| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Pt-Co |
| Measurement Range | 0–500 Pt-Co |
| Resolution | 1 Pt-Co |
| Repeatability | ±3% or ±1 Pt-Co (whichever is greater) |
| Path Length | 50 mm |
| Standard Compliance | ASTM D1209, ISO 6271, APHA Method 2120 B, USP <631> |
| Viewing Field | Dual-field (2-field) comparator display |
| Cuvettes | 3 × plastic 50 mm cuvettes (W100), 1 × glass 50 mm cuvette (W100) |
| Calibration Standards | 60 mL certified Pt-Co reference solution |
| Filter Set | Integrated certified interference filters (traceable to NPL/UKAS) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | Germany |
| Model | EC2000 Visual-Electronic Gardner Colorimeter |
| Measurement Principle | Visual-electronic dual-mode Gardner color assessment using standardized glass filters and reference liquids |
| Display | 4.3-inch capacitive touchscreen |
| Light Path Options | 10 mm, 20 mm, 30 mm, 50 mm (user-selectable) |
| Cuvette Materials | Optical-grade glass or disposable polystyrene |
| Power Supply | AC adapter (100–240 V) + internal rechargeable Li-ion battery (≥8 h operation) |
| Data Storage | ≥20,000 measurement records with timestamp, sample ID, operator ID, and color index |
| Connectivity | USB-A port for data export (CSV/Excel-compatible) |
| Calibration Verification | Dual-method — certified Gardner filter set + NIST-traceable liquid reference standards |
| Compliance | Meets ASTM D156, ASTM D6166, ISO 4630, and IP 15 for Gardner color scale determination |
| Environmental Operating Range | 10–40 °C, 20–80% RH non-condensing |
| Dimensions | 220 × 120 × 95 mm |
| Weight | 1.2 kg (with carrying case) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Visual-Electronic Platinum-Cobalt Colorimeter |
| Measurement Principle | Visual-electronic comparison against Pt-Co (APHA) standard scale |
| Calibration Options | Certified glass filter set + reference liquid standards |
| Light Path Options | 10 mm, 20 mm, 50 mm (user-selectable) |
| Cuvette Materials | Optical-grade glass or disposable polystyrene |
| Display | 4.3-inch capacitive touchscreen with color-coded pass/fail indicators (green/amber/red) |
| Data Storage | >20,000 measurement records with timestamp, sample ID, operator ID, and method tag |
| Connectivity | USB-A port for data export (CSV format) |
| Power Supply | AC adapter (100–240 V) + internal rechargeable Li-ion battery (≥8 h continuous operation) |
| Enclosure | IP54-rated ruggedized housing |
| Compliance | Designed to support ASTM D1209, ISO 6271, ISO 7887, and USP <631> color assessment protocols |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 ASTM |
| Measurement Range | 0–8 ASTM units |
| Resolution | 0.1 unit |
| Repeatability | ±0.1 unit |
| Path Length | 33 mm |
| Standard Compliance | ASTM D1500, ASTM D6045 |
| Field of View | 3-field |
| Cuvette Types | Two 33 mm plastic cuvettes (W100), Two 33 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL reference liquid standards |
| Filter Set | Two certified interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 Saybolt |
| Measurement Range | –16 to +30 Saybolt |
| Resolution | 1 Saybolt Unit |
| Repeatability | ±1 Saybolt Unit |
| Path Length | 50 mm |
| Standard Compliance | ASTM D156, ASTM D6045 |
| Field of View | Triple-field viewing system |
| Cuvettes | Two 50 mm plastic cuvettes (W100), two 50 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL certified reference liquids |
| Filter Set | Two calibrated interference filters |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | EComparator |
| Light Source | White LED |
| Detector | Tristimulus Sensor |
| Display | 3.5-inch 320×240 24-bit resistive touchscreen |
| Interface | USB 2.0 |
| Power | USB or 4× AA batteries |
| Dimensions | 106 mm (W) × 210 mm (D) × 57 mm (H) |
| Housing | Flame-retardant ABS |
| Operating Temperature | Up to 80 °C |
| Data Storage | >20,000 measurements |
| Supported Standards | ASTM D1209, ASTM D1544, ASTM D6166, AOCS Td 1a, MS 817 Part 10, ASTM D156, ASTM D6045, ASTM D1500, ISO 2049, IP 196 |
| Color Scales | Pt-Co (0–500, resolution 1 unit, repeatability ±3% +1 unit, 2° field), Gardner (0–18, resolution 0.1 unit, repeatability ±0.2, 2° field), ASTM Color (0–8, resolution 0.1 unit, repeatability ±0.1, 3° field), Saybolt (–16 to +30, resolution 1 unit, repeatability ±1, 3° field) |
| Languages | English, French, German, Spanish, Italian, Chinese, Japanese, Russian |
| Brand | Lovibond/Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | ET4110 |
| Measurement Unit | Pfund scale (0–160 Pfund) |
| Compliance | USDA Honey Grading Standards (7 Grade Classes), ASTM D1544 (for color reference correlation) |
| Display | Digital LCD with keypad interface |
| Application Mode | Benchtop & Field-Portable Operation |
| Power Supply | AC adapter or battery-powered (4 × AA, optional) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ET76020 |
| Measurement Range | 0.2–2000 NTU (4 auto-ranging segments) |
| Accuracy | ±0.2 NTU (0.2–2 NTU), ±1 NTU (2–20 NTU), ±5 NTU (20–200 NTU), ±50 NTU (200–2000 NTU) |
| Resolution | 0.1 NTU / 0.1 NTU / 1 NTU / 1 NTU per range |
| Light Source | 875 nm halogen infrared LED |
| Detection Geometry | Dual-detector system (90° scatter + reference detector) |
| Compliance | ISO 7027:2016, DIN EN 50081-1 & EN 50082-2 |
| Operating Environment | 0–40 °C, 30–90 % RH non-condensing |
| Power Supply | 9 V alkaline battery |
| Dimensions | 90 × 110 × 55 mm |
| Weight | 400 g |
| Calibration | Four-point user-selectable (1, 10, 100, 1000 NTU) with factory and user-defined standard support |
| Sample Cell | Waterproof 24 mm glass cuvettes with integrated temperature compensation circuitry |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ET760910 |
| Measurement Range | 0.01–1100 NTU (auto-ranging) |
| Accuracy | ±2% or ±0.01 NTU (0–0.05 NTU) |
| Resolution | 0.01 NTU (0.02–9.99 NTU), 0.1 NTU (10.0–99.9 NTU), 1 NTU (100–1100 NTU) |
| Principle | Nephelometric turbidity measurement at 90° detection angle |
| Light Source | Infrared LED (860 nm) |
| Calibration | Four-point calibration (1, 10, 100, 1000 NTU) with factory and user-defined standards |
| Compliance | ISO 7027 |
| Display | Graphical LCD with multilingual interface (English, German, French, Italian, Spanish) |
| Data Storage | 1000 measurements with timestamp, sample ID, and operator code |
| Interface | RS232 (9-pin D-sub), ASCII output |
| Power | Rechargeable NiCd battery pack (7×AA, 750 mAh) |
| Operating Environment | 5–40 °C, 30–90% RH (non-condensing) |
| Dimensions (main unit) | 265 × 195 × 70 mm |
| Weight (incl. batteries & calibration set) | ~1000 g |
| Certifications | CE marked |
| Warranty | 24 months limited warranty (excludes consumables, misuse, unauthorized modification, or field damage beyond normal operational conditions) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ET93810 |
| Measurement Standards | ISO 7027 (IR), US EPA Method 180.1 (WS) |
| Range | 0.01–1000 NTU |
| Resolution | 0.01 NTU (0–9.99), 0.1 NTU (10–99.9), 1 NTU (100–1000) |
| Accuracy | ±2% of reading ±0.01 NTU |
| Calibration | Automatic 3-point recognition (0.02, 10, 100, and 1000 NTU standards) |
| Response Time | 6 seconds |
| Sample Volume | 30 mL (min. 27 mL) |
| Light Source | Infrared LED (ISO mode) or Tungsten lamp (EPA mode) |
| Detector Configuration | 90° primary detector + auxiliary photodiode array for chromatic compensation |
| Data Interface | RS-232 |
| Power Supply | 100–240 VAC / 12 VDC |
| Dimensions | 273 × 254 × 95 mm |
| Weight | 1320 g |
| Environmental Operating Conditions | 0–50 °C, 30–90 % RH |
| Certifications | CE, UL, CSA, ISO 7027 compliant |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ET93811 |
| Measurement Standards | ISO 7027 (IR), EPA Method 180 (optional white light) |
| Range | 0.0001–10000 NTU / FNU / FAU / EBC |
| Resolution | 0.0001 NTU (at lowest range) |
| Accuracy | ±2% ±0.01 NTU (0–1000 NTU), ±5% (1000–4000 NTU), ±10% (4000–10000 NTU) |
| Detection Geometry | 90° detector + auxiliary photodiode array for color compensation |
| Light Source | IR LED (ISO 7027 compliant) or tungsten lamp (EPA 180 mode, optional) |
| Response Time | 6 seconds |
| Sample Volume | 30 mL (min. 27 mL) |
| Calibration | Auto-recognized standards at 0.2, 10, 100, and 1750 NTU |
| Data Interface | RS232 |
| Environmental Operating Conditions | 0–50°C, 30–90% RH |
| Certifications | CE, UL, CSA, ISO 7027 compliant |
| Power Supply | 100–240 VAC / 12 VDC |
| Dimensions | 355 × 304 × 305 mm |
| Weight | 3180 g |
| Brand | Lovibond / Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | ICx |
| Measurement Principle | Benchtop Transmittance Spectrophotometry |
| Standards Compliance | ASTM D1209, ASTM D5386, ISO 6271, ASTM E313 |
| Color Scales | Pt-Co/Hazen/APHA, CIEL*a*b*, Yellowness Index (YI) |
| Repeatability (Instrument) | ±0.5 Pt-Co (0–20), ±2 Pt-Co (>20) |
| Measurement Time | <10 s |
| Light Source | 12 V / 20 W Halogen Lamp (User-Replacable) |
| Sample Chamber | Sealed, Laser-Etched, Chemically Resistant |
| Optical Path Length Range | 0.1–152.4 mm |
| Display | 4.3" Full-Color LCD |
| Data Storage Capacity | >100,000 Measurements |
| Interface | USB, RS232 |
| Power Input | 110–250 V AC, 60 W, External 24 V Adapter |
| Dimensions (W×H×D) | 301 × 152 × 331 mm |
| Net Weight | 5.2 kg |
| Housing Material | Anodized Aluminum with Chemical-Resistant Textured Coating |
| Optical Components | Precision Glass Optics |
| Baseline Calibration | One-Touch Automatic |
| Illuminants & Observer | CIE Standard Illuminants A, C, D65 |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Certifications | CE, RoHS, WEEE |
| Warranty | 2 Years (Excluding Light Source and Consumables) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ICx |
| Instrument Type | Benchtop Spectrophotometric Colorimeter |
| Light Source | Tungsten-Halogen Lamp |
| Compliant Standards | ASTM D1209, ASTM D5386, ISO 6271, ASTM E313 |
| Built-in Color Scales | Pt-Co/APHA/Hazen, CIEL*a*b*, Yellowness Index (YI E313) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | UK |
| Model | LC100 & SV100 |
| Instrument Type | Portable |
| Optical Geometry | 45/0° integrating sphere |
| Light Source | Independent tri-directional 25-LED array (8 visible wavelengths + 1 UV LED) |
| Illuminant/Observer | D65/10° and A/10° |
| Spectral Range | 400–700 nm (visible) + UV channel |
| Repeatability | ≤0.1 ΔE94 (D65/10°, white tile) |
| Aperture Sizes | 4 mm and 8 mm |
| Measurement Time | ≤1.8 s |
| Standard Storage | 20 |
| Sample Storage | 350 |
| Display | 4.5 cm color TFT |
| Data Interface | USB mass storage mode |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 20–80% RH (non-condensing) |
| Altitude Limit | 2000 m |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | Germany |
| Model | LC100 |
| Instrument Type | Handheld (not desktop — corrected per product reality) |
| Optical Geometry | 45°/0° (not d/8° — corrected based on official Lovibond specs) |
| Illuminants | 8 visible + 1 UV (D65, A, C, F2, F7, F11, F12, TL84, UV) |
| Color Spaces | CIELAB (L*a*b*), CIELCH, CIEXYZ, RGB, sRGB, HEX |
| Color Difference Formulas | ΔE*ab, ΔE94, ΔE00, ΔECMC(2:1) |
| Repeatability | ≤0.08 ΔE*ab (for white tile, 10 measurements) |
| Spectral Range | 400–700 nm (31-channel silicon photodiode array) |
| Display | 3.5" color TFT touchscreen |
| Memory Capacity | 30 standards + 350 measurements (with timestamp, name, and optional voice annotation) |
| Output Formats | PDF & CSV reports via USB or Bluetooth |
| Compliance | ISO 11664, CIE No. 15:2018, ASTM D2244, DIN 5033, GLP-ready audit trail (timestamped, user-identifiable entries) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F |
| Light Source | Dual 12 V / 10 W Tungsten-Halogen Lamps |
| Viewing Field | Fully Adjustable Prism System with Integrated Blue Filter for Illumination Standardization |
| Illumination Standard | Approximates CIE Standard Illuminant D65 |
| Color Scale Compatibility | Gardner (1–18), FAC (1–45), EBC (2–27), ASTM D1500 (0.5–8.0), US Naval Stores Rosin (XC-Dx), Lovibond RYBN (Red: 0.1–79.9, Yellow: 0.1–79.9, Blue: 0.1–49.9, Neutral: 0.1–3.9) |
| Resolution | 0.1 Lovibond Unit |
| Cell Pathlength Range | 0.1–153 mm (0.004–6 in) |
| Standard Color Discs | 11 Precision-Calibrated Glass Discs (R×3, Y×3, B×3, N×2) |
| Included Cells | 1 in (25.4 mm) and 5¼ in (133 mm) standard cells |
| Compliance | AOCS Cc 13e-92, AOCS Cc 13j-97, BS 684, ASTM D1500, ISO 4630 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model F |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Color Scale | Lovibond RYBN |
| Red Scale | 0.1–79.9 |
| Yellow Scale | 0.1–79.9 |
| Blue Scale | 0.1–49.9 |
| Neutral Scale | 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Dual 12 V / 10 W Tungsten-Halogen Lamps |
| Illuminant Compliance | CIE Standard Illuminant C |
| Sample Chamber | Removable White Liner with Precision-Registered Cell Notch |
| Power Supply | External Low-Voltage DC Adapter |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Model F |
| Optical Principle | Visual color matching against calibrated glass color standards |
| Illumination | Standardized D65 daylight simulator with controlled viewing geometry |
| Viewing System | Dual-field comparator with fixed 45°/0° optical path |
| Sample Format | Liquid or semi-solid in standard 10 mm or 25 mm pathlength cuvettes |
| Compliance | ASTM D1500, ISO 2049, AOCS Cc 13b-92, IP 15, BS 684-2.17 |
| Brand | Lovibond/Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | Model Fx (PFXeo) |
| Light Source | Tungsten-Halogen Lamp |
| Wavelength Range | 380–780 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | <15 nm |
| Photometric Range | 0–100% Transmittance (T) |
| Photometric Linearity | ±0.01% T |
| Stray Light | <0.01% T |
| Repeatability | ±0.5% T |
| Detector Type | Spectrophotometric |
| Housing Material | Anodized Aluminum |
| Dimensions | 301 mm (W) × 152 mm (H) × 331 mm (D) |
| Weight | 5.16 kg |
| Operating Environment | 5–40 °C, ≤90% RH (non-condensing) |
| Storage Environment | −20–85 °C, ≤90% RH (non-condensing) |
| Power Supply | 190–240 V AC |
| Data Interfaces | USB, RS-232 |
| Certifications | CE |
| Supported Languages | English, Chinese, French, German, Italian, Spanish, Portuguese, Russian, Japanese |
| Compliant Standards | ISO 15305, AOCS Cc 13b-45 / Cc 8d-55 / Cc 13j-97 / Cc 13e / Cc 13j, BS 684 Section 2.20, MS 252 Part 16, IP 17, GB/T 22460-2008, Lovibond® RYBN, Lovibond RY10:1 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model Fx |
| Price Range | USD 6,800 – 13,600 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | MODEL-F |
| Measurement Principle | Dual-field visual comparison against Lovibond® RYBN glass filter standards |
| Color Scale | Lovibond Red (R): 0.1–79.9, Yellow (Y): 0.1–79.9, Blue (B): 0.1–49.9, Neutral (N): 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Twin 12 V / 10 W tungsten-halogen lamps |
| Illumination | Daylight-mimicking (CIE Standard Illuminant C approx.) with integrated blue filter for spectral consistency |
| Optical System | Precision prism-based dual-view field with standardized viewing geometry |
| Sample Path Length | Adjustable from 0.1 to 153 mm (0.004 to 6 in) |
| Power Supply | 220 V AC / 12 V DC adapter |
| Dimensions & Weight | 330 × 410 × 230 mm |
| Certifications | CE compliant |
| Accessories | Interchangeable R/Y/B/N filter discs (e.g., Part Nos. 180200, 180300–180400), RYBN standard filter sets (184000–187000) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Product Type | Nesslerization-Compatible Glass Color Comparator Tubes |
| Model Designations | AF228, DB420, AF262, DB421, AF306, DB423, AF306/P, DB424/13.5 |
| Tube Format | Paired Sets (Matched Optical Path Length) |
| Material | Borosilicate Glass, ASTM E2020-22 Compliant |
| Nominal Path Length | 10 mm, 13.5 mm, 20 mm, 25 mm, 50 mm (Model-Dependent) |
| Calibration Traceability | NIST-Traceable Reference Standards Available |
| Compliance | ISO 7887, ASTM D1209, ASTM D5391, USP <631>, EN ISO 7887-2 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXeo |
| Measurement Principle | Absorption Photometry at Defined Wavelengths |
| Optical System | Single-beam Spectrophotometric Colorimeter |
| Light Source | Tungsten-Halogen Lamp |
| Spectral Range | 380–780 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | <15 nm |
| Photometric Range | 0–100% Transmittance (T) |
| Photometric Linearity | ±0.01% T |
| Stray Light | <0.01% T |
| Repeatability | ±0.5% T |
| Detector Type | Silicon Photodiode Array |
| Sample Temperature Control | Integrated Peltier Heater (Ambient to +60°C) |
| Display | Real-time Sample Temperature & Color Value |
| Sample Cell Options | 25 mm (1") and 133 mm (5.25") pathlength cuvettes, sealed & chemically resistant |
| Housing Material | Recyclable anodized aluminum (100% recyclable) |
| Dimensions | 301 × 152 × 331 mm (W×H×D) |
| Weight | 5.16 kg |
| Operating Environment | 5–40°C, ≤90% RH (non-condensing) |
| Storage | −20–+85°C, ≤90% RH (non-condensing) |
| Power Supply | 190–240 V AC |
| Interfaces | USB 2.0, RS-232 |
| Compliance | CE Marked |
| Supported Standards | Lovibond® RYBN, Lovibond RY10:1, AOCS Cc 13b-45 / Cc 8d-55 / Cc 13j-97 / Cc 13e / Cc 13j, ISO 15305, IP 17, MS 252 Part 16, GB/T 22460-2008 |
| Languages | English, Chinese, French, German, Italian, Spanish, Portuguese, Russian, Japanese |
| Brand | Lovibond (Tintometer Ltd) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 880F |
| Measurement Principle | Tristimulus Filter Photometry |
| Standard Color Scales | Lovibond® RYBN, APHA/Pt-Co, Gardner, Saybolt, ASTM D1209/D5386/D6166, ISO 2764, ISO 4630, USP <631>, CIE L*a*b*, CIE XYZ, ΔE*ab |
| Display | High-contrast 7-inch TFT color touchscreen |
| Data Output | USB 2.0, Ethernet (LAN), RS232 |
| Compliance | CE, UKCA, RoHS, FDA 21 CFR Part 11 ready (audit trail & electronic signature support via optional software license) |
| Calibration | Factory-certified with RCMSi initial verification kit |
| Sample Cell Compatibility | 10 mm, 25 mm, 33 mm, 50 mm pathlength cells (1" and 5.25" round cells included) |
| Light Source | Tungsten-halogen lamp (3000 K CCT, stable spectral output per IEC 61000-4-11) |
| Repeatability | ≤ ±0.1 Lovibond unit (RYBN), ≤ ±0.3 APHA units (typical, under controlled lab conditions) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950 |
| Compliance | ASTM D1209, ASTM D1500, ASTM D6045, AOCS Cd 13b-97, ISO 2761, ISO 4630, ISO 6271, Gardner ASTM D1544, Saybolt ASTM D156 |
| Measurement Principles | Transmission colorimetry using tungsten-halogen light source and precision interference filters |
| Display | High-resolution LCD with multilingual interface (including English & Chinese) |
| Sample Path Length Options | 10 mm, 20 mm, 33.3 mm, 50 mm, 100 mm |
| Output Data | CIE L*a*b*, CIE XYZ, CIE Yellowness Index (YI), Whiteness Index (WI), spectral reflectance/transmittance (380–720 nm, 10 nm intervals), and proprietary color scales |
| Connectivity | RS-232, USB, optional Ethernet |
| Software Compatibility | ColorSoft™ PC software for data export, audit trail, and report generation |
| Regulatory Support | FDA 21 CFR Part 11 compliant configuration available (with user authentication, electronic signatures, and full audit trail) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi-195 |
| Optical Configuration | 9-band interference filter photometer |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | Δx,y ≤ ±0.0004 |
| Measurement Time | <30 s |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–50 mm |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Power Supply | 90–240 VAC (external adapter) |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Calibration | One-touch automated baseline calibration |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions (W×D×H) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA, Gardner, Iodine, Saybolt, ASTM Color, FAC, EBC, ASBC, ICUMSA, Pfund, ADMI, EP, USP, CIE L*C*h, Hunter Lab, spectral reflectance/data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PFXi195 Series |
| Price Range | USD 6,800 – 13,600 (FOB UK) |
| Light Source | Tungsten Halogen Lamp |
| Cell Material | Stainless Steel Cuvette Holder |
| Calibration | RCMSi-certified Verification Kit Included |
| Software | Windows-based Lovibond® ColorSoft v5.x |
| Compliance | ASTM D1209, D1500, D5386 |
| Data Interface | USB 2.0 |
| Display | Backlit LCD with On-Screen Guidance |
| User Access Control | Password-protected Admin Mode |
| Maintenance | Tool-free Cuvette Tray Removal & Lamp Replacement |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/1 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA (ASTM D1209), Gardner (ASTM D1544/D6166), Iodine (DIN 6162), CIE XYZ/Lab, Spectral Reflectance Data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/1 |
| Measurement Standards | Pt-Co/Hazen/APHA, Gardner, Iodine, CIE L*a*b*, CIE XYZ, Spectral Reflectance (360–780 nm) |
| Display | 7-inch TFT LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Compliance | ISO 9001, ISO/IEC 17025, ASTM D1209, ASTM D1500, ASTM D5386, ISO 6271, ISO 4630 |
| Data Management | GLP-compliant audit trail (date/time, operator ID, sample ID), internal storage for ≥10,000 results |
| Sample Handling | Removable stainless-steel cuvette holder, compatible with 10–50 mm pathlength glass or quartz cuvettes, optional flow-through cell |
| Enclosure | Powder-coated stainless-steel chassis with chemical-resistant surface finish |
| Software | Included ColorSoft™ PC software for spectral visualization, CIE chromaticity diagram plotting, deviation analysis (ΔE*ab, ΔL*, Δa*, Δb*), and custom standard creation |
| Remote Maintenance | RCMSi™ Remote Calibration & Monitoring System enabled |