Online Refractometer
Filter
Showing 1–30 of 47 results
| Brand | ACM |
|---|---|
| Origin | Austria |
| Model | LR.14 |
| Measurement Principle | Critical Angle Refractometry |
| Brix Range | 0–75 °Brix |
| Process Temperature Range | 0–50 °C |
| Output Signal | 4–20 mA / HART / Modbus RTU |
| IP Rating | IP65/IP67 (sensor housing) |
| Wetted Materials | 316L stainless steel, sapphire prism, FKM or EPDM seals |
| Compliance | ATEX/IECEx optional, FDA-compliant wetted materials, CE marked |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Fermentation Monitor 5100 |
| Measurement Range | 0–30 °Plato / 0–10 %v/v ethanol |
| Temperature Control Range | −20 °C to +100 °C |
| Wetted Materials | Stainless Steel 1.4404, PEEK, Sapphire (Al₂O₃, 99.997 % purity) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | L-Rix 4100 / L-Rix 5100 / L-Rix 5200 |
| Refractive Index Range | 1.31–1.54 |
| Accuracy | ±0.0002 nD (equivalent to ±0.1% w/w) |
| Temperature Control Range | −20 °C to 120 °C |
| Wetted Materials | Stainless Steel 1.4404, PEEK, Sapphire (Al₂O₃ – 99.997%), EPDM O-ring 60×3 (VARIVENT N, Shore A 70) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α |
| Measurement Range | Brix 0.0–80.0% (ATC) |
| Temperature Range | −15 to 160°C |
| Resolution | Brix 0.01% (0.00–9.99%), 0.1% (10.0–80.0%) |
| Accuracy | ±0.1% Brix, ±1°C |
| Temperature Compensation | 5–100°C (ATC) |
| Output | RS-232C & 4–20 mA |
| Prism Material | Synthetic Sapphire |
| Wetted Parts | SUS316L |
| IP Rating | IP67 |
| Power Supply | DC 24 V |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg (main unit only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α |
| Measurement | Brix (ATC) & Temperature |
| Accuracy | ±0.1% Brix, ±1°C/°F |
| Range | 0.00–80.00% Brix (ATC), -15–160.0°C |
| ATC Range | 5–100°C |
| Resolution | 0.01% (≤9.99%), 0.1% (>10.0%), 1°C/°F |
| Output | 4–20 mA DC, RS-232C |
| Sampling Interval | ~1 sec (configurable up to 5 intervals) |
| IP Rating | IP67 |
| Light Source | LED (≈589 nm, D-line equivalent) |
| Power | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Prism Material | Synthetic Sapphire |
| Body Material | SUS316L Stainless Steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α (Chlor-Alkali Industrial Application) |
| Measurement Principle | Refractive Index (Brix, ATC) |
| Accuracy | ±0.1% Brix, ±1°C/°F |
| Range | 0.00–80.00% Brix (ATC), -15–160.0°C |
| Temperature Compensation | 5–100°C |
| Output | 4–20 mA, RS-232C |
| IP Rating | IP67 |
| Light Source | LED (≈589 nm, sodium D-line equivalent) |
| Prism Material | Synthetic Sapphire |
| Cell Body Material | SUS316L Stainless Steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Response Interval | ~1 sec (configurable up to 5 intervals) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α (for Electrolyte & Polishing Liquids) |
| Measurement Range | 0.00–80.00% Brix (ATC) |
| Accuracy | ±0.1% Brix, ±1°C/°F Temperature |
| Temperature Compensation Range | 5–100°C |
| Operating Temp. | −15–160.0°C |
| Resolution | 0.01% Brix (≤9.99%), 0.1% Brix (≥10.0%) |
| Output | DC 4–20 mA, RS-232C (refractive index or Brix selectable) |
| Measurement Interval | 1 s (configurable to 5 intervals) |
| IP Rating | IP67 |
| Light Source | LED (≈589 nm, sodium D-line equivalent) |
| Prism Material | Synthetic Sapphire |
| Housing Material | SUS316L Stainless Steel |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α-DMF |
| Measurement Range | DMF 0.0–40.0% (w/w), Temperature −15 to 160°C (5 to 320°F) |
| Resolution | DMF 0.1%, Temperature 1°C/1°F |
| Accuracy | DMF ±0.3%, Temperature ±1°C/1°F |
| Wetted Materials | SUS 316L, Synthetic Sapphire Prism |
| IP Rating | IP67 |
| Output | 4–20 mA, RS-232C |
| Light Source | LED (≈589 nm, D-line equivalent) |
| Auto-Temperature Compensation Range | 5–100°C |
| Measurement Interval | ~1 s (configurable up to 5 presets) |
| Power Supply | DC 24 V (AC 100 V optional with AD-32 adapter) |
| Dimensions | 160 × 167 × 110 mm, Weight: 2.4 kg |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α-EG |
| Measurement Range | 0.0–90.0% EG (ATC) |
| Accuracy | ±0.4% EG, ±1°C/°F (Freezing Point & Temp) |
| Resolution | 0.1% EG, 1°C/°F |
| Temperature Compensation Range | 5–100°C |
| Process Temp Range | −15 to 160°C |
| Output | DC 4–20 mA, RS-232C |
| Prism Material | Synthetic Sapphire |
| Cell Body | SUS316L |
| IP Rating | IP67 |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg |
| Power Supply | DC 24 V (AC 100 V optional via AD-32 adapter) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α-EG |
| Measurement Principle | Refractometry |
| Output Signals | 4–20 mA analog + RS-232C digital |
| Installation Type | In-line or wall-mounted on pipe/tank |
| Compliance | Designed for industrial process environments per IEC 61000-6-2/6-4 EMC standards |
| Enclosure Rating | IP65 (standard) |
| Operating Temperature | 0–60 °C (process fluid), –10–50 °C (ambient) |
| Material Contact | SS316L prism and wetted parts |
| Calibration Support | Factory-calibrated for ethylene glycol/water solutions |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-BASEα |
| Measurement Range | Brix 0.0–53.0% |
| Resolution | 0.1% Brix |
| Accuracy | ±0.5% Brix |
| Temperature Range | 10–50°C (with automatic temperature compensation) |
| Dimensions & Weight | 90 × 90 × 58 mm, 820 g (main unit only) |
| Power Supply | DC 24 V |
| Compliance | CE-marked, RoHS-compliant, IP65-rated enclosure |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-Baseα |
| Measurement Principle | Abbe-type refractometry (critical angle method) |
| Measuring Range (Brix) | 0.0–33.0% |
| Resolution (Brix) | 0.1% |
| Accuracy (Brix) | ±0.5% |
| Temperature Range | 10.0–50.0°C |
| Power Supply | DC 24 V |
| Output Signals | RS-232C, 4–20 mA analog |
| Compliance | CE-marked, RoHS-compliant, suitable for industrial environments per IEC 61000-6-2/6-4 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-BASEα-03S |
| Measuring Range (Salinity) | 0.0–28.0 % |
| Resolution (Salinity) | 0.1 % |
| Accuracy (Salinity) | ±0.5 % |
| Output | RS-232C / 4–20 mA |
| Power Supply | DC 24 V |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-BASEα-04S |
| Measurement Range | Specific Gravity 1.000–1.217 |
| Resolution | 0.001 |
| Accuracy | ±0.005 |
| Power Supply | DC 24 V |
| Output Signals | RS-232C, 4–20 mA |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-BASEβ |
| Measurement Range | 0.0–93.0% Brix (ATC) |
| Temperature Range | 10–95°C (ATC) |
| Accuracy | ±0.2% Brix |
| Resolution | 0.1% Brix |
| Output | DC 4–20 mA / RS-232C |
| Prism Housing Material | Aluminum |
| IP Rating | IP67 |
| Dimensions (H×W×D) | 90×90×58 mm + probe length (200/300/500 mm) |
| Weight | 873 g (main unit only) |
| Power Supply | DC 24 V |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-BX/SALT α |
| Measurement Range | Brix 0.0–93.0%, Salt 0.00–15.00% |
| Resolution | Brix 0.1%, Salt 0.01% |
| Accuracy | Brix ±0.5% |
| Temperature Control Range | 4–95 °C |
| Wetted Materials | SUS 316L stainless steel + synthetic sapphire prism |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-ISα |
| Measurement Range | Brix 0.0–80.0%, Refractive Index (nD) 1.32000–1.49100 |
| Resolution | Brix 0.01% or 0.1%, Refractive Index 0.00001 or 0.0001 |
| Accuracy | Brix ±0.1%, Refractive Index ±0.0002 |
| Temperature Control Range | 5–100°C |
| Intrinsic Safety Rating | Ex ia IIB T3 Ga TA |
| Output | DC 4–20 mA or RS-232C |
| Power Supply | DC 24 V |
| Temperature Compensation Range | 5–100°C |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-ISα |
| Explosion Protection Rating | Ex ia IIB T3 Ga TA |
| Measurement Principle | Critical Angle Refraction |
| Measurable Parameters | Refractive Index (nD), Brix (% w/w), Concentration (%), Temperature |
| Refractive Index Range | 1.32000–1.49100 |
| Brix Range | 0.0–80.0% |
| Temperature Range | −15 to +160 °C |
| Refractive Index Resolution | 0.00001 |
| Brix Resolution | 0.01% or 0.1% (selectable) |
| Temperature Resolution | 0.1 °C |
| Refractive Index Accuracy | ±0.0002 |
| Brix Accuracy | ±0.1% |
| Temperature Accuracy | ±1 °C |
| ATC Range | 5–100 °C |
| Output Signals | DC 4–20 mA / RS-232C |
| Power Supply | DC 24 V |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-Isα |
| Catalog No. | 3700 |
| Measurement Parameters | Refractive Index (1.32000–1.49100), Brix (0.0–80.0%), Temperature (−15 to 160 °C) |
| Resolution | RI ±0.00001, Brix ±0.01% or ±0.1%, Temp ±0.1 °C |
| Accuracy | RI ±0.0002, Brix ±0.1%, Temp ±1 °C |
| ATC Range | 5–100 °C |
| Output | 4–20 mA DC or RS-232C |
| Power Supply | 24 V DC |
| Explosion Protection | Ex ia IIB T3 Ga TA |
| Compliance | ATEX, IECEx, EN 60079-0/-11 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-Isα-DMF |
| Explosion Protection Rating | Ex ia IIB T3 Ga TA |
| Measurement Principle | Refractive Index-Based Concentration Determination |
| Application | Real-time In-line DMF (N,N-Dimethylformamide) Solution Concentration Monitoring |
| Compliance | ATEX/IECEx Certified for Zone 0/1 Hazardous Areas |
| Enclosure Rating | IP67 |
| Process Connection | Clamp or Flange (DN25/DN40 Options Available) |
| Operating Temperature Range | −10 to 80 °C (Process Fluid) |
| Output Signal | 4–20 mA (HART Optional), RS-485 (Modbus RTU), Analog Voltage (0–5/0–10 V) |
| Material of Wetted Parts | 316L Stainless Steel, Sapphire Prism, FKM Seals |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-Isα-EG |
| Explosion Protection Rating | Ex ia IIB T3 Ga TA |
| Measuring Principle | Refractive Index (RI) |
| RI Range | 1.32000–1.49100 |
| EG Concentration Range | 0.0–53.0% w/w |
| Freeze Point Range | −50 to 0 °C (−58 to 32 °F) |
| Process Temperature Range | −15 to 160 °C (5 to 320 °F) |
| RI Resolution | 0.00001 |
| EG Resolution | 0.1% |
| Freeze Point Resolution | 1 °C / 1 °F |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| RI Accuracy | ±0.0002 |
| EG Concentration Accuracy | ±1.0% |
| Freeze Point Accuracy | ±1 °C / ±1 °F |
| Temperature Accuracy | ±1 °C / ±1 °F |
| Temp. Compensation Range | 5–100 °C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-Isα-Ethanol (W/W) |
| Explosion Protection Rating | Ex ia IIB T3 Ga TA |
| Measurement Principle | Refractive Index → Ethanol Mass Concentration (w/w%) |
| Compliance | ATEX, IECEx, UL 60079-0/-11 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-ISα-Methanol |
| Explosion Protection Rating | Ex ia IIB T3 Ga TA |
| Measurement Principle | Critical Angle Refractometry |
| Temperature Compensation | Automatic (PT1000 sensor integrated) |
| Output Signals | 4–20 mA (HART optional), RS-232C |
| Process Connection | DN25/DN40 flange or tri-clamp (SUS316L wetted parts) |
| Operating Temperature | –10 to +60 °C (process fluid) |
| IP Rating | IP67 (sensor head), IP65 (transmitter) |
| Compliance | ATEX Directive 2014/34/EU, IEC 60079-0, IEC 60079-11, ISO 21873-1 (for hazardous area instrumentation) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-Isα-PG |
| Explosion Protection Rating | Ex ia IIB T3 Ga TA |
| Measurement Principle | Total Internal Reflection Refractometry |
| Output Signal | 4–20 mA / RS-485 (Modbus RTU) |
| Process Connection | DN25/DN40 Flange or Clamp |
| Operating Temperature | −10 to 70 °C (Process Fluid) |
| IP Rating | IP67 |
| Material | 316L Stainless Steel Housing & Sapphire Prism |
| Calibration Range | 0–100 wt% Propylene Glycol (refractive index 1.333–1.432) |
| Accuracy | ±0.1 wt% PG (typical, with temperature compensation) |
| Response Time | < 3 s (90% step change) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-TANKα-SW(FER) |
| Measurement Range | Salt (NaCl) 0.00–28.0% w/w |
| Temperature Range | −15 to +160 °C |
| Salt Resolution | 0.01% (0.00–9.99%), 0.1% (10.0–28.0) |
| Temperature Resolution | 1 °C |
| Salt Accuracy | ±0.1% |
| Temperature Accuracy | ±1 °C |
| Temperature Compensation Range | 5–100 °C |
| Output | DC 4–20 mA / RS-232C |
| Response Time | ~1 s |
| Power Supply | DC 24 V |
| Prism Material | Synthetic Sapphire |
| Sample Cell Material | SUS316L |
| Ingress Protection | IP67 |
| Dimensions | 160 × 167 × 110 mm |
| Weight | 2.4 kg (main unit only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-2 |
| Measurement Range | Brix 45.0–93.0% |
| Temperature Range | 9.0–99.9°C |
| Resolution | Brix ±0.1%, Temperature ±0.1°C |
| Accuracy | Brix ±0.2%, Temperature ±1.0°C |
| Sample Volume | 0.3 mL |
| Measurement Time | 3 seconds |
| Temperature Compensation | Automatic (ATC), 10–100°C |
| Environmental Rating | IP65 |
| Power Supply | 2 × AAA batteries |
| Dimensions | 55(W) × 31(D) × 109(H) mm |
| Weight | 100 g (body only) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-3 |
| Measurement Range | Brix 0.0–93.0% |
| Temperature Range | 9.0–99.9°C |
| Brix Resolution | 0.1% |
| Temperature Resolution | 0.1°C |
| Accuracy | ±0.1% Brix, ±1.0°C |
| Automatic Temperature Compensation (ATC) | Yes (10–100°C) |
| Sample Volume | 0.3 mL |
| Measurement Time | Approx. 3 seconds |
| Power Supply | 2 × AAA batteries |
| IP Rating | IP65 |
| Dimensions | 55(W) × 31(D) × 109(H) mm |
| Weight | 100 g (body only) |
| Operating Ambient Temperature | 10–40°C |
| Calibration Standards Available | 10–60% sucrose solutions (certified ±0.03–±0.05% Brix) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-α |
| Brix Range | 0.0–85.0% |
| Temperature Range | 9.0–99.9°C |
| Brix Resolution | 0.1% |
| Temperature Resolution | 0.1°C |
| Accuracy (Brix) | ±0.2% |
| Accuracy (Temperature) | ±1.0°C |
| Sample Volume | 0.3 mL |
| Measurement Time | 3 seconds |
| Power Supply | 2 × AAA batteries |
| IP Rating | IP65 |
| Dimensions | 55(W) × 31(D) × 109(H) mm |
| Weight | 100 g (body only) |
| Automatic Temperature Compensation (ATC) | Yes |
| Operating Ambient Temperature | 10–40°C |
| Measured Sample Temperature Range | 10–100°C |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAN-1 DC |
| Measurement Principle | Total Internal Reflection (TIR) Refractometry |
| Output | Brix (%) and Temperature (°C) |
| Sampling Interval | 30 seconds |
| Mounting | Clamp-on, Direct Wall Mounting on Process Vessel |
| Compliance | IP65 Rated Enclosure |
| Power Supply | 24 VDC |
| Analog Output | 4–20 mA (isolated) |
| Digital Interface | RS-485 (Modbus RTU) |
| Operating Temperature Range | 0–60 °C (process fluid) |
| Refractive Index Range | 1.333–1.500 RIU |
| Brix Range | 0–50 % |
| Temperature Compensation | Built-in Pt100 RTD Sensor |
| Material Contact | 316L Stainless Steel Prism & Housing |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PRM-100α DX |
| Measurement Range | nD 1.32000–1.55700, Brix 0.00–100.00% |
| Resolution | nD 0.0001 / 0.00001, Brix 0.1% / 0.01% |
| Accuracy | ±0.00010 (nD), ±0.05% (Brix) |
| Operating Temperature | 5–100°C |
| Output | RS-232C, 4–20 mA |
| IP Rating | IP67 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Display Unit Dimensions | 19.2 × 10 × 24 cm, 3.3 kg |
| Sensor Unit Dimensions | 10.8 × 17.26 × 10.8 cm, 2.6 kg |