| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Pathlength Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Internal Memory | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing | Powder-coated steel enclosure |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Saybolt (ASTM D6045/D156), ASTM D1500, Pt-Co/Hazen/APHA (ASTM D1209), CIE XYZ/Lab values, spectral reflectance data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Measurement Principles | Tristimulus colorimetry (CIE 1931 XYZ), spectral reflectance (31-wavelength LED array) |
| Standards Supported | ASTM D1500 (Petroleum), ASTM D156 (Saybolt), ASTM D5386 (Color by Instrument), ISO 2764 (Pt-Co/Hazen/APHA), ISO 4630 (Gardner), CIE L*a*b*, CIE Yxy, ΔE*ab |
| Display | 7-inch TFT LCD with multi-language UI (including English, Chinese, Spanish, French, German) |
| Interface | USB 2.0, 10/100 Mbps Ethernet (LAN), RS-232 optional |
| Data Storage | Internal memory for ≥10,000 results with GLP-compliant audit trail (date, time, operator ID, sample ID, method ID) |
| Sample Compartment | Removable stainless-steel cell holder, compatible with 10–50 mm pathlength cuvettes (glass, quartz, disposable plastic) |
| Calibration | Factory-calibrated with NIST-traceable liquid standards |
| Enclosure | IP54-rated stainless-steel chassis with chemical-resistant coating |
| Software | Lovibond ColorControl v5.x (Windows), supports CIE chromaticity diagrams, spectral curve overlay, deviation analysis (ΔL*, Δa*, Δb*, ΔE*ab), custom standard creation, and 21 CFR Part 11–compliant user access control |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/3 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability (CIE x,y) | ±0.0004 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 pixel backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Housing Material | Steel enclosure with textured epoxy coating |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/3 |
| Measurement Principles | Tristimulus colorimetry (CIE 1931 XYZ), Gardner, FAC, APHA/Pt-Co, Saybolt |
| Display | High-contrast backlit LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Compliance | ISO/IEC 17025 traceable standards support (ASTM D1500, ASTM D6166, ISO 4630, ISO 27875, ISO 6271), GLP-compliant data logging |
| Sample Handling | Removable stainless-steel measurement cell, flow-through cuvette option available |
| Software | Included Lovibond Colour Control Software (Windows-compatible), CIE chromaticity diagram visualization, spectral reflectance/data export (CSV, XML), remote instrument control |
| Data Management | User ID, sample ID, timestamp, method ID, and deviation metrics (ΔE*, Δa*, Δb*, saturation ratio, hue angle offset) stored per measurement |
| Enclosure | Corrosion-resistant stainless-steel housing |
| Power | 100–240 V AC, 50/60 Hz |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/4 |
| Measurement Principles | Tristimulus colorimetry (CIE 1931 XYZ), spectral reflectance/transmittance analysis |
| Standard Scales | EBC, ASBC, Gardner, Saybolt, Pt-Co (APHA), ISO 27677, ASTM D1209/D1500/D5386/D6166 |
| Display | Backlit LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Software | RCMSi Remote Calibration & Maintenance System, Lovibond Color Control Software v5.x |
| Compliance | ISO/IEC 17025 traceable calibration standards, ISO 9001-certified reference materials, GLP-compliant data logging (date/time/operator ID/sample ID) |
| Sample Handling | Removable stainless-steel cuvette chamber, compatible with 10–50 mm pathlength cells (standard and flow-through options) |
| Housing | Corrosion-resistant stainless steel chassis |
| Data Output | CSV, XML, PDF reports |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/5 |
| Compliance Standards | EP, USP, Pt-Co/Hazen/APHA, CIE L*a*b*, CIE XYZ, Spectral Data |
| Interface | USB & LAN (RCMSi Remote Calibration and Maintenance System) |
| Display | Large backlit LCD with multilingual UI (including Chinese) |
| Sample Holders | Compatible with multiple pathlength cuvettes (10–50 mm), optional flow-through cell |
| Construction | Stainless steel measurement chamber, chemical-resistant housing |
| Software | Included Color Control Software for spectral visualization, CIE chromaticity diagrams, data export, instrument remote control, GLP-compliant reporting |
| GLP Features | Date/time stamp, user ID, sample ID, audit trail, password protection |
| Customization | User-defined color standards, selectable display parameters, language selection, access-level passwords |
| Delta-E & Bias Analysis | Quantitative deviation reporting (ΔL*, Δa*, Δb*, ΔE*ab, hue angle, saturation ratio, bias factor) |
| Calibration | Certified liquid standards (ISO/IEC 17025 traceable per ASTM D1209, D5386 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/6 |
| Measurement Principles | Absorption photometry at fixed wavelengths & full-spectrum reflectance/transmittance |
| Standard Methods Supported | Pt-Co/Hazen/APHA, Gardner, Saybolt, ASTM D1209, ASTM D5386, ISO 6271, ISO 2761, CIE L*a*b*, CIE XYZ, Klett (Blue Filter KS-42), Hess-Ives |
| Display | 7-inch high-resolution TFT LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0, 10/100 Mbps Ethernet (LAN), RS-232 optional |
| Data Storage | Internal memory for ≥2,000 measurements with GLP-compliant metadata (date/time, operator ID, sample ID, method ID) |
| Compliance | ISO/IEC 17025 traceable calibration standards available |
| Sample Format | Compatible with 10–50 mm pathlength glass or quartz cuvettes |
| Construction | Stainless steel optical chamber housing with chemical-resistant anodized aluminum chassis |
| Light Source | Long-life halogen tungsten lamp with stabilized power supply and automatic intensity compensation |
| Wavelength Range | 380–780 nm (full-spectrum mode) |
| Repeatability | ≤0.1 ΔE*ab (CIE 1976) for stable samples under controlled conditions |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/7 |
| Measurement Standards | ICUMSA, Pfund, Series 52 (Brown), CIE L*a*b*, Spectral Reflectance/Transmittance |
| Interface | USB & LAN |
| Display | Large backlit LCD |
| Language Support | Multilingual (including Chinese) |
| GLP Compliance | Date/Time stamp, Sample ID, Operator ID logging |
| Construction | Stainless steel measurement cell housing |
| Cell Compatibility | Standard cuvettes (10–50 mm pathlength), optional flow-through cell |
| Software | Included Lovibond Colour Control Software (CIE chromaticity diagrams, spectral data export, remote instrument control) |
| Calibration | Certified liquid standards (ISO/IEC 17025 traceable per ASTM D1209, D1500, D5386 |
| Remote Maintenance | RCMSi Network Verification System |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/8 |
| Measurement Standards | ADMI, Pt-Co/Hazen/APHA, CIE L*a*b*, CIE XYZ, Spectral Data (380–780 nm, 10 nm intervals) |
| Display | 7-inch TFT LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Compliance | ISO 9001, ISO/IEC 17025 (via certified reference standards), ASTM D1209, ASTM D5386, ISO 6271, ISO 2211 |
| GLP Support | Date/time stamp, sample ID, operator ID, audit trail export |
| Sample Cell Compatibility | 10–50 mm pathlength cuvettes (rectangular, round, flow-through optional) |
| Housing | Stainless steel chassis with chemical-resistant anodized aluminum front panel |
| Calibration | RCMSi Remote Calibration Management System enabled |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/9 |
| Measurement Principle | Tristimulus Filter-Based Photometry |
| Light Source | Tungsten Halogen Lamp |
| Standard Cuvette | 10 mm Pathlength Glass Cell |
| Supported Color Scales | Lovibond®, Hunter Lab, CIELAB (L*C*h°), CIE XYZ, CIE Yellowness Index (YI), CIE Whiteness Index (WI), Spectral Data Output (31-point, 400–700 nm) |
| Interface | RS-232 & USB |
| Software Included | RCMSi Calibration & Data Management Suite for Windows |
| Compliance | ISO 4630 (Petroleum Products), ISO 27677 (Beer), AOAC Official Methods, ASTM D1209/D5386/D6290 |
| Calibration | Factory-Calibrated with NIST-Traceable Standards |
| Dimensions | 280 × 220 × 180 mm |
| Weight | 4.2 kg |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 / PFXi950 / PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Colorimetric Repeatability | Δx,y ≤ ±0.0002 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–153 mm (0.004–6 in) |
| Filter Set | 16 Interference Filters |
| Data Storage Capacity | 100,000 Measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 Backlit LCD |
| Keypad | 23 Membrane Keys with Audible Feedback |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Power Supply | 90–240 V AC (External Adapter) |
| Dimensions | 515 × 196 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| GLP Features | Timestamped Audit Trail, User ID, Sample ID, Calibration Log |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950/P |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Path Length Range | 0.1–153 mm (0.004–6 in) |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Built-in Color Scales | ASTM D1500 (Petroleum), Saybolt, CIE L*a*b*, L*C*h*, Yellowness Index (ASTM E313), Whiteness Index (CIE/ISO 11475), and Spectral Data Output |
| Calibration | One-Touch Automatic Baseline Calibration |
| Data Storage Capacity | 100,000 measurements |
| Interface Options | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback, polyester overlay |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Housing | Steel chassis with textured epoxy coating |
| Dimensions (W×H×D) | 515 × 195 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heated Cell Holder | Up to 95 °C temperature control |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Optional Heater | Up to 95 °C |
| Operating Voltage | 90–240 VAC (external power supply) |
| Enclosure | Steel housing with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Lovibond RYBN, AOCS, Gardner, Pt-Co/Hazen/APHA, FAC, Chlorophyll A/B, β-Carotene, Iodine, Hess-Weis, Klett (Blue filter KS-42), Kreis, CIE XYZ/L*a*b*, spectral reflectance data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 Automated Colorimeter |
| Optical Path Length | Up to 153 mm (6") |
| Compliance Standards | AOCS, ASTM D1500, ASTM D1209, ISO 2761, ISO 4630, ISO 6271, USP <631>, CIE 1931 & CIE 1976 (L*a*b*) |
| Data Interfaces | USB 2.0, 10/100 Mbps Ethernet (LAN) |
| Display | High-contrast backlit LCD with multilingual GUI (including English, German, French, Spanish, Chinese) |
| Software | Windows-based Lovibond ColorSoft v5.x with GLP audit trail, user management, and RCMSi remote calibration verification |
| Light Source | Tungsten-halogen lamp (replaceable) |
| Construction | Stainless steel housing with chemical-resistant coating |
| Optional Accessories | Integrated sample heater (for solid-to-liquid transition), custom filter sets, 1", 5.25", 10 mm, and 100 mm pathlength cells |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | RT700 |
| Measurement Principles | CIE-compliant 0°/d geometry (diffuse illumination, 0° viewing) |
| Illuminants | D65, A, C, F2, F7, F11 |
| Observer Angle | 2° and 10° standard observer |
| Color Spaces | CIE XYZ, Yxy, L*a*b*, Hunter LAB, L*C*h°, CMC (l:c), CIE94, DIN6172, Whiteness (CIE, Ganz, ASTM E313), Yellowness (ASTM D1925, E313), Delta E (ΔE*ab, ΔE00, ΔE94) |
| Repeatability | ≤0.08 ΔE*ab (white tile, 10 readings) |
| Lamp Type | Tungsten-halogen (long-life, stable output) |
| Aperture Options | 8 mm, 12 mm, 20 mm (user-selectable) |
| Display | High-contrast LCD with intuitive icon-based interface |
| Connectivity | USB port for data export and firmware updates |
| Compliance | ISO 5-4:2022, ISO 7724-1:2022, ASTM D2244, ASTM E308, CIE No. 15:2018 |
| Software Compatibility | OnColor™ v5.x (Windows-based, supports GLP audit trail, user access levels, report generation per ISO/IEC 17025) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | RT850I |
| Instrument Type | Integrating Sphere Spectrophotometer |
| Measurement Geometry | d/8° (diffuse illumination / 8° viewing angle), compliant with CIE No. 15, ISO 7724-1, ASTM E308, and DIN 5033-7 |
| Illuminants | D65, A, C, F2, F7, F11 |
| Observer Angle | 10° standard observer |
| Wavelength Range | 400–700 nm |
| Optical Resolution | 10 nm |
| Repeatability | ΔE*ab < 0.02 (white tile, 10 readings) |
| Inter-instrument Agreement | ΔE*ab < 0.15 (BCRA Series II tiles) |
| Sample Port Diameter | 25 mm (standard), optional 8 mm & 4 mm apertures |
| Data Output | CIE L*a*b*, L*C*h*, ΔE*ab, ΔE*cmc, ΔE*94, ΔE*00, Yxy, XYZ, spectral reflectance curves |
| Compliance | CE, UKCA, RoHS |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | Germany |
| Model | RT850i |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Sample Port Options | 3 selectable apertures |
| UV Filter | Optional |
| Preview Imaging System | Built-in real-time sample positioning camera |
| Connectivity | USB 2.0 |
| Software | OnColor™ PC software suite |
| Compliance | Designed for ISO 7724, ASTM E308, CIE No. 15, DIN 5033, and ISO 11664 colorimetric standards |
| Sample Compatibility | Opaque solids, translucent plastics, liquids (in cuvettes), powders (with accessory holders), textiles, coatings, glass, petroleum products |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TG268 |
| Type | Automatic Gloss Meter |
| Measurement Angles | 20°, 60°, 85° |
| Measurement Areas (mm) | 20°: 10×10, 60°: 9×15, 85°: 5×36 |
| Measurement Ranges | 20°: 0–2000 GU, 60°: 0–1000 GU, 85°: 0–160 GU |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–2000 GU) |
| Reproducibility | ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU), ±0.5% GU (100–2000 GU) |
| Geometry | CIE 1931 Standard Observer (2°), Illuminant C |
| Compliance | ISO 2813, ASTM D523, ASTM D2457, GB/T 9754 |
| Response Time | 1.0 s |
| Display | 3.5″ TFT capacitive touchscreen |
| Data Storage | 1,000 readings (Basic), 5,000 (Statistical & Continuous modes) |
| Interface | USB, RS-232 |
| Power | Rechargeable 3200 mAh Li-ion battery (up to 10,000 measurements per charge) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Dimensions | 160 × 75 × 90 mm |
| Weight | 350 g |
| Software | OnShade QC Suite (GLP-compliant reporting, audit trail, export to CSV/PDF) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TG268/60 Gloss Meter |
| Measurement Angles | 20° / 60° / 85° (TG268) |
| Compliance | ISO 2813, ASTM D 523, ASTM D 2457, GB/T 9754 |
| Measurement Area | 20°: 10 × 10 mm |
| 60° | 9 × 15 mm |
| 85° | 5 × 3 mm (TG268) |
| 60° | 9 × 15 mm (TG60) |
| Gloss Range | 20°: 0–2000 GU |
| 60° | 0–1000 GU |
| 85° | 0–160 GU (TG268) |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–2000 GU) — TG268 |
| Reproducibility | ±0.2 GU / ±0.5 GU / ±0.5% GU across ranges |
| Measurement Time | 1.0 s (TG268), 0.5 s (TG60) |
| Display | 3.5-inch TFT true-color capacitive touchscreen |
| Data Storage | Basic mode: 1,000 readings |
| Statistical & Continuous modes | 5,000 readings each |
| Interface | USB & RS232 |
| Power | 3200 mAh Li-ion battery (≥10,000 measurements per charge, ~8 h runtime) |
| Dimensions | 160 × 75 × 90 mm |
| Weight | 350 g |
| Operating Environment | 0–40 °C, <85% RH (non-condensing) |
| Storage | −20–50 °C |
| Standard Accessories | Calibration tiles (gloss standards), OnShade QC software, AC adapter, USB cable, user manual |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | TG60 |
| Measurement Angle | 60° |
| Compliant Standards | ISO 2813, ASTM D523, ASTM D2457, GB/T 9754 |
| Measuring Area | 9 mm × 15 mm |
| Gloss Range | 0–300 GU |
| Resolution | 0.1 GU |
| Repeatability | ±0.1 GU (0–10 GU), ±0.2 GU (10–100 GU), ±0.2% GU (100–300 GU) |
| Reproducibility | ±0.2 GU (0–10 GU), ±0.5 GU (10–100 GU), ±0.5% GU (100–300 GU) |
| Illuminant | CIE Standard Illuminant C |
| Observer Angle | 2° |
| Measurement Time | 0.5 s |
| Dimensions | 160 mm × 75 mm × 90 mm |
| Weight | 350 g |
| Display | 3.5-inch TFT capacitive touchscreen |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Power | Rechargeable 3200 mAh Li-ion battery (up to 10,000 measurements per charge) |
| Interface | USB & RS-232 |
| Data Storage | 1,000 readings (basic mode) |
| Software | OnShade QC software with GLP-compliant reporting and export functionality |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TLC120/60 |
| Light Sources | CIE Illuminant A (2856 K), D65 (6500 K), TL84 (4000 K), UV (365 nm), CWF (4150 K), TL83/U30 (3000 K) |
| Dimensions (TLC120) | 1310 × 600 × 800 mm |
| Weight (TLC120) | 65 kg |
| Dimensions (TLC60) | 710 × 530 × 570 mm |
| Weight (TLC60) | 38 kg |
| Compliance | ASTM D1729, ISO 3664:2009, DIN 6173-2, BS 950-1, ANSI IT8.7/2 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TR 520 / TR 500 |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Combined LED + UV |
| Spectral Range | 400–700 nm |
| Repeatability | TR520 (MAV/SCI): ΔE* ≤ 0.03 |
| TR500 (MAV/SCI) | ΔE* ≤ 0.05 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | TR520 / TR500 |
| Instrument Type | Handheld Colorimeter |
| Optical Geometry | d/8° integrating sphere |
| Light Source | LED with UV |
| Spectral Range | 400–700 nm |
| Wavelength Interval | 10 nm |
| FWHM | 10 nm |
| Aperture Options | Dual (10 mm / 8 mm & 5 mm / 4 mm) |
| Observer Angle | 2° / 10° |
| Illuminants | D65, A, C, D50, D55, D75, F1–F12 |
| Color Spaces | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter Lab |
| Color Difference Formulas | ΔE*ab, ΔE*uv, ΔE*94, ΔE*CMC (2:1), ΔE*CMC (1:1), ΔE*00, ΔE (Hunter) |
| Whiteness Index (WI) | ASTM E313, CIE/ISO, AATCC, Hunter |
| Yellowness Index (YI) | ASTM D1925, ASTM E313 |
| Tint Index (TI) | ASTM E313, CIE/ISO |
| Repeatability (MAV/SCI) | ΔE* ≤ 0.03 (TR520), ΔE* ≤ 0.05 (TR500) |
| Inter-instrument Agreement (MAV/SCI) | ΔE* ≤ 0.15 (TR520), ΔE* ≤ 0.20 (TR500) |
| Measurement Time | 2.6 s |
| Display | 3.5″ color TFT-LCD touchscreen |
| Battery Life | Up to 5,000 measurements or 8 h continuous use |
| Dimensions | 184 × 77 × 105 mm |
| Weight | 600 g |
| Operating Environment | 0–40 °C, 0–85 % RH (non-condensing), < 2000 m altitude |
| Storage | −20–50 °C, 0–85 % RH (non-condensing) |
| Data Storage | 2,000 standards + 20,000 samples |
| Interface | USB |
| Software | Included (color analysis, SPC, spectral visualization, pass/fail reporting) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Material | Optical Glass (W600, W680) or Borosilicate Glass (W600-B) |
| Dimensions | 21 mm × 40 mm (W600 series) |
| Max. Operating Temperature | 40 °C (optical glass), 100 °C (borosilicate) |
| Compatible Instruments | Lovibond PFXi/PFX-195, 880, 950, 995, Model F, Comparator 2000+, Comparator 3000 |
| Pathlength Options | 2.5 mm to 6" (6.35 mm to 152.4 mm), including fractional inch and metric increments |
| Light Path Tolerance | ±0.05 mm per ISO 3664:2009 reference compliance |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Lovibond® Comparator System 2000 |
| Price | Upon Request |
| Brand | Lovibond® (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Product Type | Certified Liquid Color Reference Standards |
| Compliance | AOCS, ASTM D1209/D5386/D6166, ISO 6271, EBC 1.3, Gardner ASTM D1544, Pt-Co (APHA/Hazen) ASTM D1209, Saybolt ASTM D156 |
| Format | 5¼" (133 mm) cylindrical glass cells |
| Shelf Life | 12 months from date of manufacture |
| Traceability | NIST-traceable spectrophotometric validation |
| Packaging | Individually labeled, amber glass vials with tamper-evident seals |
| Uncertainty | ±0.1 color unit (RYBN), ±1 APHA unit (Pt-Co), ±0.2 Gardner unit |
| Brand | Lovibond® (Tintometer®) |
|---|---|
| Origin | United Kingdom |
| Product Type | Certified Reference Filter Sets for Visual and Instrumental Color Measurement |
| Compliance | AOCS, ASTM, EBC, EP, USP, Pfund, Gardner, Saybolt, Pt-Co/Hazen, FAC, CIE xyY, IP Units, Klett, β-Carotene, Chlorophyll A, FAC, EBC Brown/Yellow/Green/Red/Yellow Series |
| Configuration | Pre-assembled, instrument-specific filter kits with NIST-traceable calibration certificates |
| Certification | Individually certified with measured color values and stated uncertainty per ISO/IEC 17025-accredited methodology |
| Brand | Inframet |
|---|---|
| Origin | Poland |
| Model | LS-MAH |
| Light Source Type | Tungsten-Halogen |
| Spectral Range | 400–2000 nm |
| Color Temperature | 2856 K (400–1100 nm) |
| Source Diameter | 40 mm |
| Luminance Adjustment Range | 60 mcd/m² to 6 kcd/m² (base version) |
| Luminance Dynamic Range | ≥10⁵ (base), ≥10⁸ (advanced, optional) |
| Intensity Control | Manual mechanical attenuator via rotary knob |
| Spectral Filtering | Manual insertion of bandpass or narrowband filters (advanced version only) |
| Emission Profile | Lambertian, ±15° half-angle |
| Operating Temperature | +5 °C to +35 °C |
| Storage Temperature | −5 °C to +55 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Dimensions | 280 × 260 × 230 mm |
| Weight | 8 kg |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LT-SHPM |
| Pricing | Available Upon Request |
| Brand | LTB |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ATM |
| Price Range | USD 13,500 – 40,500 (est.) |
| Core Configuration | Pulsed Gas-Pumped Dye Laser System with Optional SHG Module |