Moisture Analyzer
Filter
Showing 571–600 of 676 results
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP122 |
| Price | Upon Request |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Measurement Range | 0–1000 mS/cm |
| Accuracy | ±2.5% F.S. |
| Resolution | 0.1 mS/cm |
| Repeatability | 1% F.S. |
| Temperature Sensor | Pt1000 |
| Temp. Compensation Range | 0–60 °C |
| Sample Temp. Range | 5–50 °C |
| Ambient Temp. Range | 5–45 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Error | ±0.5 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Storage Temp. | −25–55 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Dimensions | 145 × 120 × 150 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.64 kg |
| Isolated Current Output | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Load Capacity | ≤750 Ω |
| Output Accuracy | 1% F.S. |
| Relay Output | AC 250 V / 5 A or DC 30 V / 5 A |
| Mounting | Panel-mount / Wall-mount / Rack-mount |
| Electrode Options | Flow-through / Immersion / Flanged (custom configurations available) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP130 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Equipment Co., Ltd. |
| Model | TP140 |
| Measurement Principle | Conductivity-based concentration determination |
| Measurable Media | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% FS |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Temperature Sensor | Pt1000 |
| Temp. Measurement Range | 0.0–99.9 °C |
| Temp. Compensation Range | 0.1–60.0 °C |
| Sample Temp. Range | 5–60 °C |
| Ambient Temp. Range | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | <5 W |
| Enclosure Rating | IP65 |
| Dimensions (L×W×H) | 142 mm × 125 mm × 155 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 1.6 kg |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Relay Outputs | 2 SPST, AC220 V / 3 A or DC30 V / 3 A |
| Data Storage | Cyclic non-volatile memory, >10 years retention after power loss |
| Mounting Options | Panel-mount (standard), wall-mount, rack-mount |
| Electrode Mounting | Flow-through, immersion, flanged, or inline pipe mount |
| Display | 128×64 dot-matrix LCD, full Chinese interface |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP140 |
| Pricing | Upon Request |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Measurement Ranges | HCl (0–10.00%), NaOH (0–10.00%), H₂SO₄ (0–20.00%), NaCl (0–20.00%), HNO₃ (0–15.00%), Na₂CO₃ (0–10.00%) |
| Accuracy | ±2% F.S. |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Temperature Sensor | Pt1000 |
| Temp. Measurement Range | 0.0–99.9 °C |
| Automatic Temp. Compensation Range | 0.1–60.0 °C |
| Sample Temp. Range | 5–60 °C |
| Ambient Temp. Range | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Storage/Transport Temp. | −25–55 °C (electrode excluded |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | <5 W |
| Dimensions (L×W×H) | 142×125×155 mm |
| Panel Cutout | 138×138 mm |
| Weight | 1.6 kg |
| Brand | TimePower |
|---|---|
| Model | TP140 |
| Origin | Beijing, China |
| Manufacturer | TimePower Measurement & Control Co., Ltd. |
| Measuring Range | NaOH (0–10.00%), Na₂CO₃ (0–10.00%), HCl (0–10.00%), H₂SO₄ (0–20.00%), HNO₃ (0–15.00%), NaCl (0–20.00%) |
| Accuracy | ±2% F.S. |
| Resolution | 0.01% |
| Repeatability | ≤1% |
| Temperature Compensation Range | 0.1–60.0 °C |
| Sensor Type | Pt1000 RTD |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable) |
| Relay Outputs | 2 × SPST (AC220 V / 3 A or DC30 V / 3 A) |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Power Supply | AC 220 V ±10%, 50 Hz, <5 W |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 155×142×125 mm |
| Panel Cutout | 138×138 mm |
| Weight | 1.6 kg |
| Data Retention | >10 years (non-volatile memory) |
| Installation | Panel-mount / Wall-mount / Rack-mount |
| Electrode Mounting | Flow-through / Immersion / Flanged / In-line |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP140 |
| Price | Upon Request |
| Measurement Principle | Potentiometric pH sensing with temperature-compensated conductivity correlation for acid/base concentration estimation |
| Compliance Context | Designed for industrial process monitoring per ISO 5725 (accuracy/trueness), ASTM D1125 (electrical conductivity of water), and GLP-aligned data integrity requirements |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP150 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP151 |
| Price | Upon Request |
| Measurement Principle | Clark-type polarographic membrane electrode |
| Output Signals | 0–10 mA / 0–20 mA / 4–20 mA (selectable), load < 300 Ω |
| Relay Output | AC 220 V / 3 A or DC 30 V / 3 A |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Display | 128 × 64 LCD, Chinese interface |
| Measurement Range | 0.00–20.00 mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ≤1% |
| Accuracy | ±1.5% FS |
| Response Time (T90) | <5 min at 25 °C |
| Temperature Compensation Range | 0–60.0 °C |
| Sample Temperature Range | 5–60 °C |
| Ambient Temperature Range | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temperature | −25 to +55 °C (electrode ≥0 °C) |
| Enclosure Rating | IP65 |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| A/D Conversion | 24-bit |
| Microcontroller Architecture | Integrated low-power MCU |
| Housing Dimensions | 145 mm × 120 mm × 150 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 0.64 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | TP152 |
| Output Signals | (0–10) mA, (0–20) mA, (4–20) mA (selectable) |
| Load Impedance | < 300 Ω |
| Relay Output | AC 220 V / 3 A or DC 30 V / 3 A |
| Power Supply | AC (85–265) V, 45–65 Hz |
| Power Consumption | ≤ 15 W |
| Display | 128 × 64 LCD, Chinese interface |
| Measurement Range | (0.00–20.00) mg/L |
| Resolution | 0.01 mg/L |
| Repeatability | ≤ 1% |
| Accuracy | ±1.5% FS |
| Response Time (T90) | < 5 min at 25 °C |
| Temperature Compensation Range | (0.0–60.0) °C |
| Sample Temperature Range | (5–60) °C |
| Ambient Temperature Range | (5–45) °C |
| Relative Humidity | ≤ 90% RH (non-condensing) |
| Storage & Transport Temp. | (−25–55) °C (electrode ≥ 0 °C) |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 145 mm × 120 mm × 150 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 0.64 kg |
| Data Retention | > 10 years after power loss |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Laboratory-Grade Dew Point Meter |
| Model | TP205 |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | 5–60 °C |
| Accuracy | ±2 °C |
| Repeatability | ±0.2 °C |
| Dew Point Range | −100 to 0 °C (low-range sensor) or −60 to +20 °C (standard sensor) |
| Resolution | 0.01 °C (dew point) |
| Response Time (63% / 90%) | 90 s / 450 s |
| Gas Flow Rate | 0.1–0.4 L/min (H₂), 0.5–0.9 L/min (SF₆) |
| Pressure Measurement Range | 0–1 MPa |
| Sample Pressure Range | 0–10 bar |
| Probe Protection | Stainless Steel Sintered Filter |
| Storage Temperature | −40 to +70 °C |
| Relative Humidity Range | 0–100 %RH |
| Power Supply | AC 220 V / 50 Hz or DC 11.1 V Li-ion battery (auto-switching, overcharge/over-discharge protection) |
| Dimensions | 310 × 290 × 280 mm |
| Weight | 4.6 kg |
| Data Interface | RS232 / RS485 (optional) |
| Display | Full-color TFT touch screen |
| Data Logging | Internal digital storage with real-time timestamping |
| Battery Status | Digital charge-level indicator |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Laboratory-Grade Dew Point Meter |
| Measurement Principle | Chilled-Mirror (Optical Condensation) |
| Operating Temperature Range | −20 °C to +60 °C |
| Accuracy | ±1 °C (at −40 °C to +20 °C) |
| Repeatability | ±0.5 °C |
| Dew Point Range | −100 °C to +20 °C |
| Sensor | Vaisala DMT242 or DMT142 chilled-mirror probe |
| Response Time (t₆₃% / t₉₀%) | 90 s / 450 s |
| Pressure Range | 0–20 bar (absolute) |
| Sample Flow Rate | Flow-Insensitive Design |
| Output Interface | RS232 Serial Port |
| Power Supply | Rechargeable Internal Battery (≥8 h charging time with auto-cut-off protection) |
| Probe Protection | Stainless Steel Sintered Filter |
| Display | True-Color Touchscreen with Dual-Language UI (English & Chinese) |
| Data Logging | Real-Time Storage & Optional Thermal Printing |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TP205 |
| Product Category | Laboratory Dew Point Meter |
| Measurement Principle | Chilled-Mirror–Enhanced Semiconductor Sensor (Vaisala OEM Core) |
| Operating Temperature | −20 °C to +60 °C |
| Accuracy | ±2 °C (for dew point > −60 °C) |
| Repeatability | ±0.2 °C |
| Dew Point Range | −100 °C to 0 °C (low-range sensor) / −60 °C to +20 °C (standard sensor) |
| Response Time (t₆₃%/t₉₀%) | 90 s / 450 s |
| Resolution | 0.01 °C (dew point) |
| Sample Flow Rate | SF₆: 0.5–0.9 L/min |
| H₂ | 0.1–0.4 L/min |
| Pressure Range | 0–1 MPa |
| Probe Protection | Stainless Steel Sintered Filter |
| Power Supply | AC 220 V 50 Hz / DC 11.1 V Li-ion (auto-switching, overcharge/over-discharge protection) |
| Dimensions | 310 mm × 290 mm × 280 mm |
| Weight | 4.6 kg |
| Storage Temperature | −40 °C to +70 °C |
| Ambient Operating Conditions | 5–60 °C, 0–100 % RH |
| Data Interface | RS232/RS485 (optional) |
| Display | Full-color TFT touchscreen |
| Internal Memory | High-capacity digital storage with battery-level indicator |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Laboratory-Grade Dew Point Meter |
| Measurement Principle | Chilled-Mirror Condensation |
| Operating Temperature Range | −20 °C to +50 °C |
| Accuracy | ±0.2 °C |
| Repeatability | ±0.01 °C |
| Measurement Range | 0 °C to −60 °C (at ambient 10 °C) |
| Resolution | 0.01 °C |
| Equilibration Time | 3–5 min |
| Gas Flow Rate | 15–60 L/h |
| Gas Pressure Range | 1 kPa to 1 MPa |
| Display | Color LCD |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤70 W |
| Dimensions | 320 × 300 × 190 mm |
| Weight | 6.6 kg |
| Cooling Method | Four-Stage Peltier |
| Mirror Material | Corrosion-Resistant Coated Quartz |
| Optical Detection | Photoelectric Condensate Detection |
| Brand | Timepower |
|---|---|
| Model | TP210 |
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Type | Benchtop/Portable pH Analyzer |
| Measurement Range | 0.00–14.00 pH |
| Accuracy | ±0.02 pH |
| Resolution | 0.01 pH |
| Input Impedance | ≥1×10¹² Ω |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Compensation | Pt1000 sensor, 0–60 °C |
| Operating Temp. | 5–60 °C (sample), 5–45 °C (ambient) |
| Humidity | ≤90% RH (non-condensing) |
| Storage Temp. | −25–55 °C (electrode storage >0 °C) |
| Power | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤0.5 W |
| Dimensions | 80 × 30 × 175 mm |
| Weight | 0.26 kg |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Data Storage | Cyclic memory with auto-overflow management, >1 year retention after power loss |
| Auto-Stabilization Detection | Yes |
| Brand | Timepower |
|---|---|
| Model | TP210 |
| Origin | Beijing, China |
| Manufacturer | Timepower Instrument Co., Ltd. |
| Type | Domestic Portable pH Analyzer |
| Measurement Range | 0.00–14.00 pH |
| Accuracy | ±0.02 pH |
| Resolution | 0.01 pH |
| Input Impedance | ≥1×10¹² Ω |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Compensation Range | 0–60 °C |
| Temperature Sensor | Pt1000 |
| Operating Temp. (Sample) | 5–60 °C |
| Ambient Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temp. | −25–55 °C (electrode storage >0 °C) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤0.5 W |
| Dimensions | 80 × 30 × 175 mm |
| Weight | 0.26 kg |
| Display | 128×64 dot-matrix LCD, Chinese interface |
| Battery Life | Up to 8 h continuous operation after full charge |
| Data Storage | Cyclic memory with auto-overflow overwrite |
| Auto-Stabilization Detection | Yes |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP220 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Model | TP251 |
| Origin | Beijing, China |
| Manufacturer | Timepower Measurement & Control Equipment Co., Ltd. |
| Type | Polarographic (Clark-type) Membrane Electrode-Based Portable DO Meter |
| Measurement Range | 0.00–20.00 mg/L |
| Accuracy | ±1.5% F.S. |
| Resolution | 0.01 mg/L |
| Repeatability | ≤1% |
| Stability | ±1% F.S./4 h |
| Response Time (T90) | <5 min at 25°C |
| Temperature Compensation Range | 0.1–60.0°C |
| Sample Temp. Range | 5–60°C |
| Operating Ambient | 5–45°C, ≤90% RH (non-condensing) |
| Power | AC 220 V ±10%, 50 Hz |
| Battery Life | Up to 8 h continuous operation (internal rechargeable battery) |
| Dimensions | 162 × 82 × 33 mm |
| Weight | 0.2 kg |
| Display | 128×64 dot-matrix LCD with Chinese interface |
| Data Storage | Cyclic memory with >10-year data retention after power loss |
| A/D Converter | 24-bit |
| Temperature Sensor | Pt1000 integrated in probe |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Timepower (Producer) |
| Country of Origin | China |
| Model | TP301 / TP302 |
| Price | Upon Request |
| Feed Water for TP301 | Municipal Tap Water |
| Feed Water for TP302 | RO or Distilled Water |
| RO Permeate Conductivity | 0–50 µS/cm (Grade III Pure Water, compliant with GB/T 6682 and ASTM D1193 CAP/NCCLS Type III) |
| UPW Resistivity | 18.25 MΩ·cm @ 25°C (Grade I Ultra-Pure Water, compliant with GB/T 6682 and ASTM D1193 CAP/NCCLS Type I) |
| Silica (as SiO₂) | <0.01 ppm |
| Particles (>0.22 µm) | <1/mL |
| TOC | <10 ppb |
| Terminal Filtration | 0.22 µm MF Membrane |
| Cations (Fe, Cu, Al, Ni, Zn, Cr, Na, K) | <0.001–0.02 ppb |
| Anions (Cl⁻, NO₂⁻, NO₃⁻, SO₄²⁻) | <0.01–0.02 ppb |
| Heavy Metals (total) | <0.1 ppb |
| Operating Temperature | 5–40°C |
| Power Supply | 220 VAC / 50 Hz ±10% |
| Dimensions (W×D×H) | 600 × 470 × 520 mm |
| Weight | 40 kg |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP304 |
| Price | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP304 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP304 |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Display | 5.0-inch color touchscreen (Chinese interface) |
| Measurement Principle | Photometric colorimetry based on Lambert-Beer Law |
| Analytical Method | National Standard o-Phenanthroline Spectrophotometric Method |
| Measurement Range | 0.00–200 μg/L |
| Accuracy | ±3% F.S. |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1.5% F.S./4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Data Storage | Up to 256 records with auto-overflow overwrite |
| Calibration | Blank calibration and curve calibration supported |
| Light Source | Imported monochromatic cold light source |
| Compliance | Meets Chinese national standard GB/T 12149–2019 for iron determination in boiler water and steam-water systems |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP305 |
| Price | Upon Request |
| Display | 5.0-inch color touch LCD, Chinese interface |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Measurement Range | 0.00–200 μg/L |
| Accuracy | ±3% F.S. |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1.5% F.S./4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Light Source | Imported monochromatic cold light source |
| Calibration | Blank calibration & curve calibration per standard method |
| Compliance Method | National Standard Method using bis-cyclohexanone oxaldihydrazone (BCO) colorimetry |
| Data Storage | Cyclic memory for up to 256 records |
| Timing Function | Automatic countdown timer with alert |
| Optical Principle | Photometric colorimetry based on Lambert-Beer law |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP305 |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Display | 5.0-inch capacitive color touchscreen (Chinese UI) |
| Measurement Range | 0.00–200 µg/L |
| Accuracy | ±3% FS |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1% |
| Stability | ±1.5% FS / 4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Calibration Method | Blank calibration + dual-cyclohexanone oxaldihydrazone spectrophotometric method per Chinese national standard |
| Data Storage | Cyclic memory for up to 256 records |
| Light Source | Imported monochromatic cold LED source |
| Compliance | GB/T 6908–2018 (Boiler water and feedwater — Determination of copper content) |
| Brand | Timepower |
|---|---|
| Model | TP305 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Measurement Principle | Photometric Colorimetry (Bicinchoninone / DBCO Method) |
| Display | 5.0-inch TFT Touchscreen (Chinese UI) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Measuring Range | 0.00–200 μg/L Cu²⁺ |
| Accuracy | ±3% F.S. |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1.5% F.S. / 4 h |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Data Storage | 256-cycle circular memory |
| Calibration | Blank & Multi-point Curve Calibration |
| Compliance Method | GB/T 5750.6–2023 (Equivalent to ISO 8575:2017 for copper in water) |
| Light Source | Imported monochromatic cold LED (λ = 540 nm) |
| Sample Volume | ~10 mL per test |
| Standard Reagent | Dibenzoyl-1,2-dihydroxyethylene (DBCO), certified reference material traceable to NIM (National Institute of Metrology, China) |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP306 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TP306 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP306 |
| Pricing | Upon Request |
| Display | 5.0-inch color touchscreen (Chinese UI) |
| Measurement Principle | Photometric colorimetry based on molybdenum blue reduction method |
| Measuring Range | 0–200 µg/L and 0–2000 µg/L (selectable) |
| Accuracy | ±2% FS |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1% |
| Stability | ±1% FS/4h |
| Light Source | Imported monochromatic cold LED |
| Environmental Operating Temperature | 5–45 °C |
| Humidity Limit | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Data Storage | Cyclic memory for up to 256 records |
| Calibration | Blank calibration + optional curve calibration |
| Compliance | Implements national standard silica determination method (molybdenum blue spectrophotometry) |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | TP307 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP307 |
| Pricing | Available Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP307 |
| Pricing | Available Upon Request |