Mass Spectrometry Instruments
Filter
Showing 541–570 of 765 results
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | ICP-MS 2000 Series |
| Mass Analyzer Type | Quadrupole Mass Spectrometer |
| Intended Use | Laboratory-Based Elemental Analysis |
| Regulatory Compliance | Meets or exceeds GB/T 35791–2018 (Chinese National Standard for ICP-MS Performance Verification) |
| Software Platform | Windows 2000/XP/Vista/7 (32-bit & 64-bit) Compatible Control System |
| Sample Introduction | Integrated Peltier-Cooled Glass Cyclonic Spray Chamber (–20 °C to +20 °C), One-Piece Quartz Concentric Torch, Open-Access Nebulizer Assembly |
| Vacuum Interface | Dual-Conical Interface with Removable Sampling Cone (1.1 mm orifice) and High-Salt/High-Sensitivity Skimmer Cone Options (0.75 mm standard) |
| Ion Optics | Asymmetrically Mounted Extraction & Deflection Lenses, ETP Dual-Mode Detector (Analog/Digital Switching), Computer-Controlled Auto-Tuning |
| Automation | 250-Position Autosampler (Ethernet-Controlled, Positioning Accuracy < 500 µm) |
| RF Generator | Solid-State Frequency-Tunable Generator with Cold Plasma Mode, Collision/Reaction Cell Mode, and Standard Mode Support |
| Collision/Reaction Cell | Hexapole-Based, H₂/He Mixed-Gas KED Mode Enabled |
| Detection Modes | Full-Scan, Peak-Hopping, Time-Resolved Analysis (TRA) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Domestic (China-made) |
| Model | GC-MS 6800 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Mass Range | 1.5–1000 amu |
| Resolution | Unit Mass Resolution |
| Sensitivity | ≥30:1 S/N (RMS) for 1 pg Octafluoronaphthalene (OFN) at m/z 272 |
| Scan Speed | Up to 10,000 amu/s |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Conventional Gas Chromatograph with Electronic Flow and Pressure Control (EFC/EPC) |
| Ion Source | Dual-Filament Electron Ionization (EI) Source |
| Mass Analyzer | 180 mm Rod-Length Quadrupole with Pre-Filter RF Compensation |
| Mass Range | 1.5–1000 amu |
| Resolution | Unit Mass Resolution (UMR) |
| Sensitivity | ≥30:1 S/N for 1 pg Octafluoronaphthalene (OFN) in Full Scan Mode |
| Scan Speed | 10,000 amu/s |
| Library | NIST2014 Mass Spectral Library (Standard) |
| Compliance | Designed to Support GLP/GMP Data Integrity Requirements (Audit Trail, User Authentication, Electronic Signatures Optional via Software Configuration) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | POW-I |
| Pricing | Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TDM3000-MS |
| Mass Range | m/z 10–2000 amu |
| Sensitivity | >0.4 pg (positive ion mode), >0.8 pg (negative ion mode) |
| Analyzer Type | Single Quadrupole |
| Application Domain | Therapeutic Drug Monitoring (TDM)–Specific Clinical Use |
| Sample Throughput | Up to 150 samples per day |
| Online Sample Cleanup | Integrated protein/ phospholipid/salt removal via dual-column extraction and valve-switching architecture |
| Extraction Column Lifetime | ≥2000 injections |
| Ionization Source | Electrospray Ionization (ESI) |
| Detection Mode | Quantitative and Qualitative Analysis of Small Organic Molecules in Human Serum |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | UPY-6800 |
| Quotation | Upon Request |
| Mass Analyzer Type | Single Quadrupole |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Sample Introduction | Integrated Pyrolyzer Module (Thermal Desorption/Pyrolysis Interface) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole LC-MS |
| Mass Range | m/z 10–2000 amu |
| Sensitivity | ≥50:1 S/N (RMS) for 10 pg reserpine in ESI+ mode |
| Resolution | Unit mass resolution (peak width at 10% height: ≤0.7 amu) |
| Mass Accuracy | ≤±0.20 amu |
| Ionization Sources | ESI (standard), APCI & APPI (optional) |
| Polarity Switching Time | ≤20 ms (−10 kV to +10 kV) |
| Vacuum System | High-speed imported turbomolecular pump |
| Software | ChemAnalyst v3.x with 21 CFR Part 11 compliance modules, audit trail, user privilege management, and GLP/GMP-ready workflow support |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | microTyper MS |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Mass Resolution | R ≥ 500 |
| Sensitivity | Signal-to-Noise Ratio ≥ 100 |
| Mass Stability | ≤ 800 ppm |
| Mass Accuracy | ≤ 500 ppm |
| Mass Range | > 16,000 u |
| Repeatability | ≤ 0.06% |
| Ion Source | Matrix-Assisted Laser Desorption/Ionization (MALDI) |
| Detector | Large-Area Microchannel Plate (MCP) |
| Laser | Long-Life Nitrogen UV Laser (1–60 Hz Tunable) |
| Acquisition Rate | Up to 3 GHz sampling rate |
| Vacuum System | 320 L/s Turbo Molecular Pump |
| Sample Target | 96-well Reusable Stainless Steel Plate with 6 QC Spots |
| Exhaust Treatment | Triple-Stage Sterilization Unit |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | SHP8400PMS-I |
| Mass Range | 1–200 amu (300 amu optional) |
| Ion Source | Electron Impact (EI) |
| Mass Analyzer | Quadrupole |
| Detector | Dual-mode — Faraday Cup and Electron Multiplier |
| Vacuum System | Rotary Vane Pump + Turbo Molecular Pump |
| Mass Axis Stability | < ±0.1 amu/24 h |
| Detection Limits | 10 ppm (Faraday), 10 ppb (Electron Multiplier) |
| Minimum Detectable Partial Pressure | 5×10⁻¹¹ Torr (Faraday), 5×10⁻¹⁴ Torr (Electron Multiplier) |
| Number of Simultaneous Components | Unlimited |
| Scan Speed | 200 ms per spectrum |
| Inlet System | Motorized Multi-Port Rotary Valve (solenoid valve option available) |
| Digital Output | DDE, OPC DA/UA compliant |
| Analog Output | 4–20 mA or 0–10 V |
| Environmental Rating | General Purpose / Hazardous Area (ATEX/IECEx optional) |
| Brand | SOPTOP |
|---|---|
| Origin | Shanghai, China |
| Model | SHP8400PMS-I |
| Price Range | USD 140,000 – 280,000 |
| Certifications | Ex d IIB T4 Gb / IP66 |
| Detection Principle | Quadrupole Mass Spectrometry (QMS) |
| Mass Range | 1–100 amu (standard), up to 300 amu (optional) |
| Resolution | Unit mass resolution (M/ΔM ≥ 100 at 10% valley) |
| Detection Limit | <1 ppm (for N₂, O₂, CH₄, CO, CO₂, H₂, Ar, etc.) |
| Sampling Channels | Up to 16 independent gas inlets with sequential auto-switching |
| Vacuum System | Dual-stage: Turbo-molecular pump (≥ 300 L/s) + Dry scroll backing pump |
| Operating Temperature | −10 °C to +50 °C ambient |
| Response Time | <3 s per component (typical), <30 s for full 16-channel cycle |
| Data Output | Modbus TCP, OPC UA, 4–20 mA analog outputs (configurable) |
| Compliance | IEC 60079-0/-1/-11, GB 3836.1/2/4, ISO/IEC 17025 (when operated per validated SOP) |
| Brand | Kunyuan Instruments |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | Sparkle |
| Price Range | USD 810,000 – 910,000 (based on exchange rate of ¥1 = USD 0.14) |
| Brand | EXPEC (Hangzhou Puyu Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Quadrupole ICP-MS |
| Configuration | Integrated Glovebox-Coupled System |
| Application Environment | Laboratory-Based Elemental Analysis |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO/IEC 17025 method validation frameworks |
| Sample Handling | Fully enclosed, operator-isolated glovebox integration (vacuum/negative-pressure/ultra-clean operation) |
| Matrix Tolerance | Direct analysis of up to 10% total dissolved solids (TDS) |
| Detection Limit | Sub-ppt (ng/L) for key isotopes under optimized conditions |
| Ion Source | Self-excited all-solid-state RF generator with argon plasma stabilization |
| Interface Design | Aerodynamically optimized ion optics at plasma–vacuum boundary |
| Collision/Reaction Cell | Integrated dynamic reaction cell (DRC) with multi-gas capability (He, H₂, NH₃, O₂) |
| Automation Readiness | Compatible with EXPEC automated inorganic sample preparation platforms |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPECTROGREEN MS |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range | 4–255 amu |
| Unit Mass Resolution | 0.2–0.66 amu |
| Detection Limit | Sub-ppt (ng·L⁻¹) |
| Sensitivity | Co ≥ 360 Mcps/(mg·L⁻¹), Y ≥ 400 Mcps/(mg·L⁻¹) |
| Short-Term Stability (RSD) | <1% |
| Long-Term Stability (RSD) | <2% |
| Brand | SpectrUM / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EXPEC 7200 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 1–280 |
| Resolution (Unit Mass Resolution, amu) | ≤0.75 |
| Detection Limit (ng·L⁻¹) | <0.05 for ⁹Be, <0.003 for ²³⁸U |
| Sensitivity (Mcps/mg·L⁻¹) | >350 for ²³⁸U |
| Short-Term Stability (RSD, 10 min) | <2% |
| Long-Term Stability (RSD, 2 h) | <3% |
| Brand | HEXIN Mass Spectrometry |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPI-MS 3000 |
| Pricing | Upon Request |
| Brand | SRS/Stanford Research Systems |
|---|---|
| Origin | USA |
| Model | RGA1-100amu, RGA1-200amu, RGA1-300amu |
| Mass Range | 1–100 amu / 1–200 amu / 1–300 amu |
| Resolution | <0.5 amu (FWHM) |
| Detection Limit | 5 × 10⁻¹⁴ Torr (with EM detector) |
| Sensitivity | 2 × 10⁻⁴ A/Torr (Faraday cup) |
| Dynamic Range | 6 decades |
| Response Time | 1–2 s |
| Detector Options | Faraday Cup (standard), Electron Multiplier (optional) |
| Operating Pressure Range | 10⁻⁴ Torr to UHV (FC) |
| Max. Probe Temperature | 70 °C |
| Max. Bakeout Temperature | 300 °C (probe only, ECU excluded) |
| Interface | RS-232 |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC1290/MS8100 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | 1.5–1100 u |
| Resolution | >1200 (FWHM) |
| Sensitivity | 600:1 (S/N for 1 pg octafluoronaphthalene) |
| Scan Speed | Up to 24,000 u/sec |
| Oven Ramp Rate | 0–80 °C/min |
| Pressure Control Accuracy | 0–100 psi |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1–1000 amu |
| Mass Resolution (FWHM) | ≥1200 (at m/z 502) |
| Sensitivity | ≥200:1 (Signal-to-Noise Ratio, S/N, for 1 pg OFN in Full Scan Mode) |
| Scan Speed | ≥10,000 u/s |
| Oven Ramp Rate | ≥80 °C/min |
| Pressure Control Accuracy | ±0.01 psi (EPC-controlled) |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | SHP8400PMS |
| Operating Principle | Electron Ionization (EI) coupled with Quadrupole Mass Analysis |
| Response Time | 16 ms per amu |
| Mass Range | 1–100 amu (standard configuration) |
| Mass Stability | < ±0.1 amu over 72 h |
| Sampling Channels | 16 independent channels with temperature-controlled capillary lines |
| Detection System | Faraday Cup Detector |
| Ion Source | Dual-filament EI source with enhanced water/oxygen tolerance |
| Flow Control | Integrated temperature-compensated electronic mass flow controller (MFC) |
| Data Output Format | OPC UA, Modbus TCP, ASCII CSV |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible logging |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Category | Domestic (China-Made) |
| Model | SHP8400PMS-L |
| Price Range | USD 42,000 – 70,000 |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | SHP8400PMS-LD |
| Pricing | Available Upon Request |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | SHP8400PMS-Li |
| Pricing | Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 5220 |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Scope | General-Purpose LC-MS/MS Platform |
| Configuration | Integrated Online SPE-LC-MS/MS |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | SUPEC 7000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory-Based Analysis |
| Key Features | High-Temperature Gas Flow Control, Multi-Stage Gradient Vacuum System, High-Efficiency Ion Interface, Distributed Collision/Reaction Cell, Temperature- and Humidity-Stable Quadrupole Mass Analyzer |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Software Platform | EXPEC ICP-MS Control Suite v3.2 (with method validation templates, QC flagging, and raw data integrity logging) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | SUPEC 7010 |
| Instrument Type | Quadrupole ICP-MS |
| Application Domain | Laboratory & Environmental Monitoring |
| Compliance | HJ 700–2014 |
| Automation Level | Fully Automated Sample Intake, Filtration, Pre-treatment, Analysis, QC, and Data Transmission |
| Detection Scope | Multi-element (As, Cd, Cr, Cu, Hg, Ni, Pb, Zn, etc.) in Surface Water, Groundwater, Drinking Water, and Seawater |
| Measurement Time per Sample | <5 min |
| Interference Resistance | High (immune to color, turbidity, matrix-induced polyatomic interferences via collision/reaction cell technology) |
| Environmental Profile | Low reagent consumption, no electrode wear, near-zero liquid waste generation |
| Regulatory Alignment | Designed for GLP-compliant operation |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Automation Level | Full End-to-End Sample-to-Result Automation |
| Sample Forms Supported | Solid and Liquid Matrices |
| Acid Compatibility | HNO₃, HCl, HF, HClO₄ |
| Volumetric Accuracy | <0.025 mL (5–50 mL range) |
| Sample Introduction | Integrated Auto-Sampling with In-Line Filtration |
| Safety Features | Auto-Ignition, Auto-Optimization, Auto-Quenching, Acid-Fume Extraction, Corrosion-Resistant Fluidic Pathways |
| Calibration & QC | Auto-Standard Curve Generation, Multi-Point QC Triggering (LOD, Blank, CRM), Adaptive Response Logic (Re-run / Skip / Abort) |
| Data Interface | Real-Time CPS/Concentration/RSD Dashboard, Interactive Calibration Plotting, Outlier Flagging |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SUPEC 7030 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory & Continuous Ambient Air Monitoring |
| Detection Mode | Online Automated ICP-MS Analysis with Integrated Sample Preparation |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | FIB-SEM-TOF-SIMS |
| Price Range | USD 1.3M–2.6M (FOB Europe) |
| Mass Analyzer Type | Time-of-Flight (TOF) |
| Primary Ion Beam Energy | 30 kV |
| Mass Range | 1–2500 Da |
| Mass Resolution (M/ΔM) | >800 (at 10% valley definition) |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Nanospace SIMS |
| Instrument Type | Orthogonal Time-of-Flight (OTOF) SIMS |
| Mass Range | 1–1,500 Da |
| Mass Resolution | >9,500 (FWHM at m/z 100) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Chromeleon™ 7.4 |
| Pricing | Available Upon Request |