| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ALT Online Ferrous Ion Monitoring Analyzer |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Model | ALT Online Free Acid & Total Acid Analyzer |
| Origin | Shanghai, China |
| Manufacturer | HOGON Scientific Instruments Co., Ltd. |
| Application | Real-time titrimetric monitoring of free acid (H₃PO₄, HNO₃) and total acid in electrolytic phosphating bath solutions |
| Measurement Principle | Potentiometric and colorimetric endpoint detection with dual-mode titration control |
| Display | 7-inch full-color TFT touchscreen interface |
| Processor | ARM Cortex-A8 |
| Connectivity | RS-232, TCP/IP, Modbus RTU/TCP |
| Compliance | Designed for industrial process environments per IEC 61000-6-2/4 EMC standards |
| Data Output | Structured ASCII or JSON via Ethernet |
| Maintenance Interval | ≥30 days between cleaning cycles under continuous operation |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT Online Sulfuric Acid Analyzer for Electroplating Baths |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | ALT Online Trivalent Chromium & Sodium Hypophosphite Analyzer for Electroplating Lines |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Ambient Operating Conditions | ≤90% RH, 10 °C minimum (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Protection Rating | IP55/IP65 (achieved when enclosure door is closed and latched) |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | ALT-1 |
| Pricing | Upon Request |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH (non-condensing), 10 °C minimum |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Ingress Protection Rating | IP55/IP65 (achieved with door closed and latched) |
| Titration Accuracy | Volumetric delivery precision of ±1 µL using 20 mL burette |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Ambient Operating Conditions | ≤90% RH, 10 °C minimum (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | ±0.001 pH (0–20 pH range) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Ingress Protection | IP55/IP65 (achieved when enclosure door is closed and latched) |
| Titration Accuracy | Volumetric delivery precision of ±1 µL using 20 mL burette |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C minimum (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Enclosure Rating | IP55/IP65 (with door locked), optional higher ratings available |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT-1 Online NaOH Concentration Analyzer |
| Pricing | Upon Request |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Operating Environment | ≤90% RH, 10°C minimum (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Ingress Protection | IP55/IP65 (when door is closed and latched) |
| Titration Accuracy | ±1 µL (with 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C minimum (non-condensing) |
| Resolution | Potentiometric: ±0.1 mV (−2000 to +2000 mV) |
| pH | ±0.001 pH (0–20 pH) |
| Photometric | ±0.003 Abs (0–1 Abs) |
| Ingress Protection | IP55 / IP65 (when door is closed and latched) |
| Titration Precision | ±1 µL volumetric control (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C minimum (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Ingress Protection | IP55 / IP65 (achieved when enclosure door is closed and latched) |
| Titration Accuracy | ±1 µL volumetric control (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C minimum (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Enclosure Rating | IP55/IP65 (achieved when door is closed and latched) |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ALT-1 |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH, 10 °C min (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV), pH: 0.001 pH (0–20 pH), Photometric: 0.003 Abs (0–1 Abs) |
| IP Rating | IP55/IP65 (when enclosure door is closed and latched) |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ALT-1-PH |
| Pricing | Upon Request |
| Detection Principle | Potentiometric and Colorimetric Acid-Base Titration |
| Analysis Frequency | Once per 20 minutes |
| RSD | ≤1% (Potentiometric), ≤2% (Colorimetric) |
| Detection Range | 0.01–10 mol/L H⁺ |
| Titration Precision | ±1 µL (using 20 mL burette) |
| Alarm Indicators | Dual-color LED for liquid level, data out-of-spec, reagent expiry, and system fault |
| Output Interfaces | Modbus TCP, RS-232/485, CAN, 4–20 mA analog |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH (non-condensing at 10 °C) |
| Wetted Materials | PTFE/FEP |
| Enclosure Rating | IP55 / IP65 (when door is closed and locked) |
| Dimensions (W×D×H) | 500 × 400 × 1600 mm |
| Power Supply | 100–220 V AC, 50–60 Hz, 200 W |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ALT-1-TZ |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | ALT-EDTA |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ALT-ORP |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT-PCB Online Copper Ion Analyzer |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ALT-PCB Online Sodium Persulfate Concentration Analyzer (for NPS, SPS, and APS) |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ALT-PCB |
| Pricing | Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ALT-PH Series |
| Pricing | Upon Request |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Environmental Operating Conditions | ≤90% RH (non-condensing), 10 °C minimum |
| Resolution | Potentiometric input: 0.1 mV (−2000 to +2000 mV) |
| pH | 0.001 pH (0–20 pH) |
| Photometric absorbance | 0.003 Abs (0–1 Abs) |
| Enclosure Rating | IP55/IP65 (achieved when door is closed and latched) |
| Titration Precision | ±1 µL volumetric delivery accuracy (20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ALT-SED |
| Pricing | Available Upon Request |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | HG-CuOnline |
| Pricing | Upon Request |
| Output Signals | Modbus TCP, RS-232/485, CAN, 4–20 mA |
| Operating Environment | ≤90% RH, 10 °C (non-condensing) |
| Resolution | Potentiometric: 0.1 mV (−2000 to +2000 mV) |
| pH | ±0.001 pH (0–20 pH) |
| Photometric | 0.003 Abs (0–1 Abs) |
| Ingress Protection | IP55/IP65 (when door is closed and latched) |
| Titration Accuracy | ±1 µL (using 20 mL burette) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Online Karl Fischer Coulometric Moisture Analyzer |
| Pricing | Upon Request |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Sample Pressure | Atmospheric (or pressurized via optional pressure regulator) |
| Sample Line | Φ1/8″ or 6–10 mm PFA tubing |
| Sample Flow Path | Standard single-channel |
| Sample Temperature Range | 5–60 °C |
| Reagent-Wetted Materials | Corrosion- and oxidation-resistant high-performance polymers |
| Nitrogen Purge | Optional micro-positive-pressure inert atmosphere |
| Enclosure Rating | IP55/IP65 (customizable) |
| Explosion Protection | Non-explosion-proof standard |
| Analyte Phase | Liquid samples only |
| Measurement Principle | Coulometric Karl Fischer titration |
| Auxiliary Functions | Multi-stream sampling module (1:N), reagent dosing control, anti-crystallization heating jacket |
| Detection Module | Potentiometric endpoint detection |
| Output Interfaces | Modbus TCP, RS-232/RS-485, CAN bus |
| Status Indicators | Dual-color LED (operational / alarm) |
| Measurement Range | Absolute water mass: 3 µg – 199 mg |
| Water concentration | 1 ppm – 100% w/w |
| Resolution | 0.01 µg (water mass) |
| Electrolysis Current | 0–400 mA |
| Max. Electrolysis Rate | 2241 µg/min |
| User Access Control | Three-tier permission system compliant with GMP/GLP requirements |
| Audit Trail | Full timestamped event logging including method changes, calibration actions, operator logins, and raw measurement data |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (PRC) |
| Model | GC-9560-HTP |
| Pricing | Upon Request |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | HK-5100 |
| Pricing | Upon Request |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-5200 |
| Quotation | Upon Request |
| Cooling Capacity | 4.5 kW |
| Refrigeration Power | 5 HP |
| Electrical Power Input | 6 kW |
| Circulating Pump Power | 1.5 kW |
| Max. Sample Inlet Temp | ≤40 °C |
| Outlet Temp Control | (25 ±1) °C |
| Total Sample Flow Rate | 1500 mL/min |
| Sample Points | 1–20 |
| Cooling Water Requirement | P ≤ 0.2 MPa, Q ≤ 6 t/h |
| Circulation Flow Rate | 12 L/h |
| Temperature Stabilization Time | ≤3 min for 0.35 ton coolant |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-5500 |
| Pricing | Upon Request |
| Heat Exchanger Area | 2 × 15–2 × 30 m² |
| Deionized Water Tank Volume | 2 m³ |
| Pump Configuration | Dual (1 active + 1 standby), H-(30–65)-30-2002, 2 × (5.5–7.5) kW |
| DI Water Flow Rate | 10–40 t/h |
| DI Water Outlet Temperature | ≤33 °C |
| DI Water Outlet Pressure | 0.2–0.6 MPa |
| Industrial Cooling Water Inlet Flow | 15–60 t/h |
| Industrial Water Inlet Temp | ≤33 °C |
| Industrial Water Inlet Pressure | 0.2–0.6 MPa |
| Power Supply | 380 VAC, 50 Hz |
| Dimensions (L×W×H) | 3200 × 2000 × 2300 mm |
| Weight | 3.2 t |
| Construction Material | AISI 304 stainless steel for all wetted parts |
| Heat Exchanger Type | Weld-free gasketed plate heat exchanger |
| Control Features | Low/high level alarms, dry-run protection, auto-refill solenoid valve, dual-pump redundancy |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Thermo Fisher specifications) |
| Model | Invitrogen™ EVOS™ S1000 |
| Pricing | Available upon Request |
| Brand | Kraemer Elektronik |
|---|---|
| Origin | Germany |
| Model | UTS 4.3 LAB |
| Gas Flow Rate | 2300 mL/min |
| Reactor Volume | 3 L |
| Maximum Number of Reactors per System | 12 |