Other Non-destructive Testing Equipment
Filter
Showing 61–90 of 96 results
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma SSM |
| Pricing | Upon Request |
| Spatial Resolution (SQUID) | 3 µm |
| Scan Area (SQUID) | ≥100 mm × 100 mm |
| Current Sensitivity | 500 nA @ 333 µm |
| Magnetic Field Sensitivity | 15 pT/√Hz (typ.) |
| Imaging Depth | 10 mm |
| SQUID Operating Frequency Range | DC to 25 kHz |
| Function Generator | ±10 V @ 100 mA, DC to 200 kHz |
| Optical Lens Resolution | 2 µm (NIR/Visible) |
| Power Supply | 110–120 V @ 20 A or 220–240 V @ 10 A |
| OS | Windows 10 64-bit |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Neutron Radiography |
| Pricing | Upon Request |
| Brand | ORONTEC |
|---|---|
| Origin | Germany |
| Model | Surface Scanner Automatic |
| Type | Modular Automated Coating Characterization System |
| Compliance | ISO 28199 Parts 1–3 |
| Max. Sample Size (Basic) | 600 × 300 mm |
| Max. Integrated Instruments | 4 |
| Power Supply | 230 VAC (Basic), 400 VAC (Large/Flexi) |
| Air Supply | 6 bar, oil-free and filtered |
| Weight | 400–700 kg |
| Software | PLC-controlled measurement orchestration with Excel-based reporting |
| Data Architecture | Local or intranet-deployable database |
| Brand | SEPHA |
|---|---|
| Origin | United Kingdom |
| Model | Multi-Q HD |
| Detection Principle | Vacuum Decay Method (ASTM F2338-09) |
| Compliance | USP <1207>, FDA-recognized CCIT method |
| Minimum Detectable Leak | ≥1 µm |
| Sensor Type | High-resolution absolute pressure transducer with localized in-chamber placement |
| Test Cycle Time | Optimized for high-throughput QC environments |
| Intended Use | Sterile parenteral packaging (vials, syringes, cartridges, blow-fill-seal containers) |
| Regulatory Context | Supports 21 CFR Part 11-compliant data integrity requirements when integrated with validated software |
| Brand | SEPHA |
|---|---|
| Country of Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VisionScan 3D |
| Pricing | Upon Request |
| Brand | Dantec Dynamics |
|---|---|
| Model | FlawScout |
| Technology | Laser Shearography (Speckle Pattern Shearing Interferometry) |
| Origin | Germany |
| Detection Area per Frame | Up to 0.1 m² |
| Typical Inspection Time | <30 s per measurement |
| Excitation Options | Thermal, Vacuum, or Mechanical Vibration |
| Compliance | Designed for ISO 27958, ASTM E2614, and EN 13794-compliant NDT workflows |
| Software | FlawScout Control & Reporting Suite with Audit Trail and Export Capabilities |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MIV-X |
| Pricing | Available upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Xslicer SMX-1010 |
| Pricing | Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CMPK 200 |
| Pricing | Available Upon Request |
| CMVP 50 Vibration Pen | Velocity RMS 0.1–55 mm/s (10 Hz–1 kHz), Acceleration Envelope gE 0.01–45 gE (10 kHz–30 kHz) |
| CMIN 400 Ultrasonic Leak Detector | Frequency Response 20–100 kHz (Center Frequency 38–42 kHz) |
| CMSS 2020 Infrared Thermometer | Temperature Range −18 °C to +260 °C |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CMPK 70 |
| Vibration Pen CMVP 50 | Velocity RMS 0.1–55 mm/s (10 Hz–1 kHz), Acceleration Envelope gE 0.01–45 gE (10 kHz–30 kHz) |
| Oil Condition Checker TMEH 1 | Compatible with mineral & synthetic oils, repeatability <5%, visual green/red indicator + numeric scale (0–100), 9V alkaline battery (IEC 6LR61), 150 h runtime or ~3,000 tests, dimensions 250 × 95 × 32 mm |
| Infrared Thermometer CMSS 2000 | Temperature range −32 °C to +500 °C, accuracy: ±3 °C (−32 to −26 °C), ±2.5 °C (−26 to −18 °C), ±2 °C (−18 to +25 °C), ±1% or ±1 °C (>+25 °C) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMEA 2 |
| Laser Class | Class 2 Semiconductor Diode, 670–675 nm, ≤1 mW |
| Measurement Range | Up to 850 mm |
| System Accuracy | ±0.01 mm |
| Power Supply | Two 1.5 V LR14 Alkaline Batteries (20 h continuous operation) |
| Total Weight | 3.7 kg |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMEB 2 |
| Laser Class | Class 2 Semiconductor Diode, 632 nm, 1 mW |
| Measurement Distance Range | 50 mm – 6 m |
| Angular Accuracy | < 0.2° |
| Power Supply | Two 1.5 V LR14 Alkaline Batteries (20 h continuous operation) |
| Total Weight | 3.7 kg |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMEH 1 |
| Pricing | Upon Request |
| CE Compliance | Fully Compliant with Applicable EU Directives |
| Oil Types Supported | Mineral Oils, Synthetic Lubricants |
| Repeatability | < 5% RSD |
| Display | Dual-mode — Color-coded (Green/Red) + Digital Scale (0–100) |
| Power Supply | 9 V Alkaline Battery (IEC 6LR61) |
| Battery Life | Up to 150 hours operational time or ~3,000 measurements |
| Dimensions (L × W × H) | 250 × 95 × 32 mm |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | TMST 3 |
| Price | Upon Request |
| Frequency Response | 30 Hz – 15 kHz |
| Power Supply | 4 × AAA (R03) batteries, up to 30 hours continuous operation |
| Operating Temperature | −10 °C to +45 °C |
| Maximum Audio Output | 250 mV |
| Headset Dimensions | 220 × 40 × 40 mm |
| Probe Lengths | 70 mm and 220 mm |
| Total Weight | 1560 g |
| Handheld Sensor Weight | 162 g |
| Headset Weight | 250 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SLK MRI-1400 |
| Pricing | Available Upon Request |
| Operating Frequency | 9–13 MHz |
| Sample Diameter Range | 3/16″ to 4″ (4.8–101.6 mm) |
| Maximum Sample Temperature | 300 °F (149 °C) |
| Maximum Sample Pressure | 2000 psi (13.8 MPa) |
| Gradient Capability | Integrated 1D pulsed field gradient (PFG) module |
| Typical Acquisition Time | < 2 minutes per measurement |
| Design | Modular, field-upgradeable architecture |
| Control Interface | Ethernet-based remote operation |
| Environmental Profile | Solvent-free, non-ionizing, no radioactive sources |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | MoviPol-5 |
| Power Source | Rechargeable Li-ion Battery (1.5 h continuous operation) |
| Application | On-site metallographic surface preparation |
| Technique | Electrochemical polishing & etching |
| Portability | Handheld, field-deployable unit |
| Surface Marking | Non-invasive, minimal surface alteration |
| Typical Use Cases | Weld inspection, pipeline integrity assessment, large-component joint analysis |
| Compliance | Designed for ISO 14823, ASTM E3, ASTM E407, and EN 1369-compliant metallographic workflows |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | PSM-5 / PSM-10 |
| Magnification | 100× (standard), up to 400× (PSM-5), up to 600× (PSM-10) |
| Objective Lenses | 10×, 20×, 40× (standard) |
| Eyepiece | 10× wide-field |
| Illumination | Battery-powered high-intensity LED |
| Optional Accessories | Digital camera module, measuring eyepiece, stage micrometer, magnetic cross-stage (PSM-10 only), high-tripod base for curved surfaces (PSM-10 only), aluminum transit case |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | RepliSet |
| Pricing | Available Upon Request |
| Brand | Struers |
|---|---|
| Origin | Denmark |
| Model | TransPol-5 |
| Power Supply | Rechargeable Li-ion battery or AC adapter (100–240 V, 50/60 Hz) |
| Motor | High-torque brushless DC motor |
| Grinding/Polishing Plate Diameter | 32 mm |
| Cable Length | 3 m remote control cable |
| Weight | ≤ 4.5 kg |
| Dimensions (L×W×H) | 220 × 120 × 180 mm |
| Included Accessories | Battery pack, charger, transport case, consumables kit (grinding papers, polishing cloths, diamond suspension), remote control unit |
| Compliance | CE, RoHS, IP54 rated for dust and water resistance |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ELITE |
| Pricing | Available Upon Request |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSC-1M-4 |
| Price | Upon Request |
| Hp Measurement Range | ±2000 A/m |
| Number of Measurement Channels | 2–4 (configurable per probe) |
| Minimum Step Size | 1 mm |
| Maximum Step Size | 128 mm |
| Max Scanning Speed (at 1 mm step) | 0.2–0.5 m/s |
| Basic Relative Error per Channel (Hp) | ±5% |
| Length Measurement Relative Error | <5% |
| Microprocessor | 8-bit |
| RAM Capacity | 128 kB |
| Flash Memory | 4 MB |
| Display | 128×64-pixel monochrome LCD with real-time waveform plotting |
| Data Transfer Interface | RS-232 @ 115 kbps |
| Keypad | 45-key bilingual (English/Russian) tactile keyboard |
| Power Supply | 4×AA NiMH (1.2 V) or alkaline (1.5 V) batteries |
| Power Consumption | 0.8–3.0 V·A |
| Operating Temperature | −15 °C to +55 °C |
| Relative Humidity | 45–85 % RH |
| Dimensions | 230 × 105 × 40 mm |
| Weight | 0.5 kg |
| Probe Types | Type 1 (4-channel wheeled cart, integrated length encoder), Type 2 (2-channel single-wheel probe for small components), Type 3 (2-channel dual-wheel probe for complex geometries and small-diameter pipes), Type 4 (2-channel contact probe without encoder, for confined-access areas) |
| Auto-calibration | Yes, sensor-level real-time compensation |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSC-2M-8 |
| Pricing | Upon Request |
| Origin | Belgium |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WH-Ki |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WTKX-IRNDT-1001 |
| Pricing | Available Upon Request |
| Brand | Xepics |
|---|---|
| Origin | Italy |
| Model | HVB |
| Voltage Range | Up to 30 kV |
| Liquid Conductivity Detection Limit | ≥1 µS/cm |
| Sample Throughput | 120 containers/min |
| Compatible Containers | Vials, Ampoules, Prefilled Syringes, IV Bags, Blow-Fill-Seal (BFS) & Form-Fill-Seal (FFS) containers |
| Dimensions (W×D×H) | 190 × 85 × 127 cm |
| Power Supply | 110–240 VAC, 50–60 Hz, 2 kW |
| Control System | Windows 10 PC with 8" Touchscreen Interface |
| Communication | Ethernet |
| Compliance | Designed to support USP <1207>, ISO 11607-2, ASTM F2338, and FDA 21 CFR Part 11 data integrity requirements |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | XG6000 Series |
| Quotation | Upon Request |
| Dimensions (L×W×H) | 1430 × 848 × 1950 mm |
| Power Supply | 220 V, 10 A, 50–60 Hz |
| Control System | Industrial PC with Windows 10 64-bit |
| Tray Compatibility | 7″–15″, thickness 6–80 mm |
| Barcode Scanning | Integrated |
| Label Printing | Zebra thermal printer |
| System Integration | MES/ERP/WMS (customizable) |
| X-ray Source | Low-energy side-window microfocus tube |
| Tube Voltage | 50 kV (cross-compatible) |
| Tube Current | 0–1000 µA |
| Max Output Power | 50 W |
| Detector | Flat-panel detector |
| Field of View | 434 mm × 434 mm |
| Pixel Matrix | 3072 × 3072 |
| Spatial Resolution | 3.6 lp/mm |
| Radiation Leakage | <1 µSv/hour |
| Safety Interlock | Door-activated beam inhibition |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | Zhengye Technology Co., Ltd. |
| Model | XG6300 |
| Dimensions (L×W×H) | 1430 × 848 × 1950 mm |
| Power Supply | 220 V, 10 A, 50–60 Hz |
| Operating System | Windows 10 Pro 64-bit Industrial PC |
| Compatible Tray Sizes | 7″–15″ (178–381 mm), Tape Width: 6–80 mm |
| X-ray Source | Low-energy side-window microfocus tube, 50 kV nominal voltage, 0–1000 µA current, max. 50 W output |
| Detector | Flat-panel detector, FOV: 434 × 434 mm, Pixel Matrix: 3072 × 3072, Spatial Resolution: 3.6 lp/mm |
| Radiation Leakage | <1 µSv/h at 5 cm from enclosure surface |
| Safety Interlock | Dual-door interlocked shutdown, automatic beam inhibition upon door opening |
| Labeling | Integrated Zebra thermal printer for barcode/label generation |
| System Integration | OPC UA and RESTful API support for MES/ERP/WMS bidirectional data exchange |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XRISM-x |
| Price | USD 23,500 (approx.) |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | CC5120 |
| Pricing | Upon Request |
| Overall Dimensions (L×W×H) | 2100 × 1500 × 1900 mm |
| Power Supply | AC 220 V / 50 Hz / 2 kW |
| Inspection Throughput | ≥25 parts per minute (PPM) |
| Repeatability & Reproducibility (GRR) | ≤10% |
| Applicable Cell Dimensions (L×W×T) | 40–160 mm × 30–110 mm × 2–12 mm |
| Dimensional Repeatability | ±0.01 mm |
| PPG Flatness | ≤10 µm |
| PPG Parallelism | ≤20 µm |
| Barcode Types Supported | 1D & 2D barcodes |
| Barcode Recognition Rate | ≥99.8% |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | DY5120 |
| Power Supply | AC 220 V / 50 Hz / 2.5 kW |
| Overall Dimensions (L×W×H) | 2600 × 1700 × 2000 mm |
| Test Throughput | ≥30 PPM |
| Voltage Measurement Accuracy | ±0.01% rdg + 3 digits |
| Internal Resistance Measurement Accuracy | ±0.5% rdg + 5 digits |
| Barcode Recognition Rate | ≥99.8% |
| Supported Barcode Types | 1D & 2D barcodes |
| Applicable Cell Dimensions (L×W×T) | 40–160 mm × 30–110 mm × 2–12 mm |
| Gage R&R (GRR) | ≤10% |
| False Rejection Rate | 0.0% |
| Repeatability & Reproducibility | GRR ≤10% |
| Control System | HMI-integrated PLC with servo-driven motion control |
| Vision System | CCD-based positioning and alignment |
| Automation Architecture | 4-axis robotic handling platform |