Optical Instruments
Filter
Showing 4411–4440 of 7843 results
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420 |
| Temperature Range | −196 °C to 420 °C (liquid nitrogen cooling optional) |
| Temperature Stability | < 0.1 °C |
| Max Ramp Rate | 0.1–50 °C/min |
| Sample Area | 53.5 × 43 mm |
| XY Translation | 15 × 15 mm |
| Optical Aperture | 2.5 mm |
| Minimum Objective Working Distance | 6 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Dimensions (Stage Only) | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTS420 |
| Temperature Range | −196 °C to +420 °C (liquid nitrogen required for sub-ambient operation) |
| Stage Dimensions | 160 × 80 × 24 mm |
| Sample Area | 53.5 × 43 mm |
| X–Y Translation Range | 15 × 15 mm |
| Standard Slide Holder | 76 × 26 mm |
| Optical Aperture | 2.5 mm diameter |
| Temperature Stability | < ±0.1 °C at isothermal conditions |
| Heating/Cooling Rate | 0.1–50 °C/min (controller-dependent) |
| Sensor | 100 Ω Platinum RTD |
| Environmental Control | Sealed chamber with gas inlet/outlet valves (inert atmosphere or humidity control) |
| Optical Configuration | Compatible with transmitted and reflected light microscopy |
| Electrode Integration | Optional internal electrodes for electric field application or signal measurement (LCD cell-ready configuration) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | LTSE420 |
| Temperature Range | Ambient to +420 °C (with optional cryo-cooling: down to −196 °C) |
| Temperature Stability | <0.01 °C |
| Temperature Resolution | 0.01 °C |
| Electrode Configuration | Standard dual-electrode |
| Optical Aperture | Ø2.4 mm |
| Sample XY Translation | 15 × 15 mm |
| Stage Surface Area | 53.5 × 43 mm |
| Compatible Sample Holders | Standard 76 × 26 mm microscope slides or Ø16 mm coverslips |
| Heating Rate | 0.1–50 °C/min |
| Minimum Objective Working Distance | 6.0 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Stage Dimensions | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MDSG600 |
| Temperature Range | −196 °C to +600 °C |
| Heating/Cooling Rate Control | 0.01–150 °C/min |
| Position Resolution | 0.05 µm |
| Position Repeatability | <3 µm |
| XY Travel Range | 15 mm × 15 mm |
| Stored Coordinates | 150 (X,Y) |
| Aperture Diameter | 1.3 mm |
| Objective Working Distance Compatibility | 0.1–4.9 mm |
| Condenser Minimum Working Distance | 12.7 mm |
| Sample Holders | 7 mm, 10 mm, or 16 mm diameter |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | MFS350 |
| Temperature Range | −195 °C to 350 °C |
| Sample Width | 0.001–22 mm |
| Sample Thickness | 0.001–2 mm |
| Minimum Sample Length | 26 mm |
| Tensile Speed | 1–5000 µm/s |
| Force Range | 0.01–20 N or 0.1–200 N |
| Force Resolution | 0.01 N or 0.1 N |
| Maximum Travel | 85 mm |
| Position Resolution | 1 µm |
| Objective Working Distance | 7.5 mm |
| Condenser Working Distance | 12.5 mm |
| Temperature Ramp Rate | 0.1–60 °C/min |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | PE100 |
| Temperature Range | −5 °C to 99 °C |
| Ramp Rate | ±10 °C/min |
| Temperature Accuracy & Stability | ±0.1 °C (full range) |
| Viewing Aperture Diameter | 16 mm |
| Sample Area Diameter | 108 mm |
| Minimum Objective Working Distance | 0.1 mm |
| Heating Element | Pt100-resistive |
| Control Interface | Integrated LCD touchscreen |
| Power Supply | DC |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | PE120 |
| Temperature Range | −25 °C to +120 °C |
| Heating/Cooling Rate | 0.1–20 °C/min |
| Stage Aperture Diameter | 5 mm |
| Sample Area | 35 × 32 mm |
| Temperature Stability & Accuracy | ±0.1 °C |
| Sensor | Pt100 Platinum Resistance Thermometer |
| Control Interface | LCD Touchscreen |
| Minimum Objective Working Distance | 0.1 mm |
| Minimum Condenser Working Distance | 5 mm |
| Stage Dimensions (PE120XY) | 160 × 110 mm |
| Cooling Method | External Recirculating Chiller (ECP Series) |
| Compatibility | Olympus BX, Nikon Ni-E/Ni-U, Zeiss Axio Imager/Axioskop with Optional Mount Adapters |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | RH95 |
| Compatible Stages | THMSG600, MFS, LTS420, HFS600 |
| Max Controlled Volume | 2000 cm³ |
| RH Range | 5–90% RH |
| RH Stability | ±0.5% RH at setpoint |
| RH Ramp Rate | ~7% RH/min |
| Sensor Response Time | ~8 s |
| Sensor Type | Integrated Digital Capacitive T/RH Sensor |
| Inert Gas Input | Up to 5 bar (optional regulator module) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS600 |
| Temperature Range | Ambient to +600 °C |
| Maximum Heating Rate | 150 °C/min |
| Temperature Stability & Accuracy | ±0.1 °C |
| X–Y Translation Range | 16 mm each axis |
| Sample Area Diameter | 22 mm |
| Optical Aperture Diameter | 2.0 mm |
| Top Window Thickness | 0.17 mm (standard coverslip) |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Stage Dimensions | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMS600 |
| Temperature Range | –196 °C to +600 °C |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Temperature Stability | <0.01 °C |
| Temperature Accuracy | ±0.1 °C (full range) |
| Sample Area Diameter | 22 mm |
| Optical Aperture Diameter | 2.0 mm |
| X/Y Translation Range | 16 mm each axis |
| Upper Window Thickness | 0.17 mm (coverslip-grade fused silica) |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Dimensions (Stage Body) | 160 × 80 × 24 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSE600 |
| Temperature Range | −196 °C to +600 °C (−196 °C requires optional liquid nitrogen cooling system) |
| Temperature Stability | < 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–150 °C/min |
| Optical Aperture Diameter | 2.4 mm |
| Sample XY Translation Range | 15 × 15 mm |
| Sample Area | 22 mm diameter |
| Electrode Configuration | Standard dual-electrode |
| Electrode Integration | Embedded in sealed chamber, compatible with conductive glass LC cells |
| Chamber Environment Control | Vacuum, inert gas (N₂, Ar), or humidity-controlled atmosphere |
| Window Thickness | 0.17 mm |
| Minimum Objective Working Distance | 4.5 mm |
| Minimum Condenser Working Distance | 13.2 mm |
| Stage Dimensions | 137 × 92 × 22 mm |
| Compatible Sample Format | 16 mm diameter cover slips with capillary-filled LC cells (5 µm cell gap) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSG600 |
| Temperature Range | −196 °C to +600 °C |
| Temperature Stability | < 0.01 °C |
| Temperature Resolution | 0.01 °C |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample X/Y Translation Range | 16 mm |
| Heating Zone Diameter | 22 mm |
| Window Thickness (Cover Slip) | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | THMSG600 |
| Temperature Range | −195 °C to +600 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Stability | <0.01 °C |
| Heating/Cooling Rate | 0.01–150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample XY Travel | 16 mm |
| Heating Area Diameter | 22 mm |
| Window Thickness | 0.17 mm |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Dimensions | 137 × 92 × 22 mm |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1200 |
| Temperature Range | Ambient to 1200 °C |
| Temperature Accuracy & Stability | ±1 °C |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | Ø10 × 5 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Key | Brand: Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1400XY |
| Temperature Range | Ambient to 1400 °C |
| Heating Rate | 1–200 °C/min |
| Temperature Stability | ±1 °C |
| XY Translation Range | X = 4 mm, Y = 10 mm |
| Thermocouple Type | S-type (Pt-10% Rh / Pt) |
| Maximum Sample Size | 5 × 5 × 0.5 mm |
| Minimum Objective Working Distance | 6 mm |
| Minimum Condenser Working Distance | 12.5 mm |
| Optical Aperture | 1.7 mm |
| Gas-Tight Chamber | Yes |
| Cooling | Dedicated Water-Circulation System |
| Dynamic Thermal Response | Fast heating and cooling with real-time control |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1500 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy & Stability | ±1 °C over full range |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | φ7 × 6 mm or φ7 × 3 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Vacuum Compatibility | Down to 10⁻³ mbar |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | TS1500 |
| Temperature Range | Ambient to 1500 °C |
| Temperature Accuracy & Stability | ±1 °C over full range |
| Optical Aperture Diameter | 1.7 mm |
| Sample Chamber Dimensions | φ7 × 6 mm or φ7 × 3 mm |
| Maximum Heating Rate | 200 °C/min |
| Minimum Objective/Condenser Working Distance | 6.0 mm / 14.8 mm |
| Vacuum Compatibility | Down to 10⁻³ mbar |
| Brand | Linos |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Designation | Linos F-θ Lens / Beam Expander |
| Pricing | Upon Request |
| Brand | Linos |
|---|---|
| Origin | Germany |
| Model | newopto |
| Wavelength Range | 355–1064 nm |
| Expansion Ratio | 2×–8× (variable, manual or motorized) |
| Max. Input Beam Diameter (1/e² Gaussian) | 3.4–8 mm |
| Max. Output Beam Diameter | 31 mm |
| Number of Lens Elements | 4 |
| Entrance Lens Material | Fused Silica (Quartz) |
| Mounting Diameter | 37.6 mm |
| Compliance | ISO 10110 optical surface specifications, RoHS-compliant housing |
| Brand | Linos |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OS4500 |
| Pricing | Contact for Quotation |
| Brand | LINOS |
|---|---|
| Origin | Germany |
| Product Category | Optical Component |
| Crystal Types | KD*P, BBO, RTP, LiNbO₃ |
| Aperture Diameter | Ø2.6–Ø15 mm |
| Transmission | 84–99% |
| Extinction Ratio (Zero Voltage) | 100:1–3000:1 |
| Half-Wave Voltage (at 1064 nm) | 1.8–8 kV |
| Capacitance | 3.6–6.0 pF |
| Damage Threshold | >100–600 MW/cm² (1064 nm, 10 ns, 1 Hz) |
| Wavefront Distortion | <λ/4 |
| Mounting Compatibility | Up to 35 mm cell diameter |
| Operating Modes | Standard, Water-Immersion (IM), Sol-Gel (SG) |
| Brand | LIOP-TEC GmbH |
|---|---|
| Origin | Germany |
| Model Series | STAR, STARi, PiezoStar, ANTARES, Planet |
| Mounting Types | Manual Kinematic, 5-Axis, Goniometric, Vacuum-Compatible, Non-Magnetic |
| Max. Aperture | 22 in (559 mm) |
| Adjustability | 170 TPI (0.15 mm pitch), Angular Resolution down to 0.5 µrad |
| Linear Resolution (PiezoStar) | 20 nm |
| Holding Force (PiezoStar) | >100 N |
| Thermal Stability | Designed for long-term beam path retention (ΔT ≤ ±0.5 °C drift tolerance) |
| Compliance | ISO 9001-certified manufacturing |
| Key | Brand: Litilit |
|---|---|
| Model | Biolit-2 |
| Center Wavelength | 1050 ± 5 nm |
| Average Power | > 2 W |
| Pulse Duration | < 70 fs (typ. 55 fs) |
| Pulse Duration Stability | ±3 fs |
| Strehl Ratio | > 0.9 |
| Pre-chirp Tuning Range | −8000 to +500 fs² |
| Repetition Rate | 15/20/30/40 MHz (factory-set) |
| Analog Power Control | 1–100% |
| Beam Quality M² | < 1.2 (typ. 1.05) |
| Beam Roundness | > 0.9 (typ. 0.94) |
| Beam Diameter (1/e²) | 1.5 ± 0.3 mm |
| Beam Divergence (full angle) | < 1.5 mrad |
| Beam Pointing Stability (RMS) | < 20 μrad |
| Beam Pointing vs. Temperature | < 15 μrad/°C |
| Pulse Energy Stability (RMS) | < 1% |
| Power Stability (RMS) | < 1% |
| Warm-up Time | < 10 min |
| Cooling | Passive air-cooling (laser head) |
| Dimensions (L×W×H) | Laser Head: 313 × 152 × 107 mm³ |
| Control Unit | 449 × 370 × 140 mm³ |
| Cable Length | 3 ± 0.1 m |
| Input Voltage | 24 V DC (with integrated 100–240 V AC, 47–63 Hz power supply) |
| Operating Temp. | 18–30 °C |
| Storage/Transport Temp. | −20 to +70 °C |
| Harmonic Option | 0.4 W @ 525 nm (Biolit-2 SH variant) |
| Interfaces | USB, CAN |
| Patents | US10038297, JP6276471, EP3178137, CN106575849 |
| Brand | Litilit |
|---|---|
| Origin | Lithuania |
| Model | Indylit 10 |
| Output Wavelength | 1030 ± 2 nm (fundamental), 515 ± 1 nm (SHG) |
| Spectral Bandwidth (FWHM) | < 4 nm (1030 nm), < 3 nm (515 nm) |
| Average Power | > 10 W @ 100 kHz / > 12 W @ 1 MHz (1030 nm) |
| Pulse Energy | > 100 µJ (1030 nm), > 50 µJ (515 nm) |
| Pulse Duration | < 400 fs (adjustable from 400 fs to 4 ps) |
| Repetition Rate | 100 kHz – 1.6 MHz (burst mode down to 30 kHz) |
| Beam Quality (M²) | < 1.2 |
| Beam Roundness | > 0.90 (1030 nm), > 0.85 (515 nm) |
| Beam Diameter (1/e²) | 2.6 ± 0.2 mm (1030 nm), 2.2 ± 0.2 mm (515 nm) |
| Polarization | Linear, > 200:1 extinction ratio |
| Pre-pulse Contrast | > 1:1000 |
| Post-pulse Contrast | > 1:100 |
| Beam Divergence (full angle) | < 1 mrad |
| Beam Pointing Stability (RMS) | < 20 µrad |
| Power Stability (RMS, 1 s) | < 1% (1030 nm), < 2% (515 nm) |
| Pulse Energy Stability (RMS, 10 s) | < 1% (1030 nm), < 2% (515 nm) |
| Warm-up Time (cold start) | < 30 min |
| Warm-up Time (hot start) | < 3 min |
| Cooling | Passive air-cooled laser head, active fan-cooled control unit |
| Dimensions (L×W×H) | Laser Head: 498 × 248 × 194 mm³ |
| Control Unit | 490 × 370 × 140 mm³ |
| AC/DC Converter | 250 × 125 × 60 mm³ |
| Input Voltage | 100–240 V AC, 47–63 Hz → 24 V DC (25 A) |
| Max Power Consumption | 700 W |
| Avg. Power Draw (steady state) | 300 W |
| Operating Temperature | 18–30 °C |
| Storage/Transport Temp | −20 to +70 °C |
| Interfaces | CAN, USB |
| Pulse Picking | Integrated TTL-gated pulse selector (1–12 pulses/burst) |
| Switching time between outputs | < 1 s |
| Brand | Litilit |
|---|---|
| Origin | Lithuania |
| Model | Indylit 20 |
| Output Wavelength | 1030 ± 2 nm (fundamental), 515 ± 1 nm (SHG) |
| Avg. Power | >13 W @ 100 kHz / >18 W @ 1 MHz (fundamental) |
| Pulse Energy | >130 µJ (fundamental), >70 µJ (SHG) |
| Pulse Duration | <400 fs (adjustable 400 fs – 2 ps) |
| Repetition Rate | 100 kHz – 1 MHz (burst mode down to 30 kHz) |
| Beam Quality | M² < 1.2 |
| Polarization Extinction Ratio | >200:1 |
| Power Stability (RMS) | <1% (fundamental), <2% (SHG) |
| Beam Pointing Stability (RMS) | <20 µrad |
| Cooling | Passive air-cooled laser head, active fan-cooled control unit |
| Dimensions (L×W×H) | Laser Head 498 × 248 × 194 mm³ |
| Input Voltage | 100–240 V AC, 47–63 Hz → 24 V DC |
| Max. Power Consumption | 700 W |
| Operating Temperature | 18–32 °C |
| Compliance | CE, RoHS, IEC 60825-1:2014 Class 4 Laser Product |
| Brand | Litilit |
|---|---|
| Model | Neolit |
| Type | All-Fiber Mode-Locked Femtosecond Seed Source |
| Wavelength Range | 1020–1070 nm (Neolit), 1040 nm (Neolit AMP & BB) |
| Pulse Duration (as-is) | 1–5 ps (Neolit), 5–10 ps (Neolit AMP), 7 ps (Neolit BB) |
| Spectral Bandwidth (FWHM) | 4–12 nm (Neolit), 8–12 nm (Neolit AMP), 20–70 nm (Neolit BB) |
| Average Power | 1–5 mW (Neolit), 20–50 mW (Neolit AMP/BB) |
| Repetition Rate | 15–40 MHz (factory-fixed) |
| Polarization | Linear, PER > 100:1 |
| Output Connector | FC/APC |
| RF Sync Output | SMA |
| Control Interfaces | USB, CAN |
| Power Supply | 12 ± 2 V, max. 3 A |
| Operating Temperature | 15–45 °C |
| Dimensions (L×W×H) | 194 × 135 × 40 mm³ |
| Laser Class | 3B |
| Patented Technology | US10038297, JP6276471, EP3178137, CN106575849 |
| Brand | Laser-Laboratorium Göttingen e.V. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LLG-EUV/XUV-S |
| Price | Upon Request |
| Wavelength Range | <1 nm to 60 nm (with quantum converter) |
| Field of View | 9.0 mm × 6.7 mm (customizable larger FOV available) |
| Dynamic Range | 14-bit |
| Hartmann Plate Pinhole Diameter | 75 µm |
| Pinhole Pitch | 250 µm |
| Tilt Adjustment Range | ±10° |
| X/Y Translation Range | ±10 mm |
| Vacuum Compatibility | UHV-compatible, mounted on CF63 flange |
| Single-Pulse Wavefront Repeatability | λ/116 rms (at λ = 13.5 nm) |
| Brand | Laser-Laboratorium Göttingen e.V. |
|---|---|
| Origin | Germany |
| Model | LLG-fiber |
| Cooling | Water-cooled |
| Core Technology | Noble-gas-filled hollow-core fiber with controlled self-phase modulation (SPM) |
| Length Options | Up to 3 m (customizable) |
| Input Pulse Compatibility | Sub-100-fs, mJ-level ultrafast pulses (e.g., Ti:sapphire, Yb-based amplifiers) |
| Spectral Broadening Factor | >20× at ~60% transmission |
| Output Stability | CEP-stable down to 4 fs |
| Compliance | Designed for integration into ISO 10110-compliant optical beamlines and GLP-aligned ultrafast labs |
| Brand | Laser-Laboratorium Göttingen e.V. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LLG-Ultimate UV |
| Core Components | Liquid Dye-Based Ultrafast Laser System |
| Wavelength | 248.5 nm |
| Pulse Duration | <1 ps |
| Pulse Energy | ≥100 mJ (at optimal gas fill & optics condition) |
| Repetition Rate | 0–10 Hz |
| Timing Jitter | ±3 ns (relative to trigger) |
| Beam Dimensions | ~35 mm × 25 mm (near-field) |
| Near-Field Uniformity | <10% (over 90% beam area) |
| Beam Divergence | <3× diffraction limit |
| Trigger Output | >10 V @ 50 Ω, jitter <30 ps, fixed ~30 ns lead time relative to laser pulse |
| Brand | Laser-Laboratorium Göttingen e.V. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UV-LFM |
| Pricing | Upon Request |