guidelines |