Optical Measurement Instruments
Filter
Showing 3691–3720 of 3889 results
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7860 |
| Product Type | Benchtop Spectrophotometer |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Illuminant | UV-Enabled |
| Spectral Range | 360–780 nm |
| Repeatability (RMS ΔE*) | 0.01 |
| Inter-instrument Agreement (Avg. ΔE* SCI) | 0.06 |
| Spectral Resolution | 10 nm |
| Photometric Resolution | 0.001% |
| UV Filter Options | Standard 400 nm, Optional 420 nm & 460 nm |
| Reflectance Apertures | 25 mm, 17 mm, 10 mm, 6 mm, 3.5 mm (optional) |
| Transmittance Apertures | 27 mm, 17 mm, 10 mm, 6 mm |
| Dual-Mode Measurement | SPIN & SPEX Simultaneous |
| Compliance | CIE 15:2018, ASTM D2244, ASTM E308, ISO 7724-1, ISO 13655, ISO 17972-1 (PantoneLIVE), FDA 21 CFR Part 11 (with Color iQC v6.0+) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | CiF3200 |
| Aperture Options | 2 mm, 4 mm, 8 mm, 12 mm (virtual) |
| Illumination Geometry | d/8° (diffuse illumination, 8° viewing) |
| Spectral Range | 400–700 nm at 10 nm intervals |
| Optical Resolution | 10 nm |
| Measurement Time | ~15 s |
| Measurement Distance | 0 mm (contact mode) |
| Repeatability (White Tile) | ≤0.025 ΔE* (SPIN) |
| Inter-instrument Agreement (BCRA Tiles) | ≤0.15 ΔE* (SPIN) |
| Light Source | LED (≥500,000 measurements lifespan) |
| Spectral Report Output | Full reflectance spectrum (400–700 nm, 10 nm step) |
| Display | Integrated high-resolution touchscreen |
| Connectivity | USB |
| Operating Temperature | 10–40 °C |
| Storage Temperature | −20–70 °C |
| Humidity Range | 0–85% RH (non-condensing) |
| Power Supply | Universal AC input (100–240 VAC) |
| Weight | ~4 kg |
| Enclosure Color | Black & silver |
| Warranty | 12 months |
| Software Integration | Compatible with X-Rite Color iQC, supported SDK for custom integration |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci™4200 / Ci™4200UV |
| Optical Geometry | d/8° with DRS spectral engine |
| Illumination/Measurement Apertures | 14 mm illuminating / 8 mm measuring |
| Light Source | Tungsten-halogen lamp (Ci™4200) |
| Detector | Blue-enhanced silicon photodiode |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (acquisition and output) |
| Reflectance Range | 0–200% |
| Inter-instrument Agreement | Avg. 0.20 ΔE*ab (CIE L*a*b*, BCRA Series II, SCI mode, including specular component) |
| Short-term Repeatability | 0.05 ΔE*ab (white tile, SCI) |
| Measurement Time | ~2 s (simultaneous SCI/SCE) |
| UV Calibration Support | Yes (Ci™4200UV only) |
| Gloss Measurement | 60° gloss data output |
| Transform Support | Yes |
| Lamp Lifetime | ~500,000 measurements |
| Power Supply | 90–130 VAC or 100–240 VAC, 50–60 Hz, max 15 W |
| Interface | USB |
| Operating Temp. | 10–40°C, ≤85% RH (non-condensing) |
| Storage Temp. | −20–50°C |
| Weight | 5.2 kg |
| Dimensions | 22.0 × 19.0 × 26.4 cm (H × W × L) |
| Accessories | Black trap, white/green calibration tiles, UV calibration standard (Ci™4200UV), power adapter, USB cable, user manual |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci™4200 / Ci™4200UV |
| Type | Automatic |
| Optical Geometry | d/8° with DRS (Diffuse/8° Reflectance Sphere) |
| Illumination/Measurement Aperture | 14 mm illuminating / 8 mm measuring |
| Light Source | Tungsten-halogen lamp (Ci™4200), UV-LEDs (Ci™4200UV) |
| Detector | Blue-enhanced silicon photodiode |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (acquisition & output) |
| Reflectance Range | 0–200% |
| Inter-instrument Agreement | Avg. ΔE*ab ≤ 0.20 (CIE L*a*b*, BCRA Series II, SCI mode), Max. ΔE*ab ≤ 0.40 per tile (SCI) |
| Short-term Repeatability | ≤ 0.05 ΔE*ab (white tile) |
| Measurement Time | ~2 seconds (simultaneous SCI/SCE) |
| Gloss Output | 60° gloss units |
| Compliance | ASTM E308, ISO 7724, ISO 11664, CIE No. 15, USP <1061>, FDA 21 CFR Part 11 (via software audit trail) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Color iMatch / Color iQC Version 6.2 |
| Software Version | 6.2 |
| Compliance | ASTM D2244, ISO 11664-4, CIE No. 15:2018, CxF3 v3.0 Support |
| Data Export | Spectral Reflectance (360–740 nm), CIE L*a*b*, L*C*h°, ΔE00, ΔE76, Tolerancing (Asymmetric LABtol & LCHtol) |
| Hardware Integration | Compatible with X-Rite eXact, Ci7x00, SP series spectrophotometers |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | 7000A |
| Repeatability (White Tile) | 0.01 RMS ΔE (CIE Lab) |
| Inter-instrument Agreement (LAV) | 0.08 avg. ΔE (CIE Lab) |
| Light Source | Pulsed Xenon Arc |
| Measurement Time | < 1 s |
| Spectral Range | 360–700 nm |
| Wavelength Accuracy | ±0.1 nm (400–700 nm) |
| Wavelength Precision | ±0.05 nm (400–700 nm) |
| Wavelength Interval | 10 nm |
| Reflectance Range | 0–200% |
| Resolution | 0.01% |
| Apertures | LAV (25.4 mm), MAV (15.2 mm), SAV (7.5 × 10 mm), VSAV (3.0 × 8.0 mm) |
| Geometry | d/8° (diffuse illumination / 8° viewing) with 152 mm integrating sphere |
| Transmission Mode | Direct & Diffuse |
| UV Control | Motorized, D65-matched UV compensation with two preset UV bands |
| Mirror Finish Compensation | Motor-driven specular component exclusion (SCI/SCE) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | eXact™ |
| Type | Motorized Scanning Spectrodensitometer |
| Compliance | ISO 13655:2017 (M0/M1/M2/M3), ISO 12233, ASTM E308, CIE No. 15 |
| Connectivity | Bluetooth 4.2, USB-C, Wi-Fi (802.11 b/g/n) |
| Measurement Modes | Spot, Strip Scan (up to 112 cm / 44 in), Grid Scan, Registration Mark Detection |
| Supported Print Processes | Offset, Gravure, Flexo, Digital, Screen |
| Optical Geometry | d/8° (diffuse illumination / 8° viewing), with optional polarization filter for M2/M3 |
| Spectral Range | 360–740 nm, 10 nm resolution |
| Aperture Options | 3 mm, 4.5 mm, 8 mm |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | eXact™ |
| Aperture Options | 1.5 mm, 2 mm, 4 mm, 6 mm |
| Battery | Li-ion, 7.4 VDC, 2200 mAh |
| Color Difference Metrics | CIE ∆E* (1976), ∆ECMC, CIE ∆E* (2000), CIE ∆E* (1994) |
| Color Spaces | CIE L*a*b*, CIE L*C*h° |
| Density Range | 0.0 D – 3.0 D |
| Density Standards | Status A, E, I, T, G |
| Dimensions | 18 cm × 7.8 cm × 7.6 cm (7.1" × 3.1" × 3.0") |
| Illuminants | A, C, D50, D55, D65, D75, F2, F7, F11, F12 |
| Communication | USB 2.0 |
| Measurement Geometry | 45°/0° annular illumination per ISO 5-4:2009(E) |
| Observer Angles | 2° and 10° |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm |
| Measurement Time | < 1 sec |
| Inter-instrument Agreement | Avg. 0.25 ΔEab, Max 0.45 ΔEab (M0/M2), 0.55 ΔEab (M3) |
| Short-term Repeatability | ±0.01 D (density, CMYK), 0.05 ΔEab (white BCRA std dev) |
| Operating Temp | 10–35°C (50–95°F) |
| Storage Temp | −20–50°C (−4–122°F) |
| Relative Humidity | 30–85% RH (non-condensing) |
| Embedded Capabilities | G7 Certification, NetProfiler, PantoneLIVE, BestMatch Auto-Calibration |
| Software Compatibility | X-Rite ColorCert, Color iQC, InkFormulation, NetProfiler, SDK support |
| Compliance | ISO 5-4:2009(E), ISO 13655:2009, ISO 12233 (for M-mode spectral validation) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-Rite IntelliTrax |
| Pricing | Available Upon Request |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Judge QC |
| Light Sources | D50, D65, CWF, UVA, CIE A, TL83, TL84, U30, U35 |
| Total Lamp Count | 5 |
| Viewing Chamber Dimensions (L×W×H) | 25 in × 18.5 in × 15 in (63.5 cm × 47 cm × 38 cm) |
| External Dimensions (L×W×H) | 27 in × 21.5 in × 21 in (68.5 cm × 54.5 cm × 53.5 cm) |
| Weight | 60 lbs (27 kg) |
| Shipping Weight | 70 lbs (31.5 kg) |
| Operating Temperature | 32–104°F (0–40°C) |
| Storage Temperature | 32–104°F (0–40°C) |
| Humidity Range | 0–95% RH (non-condensing) |
| Lamp Life | 2000 hours |
| Power Input | 100/115/127/230 V AC |
| Max Power Consumption | 65 W |
| Warm-up Time | 3 min (fluorescent lamps) |
| UV Metamerism Index | Class C (per CIE Technical Report 51.2-1999) |
| Visual Metamerism Index | Class B (per CIE Technical Report 51.2-1999) |
| Compliance | ISO 3664, ASTM D1729, ASTM E308, AATCC Evaluation Procedure 1, BSI BS 950-1 |
| Construction Material | Steel |
| Surface Finish | Munsell N7 gray interior |
| Interface | Touchscreen display with status LEDs |
| Lamp Timer | Integrated |
| Safety Certification | ETL Listed |
| UV Lamp Included | Yes |
| Internal Temp/Humidity Sensors | None |
| Calibration | Not internally calibrated (requires external verification per ISO/IEC 17025 or internal SOP) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Judge QC |
| Light Sources | D65, TL84, CWF, F/A, UV |
| Compliance | ASTM D1729, ISO 3664:2009, ISO 9001, ISO/IEC 17025 (supporting) |
| Dimensions (W×D×H) | 610 × 457 × 305 mm |
| Viewing Area | 508 × 356 mm |
| Lamp Life | ≥2000 h (D65, TL84, CWF), ≥1500 h (UV) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | MA-5 QC |
| Measurement Angles | 5 (r45as15, r45as25, r45as45, r45as75, r45as110) |
| Illuminant Options | D65, A, C, D50, F2, F7, F11, F12 |
| Observer Angle | 2° & 10° |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm |
| Aperture Size | Ø ≈ 12 mm |
| Measurement Time | 2.5 s |
| Repeatability (White Tile) | ≤ 0.02 ΔE* |
| Inter-instrument Agreement (BCRA Set) | 0.18 ΔE* avg |
| Display | 2.8″ QVGA TFT resistive touchscreen (240 × 320) |
| Operating Temp. | 10–40 °C |
| Storage Temp. | −20–50 °C |
| Relative Humidity | ≤ 85 % RH |
| Weight | 0.6 kg |
| Dimensions (L×W×H) | 180 × 70 × 95 mm |
| Light Source | White LED (10-year lifetime) |
| Battery | Rechargeable Li-ion (≥2000 cycles) |
| Connectivity | USB 2.0 |
| Software Mode | MA-94 Emulation |
| Data Storage | 1000 samples |
| Supported Languages | English, French, Italian, Spanish, German, Portuguese, Chinese, Japanese, Korean |
| Compliance | ISO 13655:2017, ASTM E308, CIE No. 15:2018, DIN 6175-2, ISO 12647-2 |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | MA-T6 / MA-T12 |
| Product Type | Multi-Angle Spectrophotometer |
| Instrument Type | Portable |
| Optical Geometry | 0/45° integrating sphere |
| Light Source | Full-spectrum white LED with blue-enhancement |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (31 data points) |
| Reflectance Range | 0–600% |
| Repeatability | ΔE* < 0.10 (gray BCRA tiles), ΔE* < 0.25 (colored BCRA tiles) |
| Inter-instrument Agreement | 0.18 ΔE2000 (BCRA reference tiles) |
| Measurement Angles | MA-T6 — 6 angles (15° illumination, 6 receiver positions) |
| Effect Parameters | Sparkle, Graininess, Distinctness of Image (DOI)-equivalent flop index |
| Sparkle Reproducibility | ±1.9% (mean error) |
| Graininess Reproducibility | ±1.4% (mean error) |
| Sparkle Repeatability | ±0.12% (mean error) |
| Graininess Repeatability | ±0.09% (mean error) |
| Display | 3.5-inch color touchscreen (8.9 cm) |
| Measurement Time | 4 s acquisition + 1.5 s calculation |
| Calibration | Internal black trap & white tile |
| Calibration Interval | Recommended every 30 days |
| Connectivity | USB 2.0, Wi-Fi |
| Storage Capacity | >2,000 samples + 600 images |
| Power | Rechargeable Li-ion battery (7.4 VDC, 2400 mAh) |
| Operating Temperature | 10–50 °C, ≤85% RH (non-condensing) |
| Storage Temperature | −20–50 °C, ≤85% RH (non-condensing) |
| Dimensions | 26.6 × 9.5 × 12.8 cm (L×W×H) |
| Weight | 1.2 kg |
| Compliance | ASTM D2244, E308, E1164, E2194, E2539 |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | MA68 II |
| Type | Automatic Portable Multi-Angle Spectrophotometer |
| Measurement Geometry | 45° illumination / 15°, 25°, 45°, 75°, 110° viewing angles (measured from specular reflection direction) |
| Angular Accuracy | ±0.15° |
| Aperture | 12 mm (0.5 in) |
| Color Spaces | CIELAB, LCH, ΔL*Δa*Δb*, ΔL*ΔC*ΔH*, ΔFlopIndex, FlopIndex, ΔE*ab, ΔE*cmc(2:1) |
| Illuminants | C, D65, D50, A, F2, F7, F11, F12 |
| Observer Angles | CIE 2° & 10° standard observer |
| Spectral Range | 400–700 nm |
| Spectral Interval | 28 bands (10 nm resolution from 400–640 nm |
| Detector | Blue-enhanced silicon photodiode |
| Reflectance Range | 0–400% |
| Repeatability | ≤0.08 ΔE*ab (short-term, white tile) |
| Measurement Time | ~2 seconds per full 5-angle acquisition |
| Data Interface | RS-232 (bidirectional, 300–19200 baud) |
| Display | 4-line × 20-character dot-matrix LCD |
| Power | Removable NiMH battery pack (6 × AA, 7.2 VDC, 1100 mAh) or AC adapter (90–130 VAC, 50–60 Hz, max 20 W) |
| Battery Life | ~1000 measurements per full charge (5-angle simultaneous mode) |
| Operating Temperature | 10–40 °C, ≤85% RH (non-condensing) |
| Storage Temperature | −20–50 °C |
| Dimensions | 22.5 × 7.6 × 11.6 cm (L×W×H) |
| Weight | 1.4 kg |
| Compliance | Meets CIE No. 15:2018, ISO/CIE 11664 series, ASTM D2244, ASTM E308, ISO 12647-2, ISO 13655, and supports GLP/GMP data integrity requirements via optional software audit trails |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | MetaVue VS3200 |
| Measurement Geometry | 45/0 |
| Spectral Range | 400–700 nm @ 10 nm resolution |
| Inter-instrument Agreement | Avg. ΔE*ab ≤ 0.15 |
| Repeatability (White Tile) | ≤ 0.025 ΔE*ab |
| Aperture Sizes | 2 mm, 4 mm, 6 mm, 8 mm, 10 mm, 12 mm |
| Sample Position Sensing | Yes |
| Lamp Lifetime | ≥ 350,000 measurements |
| Measurement Cycle Time | < 10 s |
| Compliance Standards | ASTM D2244, ASTM E179, ASTM E308, ASTM E1164, CIE 15, DIN 5033-7, DIN 5036, DIN 6174, ISO 7724-1/2/3, JIS Z 8722 |
| Backward Compatibility | X-Rite VS450 and 964 data formats |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | PANTONE 3 |
| Light Sources | D50 (with CWF), D65 (with TL84), CIE Illuminant A |
| Lamp Life | 2000 hours |
| Preheat Time | 3 min (fluorescent) |
| Power Consumption | ≤50 W |
| Operating Temperature | 0–40 °C |
| Storage Temperature | 0–40 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Viewing Chamber Dimensions | 68.5 × 39.5 × 35 cm |
| External Dimensions | 69 × 50 × 42 cm |
| Weight | 23.5 kg (unit), 27.5 kg (shipping) |
| Construction | Powder-coated aluminum |
| Metamerism Index | C-grade per CIE TR 51.2-1999 |
| Compliance | ISO 3664, ASTM D1729, ASTM E308, AATCC TM19, BSI BS 950-1 |
| Warranty | 1–2 years |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | RM200QC |
| Product Type | Portable Color Difference Meter |
| Optical Geometry | 45°/0° Imaging Sphere |
| Light Source | Independent Triple-Directional 25-LED Array (8 × Visible, 1 × UV) |
| Illuminant/Observer | D65/10° & A/10° |
| Standard/ Sample Memory | 20 / 350 |
| Measurement Time | 1.8 s |
| Aperture Options | 4 mm & 8 mm |
| Short-Term Repeatability | ≤0.1 ΔE₉₄ (D65/10°, White Tile) |
| Display | 4.5 cm Full-Color TFT |
| Interface | USB Mass Storage Mode |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 20–80% RH (non-condensing) |
| Altitude Limit | ≤2000 m |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | RM200QC |
| Instrument Type | Portable |
| Optical Geometry | d/8° integrating sphere (with 45/0 imaging mode) |
| Light Source | Tungsten-halogen lamp + UV LEDs (Ci4200UV) |
| Spectral Range | 400–700 nm |
| Repeatability | 0.05 ΔE*ab (typical, white tile, D65/10°) |
| Measurement Apertures | 4 mm and 8 mm |
| Measurement Time | 1.8 s |
| Standard Memory | 20 |
| Sample Memory | 350 |
| Display | 4.5 cm color TFT LCD |
| Interface | USB Mass Storage Class |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 20–80 % RH (non-condensing) |
| Altitude Limit | 2000 m |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | SpectraLight QC |
| Light Sources | 7 (D50/D65, CWF, UVA, U30/U35/TL84 — two selectable, CIE A, Horizon) |
| UV Output Monitoring | Yes |
| UV Metamerism Index | Grade B |
| Visual Metamerism Index | Grade A |
| Lamp Life | 400–2000 h |
| Illuminance Control | Digital light sensor with instant-on capability |
| Observation Chamber Dimensions | 90 cm × 58 cm × 58 cm (L×W×H) |
| External Dimensions | 945 mm × 700 mm × 610 mm (W×H×D) |
| Operating Temperature | 0–35 °C |
| Storage Temperature | −40–70 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Power Input | 100/115/230 V AC |
| Power Consumption | 1150 W |
| Compliance Standards | ISO 3664, ISO 3668, ISO 13076, ISO 23603, AATCC EP9, ASTM D1729, SAE J361, DIN 6173, CIE S012/E & 51.2, BSI BS 950 Pt.2 |
| Calibration | Factory-calibrated with built-in lamp-hour counter and UV output compensation |
| Safety Certification | UL-listed |
| Display | Touch-enabled LCD interface |
| Supported Languages | English, Chinese |
| Lamp Timer | Integrated |
| Service Indicator | Yes |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | SpectraLight QC |
| Light Sources | D65, A, CWF, U30, TL83, TL84, UV |
| Illuminance Control | Closed-loop digital lux regulation with integrated photometric sensor |
| UV Output | Factory-calibrated and user-adjustable |
| Compliance | ASTM D1729, ASTM E308, ISO 3664:2009, ISO 9001, AATCC Evaluation Procedure 1 |
| Illuminance Range | 500–2000 lx (adjustable per standard) |
| Stability | <30 sec thermal stabilization between sources |
| Calibration | NIST-traceable factory calibration for visible and UV channels |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 964 |
| Pricing | Upon Request |
| Measurement Geometry | 0°/45° |
| Spectral Sensor | DRS (Diffuse Reflectance Spectrometer) |
| Aperture Options | 4 mm measuring / 6.5 mm illuminating |
| Light Source | Pulsed Tungsten-Halogen Lamp |
| Standard Illuminants | C, D50, D65, D75, A, F2, F7, F11, F12 |
| Standard Observer Angles | 2° and 10° |
| Detector | Blue-Enhanced Silicon Photodiode |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (acquisition & output) |
| Memory Capacity | 1,024 standards (with tolerances), 2,000 sample measurements |
| Inter-instrument Agreement (7 mm/15 mm) | Avg. 0.15 ΔE*ab (BCRA II avg.), Max. 0.30 ΔE*ab (any BCRA II) |
| (4 mm) | Avg. 0.20 ΔE*ab (12 BCRA II), Max. 0.40 ΔE*ab |
| Short-Term Repeatability | 0.05 ΔE*ab (white tile, SD of 20 readings) |
| Reflectance Range | 0–200% |
| Measurement Time | ~2 s |
| Lamp Lifetime | ~500,000 measurements |
| Power | Removable NiMH rechargeable battery pack |
| AC Adapter | 90–130 VAC or 100–240 VAC, 50–60 Hz, max. 15 W |
| Charge Time | ~4 h to full capacity |
| Measurements per Charge | ~1,000 (within 8 h) |
| Display | 128 × 256 pixel monochrome LCD |
| Data Interface | Bidirectional RS-232, baud rate 300–57,600 |
| Operating Temperature | 10–40 °C (50–104 °F) |
| Max. Relative Humidity | 85% RH (non-condensing) |
| Storage Temperature | −20–50 °C (−4–122 °F) |
| Weight | 1.1 kg (2.4 lb) |
| Dimensions (H×W×L) | 10.9 × 8.4 × 19.6 cm (4.3″ × 3.3″ × 7.7″) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | VeriColor® Spectro |
| Type | Automatic |
| IP Rating | NEMA-4 / IP67 |
| Operating Temperature | 0–50°C (32–122°F) |
| Measurement Distance | 4 inches (102 mm) |
| Spectral Resolution | 31-channel, 10 nm bandwidth across visible spectrum (400–700 nm) |
| Output | Absolute CIE L*a*b* values |
| Interface | RS-232, RS-485, PLC-compatible discrete I/O |
| Compliance | Designed for GLP/GMP environments with audit-ready data logging capability |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | VS 450 |
| Instrument Type | Spectrophotometer with Gloss Sensor |
| Geometry | 45/0° dual illumination |
| Light Source | Full-spectrum LED |
| Optical Design | True dual-beam, 31-channel spectral engine |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (measurement and output) |
| Reflectance Range | 0–150% |
| Measurement Spot Sizes | 6 mm and 12 mm |
| Measurement Distance | 38 mm (lens-to-sample) |
| Short-term Repeatability | ≤0.035 ΔEab (6 mm, white tile), ≤0.025 ΔEab (12 mm, white tile) |
| Inter-instrument Agreement | ≤0.15 avg. ΔEab (12 BCRA tiles) |
| Gloss Geometry | 45° and 60° |
| Gloss Repeatability | ±0.2 GU (0–10 GU), ±0.6 GU (10–100 GU) |
| Gloss Reproducibility | ≤3.0 GU max (5–92 GU), ≤1.5 GU avg |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 0–85% RH (non-condensing) |
| Power Supply | 24 V ±2 V DC, 1.2 A max |
| Interface | USB 2.0 |
| Dimensions (L×W×H) | 24.8 × 15.24 × 14.6 cm |
| Weight | 2.24 kg |
| Safety Compliance | UL 61010-1, CSA C22.2 No. 1010.1, IEC/EN 61010-1 |
| Altitude Limit | ≤2000 m |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Lamp Lifetime | >20 million measurements |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | XFT-1 |
| Price | Upon Request |
| Wavelength Range | 400–800 nm |
| Spectral Bandwidth | 1 nm |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | XGP Series |
| Price Range | USD 1–1,400 |
| Instrument Type | Automatic |
| Haze Range | 0–30% |
| Transmittance Range | 0–100% |
| Haze Repeatability | ±0.2% |
| Transmittance Repeatability | ±0.5% |
| Gloss Measurement Angles | 20°, 60°, 85° (configurable as single/dual/triple-angle) |
| Gloss Range | 0–199.9 GU |
| Resolution | 0.1 GU |
| Accuracy | ±1.0 GU (per JJG 696 Class 1) |
| Stability | ±0.4 GU/30 min |
| Light Source | Long-life imported LED (≥100,000 h) |
| Angle Tolerance | ≤0.03° |
| Calibration | Auto-zero, Quartz Reference Standards |
| Power | Ni-MH rechargeable battery (12 h charge → ≥80 h continuous operation) |
| Brand | JHX (Infracont) |
|---|---|
| Origin | Hungary |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | XGrain |
| Pricing | Available Upon Request |
| Brand | Xiton |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | IMPACT Series |
| Core Component | Diode-Pumped Nanosecond Solid-State Laser System |
| Wavelength Options | 1064 nm (fundamental), 532 nm (second harmonic), 355 nm (third harmonic) |
| Average Power | Up to 12 W @ 1064 nm, 6.0 W @ 532 nm, 3.0 W @ 355 nm |
| Pulse Width | <10 ns @ 1064/532 nm, <8 ns @ 355 nm |
| Repetition Rate | 1–200 kHz (1064 nm), 1–50 kHz (532/355 nm) |
| Pulse Energy | 900 µJ @ 1064 nm, 500 µJ @ 532 nm, 300 µJ @ 355 nm |
| Beam Quality (M²) | <1.2 @ 1064/532 nm, <1.3 @ 355 nm |
| Pulse-to-Pulse Stability (σ) | <2% |
| Cooling | Air-cooled, no external heat sink required |
| Control Interface | RS-232, software-controllable with multiple trigger modes (TTL, analog, external sync) |
| Enclosure | Hermetically sealed, industrial-grade housing |
| Beam Mode | TEM₀₀ |
| Brand | XITON |
|---|---|
| Origin | Germany |
| Model | IMPRESS 213/224 nm |
| Wavelength | 213 nm / 224 nm |
| Average Output Power | 150 mW (213 nm) / 300 mW (224 nm) |
| Pulse Width | <7 ns (213 nm) / <9 ns (224 nm) |
| Pulse Energy | >15 µJ (213 nm) / >30 µJ (224 nm) |
| Repetition Rate | 0.1–30 kHz |
| Beam Quality (M²) | <1.6 |
| Pumping Method | Diode-Pumped |
| Q-Switching | Active |
| Laser Medium | Solid-State (Nd:YAG-based harmonic generation) |
| Brand | XITON |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | IMPRESS 213 / IMPRESS 224 |
| Core Configuration | Diode-Pumped Q-Switched Solid-State Laser System |
| Wavelength | 213 nm / 224 nm |
| Average Output Power | 150 mW / 300 mW |
| Pulse Width | <7 ns / <9 ns |
| Pulse Energy | >15 µJ / >30 µJ |
| Repetition Rate | 0.1–30 kHz |
| Beam Quality (M²) | <1.6 / <1.6 |
| Control Interface | RS-232 |
| Beam Mode | TEM₀₀ |
| Cooling | Air-Cooled |
| Duty Cycle | Continuous Industrial Operation (24/7) |
| Brand | Xiton |
|---|---|
| Origin | Germany |
| Model | IXION-193 SLM |
| Wavelength | 193.368 nm |
| Average Output Power | >10 mW |
| Pulse Width | <10 ns |
| Pulse Energy | 1.6 µJ |
| Repetition Rate | 6 kHz |
| Beam Quality (M²) | <1.6 |
| Spectral Linewidth | <120 MHz (<0.015 pm, <0.004 cm⁻¹) |
| Tuning Range | >80 GHz (>10 pm, >2.6 cm⁻¹) |
| Coherence Length | >1 m |
| Beam Mode | TEM₀₀ |
| Pump Source | Diode-Pumped Solid-State |
| Cooling | Thermoelectric Temperature Control |
| Control Interface | LabVIEW-compatible Driver |