| Brand | Tydex |
|---|---|
| Origin | Russia |
| Model | ATS |
| Transmission Levels | 30%, 10%, 3%, 1% (individual) |
| Max Aperture | 54.5 mm |
| Spectral Range | Up to 1000 µm (extended operational range beyond 1 mm achievable) |
| Mounting | Modular wheel-based holder (5-position turret), optional standalone use |
| Customization | Empty wheel position supports user-supplied optics (e.g., bandpass filters, polarizers, substrates) |
| Compliance | Designed for high-power THz beam conditioning in research-grade systems |
| Brand | Tydex |
|---|---|
| Origin | Russia |
| Model | EOD-NIR |
| Detection Principle | Electro-Optic Sampling (EOS) with ZnTe or GaP Crystal |
| Optical Input | NIR (780–850 nm) Pump/Probe Beams |
| THz Bandwidth | 0.1–4 THz (typ.) |
| Delay Line Compatibility | Motorized or Manual Optical Delay Stage |
| Interface | USB 2.0 |
| Software OS Support | Windows XP, Vista, Windows 7 |
| Compliance | CE-marked for laboratory use |
| Dimensions | 120 × 85 × 60 mm |
| Weight | ~0.8 kg |
| Brand | Tydex |
|---|---|
| Origin | Russia |
| Model | TAD-1 |
| Frequency Range | 3–300 GHz |
| Pulse Width Measurement Range | 1–500 ns |
| Detection Principle | Thermophonic (RF-to-Acoustic Transduction) |
| Output Signal Type | Analog Voltage Proportional to Instantaneous RF Power |
| Compliance | Designed for Laboratory & High-Power RF Diagnostics Environments |
| Brand | TYDEX |
|---|---|
| Origin | Russia |
| Model | TSFPI / TSFPI-2 |
| Operating Frequency Range | 0.1–15 THz |
| Free Spectral Range (FSR) | 0.01–1.8 THz |
| Mirror Spacing | 0–9.5 mm (standard), 1.8 mm (compact variant) |
| Spectral Tuning Accuracy | ±1.25 µm |
| Clear Aperture | 52 mm |
| Optical Port Height | 110 mm |
| Dimensions (L×H×W) | 232×151×120 mm |
| Weight | 5.0 kg |
| Detector Compatibility | Tydex GP-1P photoacoustic detector |
| Brand | ULO Optics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Series | ULO CO₂ Optics |
| Core Category | Gas Laser System Components |
| Brand | ULO Optics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CO2mpact |
| Power Handling | ≤500 W |
| Wavelength Compatibility | 10.6 µm and 9.3 µm |
| Maximum Beam Diameter | 12 mm |
| Clear Aperture | 19 mm |
| Core Components | Mirror Mounts, Transfer Tubes, Beam Conduits, Manual Shutters, Reflective Isolators, Manual Attenuators |
| Mechanical Interface | Threaded Bushings for Modular Assembly |
| Mounting | Bench-mounted via Tube Clamps |
| Brand | Ekspla |
|---|---|
| Technology | OPCPA (Optical Parametric Chirped Pulse Amplification) |
| Repetition Rate | Up to 1 kHz |
| Pulse Energy | Up to 50 mJ |
| Pulse Energy Stability | <1.5% RMS |
| Average Power Stability | <1.5% RMS over >12 h |
| Wavelength Tuning | Motorized, Hands-Free |
| Patents | EP2827461, EP2924500 |
| Laser Type | Solid-State OPCPA System |
| Brand | Ekspla |
|---|---|
| Wavelength Range | 210–230 nm, 250–320 nm, 375–480 nm, 700–1010 nm |
| Repetition Rate | Up to 1 kHz |
| Pulse Energy | Up to 3 mJ |
| Pulse Duration | <35 fs (typical, at fundamental output) |
| Stability | <1.5% RMS (pulse-to-pulse and >12 h long-term) |
| Synchronization | Integrated femtosecond and picosecond output channels |
| Technology | Optical Parametric Chirped Pulse Amplification (OPCPA) |
| Front-End Design | Patented dequisection architecture (EP2827461, EP2924500) |
| Compliance | CE-marked, RoHS-compliant, designed for Class 4 laser facility integration |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | UltraScan PRO |
| Type | Benchtop Spectrophotometric Colorimeter |
| Optical Geometry | d/8° Integrating Sphere |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 350–1050 nm |
| Repeatability | ΔE*ab ≤ 0.02 (mean, CIE Lab) |
| Brand | ULVAC KIKO |
|---|---|
| Origin | Japan |
| Model | UNECS Series |
| Measurement Principle | Spectroscopic Ellipsometry (SE) |
| Wavelength Range Options | Standard: 530–750 nm |
| Visible-Extended | 380–760 nm |
| Minimum Acquisition Time | 20 ms per spectrum |
| Sensor Architecture | Fixed-optics, no rotating elements |
| Environmental Configurations | Ambient-air, vacuum-integrated, and in-situ chamber-mounted variants |
| Sample Stage Options | Manual, motorized XY, large-substrate (up to 300 mm), portable benchtop, and OEM-integrated modules |
| Compliance | Designed for ISO/IEC 17025-aligned calibration traceability |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | AS-36 |
| Cuvette Pathlength | 50 mm |
| Number of Positions | 4 |
| Dimensions (L×W×H) | 150 × 60 × 70 mm |
| Weight | 0.5 kg |
| Compatibility | Designed for UniCo UV-Vis spectrophotometers and standard 50 mm pathlength rectangular cuvettes |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | AS-37 |
| Cuvette Pathlength | 10 cm (100 mm) |
| Number of Slots | 4 |
| Dimensions (L×W×H) | 150 × 110 × 70 mm |
| Weight | 0.6 kg |
| Compatibility | Standard 10 cm rectangular quartz/glass cuvettes |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UNIK LASER UV-SLM Series |
| Core Technology | BRaMMS Patented DPSS Architecture |
| Output Wavelengths | 266 nm, 320 nm, 349 nm, 355 nm |
| Output Power Range | 10–200 mW (UV variants) |
| Beam Quality | TEM₀₀, M² < 1.1 |
| Relative Intensity Noise | < 0.1 % RMS |
| Spectral Linewidth | < 1 MHz |
| Coherence Length | > 100 m |
| Beam Pointing Stability | ≤ 5 µrad/°C |
| Power Supply | Integrated Low-Power Consumption Module |
| Form Factor | Compact Benchtop OEM-Compatible Housing |
| Brand | Universal |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ULCR-100 |
| Core Technology | Sealed-off RF-excited gas laser |
| Output Wavelength | 10.6 µm (standard), optional 9.3 µm |
| Output Power | 100 W (dual-resonator design) |
| Power Stability | ±5% |
| Beam Quality (M²) | 1.3 ± 0.2 |
| Beam Diameter | 4 ± 1 mm |
| Full Divergence Angle | 5 ± 1 mrad |
| Polarization | Linear (standard) |
| Beam Directional Stability | ≤200 µrad |
| Pulse Rise Time | 120 ± 40 µs |
| Max Pulse Frequency | 5 kHz (100% duty cycle capable) |
| Modulation Input | TTL-compatible |
| Cooling | Air-cooled or water-cooled |
| Operating Voltage | 48 VDC |
| Operating Current | 36 A |
| Enclosure Options | OEM Basic, OEM Standard, Class IV Safety-compliant |
| Compliance | IEC 60825-1:2014, FDA 21 CFR 1040.10/1040.11, CE marking (for Class IV variants) |
| Brand | Universal |
|---|---|
| Origin | USA |
| Model | ULCR-50 |
| Output Power | 50 W |
| Wavelength | 10.6 µm or 9.3 µm |
| Beam Quality (M²) | 1.3 ± 0.2 |
| Power Stability | ±5% |
| Beam Diameter | 4 ± 1 mm |
| Beam Divergence (Full Angle) | 5 ± 1 mrad |
| Polarization | Linear |
| Beam Directional Stability | 200 µrad |
| Pulse Rise Time | 120 ± 40 µs |
| Max Pulse Frequency | 5 kHz |
| Modulation Input | TTL |
| Cooling | Air or Water |
| Supply Voltage | 48 VDC |
| Supply Current | 18 A |
| Operating Mode | CW or Pulsed |
| RF Excitation | Integrated |
| Safety Class | Class 4 (configurable) |
| Compliance | CE, FDA 21 CFR Part 1040.10/1040.11, IEC 60825-1 |
| Brand | UPRtek |
|---|---|
| Origin | Taiwan |
| Model | MD100N |
| Spectral Range | 380–780 nm |
| Spectral Resolution | 1 nm |
| FWHM | ~12 nm |
| Measurement Area | Ø10 mm |
| Field of View | ±1° |
| Luminance Range | 0.001–5000 cd/m² |
| Luminance Accuracy | ±2% (100–5000 cd/m²), ±3% (0.2–100 cd/m²), ±4% (0.05–0.2 cd/m²) |
| Chromaticity Accuracy | ±0.002 CIE1931 x,y (100–5000 cd/m²), ±0.003 (0.2–100 cd/m²), ±0.005 (0.05–0.2 cd/m²) |
| Stray Light | ≤−25 dB |
| Polarization Error | <2% |
| Integration Time | 100 µs–5000 ms |
| Digital Resolution | 16-bit |
| Flicker Sampling Rate | up to 100 kS/s |
| Dimensions | 204 × 90 × 45 mm |
| Weight | 630 g ±10 g |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Yes |
| Model | MF250N |
| Price | USD 1,180 (FOB) |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | China (Domestic) |
| Model | MF250N |
| Price Range | USD 0–7,200 |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Yes |
| Model | MK350D |
| Pricing | Available Upon Request |
| Instrument Type | Silicon CMOS Linear Array Spectrometer (Not Selenium Cell) |
| Spectral Bandwidth (FWHM) | ~12 nm |
| Spectral Range | 380–780 nm |
| Illuminance Range | 70–70,000 lx |
| Cosine Correction Aperture | Ø6.6 ± 0.1 mm |
| Wavelength Sampling Interval | 1 nm |
| Wavelength Repeatability | ±1 nm |
| CCT Accuracy | ±2% (vs. Standard Illuminant A at 2856 K) |
| CIE x,y Chromaticity Accuracy | ±0.0025 |
| Repeatability | ±0.0005 |
| CRI (R1–R15) Accuracy | ±1.5% |
| Flicker Measurement Range | 1–100%, Frequency: 10–165 Hz, Accuracy: ±5% |
| Display | 0.96" 128×64 monochrome OLED |
| Battery | 700 mAh rechargeable Li-ion, ≤3 h operation |
| Dimensions | 33 × 33 × 90 mm |
| Weight (incl. battery) | 70 ± 5 g |
| Operating Temp. | 0–35 °C |
| Storage Temp. | −10–40 °C |
| Data Storage | MicroSD (up to 2 GB, ~2000 records) |
| Connectivity | Bluetooth 3.0/4.0 (iOS/Android), Mini USB 2.0 |
| Software | uSPECTRUM PC Suite |
| Output Format | CSV/Excel-compatible |
| Resolution | 16-bit ADC |
| Stray Light Rejection | ≤−25 dB (at ±40 nm from 550 nm) |
| Measurement Modes | Single / Continuous |
| Supported Color Spaces | CIE 1931 xy, CIE 1976 u'v' |
| Metrics | CCT, CRI (R1–R15, R9), λP, Illuminance (lx, fc), Flicker %, Flicker Index, Pst, SVM |
| Brand | UPRtek |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Asia-Pacific Manufactured |
| Model | MK550T |
| Price Range | USD 6,800 – 13,600 |
| Brand | CLEAN |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Asia-Pacific Manufactured |
| Model | PG200N |
| Price Range | USD 700–1,400 |
| Instrument Type | Silicon Photodiode-Based Spectroradiometer with PAR-Optimized CMOS Linear Sensor |
| Spectral Range | 350–800 nm |
| Wavelength Resolution | 1 nm |
| FWHM | ~12 nm |
| Cosine Correction | CIE 1990 Compliant |
| Accuracy (Illuminance) | ±5% @ Standard Illuminant A (2856 K, 20,000 lx) |
| PPFD Range | 1–3,000 µmol/(m²·s) |
| Irradiance Range | 0.5–1,000 W/m² |
| Lux Range | 70–150,000 lx |
| Repeatability (2σ) | 0.2% |
| Colorimetric Accuracy | ±0.0025 in CIE 1931 x,y |
| CCT Accuracy | ±2% |
| CRI Accuracy | ±1.5% |
| IP Rating | IP66 |
| Display | 4.3" capacitive touch LCD (800×480) |
| Battery Life | Up to 5 hours (2500 mAh Li-ion) |
| Data Storage | ~68,000 records on 8 GB microSD |
| Connectivity | USB-C, Bluetooth 5.0, microSD |
| Operating Temp | 0–35 °C, ≤70% RH (non-condensing) |
| Weight | 280 g ±10 g |
| Compliance | JIS C 1609-1:2006 Class AA, DIN 5032-7 Class B |
| Brand | UpTek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MF250N |
| Price Range | USD 1,400 – 4,200 |
| Brand | UpTek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MK350N |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Display | 3.5″ capacitive touchscreen |
| Connectivity | Bluetooth 4.0 (iOS & Android compatible) |
| Measurement Modes | Single-shot & Continuous (1 Hz update rate) |
| Output Formats | CSV, Excel (.xlsx), BMP |
| Storage | microSD card (1–32 GB) |
| Calibration | NML/CMS-compliant spectral calibration with auto-dark correction routine |
| Spectral Range | 360–780 nm |
| Optical Resolution | ≤ 8 nm (FWHM) |
| Illuminance Range | 0.01–99,999 lx |
| CCT Accuracy | ±50 K (2000–10,000 K) |
| CRI (Ra) Uncertainty | ±1.5 (CIE 13.3–1995) |
| Chromaticity Coordinates | CIE 1931 (x,y) & CIE 1976 (u',v') |
| Peak Wavelength Detection | Yes |
| Spectral Data Export | Full spectrum (1 nm step) |
| Brand | UpTek |
|---|---|
| Origin | USA |
| Model | MK350S |
| Display | 3.5″ capacitive touchscreen |
| Measurement Modes | Single-shot, continuous (1 Hz update rate) |
| Spectral Range | 380–780 nm |
| Spectral Resolution | ≤ 5 nm |
| Illuminance Range | 0.01–99,999 lux |
| CCT Range | 1,000–100,000 K |
| Color Spaces | CIE 1931 xy, CIE 1976 u’v’ |
| Data Storage | microSD card (up to 32 GB) |
| Output Formats | CSV, Excel (.xlsx), BMP |
| Connectivity | Wi-Fi (iOS/Android app support), USB-C |
| Calibration Compliance | NML/CMS traceable |
| Dark Calibration | Auto-executable on startup |
| Operating Temperature | 5–35 °C |
| Battery Life | ≥ 6 hours (Li-ion rechargeable) |
| Brand | UpTek |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Phidia-10-FS/HFS |
| Core Component | Solid-State Femtosecond Laser System |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Origin | Yes |
| Model | MK350 |
| Price | Upon Request |
| Wavelength Range | 340–750 nm |
| Optical Resolution (FWHM) | 12 nm |
| Digital Resolution | 16-bit |
| Display | 3.5-inch full-color capacitive touchscreen (320 × 240) |
| Data Storage | SD card (Excel for spectral data, BMP for graphical displays) |
| Interface | USB 2.0 |
| Power | Rechargeable lithium-ion battery |
| Weight | 200 g |
| Dimensions | 144.2 × 78.0 × 24.0 mm |
| Measurement Capabilities | Relative spectral power distribution, Correlated Color Temperature (CCT), Color Rendering Index (CRI Ra), Illuminance (Lux), Dominant Wavelength (λ<sub>P</sub>), CIE 1931 (x, y) chromaticity coordinates, CIE 1976 (u′, v′) chromaticity coordinates |
| Brand | Laser-Laboratorium Göttingen e.V. |
|---|---|
| Origin | Germany |
| Model | UV-fs-compact |
| Wavelength | 248 nm |
| Pulse Energy | 10 mJ per pulse |
| Repetition Rate | 0–10 Hz |
| Beam Dimensions | 25 × 25 mm² |
| Beam Quality | M² ≈ 1.5 (input M² = 1) |
| Pump Source | Excimer-laser-pumped dye laser system with dual-discharge amplification stage |
| Configuration | Integrated, turnkey ultrafast UV source |
| Brand | Laser-Laboratorium Göttingen e.V. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UV-fs-vario |
| Core Technology | Ti:sapphire-seeded UV femtosecond laser system with automated tripling stage |
| Central Seed Wavelength | 745.5 nm |
| Synchronization | Integrated precision timing module for long-term seed-amplifier synchronization |
| Brand | BJBY |
|---|---|
| Model | UV254M |
| Spectral Range | 220–275 nm |
| Display | Dual 4-digit LCD with backlight |
| Measurement Ranges | High/Low auto-ranging |
| Mounting | Standard 1/4″-20 tripod socket |
| Calibration | NIST-traceable certificate included |
| Data Logging | Auto-record mode with 20-point memory |
| Zero Adjustment | Manual offset compensation |
| Power | Battery-operated with low-battery indicator |
| Compliance | Meets ISO/CIE spectral responsivity requirements for UVC radiometry |