| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nexera GPC System |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System for Gel Permeation Chromatography |
| Price Range | USD 70,000 – 140,000 (approx. based on ¥500,000–¥1,000,000 at current exchange rate) |
| Flow Rate Range | Not applicable (GPC-specific isocratic or low-gradient elution |
| Maximum Pressure Rating | Not specified in source (typical for GPC: ≤40 MPa) |
| Sample Injection Positions | Configurable via SIL-40 series autosampler (up to 216 vials standard) |
| Injection Volume Range | 0.1–100 µL (autosampler-dependent) |
| Column Oven Temperature Range | 4–85 °C (standard CTO-40 series column oven) |
| UV/VIS Wavelength Range | 190–800 nm (with SPD-M40 photodiode array detector or SPD-40V UV-Vis detector) |
| Data Acquisition Rate | Up to 100 Hz (detector-dependent) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum System Pressure | 130 MPa |
| Autosampler Capacity | Up to 16,800 positions (via microplate stacking) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | –10°C to 85°C |
| UV-Vis Detector Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Detector Options | SPD-40/SPD-40V UV-Vis, SPD-M40 Diode Array Detector (DAD) |
| Compliance | ASTM D7097, ISO 17025, USP <621>, FDA 21 CFR Part 11 (with LabSolutions™ CS audit trail enabled) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Series | LC-40 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.0001–10 mL/min |
| Maximum System Pressure | 130 MPa |
| Autosampler Capacity | 162 positions (1.5 mL vials) |
| Injection Volume Range | 0.1–50 µL |
| Column Oven Temperature Range | (Ambient −10 °C) to 100 °C |
| UV-Vis Detection Wavelength Range | 190–1000 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Model | Nexera LC-40 |
| Application Scope | General-purpose analytical laboratory use |
| Flow Rate Range | Up to 5.0 mL/min |
| Maximum Operating Pressure | 130 MPa (1300 bar) |
| Flow Accuracy | ≤0.1% RSD |
| Injection Volume Range | 0.1–100 µL |
| Sample Tray Capacity | Up to 216 positions (with optional 2nd tray) |
| Column Oven Temperature Range | 4–85 °C |
| UV-Vis Detection Wavelength Range | 190–800 nm |
| Data Acquisition Rate | Up to 125 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Nexera XS inert |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Bioanalytical LC |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Operating Pressure | 105 MPa |
| Flow Precision | ≤0.06% RSD or ≤0.02 min SD (whichever is greater) |
| Injection Volume Range | 0.1–50 µL |
| Autosampler Capacity | 252 positions (1 mL vials) / 162 positions (1.5–2 mL vials) / 84 positions (4 mL vials) |
| Column Oven Temperature Range | Ambient −10 °C to 100 °C (85 °C for high-stability operation) |
| UV-Vis Wavelength Range | SPD-40 detector: 190–700 nm |
| SPD-40V detector | 190–1000 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Nexera-e |
| Instrument Type | Comprehensive 2D-LC System |
| Flow Rate Range | Not Applicable (Modular Dual-Flow Architecture) |
| Maximum System Pressure | 130 MPa (2nd Dimension) |
| Sample Injection Positions | Dual Sample Loops with Alternating Switching |
| Injection Volume Range | Configurable via Loop Selection (e.g., 1–100 µL) |
| Column Oven Temperature Range | Ambient to 85 °C |
| Wavelength Range (DAD) | 190–800 nm |
| Data Acquisition Rate | Up to 125 Hz (SPD-M30A), 20,000 u/sec (LCMS-IT-TOF) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Prominence Plus LC-20A |
| Instrument Category | Fast Liquid Chromatography System |
| Application Scope | General-purpose HPLC analysis |
| Maximum Operating Pressure | 44 MPa (LC-20AT) / 66 MPa (LC-20ADXR) |
| Flow Rate Precision | ≤0.06% RSD or ≤0.02 min SD |
| Injection Volume Range | 0.1–50 µL (standard), 0.1–2000 µL (optional) |
| Sample Tray Capacity | 175 positions (1 mL vials) |
| Column Oven Temperature Range | Ambient +10 °C to 85 °C (standard) |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Prominence Plus LC-30A |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Flow Rate Precision | <0.06% RSD or 0.02 min SD (whichever is greater) |
| Injection Volume Range | 0.1–50 µL |
| Sample Capacity | 175 positions (1 mL vials) |
| Column Oven Temperature Range | Ambient ±10 °C to 85 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Prominence UFLC |
| Instrument Type | Ultra-Fast Liquid Chromatograph |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RF-10A |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RF-10A |
| Price | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | SIL-30ACMP |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPD-10Avp |
| Instrument Type | Conventional HPLC Detector |
| Wavelength Range | 190–600 nm |
| Noise | ±0.35 × 10⁻⁵ AU |
| Drift | ≤ ±2 × 10⁻⁴ AU/h |
| Flow Cell Volume | 8 µL (standard) |
| Dimensions | 260 × 140 × 420 mm (W × H × D) |
| Weight | 13 kg |
| Operating Temperature | 4–35 °C |
| Lamp | Long-life Deuterium Lamp (D₂), programmable ON/OFF control |
| Optical Design | Separated lamp chamber and monochromator with active lamp cooling |
| Baseline Stability | Engineered for high reproducibility in regulated QC environments |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 700 bar (standard), 1000 bar (optional high-pressure configuration) |
| Autosampler Capacity | 768-well microplate or 108-position 2 mL vial tray |
| Column Oven Temperature Range | 5–85 °C |
| UV-Vis Detection Wavelength Range | 190–1000 nm |
| Data Acquisition Rate | 50–100 Hz |
| Gradient Formation Options | Isocratic, Binary High-Pressure, Quaternary Low-Pressure |
| Pump Head Options | Interchangeable 5 mL, 10 mL, and 50 mL heads |
| Detector Options | UV/VIS, Diode Array Detector (DAD), Refractive Index Detector (RID) with Intelligent Temperature Control |
| System Architecture | Modular, Front-Access Design for Maintenance |
| Brand | Shine |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 42 MPa |
| Flow Accuracy | ≤0.06% RSD (ASTM D7507) |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 10–500 µL |
| Column Oven Temperature Range | Ambient +5°C to 65°C |
| UV-Vis Detection Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC-310 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0–10 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Sample Vial Capacity | 108 positions (2 mL vials) |
| Injection Volume Range | 0–20 µL |
| Column Oven Temperature Range | Ambient +5°C to 80°C |
| UV-Vis Wavelength Range | 190–680 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | SofTA |
|---|---|
| Origin | USA |
| Model | UM3000 |
| Detection Principle | Evaporative Light Scattering |
| Light Source | 650 nm Laser Diode |
| Detector | Photomultiplier Tube (PMT) |
| Evaporation Zone Temp Range | Ambient to 130 °C |
| Nebulizer Tube Temp Range | Ambient to 80 °C |
| Temp Control Increment | 1 °C |
| Temp Accuracy | ±1 °C |
| Mobile Phase Flow Rate | 10 µL/min to 3 mL/min |
| Carrier Gas | Nitrogen or Compressed Air |
| Gas Input Pressure | 2–5 bar |
| Gas Pressure Measurement Accuracy | 0.01 bar |
| Gas Consumption | 1–4 L/min |
| Detection Limit | <1 ng (glucose, direct injection) |
| Typical Quantitation Range | 0.2–10 µg (glucose, HPLC) |
| Noise Level | <0.1 mV (at 1 mL/min) |
| Signal Output | 0–10 mV DC or 0–1 V DC |
| Interface | RS232 |
| Detection Angle | 120° |
| Display | LCD |
| Operating Environment | 15–35 °C, RH <90% |
| Power Supply | 220 VAC, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Lanbo |
| Pricing | Available Upon Request |
| Brand | SOPOTOP |
|---|---|
| Origin | Shanghai, China |
| Model | LC1620A |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 45 MPa |
| Autosampler Capacity | Up to 120 positions |
| Injection Volume Range | 0.1–120 μL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV Detector Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Flow Accuracy | ≤±0.5% (at 1 mL/min, water) |
| Flow Precision (RSD) | ≤0.08% (at 1 mL/min, water) |
| UV Wavelength Accuracy | ±1 nm |
| UV Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤±0.8×10⁻⁵ AU |
| Baseline Drift | ≤1×10⁻⁴ AU/h |
| LOD (UV) | 0.4×10⁻⁸ g/mL (naphthalene in methanol) |
| Linear Dynamic Range (UV) | ≥10⁴ |
| RI Detector Refractive Index Range | 1.00–1.75 |
| ELSD Evaporator Temp Range | Ambient to 130°C |
| ELSD Detection Limit | <1 ng (glucose, direct injection) |
| Autosampler Precision (RSD) | <0.5% |
| Carryover | <0.01% |
| Brand | Spark Holland |
|---|---|
| Origin | Netherlands |
| Model | UHPLC Spark |
| Instrument Type | Ultra-High-Performance Liquid Chromatography–Online Solid-Phase Extraction (UHPLC–SPE) System |
| Flow Rate Range | 1–4000 µL/min |
| Maximum Pressure | 18,850 psi |
| Flow Precision | ≤ 0.075 % RSD (at 200–2000 µL/min) |
| Flow Accuracy | ±1 % (at 200–2000 µL/min) |
| Sample Tray Capacity | 96 positions × 1.5 mL vials |
| Injection Volume Range | 1–10,000 µL |
| Column Oven Temperature Range | 5–90 °C |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | SSI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Model 6000 Diode Array Detector |
| Pricing | Available Upon Request |
| Wavelength Range | 190–800 nm |
| Optical Path Length / Flow Cell Volume | 5 cm / 12 µL |
| Noise | ±3 × 10⁻⁶ AU/cm |
| Drift | 1 × 10⁻³ AU/hr |
| Linearity | >2.0 AU |
| Scan Rate | ≤20 Hz |
| Spectral Resolution | 1.2 nm |
| Wavelength Accuracy | ±1 nm |
| Light Source | Deuterium Lamp + Tungsten-Halogen Lamp |
| A/D Converter | 20-bit |
| Photodiode Array | 512 elements |
| Beam Conditioning | Stacked Optical Fiber Assembly |
| Calibration Reference | Holmium Oxide (Ho₂O₃) Solution Cell |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-2000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Maximum Pressure | 6000 psi |
| Flow Rate Range | 0.01–19.98 mL/min |
| Gradient Accuracy | ±0.1% |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Baseline Drift | 2 × 10⁻⁴ AU/hr |
| Detector | SSI Model 500 UV-Vis Variable Wavelength Detector |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | LC1620A |
| Instrument Category | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 45 MPa |
| Autosampler Capacity | 0–120 positions |
| Injection Volume Range | 0–120 µL |
| Column Oven Temperature Range | Ambient +5°C to 100°C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 1 Hz |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC1620APlus |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.000–10.000 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | ≤ ±0.3% RSD |
| Wavelength Range (UV-Vis Detector) | 190–680 nm |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-501 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–999.9 µL |
| Column Oven Temperature Range | 4–100 °C |
| UV/Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-504 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 60 positions × 1.5 mL vials or 96 positions × 0.5 mL vials |
| Injection Volume Range | 0.1–999.9 µL |
| Column Oven Temperature Range | 4–100 °C |
| UV/Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 10 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestically Assembled (China) |
| Model | Orbitrap Exploris™ 120 |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EASY-nLC 1000 |
| Instrument Type | Nanoflow Liquid Chromatography System |
| Column ID | 50 µm |
| Packing Particle Size | 1.9 µm |
| Maximum Operating Pressure | Up to 1000 bar |
| Gradient Precision | <0.2% RSD |
| Flow Rate Range | 50–1000 nL/min |
| Injection Volume Precision | <1% RSD |
| System Dead Volume | <100 nL |
| Software Platform | Thermo Scientific Xcalibur |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EASY-nLC 1200 |
| Instrument Type | Nanoflow Liquid Chromatography System |
| Maximum Operating Pressure | 1200 bar |
| Column Compatibility | 75 cm columns packed with 1.9 µm particles |