Optical Measurement Instruments
Filter
Showing 3661–3690 of 3889 results
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 430T / Turb 430IR |
| Type | Portable |
| Measurement Range | 0–1100 NTU with automatic range switching |
| Resolution | 0.01 NTU (0.00–9.99 NTU) / 0.1 NTU (10.0–99.9 NTU) / 1 NTU (100–1100 NTU) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±0.01 NTU or ±2% of reading |
| Repeatability | <±0.5% of reading or 0.01 NTU |
| Light Source | Turb 430IR — IR-LED at 860 nm |
| Response Time | 3 s (IR) / 7 s (tungsten) |
| Calibration | Automatic 1–3 point calibration |
| Data Storage | 1000 measurement records + calibration protocols |
| Real-Time Clock | Yes |
| Interface | RS232 and USB (with adapter) |
| Power Supply | 4 × AA alkaline batteries (≈2000 measurements with tungsten lamp |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 430T |
| Product Type | Portable |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 NTU (0.00–9.99 NTU) |
| Operating Temperature | 0 °C to 50 °C |
| Accuracy | ±2% or ±0.01 FNU/NTU (whichever is greater) for 0–500 NTU |
| Measurement Principle | 90° Nephelometric Scattering (EPA Method 180.1 compliant) |
| Light Source | Tungsten Halogen Lamp |
| Response Time | ≤7 s |
| Sample Cell | 28 × 60 mm cylindrical cuvette (20 mL volume) |
| Data Storage | 1000 measurements with timestamp |
| Interface | RS232 standard, USB optional |
| Ingress Protection | IP67 |
| Certifications | CE, cETLus |
| Calibration | Automatic 1–3 point calibration with AMCO-EPA traceable standards (0.02 / 10 / 1000 NTU) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 550T / Turb 550IR |
| Measurement Principle | 90° Nephelometric Scattering |
| Light Source | Tungsten Lamp (Turb 550T) / Infrared LED (860 nm, Turb 550IR) |
| Range | 0.01–1000 NTU / FNU |
| Resolution | 0.01 NTU (0.01–9.99), 0.1 NTU (10.0–99.9), 1 NTU (100–1000) |
| Accuracy | ±2% of reading or ±0.01 NTU |
| Repeatability | <1% of reading or ±0.01 NTU |
| Response Time | <3 s |
| Calibration | Automatic 1–3-point with AMCO® standards (0.02 / 10.0 / 1000 NTU) |
| Sample Temperature Range | +10 to +40 °C |
| Data Interface | RS-232 |
| Power Supply | 100–240 VAC, 47–63 Hz (adapter output: 15 VDC / 1 A) |
| Dimensions | 290 × 252 × 100 mm |
| Weight | 1.0 kg |
| Compliance | Turb 550IR — DIN 27027 / ISO 7027 |
| GLP Functionality | Yes |
| Optional Flow Cell | Available |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | 750 |
| Instrument Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10–99.99), 1 FNU/NTU (100–1100) |
| Operating Temperature | +5 to +55 °C (41–131 °F) |
| Accuracy | ±0.01 FNU/NTU or ±2% of reading (±3% at 500–1100 NTU for Turb 750T) |
| Compliance Standards | DIN EN ISO 7027-1 (Turb 750IR), US EPA Method 180.1 (Turb 750T) |
| Data Storage | 2500 datasets with calibration protocols and AQA flags |
| Interface | USB, RS-232, printer port |
| GLP-Compliant Software | Turb Data PC software (CSV export, LIMS import, user authentication, audit trail) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | 600120 |
| Instrument Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10–99.99), 1 FNU/NTU (100–1100) |
| Operating Temperature | +5 to +55 °C (41–131 °F) |
| Accuracy | ±0.01 FNU/NTU or ±2% of reading (±3% at 500–1100 FNU/NTU) |
| Compliance Standard | DIN EN ISO 7027-1 |
| Light Source | Infrared LED |
| Detection Angle | 90° Nephelometric Scattering |
| Display | Backlit Graphic LCD (160 × 104 pixels) |
| Data Storage | 2500 datasets with calibration protocols and AQA flags |
| Interface | USB, RS-232, optional printer |
| GLP Support | Full audit trail, user ID, sample ID, calibration interval tracking, electronic signatures via Turb Data software |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 750IR |
| Product Type | Portable |
| Measurement Range | 0–1100 FNU |
| Resolution | 0.00–9.99 FNU/NTU: 0.01 FNU/NTU |
| 10–99.99 FNU/NTU | 0.1 FNU/NTU |
| 100–1100 FNU/NTU | 1 FNU/NTU |
| Operating Temperature | +5 to +55 °C (41 to 131 °F) |
| Accuracy | ±0.01 FNU/NTU or ±2% of reading |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb 750T |
| Type | Portable |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.00–9.99 FNU/NTU: 0.01 FNU/NTU |
| 10–99.99 FNU/NTU | 0.1 FNU/NTU |
| 100–1100 FNU/NTU | 1 FNU/NTU |
| Operating Temperature | +5 to +55 °C (41 to 131 °F) |
| Accuracy | ±0.01 FNU/NTU or ±2% of reading |
| Compliance | US EPA Method 180.1 |
| Light Source | Tungsten halogen lamp |
| Detection Principle | Nephelometric measurement at 90° |
| Display | Backlit graphic LCD (160 × 104 pixels) |
| Data Storage | 2500 datasets with calibration protocol, AQA flag, and sample ID |
| Interface | RS232, USB, printer port |
| Software | Turb Data PC software (GLP-compliant, CSV export, LIMS import) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Turb PLUS 2000 |
| Type | Online Turbidimeter |
| Measurement Range | Factory-set: 0–100 NTU |
| Optional ranges | 0–10 NTU and 0–1000 NTU (loaded via USB) |
| Resolution | Down to 0.0001 NTU |
| Operating Temperature | 1 °C to 50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (whichever is greater) for values <40 NTU (0–100 and 0–1000 NTU ranges) |
| Compliance | ISO 7027, EPA Method 180.1 |
| Output Interfaces | 4–20 mA analog output, RS-485 (Modbus RTU), IQ Sensor Net (MIQ/IC2 compatible) |
| Cleaning System | Integrated ultrasonic cleaning |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | VisoTurb 700IQ (Order No. 600010) |
| Type | Portable |
| Measurement Range | 0–4000 FNU |
| Light Source | 860 nm LED |
| Compliance | EN ISO 7027, DIN 38402-51, DIN ISO 5725 |
| Accuracy | <1% (up to 2000 FNU) |
| Resolution | 0.001–1 FNU (auto-ranging) |
| Cleaning System | Integrated ultrasonic transducer |
| Self-Diagnostic | SensCheck™ real-time optical surface and cleaning system monitoring |
| Optical Window | Sapphire |
| Housing Material | V4A stainless steel (1.4571) |
| IP Rating | IP68 |
| Max Pressure | 10 bar |
| Min. Immersion Depth | 7 cm |
| Operating Temp. | 0–60 °C (ultrasonic cleaning active 0–40 °C) |
| Power Consumption | 1.5 W |
| Dimensions | 365 × 40 mm (L × Ø) |
| Weight | ~990 g |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | VisoTurb 900-P |
| Type | Portable |
| Measurement Range | 0–4000 FNU |
| Wavelength | 860 nm ±15 nm |
| Detection Angle | 90° (Nephelometric) |
| Resolution | 0.1 FNU |
| Accuracy | ±0.3 FNU or ±2% (0–999 FNU) |
| Operating Temperature | –5 to 50 °C |
| Storage Temperature | –20 to 80 °C |
| Pressure Rating | Up to 10 bar |
| Material | Titanium shaft, IP68-rated housing |
| Interface | Digital IDS (Intelligent Digital Sensor) protocol |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Type | Benchtop Laboratory Instrument |
| Measurement Range | 1–80 NTU |
| Operating Temperature Range | −15 °C to +150 °C |
| Sample Volume | As low as 2 µL |
| Integrated Software | DYNAMICS Touch™ and DynaPro® NanoStar® |
| Brand | X-Rite |
|---|---|
| Origin | Japan |
| Model | 361T (V) |
| Optical Response | ISO Visual (Photopic) |
| Measurement Range | 0–6.0 D (OD) |
| Accuracy | ±0.01 D (0–5.0 D), ±2% (5.0–5.5 D), ±3% (5.5–6.0 D) |
| Zero Stability | ±0.02 D / 8 h |
| Aperture Sizes | Φ1 mm, Φ2 mm, Φ3 mm |
| Warm-up Time | 2 min (visible), 5 min (UV) |
| Power Supply | 90–130 V AC, ≤80 W |
| Operating Temperature | 10–35 °C, non-condensing |
| Dimensions | H152 × W330 × D435 mm |
| Weight | 8.63 kg |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | 962 |
| Spectral Range | 400–700 nm |
| Reflectance Range | 0–200% |
| Repeatability (ΔE*ab) | ≤0.10 |
| Inter-instrument Agreement (ΔE*ab) | ≤0.20 |
| Measurement Time | ~2 s |
| Aperture Options | 15 mm, 7 mm, 4 mm |
| Dimensions | 109 × 84 × 196 mm |
| Weight | 1100 g |
| Illuminant | Pulsed Tungsten Halogen Lamp |
| Power Supply | 90–130 VAC / 100–240 VAC, 50–60 Hz |
| Storage Capacity | Up to 1,024 Pass/Fail Tolerance Sets |
| Display | Large Graphical LCD |
| Battery | Rechargeable for Field Operation |
| Geometry | 0°/45° (Fixed Illumination/Viewing Angle) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Capsure |
| Weight | 170 g (including battery) |
| Display | 1.75-inch full-color LCD |
| Memory Capacity | Up to 100 color measurements |
| Connectivity | Sync with PANTONE libraries and design software (Adobe Photoshop, Adobe Illustrator, QuarkXPress) |
| Power | Rechargeable lithium-ion battery |
| Timestamping | Date and time stamp for each measurement |
| Compliance | Designed for PANTONE®-aligned color workflows |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Capsure |
| Type | Portable Color Difference Meter |
| Optical Geometry | 0°/45° Integrating Sphere |
| Weight | 170 g (with battery) |
| Display | 1.75-inch full-color LCD |
| Memory Capacity | Up to 100 color measurements |
| Connectivity | PANTONE® library synchronization |
| Software Compatibility | Adobe Photoshop®, Adobe Illustrator®, QuarkXPress® |
| Power Source | Rechargeable lithium-ion battery |
| Timestamping | Date and time stamp for each measurement |
| Color Harmony Guidance | On-device color relationship visualization |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci4100 |
| Geometry | d/8° integrating sphere |
| Repeatability (white tile) | ≤ 0.10 ΔE*ab |
| Inter-instrument agreement (avg.) | ≤ 0.30 ΔE*ab |
| Spot size | 14 mm |
| Measurement aperture | 8 mm |
| Spectral range | 400–700 nm |
| Spectral interval | 10 nm |
| Detector | blue-enhanced silicon photodiode |
| Illuminant | tungsten-halogen lamp (≈500,000 measurements lifespan) |
| Measurement time | ≈2 s |
| Reflectance range | 0–200% |
| Reflectance resolution | 0.01% |
| Gloss measurement | 60° geometry (ASTM D523 compliant) |
| Operating temperature | 10–40 °C |
| Relative humidity | 5–85% RH (non-condensing) |
| Dimensions (W×D×H) | 19.0 × 26.4 × 22.0 cm |
| Weight | 5.2 kg |
| Power | 100–240 VAC, 50/60 Hz or 12 VDC @ 2.5 A |
| Interface | USB 2.0 |
| Included accessories | White calibration tile, black trap, AC adapter, USB cable, operation manual (CD), sample holder |
| Warranty | 12 months |
| Software compatibility | XDS4 SDK, ColorDesigner PLUS |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ci60 |
| Pricing | Available Upon Request |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Instrument Type | Portable |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Tungsten Halogen Lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE* ≤ 0.10 |
| Aperture Options | 4 mm, 8 mm |
| On-device Storage | Up to 4,000 samples |
| Compatibility | Backward-compatible with SP-series instruments |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ci62 |
| Pricing | Upon Request |
| Aperture | 4 mm measurement / 6.5 mm target window or 8 mm measurement / 14 mm target window |
| Light Source | Tungsten-halogen lamp |
| Inter-instrument Agreement | Avg. ΔE*ab ≤ 0.20 (CIE L*a*b*, 12 BCRA Series II tiles, SCI mode), Max. ΔE*ab ≤ 0.40 (any flat tile, SCI mode) |
| Short-term Repeatability | ΔE*ab ≤ 0.05 (white tile) |
| Data Interface | USB 2.0, Bluetooth v4.0 |
| Standard Accessories | Black trap, white & green calibration tiles, user manual, AC adapter, NetProfiler software, sample holder, bench stand, spare battery, dual-bay charger |
| Measurement Modes | QA, Comparison, Opacity, Strength, Job-based workflow |
| Cross-platform Compatibility | Seamless data exchange with X-Rite SP62 spectrophotometers |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci62 |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Portable |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Tungsten Halogen Lamp |
| Spectral Range | 400–700 nm |
| Repeatability (ΔE*ab) | ≤0.05 |
| Aperture Options | 4 mm, 8 mm |
| On-device Storage Capacity | Up to 4,000 measurements |
| Bluetooth Connectivity | Yes (CE, US, Canada, China, India, Japan, Korea, Taiwan) |
| Compatible Cloud Platform | NetProfiler 3.0 |
| Backward Compatibility | Full SP-series legacy support |
| Inter-instrument Agreement Optimized | Embedded spectral data conversion algorithms |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ci64 |
| Pricing | Upon Request |
| Aperture Options | 4 mm measurement / 6.5 mm target window |
| Light Source | Tungsten-halogen lamp |
| Inter-instrument Agreement (8 mm/14 mm or 14 mm/20 mm) | Avg. ΔE*ab = 0.13 (CIE L*a*b*, including SCI, based on 12 BCRA Series II tiles) |
| Inter-instrument Agreement (4 mm/6.5 mm) | Avg. ΔE*ab = 0.20 |
| Short-term Repeatability | 0.04 ΔE*ab (on white tile) |
| Data Interfaces | USB 2.0, Bluetooth v4.0 |
| Standard Accessories | Black trap, white & green calibration tiles, user manual, AC adapter, NetProfiler software, sample holder, bench stand, spare battery, dual-bay charger |
| Operating Modes | QA, Comparison, Opacity, Strength, Job & Project |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Product Type | Spectrophotometer |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Tungsten halogen lamp |
| Spectral Range | 400–700 nm |
| Repeatability | ΔE* < 0.04 (white tile, 10 readings) |
| Aperture Options | 4 mm, 8 mm, 14 mm (Ci64L variant) |
| On-device Storage | Up to 4,000 measurements |
| Connectivity | Optional Bluetooth (CE, US, CA, CN, IN, JP, KR, TW) |
| Software Integration | NetProfiler 3.0, PantoneLIVE™ cloud access, eXact™ compatibility |
| Compliance | ASTM E308, ISO/CIE 15, ISO 13655, DIN 5033, GB/T 3978–2008 |
| Backward Compatibility | Full SP-series legacy support with embedded spectral data conversion |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Product Type | Spectrophotometric Color Measurement Instrument |
| Instrument Type | Portable |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Tungsten Halogen Lamp |
| Spectral Range | 400–700 nm |
| Repeatability (ΔE*ab) | ≤0.04 |
| Aperture Options | 4 mm, 8 mm, 14 mm (Ci64 UV supports 4 mm and 8 mm) |
| Onboard Memory Capacity | Up to 4,000 samples |
| Connectivity | Bluetooth (CE, US, Canada, China, India, Japan, Korea, Taiwan) |
| Software Integration | NetProfiler 3.0, PantoneLIVE™ cloud access, eXact™ compatibility |
| Compliance | ASTM E308, ISO 11664-4, ISO 13655, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (via NetProfiler audit trail) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ci64UV |
| Pricing | Upon Request |
| Aperture Options | 4 mm measurement / 6.5 mm target window OR 8 mm measurement / 14 mm target window |
| Light Source | Tungsten Halogen Lamp + Adjustable UV LED |
| Inter-instrument Agreement (8 mm/14 mm, SCI) | Avg. 0.13 ΔE*ab (BCRA Series II, 12 tiles), Max 0.25 ΔE*ab (any planar surface) |
| Inter-instrument Agreement (4 mm/6.5 mm, SCI) | Avg. 0.20 ΔE*ab (BCRA Series II, 12 tiles), Max 0.40 ΔE*ab (any planar surface) |
| Short-term Repeatability | 0.04 ΔE*ab (on white tile) |
| Data Interfaces | USB 2.0, Bluetooth v4.2 |
| Standard Accessories | Black trap, white & green calibration tiles, UV calibration standard, user manual, AC adapter, NetProfiler software, sample holder, bench stand, spare battery, dual-bay charger |
| Operating Modes | QA, Comparison, Opacity, Strength, Project & Job |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7600 |
| Geometry | d/8° (SPIN & SPEX) |
| Short-Term Repeatability | ≤ 0.03 ΔE*ab RMS on white tile |
| Inter-instrument Agreement | ≤ 0.15 ΔE*ab avg. |
| Aperture Sizes (Reflectance) | 25 mm, 17 mm*, 10 mm, 6 mm, 3.5 mm* |
| Aperture Sizes (Transmittance) | 3 standard + 2 optional |
| Measurement Spot Sizes | 20 mm, 12 mm, 5 mm, 2.7 mm |
| Measurement Time | ≈ 2.5 s |
| Spectral Range | 360–750 nm |
| Spectral Interval | 10 nm (default), 20 nm selectable |
| Optical System | 2D CCD array with holographic grating |
| Illuminant | Pulsed xenon lamp, D65 calibrated |
| UV Control | Integrated UV filters (up to 3) |
| Photometric Resolution | 0.01% |
| Lamp Lifetime | ≥ 1,000,000 measurements |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | 5–85%, non-condensing |
| Dimensions (L×W×H) | 56 × 22 × 31 cm |
| Weight | 20.5 kg |
| Shipping Dimensions | 71 × 38 × 53 cm |
| Shipping Weight | 25 kg |
| Interface | USB 2.0 |
| Software Development Kit | XDS4 |
| Embedded NetProfiler | Yes |
| Internal Temp/Humidity Sensor | Yes |
| Laser Targeting | Yes |
| Sample Preview Camera | Yes |
| Status Panel | LED-based |
| Power | 100–240 VAC, 50–60 Hz |
| Warm-up Time | None required |
| Calibration Standards | Included white tile, black trap, UV calibration kit |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7600 |
| Product Type | Spectrophotometric Color Measurement Instrument |
| Instrument Form Factor | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 360–750 nm |
| Repeatability (ΔE*₀₀ RMS) | 0.03 |
| UV Control Option | Available |
| Internal Environmental Sensors | Temperature & Relative Humidity |
| Compliance | ASTM E308, CIE No. 15, ISO/CIE 11664, USP <85> (Colorimetric Assay Guidance) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7600 |
| Type | Automatic |
| Wavelength Range | 360–750 nm |
| ΔE* (SCI) Accuracy | 0.15 (avg.) |
| Repeatability (RMS ΔE*) | 0.03 |
| Photometric Resolution | 0.01% |
| UV Control Options | 420 nm UV, 460 nm UV Cutoff |
| Apertures | Transmission – 22 mm, 10 mm, 6 mm |
| Measurement Modes | Simultaneous SPIN/SPEX |
| Compliance | ASTM E308, CIE 15:2018, USP <85> (Colorimetric Analysis) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7800 |
| Geometry | d/8° (diffuse illumination, 8° viewing) |
| Short-term Repeatability (White Tile) | ≤ 0.01 ΔE*ab RMS |
| Inter-instrument Agreement | ≤ 0.08 ΔE*ab avg. |
| Spot Sizes | 25 mm, 17 mm, 10 mm, 6 mm, 3.5 mm |
| Aperture Sizes | 20 mm, 12 mm, 5 mm, 2.7 mm |
| Measurement Time | ≈ 2.5 s |
| Spectral Range | 360–780 nm |
| Spectral Interval | 10 nm (default), 5 nm, 20 nm |
| Spectral Reporting | 10 nm, 5 nm, 20 nm |
| Illuminant | Pulsed Xenon (D65 calibrated) |
| Photometric Range | 0–200% |
| Photometric Resolution | 0.00% |
| Detector | 2D CCD Array with Holographic Grating |
| Reflectance Apertures | 4 standard + 1 optional |
| Transmittance Apertures | 4 |
| UV Control | Up to 3 UV filters |
| Operating Humidity | 5–85% RH (non-condensing) |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −20–50 °C |
| Dimensions (L×W×H) | 56 × 22 × 31 cm |
| Weight | 20.5 kg |
| Shipping Dimensions | 71 × 38 × 53 cm |
| Shipping Weight | 25 kg |
| Interface | USB 2.0 |
| Software Development Kit | XDS4 |
| Built-in Camera | Yes (preview + active laser target positioning) |
| Embedded NetProfiler Support | Yes |
| Internal Temp/Humidity Sensors | Yes |
| Lamp Timer | Yes |
| UV Calibration Tools | White tile, black trap, UV reference standards |
| Compliance | ASTM E308, ISO/CIE 11664, ISO 7724, ISO 13655, USP <1061>, FDA 21 CFR Part 11 (via compatible software) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7800 |
| Product Type | Spectrophotometric Colorimeter |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Xenon flash lamp |
| Spectral Range | 360–780 nm |
| Repeatability (ΔE* RMS) | 0.01 |
| UV Control Option | Yes |
| Internal Temperature & Humidity Sensors | Yes |
| Transmission Apertures | 27, 17, 10, 6 mm |
| Reflectance Apertures | 25, 17, 10, 6, 3.5 mm |
| Compliance | ASTM E308, CIE No. 15, USP <857> |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7800 |
| Type | Automatic |
| Wavelength Range | 360–780 nm |
| ΔE* (SCI) Repeatability (RMS) | 0.01 |
| Average ΔE* (SCI) | 0.08 |
| Photometric Resolution | 0.001% |
| UV Calibration Options | 420 UV, 460 UV Cutoff |
| Illumination/Viewing Geometry | d/8° (SPIN & SPEX simultaneous) |
| Transmission Apertures | 27, 17, 10, 6 mm |
| Reflectance Apertures | 25, 17, 10, 6, 3.5 mm |