Online Reaction Analysis System
Filter
Showing 61–77 of 77 results
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC-BMP-II |
| Reactor Volume | 0.5 L (500 mL) |
| Max. Reactors per System | 15 |
| Gas Flow Range | 0–6000 mL/h |
| Resolution | 8 mL |
| Measurement Accuracy | ±0.01 mL |
| Temperature Control Range | Ambient to 95 °C (±0.1 °C) |
| Stirring Speed | 10–250 rpm (adjustable) |
| CO₂ Absorption Efficiency | >98% |
| CO₂ Absorption Vessel Capacity | 100 mL (80 mL of 3 M NaOH + indicator) |
| Power Supply | 24 V DC / 220 V AC adapter |
| Display | 7-inch color touchscreen |
| Compliance | Designed for ASTM D5210, ISO 11734, and EU Directive 2009/28/EC compliant BMP testing protocols |
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC-BMP-III |
| Application Fields | Environmental Engineering (Wastewater Treatment, Activated Sludge Assessment) |
| Gas Measurement Resolution | 3.5 mL |
| Gas Flow Range | 0–6000 mL/h |
| Reactor Volumes | 250 mL / 500 mL / 1000 mL |
| Maximum Concurrent Reactors per System | 3 / 6 / 9 / 12 / 15 / 20 channels |
| Temperature Control Range | Ambient to 95 °C (±0.1 °C accuracy) |
| Stirring Speed | 10–250 rpm (magnetically coupled, gas-tight) |
| CO₂ Absorption Efficiency | >98% (using 3 M NaOH) |
| Data Interface | 15″ capacitive touchscreen HMI with embedded PLC control (MCBIO-6000 platform) |
| Software Features | Real-time cumulative CH₄ volume & instantaneous production rate calculation, ASTM/ISO-compliant BMP reporting, GLP-aligned audit trail, USB data export, remote desktop & mobile app supervision |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MAY-2001HPO |
| Price | USD 4,050 (FOB Guangdong) |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Ra300-R4 |
| Origin | Guangdong, China |
| Concentration Range | 10 ppm – 99.9% |
| Measurement Temperature | −20 °C to 135 °C |
| Concentration Accuracy | ±10 ppm to ±0.1% (dependent on matrix and calibration) |
| Resolution | 0.01% |
| Sensor Technology | Soft X-ray & Visible Spectroscopy |
| Pressure Rating | ≤1 MPa |
| Environmental Operating Temperature | −10 °C to 130 °C |
| Output Signals | TCP/IP, RS-485/232 (digital), 2-channel relay outputs (high/low limit & fault alarms) |
| Power Supply | 220 V AC, <0.2 A |
| Ingress Protection | IP67 (wetted parts) |
| Display Options | 4.3″ or 8″ embedded touchscreen controller |
| Temperature Compensation | Automatic |
| Channel Capacity | 1–6 configurable detection channels (customizable) |
| Brand | ONUEE |
|---|---|
| Origin | Shenzhen, China |
| Model | LZS-003 |
| CO₂ Measurement Resolution | 1 ppm |
| Gas Flow Rate | 6000 mL/min (max system aggregate) |
| Reactor Volume | 2000 mL per unit |
| Maximum Number of Parallel Reactors | 72 |
| Temperature Control Range | 25–120 °C |
| Temp. Stability | ±1 °C |
| CO₂ Detection Principle | NDIR (Non-Dispersive Infrared), Multi-Range Auto-Switching (0–5000 / 0–20000 / 0–60000 ppm) |
| Accuracy | ≤±1% F.S. |
| O₂ Detection Principle | Electrochemical |
| Range | 0–21% vol |
| Accuracy | ±2% F.S. |
| Mass Flow Control | 0–300 mL/min |
| Accuracy | ±1.5% F.S. |
| Mass Flow Monitoring | 0–200 mL/min |
| Accuracy | ±1% F.S. |
| Power Supply | 220 V AC, 50 Hz (optional 380 V AC) |
| Max. Power Consumption | 6.8 kW |
| Dimensions (W×H×D) | 3082 × 1875 × 825 mm |
| Environmental Operating Range | 5–40 °C |
| Compliance | GB/T 20197–2006, GB/T 19277.1–2011, ISO 14855-1, ASTM D5338 |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RTK BRE |
| Pricing | Available Upon Request |
| Measurement Modes | Aerobic Oxygen Uptake Rate (OUR) & Anaerobic Gas Production Rate |
| Channel Capacity | Scalable Multi-Channel (8 channels × N modules) |
| Software-Controlled Autonomous Operation | Up to 6 months continuous unattended operation |
| Aerobic Measurement Precision | ±0.05 mg O₂ |
| Anaerobic Measurement Precision | ±0.03 mL gas |
| Data Logging Intervals | Configurable from 1 minute to 24 hours |
| Compliant Standards | OECD 301C, 301F, 302C, 209, 224, 311 |
| Application Flexibility | Liquid-phase (aqueous), solid-phase (compost/soil), and slurry-based biodegradation assays |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK CRM-18 |
| Pricing | Available Upon Request |
| Gas Measurement Principle | Gravimetric Micro-Calorimetric (GMC) Technology |
| Channels | 18 parallel reactors |
| Reactor Volume | 500 mL |
| Reactor Material | Borosilicate Glass |
| Stirring Options | Magnetic or Mechanical |
| CO₂ Absorption | Integrated or External 3 mol/L NaOH/KOH with pH indicator |
| Measurement Accuracy | ±1.0 mL per channel |
| Temperature & Pressure Compensation | Yes (converted to STP: 273.15 K, 101.325 kPa) |
| N₂ Compensation Function | Yes |
| Data Logging | Embedded Web Server with Auto-Save & Resume on Power Recovery |
| Compliance Standards | ASTM D5988-18, ISO 14851-2019, ISO 23977-2-2020, ISO 17556-2019, ISO 14853-2016, ISO 15985-2014, GB/T 40611-2021, GB/T 19276.1-2003, OECD 311, OECD 301C/F |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RTK MFC-12V/24V |
| Pricing | Upon Request |
| Channels | 12 or 24 |
| Voltage Range | 0–1 V |
| Voltage Resolution | 0.001 V |
| Brand | Rocktek |
|---|---|
| Model | RTK PBDA-300C |
| Origin | Hubei, China |
| Control Channels | 12 or 24 (expandable in increments of 12) |
| Temperature Range | Ambient +5 °C to 70 °C |
| Temp. Stability | ±2 °C |
| CO₂ Detection | 0–10,000 ppm (NDIR) |
| Accuracy | ±100 ppm (0–2000 ppm), ±500 ppm (>2000 ppm) |
| O₂ Detection | 0–25% vol (electrochemical) |
| Resolution | 0.1% vol |
| Mass Flow Controllers | 13 units |
| Range | 0–200 mL/min |
| Accuracy | ±0.3% FS (≤30% FS), ±1.0% FS (>30% FS) |
| Vessel Capacity | >3 L per stainless-steel reactor |
| Dimensions (12-channel) | 960 × 790 × 1050 mm |
| Dimensions (24-channel) | 960 × 1580 × 1050 mm |
| Compliance | EN 13432, ISO 14855-1, GB/T 19277.1 |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK-207 |
| Pricing | Upon Request |
| Temperature Range | 20–40 °C (Uniformity ≤ ±1 °C) |
| Illuminance | ≥10,000 lux |
| Humidity Range | 50–95% RH (Stability ≤ ±3% RH) |
| Chamber Volume | ≥150 L |
| Power Supply | 220 V, 50 Hz, Max. 750 W |
| Dimensions (W×D×H) | 600 × 650 × 1410 mm |
| Weight | 120 kg |
| Refrigeration | Hermetic Compressor with Modular Design, Delayed Start & Dual Pressure Protection |
| Interior | Stainless Steel with Adjustable Shelves |
| Air Circulation | Forced Convection via Stainless Steel Duct System |
| Control Interface | Touchscreen Display with Data Export Capability |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK-BMP |
| Price | Upon Request |
| Application Domain | Environmental Engineering (Wastewater Treatment, Activated Sludge Assessment) |
| Digestion Reactors | 18 × 500 mL (optional 1000 mL / 2000 mL, borosilicate glass) |
| Temperature Control | 25–99.9 °C (±0.15 °C), water bath, 2 kW heating, 25 L internal volume |
| Stirring | Brushless motor, 0–200 rpm, software-programmable speed & interval |
| CO₂ Absorption | 18 × 100 mL bottles, >98% efficiency with 3 M NaOH + pH indicator (optional) |
| Gas Measurement Principle | GMC Ultra-Micro Gas Measurement Technology |
| Gas Volume Resolution | 1.0 mL per channel |
| Standardization | Real-time correction to STP (273.15 K, 101.325 kPa) using integrated temperature & pressure sensors |
| Nitrogen Compensation | Automatic headspace and N₂-purge offset correction |
| Data Acquisition | ARM® Cortex™-based multi-core industrial controller, FPGA-accelerated I/O, web-based server architecture |
| Power Backup | Built-in UPS support for data retention during grid failure |
| User Access | Multi-user concurrent login with isolated experiment workspaces |
| Remote Access | Browser-based interface compatible with Windows, macOS, iOS, and Android over LAN |
| Brand | SIELINS |
|---|---|
| Model | XLZ-1090A |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Gas Channels | Up to 3 simultaneous analytes (e.g., CO, CO₂, CH₄, SO₂, NO + optional O₂) |
| Measurement Range (typ.) | CO: 0–2000 ppm |
| CO₂ | 0–1000 ppm |
| O₂ | 0–1% vol |
| Display | Color TFT LCD with capacitive touch interface |
| Output | 4–20 mA analog (isolated), 8 relay outputs (SPDT), RS232 (field-upgradable to RS485) |
| Response Time (T90) | ≤15 s (IR channels) |
| Stability | ±1% FS / 7 days |
| Repeatability | ±0.5% FS |
| Linearity Error | ±1% FS |
| Temp. Drift | ±1% FS (5–45 °C) |
| Pressure Compensation | Yes |
| Enclosure | 19″ (483 mm) rack-mount chassis |
| Certifications | Non-explosive (non-ATEX/IECEx) |
| Operating Ambient | 5–45 °C |
| Interference Rejection | ±1% FS under cross-gas interference |
| Brand | SIELINS |
|---|---|
| Model | XLZ-800 |
| Application | Cement Kiln Electrostatic Precipitator & Coal Mill Safety Monitoring |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–1000 ppm CO (configurable) |
| Accuracy | ±2% FS |
| Response Time (T90) | <30 s |
| Output Signals | 4–20 mA, Relay Alarms (SPDT), Digital Modbus RTU |
| Environmental Operating Range | −10 to +50 °C, ≤90% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Compliance | GB/T 18204.2–2014, ISO 12039, IEC 61508 SIL 2 capable |
| Power Supply | 220 VAC ±10%, 50/60 Hz |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | XLZ-900 |
| Output | 4–20 mA analog signal per gas component |
| Alarm Output | Dry contact (NO/NC) for concentration threshold violation |
| Communication Interface | RS-485 (Modbus RTU) |
| Application Domain | Microbial fermentation off-gas monitoring (O₂, CO₂, exhaust airflow) |
| Compliance Context | Designed for integration into GMP-compliant biomanufacturing environments with audit-ready data logging capability |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | SIELINS-904 |
| Power Supply | AC 220 V ±10%, 50 Hz ±1% |
| Total Power Consumption | 2000 VA |
| Probe Power | 800 VA |
| � | �热管线供电: 1500 VA |
| Compressed Air Requirement | 0.6 MPa, oil-free & dry |
| Ambient Temperature Range | −10–50 °C |
| Relative Humidity | <80% RH |
| Output Signal | Isolated 4–20 mA DC |
| Alarm Output | Dry contact (NO/NC configurable) |
| Sample Gas | Wet, dusty process gas containing CO |
| Primary Analyte | Carbon Monoxide (CO) |
| Compliance | Designed for industrial process monitoring per IEC 61511 functional safety principles (non-SIL certified), compatible with DCS/PLC integration under ISO 50001 energy management contexts |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TONSOER® Explorer I Platform |
| Pricing | Upon Request |
| Measurement Scope | Designed for spatially distributed, homogeneous process monitoring applications — e.g., Cu²⁺ and H₂SO₄ concentration monitoring in PCB manufacturing lines |
| Detection Principles | Potentiometric titration (acid-base, complexometric, precipitation, redox), photometric detection, and photometric titration |
| Sample Throughput | Base configuration (4 modules): ~10 min for 4 analytes |
| Standard configuration (8 modules) | ~10 min for 8 analytes |
| System Footprint | 3550 mm (W) × 650 mm (D) × 1850 mm (H) |
| Sample Handling Unit | 1250 mm (W) × 650 mm (D) × 1000 mm (H) |
| Analytical Unit | 620 mm (W) × 650 mm (D) × 1850 mm (H) |
| Power Supply | 198–242 V AC, 50 Hz ± 0.5 Hz, 2000 W |
| Operating Environment | 15–30 °C, RH 65 % ± 20 % (max daily temperature fluctuation ≤5 °C) |
| Control Interface | Windows-based desktop PC with ≥23-inch display |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Amine Concentration and H₂S/CO₂ Acid Gas Online Analyzer |
| Pricing | Available Upon Request |